| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YXQ-LS-75G |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 720 mm |
| External Dimensions | 485 × 605 × 1190 mm |
| Chamber Volume | 75 L |
| Sterilization Power | 3.5 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Design Temp/Pressure | 138 °C / 0.25 MPa |
| Sterilization Timer Range | 4–120 min |
| Drying Timer Range | 30–240 min |
| Basket Dimensions | Ø360 × 280 mm (2 pcs) |
| Brand | Brookfield (BOXUN) |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-110VF |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 585 × 750 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temp Range | 80–130 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Power Input | 5.4 kW |
| Voltage | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | Brookfield (BOXUN) |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-60EI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 635 mm |
| External Dimensions | 535 × 640 × 1075 mm |
| Chamber Volume | 60 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Power Supply | ~220 V ±22 V, 50 Hz ±1 Hz |
| Heating Power | 3.2 kW |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | Brookfield (BOXUN) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BXW-SD |
| Instrument Type | Horizontal |
| Max Temperature | 131 °C |
| Max Pressure | 0.2 MPa |
| Chamber Dimensions | Ø472 mm × 1025 mm |
| External Dimensions | 764 mm × 1460 mm × 1590 mm |
| Chamber Volume | 150 L |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXW-SD-A/G |
| Instrument Type | Horizontal |
| Max Temperature | 131 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Ø600 × 1050 mm |
| External Dimensions | 911 × 1432 × 1803 mm |
| Chamber Volume | 280 L |
| Power Supply | 380 V / 50 Hz |
| Heating Power (A-type) | 13 kW |
| Heating Power (G-type) | 14.5 kW |
| Compliance | Designed for GLP-compliant sterilization workflows, compatible with ISO 17665-1, EN 285, and GB 8599 standards |
| Brand | Brookfield |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-LS-50A |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 135 °C |
| Maximum Pressure | 0.25 MPa |
| Chamber Dimensions | Ø300 mm × 680 mm |
| External Dimensions | 525 mm × 440 mm × 1080 mm |
| Chamber Volume | 50 L |
| Power Rating | 2.7 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating Pressure Range | 0–0.22 MPa (working), 0–0.25 MPa (design) |
| Temperature Control Range | Ambient to 135 °C |
| Timer Range | 0–120 min |
| Exhaust Mode | Internal recirculating steam exhaust with 3 L gas collection bottle |
| Safety Features | Dual pressure interlock, self-sealing gasket, automatic cold air purge, low/high water level alarm, dry-run protection, overtemperature cutoff, pressure relief valve |
| Brand | Brookfield (BOXUN) |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-LS-75G |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 720 mm |
| Chamber Volume | 75 L |
| External Dimensions | 485 × 605 × 1190 mm |
| Sterilization Power | 3.5 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Sterilization Timer | 4–120 min |
| Drying Timer | 30–240 min |
| Safety Design Pressure/Temperature | 0.25 MPa / 138 °C |
| Basket Size | Ø360 × 280 mm × 2 pcs |
| Material | SUS304 stainless steel chamber, door, and baskets |
| Brand | — |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BXM-75M |
| Instrument Type | Benchtop |
| Max Temperature | 135 °C |
| Operating Pressure | 0.22 MPa (Design: 0.25 MPa) |
| Chamber Dimensions | Ø400 mm × 700 mm |
| External Dimensions | 750 mm × 800 mm × 1080 mm |
| Chamber Volume | 75 L |
| Drying Residual Moisture | <1% |
| Heating Power | 5.9 kW |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | CertoClav |
|---|---|
| Origin | Austria |
| Model | 8 Vac Pro |
| Instrument Type | Vertical Autoclave |
| Maximum Temperature | 120 °C |
| Maximum Pressure | 0.145 MPa |
| Chamber Dimensions | 20 × 36 cm |
| External Dimensions | 61 × 50 × 43 cm |
| Chamber Volume | 12 L |
| Power Supply | 220–240 V AC, 50 Hz, 2400 W |
| Control Interface | 7″ Touchscreen |
| Connectivity | Wi-Fi, LAN, USB, CF Card slot, Printer port |
| Vacuum System | Integrated Thomas vacuum pump & gas generator |
| Cooling | Forced-air cooling with bacterial filter |
| Water Management | Separate feed and waste tanks |
| Safety | Electrical safety enclosure, steam trap, automatic water level monitoring |
| Programs | 9 pre-installed cycles + user-programmable cycles |
| Compliance | Designed to meet EN 13060:2022 (Small Steam Sterilizers), ISO 17665-1, and supports GLP/GMP documentation requirements |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZM-100A |
| Instrument Type | Vertical Sterilizer |
| Max Temperature | 135 °C |
| Max Pressure | 0–0.22 MPa (Saturated Steam Pressure) |
| Sterilization Chamber Dimensions | Ø400 mm × 500 mm (H) |
| External Dimensions | Ø500 mm × 560 mm (H) |
| Chamber Volume | 50 L |
| Safety Relief Pressure | 0.23 MPa |
| Back-Pressure Range | 0.14–0.165 MPa |
| Water Replenishment Pressure | ≥0.32 MPa |
| Timer Range | 1–99.59 min |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 4.5 kW ±10% |
| Compliance Standards | GB 150.1–2011, GB/T 10004–2008, GB 4793.4–2001, YY 1007–2010 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZM-100B |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0–0.22 MPa (Saturated Steam Pressure) |
| Sterilization Chamber Dimensions | Ø400 mm × 500 mm (H) |
| External Dimensions | Ø500 mm × 560 mm (H) |
| Chamber Volume | 50 L |
| Safety Relief Pressure | 0.23 MPa |
| Back-Pressure Range | 0.14–0.165 MPa |
| Time Setting Range | 1–99.59 min |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 4.5 kW ±10% |
| Compliance | GB 150.1–2011, GB/T 10004–2008, GB 4793.4–2001, YY 1007–2010 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Type | Vertical Sterilizer |
| Model | ZM-100C |
| Max Temperature | 135 °C |
| Max Pressure | 0–0.22 MPa (saturated steam) |
| Chamber Dimensions | Ø400 mm × 500 mm (H) |
| External Dimensions | Ø500 mm × 560 mm (H) |
| Chamber Volume | 50 L |
| Safety Relief Pressure | 0.23 MPa |
| Counter-Pressure Range | 0.14–0.165 MPa |
| Timing Range | 1–99.59 min |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 4.5 kW ±10% |
| Compliance | GB 150.1–2011, GB/T 10004–2008, GB 4793.4–2001, YY 1007–2010 |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNM-800D |
| Instrument Type | Horizontal Benchtop Infrared Sterilizer |
| Maximum Operating Temperature | 825 °C ± 50 °C |
| Sterilization Chamber Diameter | 35 mm |
| External Dimensions | Not specified (compact benchtop unit) |
| Power Rating | 200 W |
| Net Weight | 1.5 kg |
| Input Voltage | AC 220 V ± 10 %, 50 Hz |
| Standby Temperature | 480 °C |
| Sterilization Time (typical) | 5–7 s |
| Compatible Tool Outer Diameter | ≤35 mm |
| Heating Zone Length | 100 mm |
| Operating Ambient Temperature | 10–50 °C |
| Relative Humidity Limit | ≤90 % RH |
| Altitude | Unrestricted |
| Brand | HePu (Jihepu) |
|---|---|
| Origin | Shandong, China |
| Model | WS-200YDA |
| Sterilization Chamber Volume | 200 L (Ø515 mm × 1000 mm) |
| Maximum Operating Temperature | 134 °C ± 1 °C |
| Maximum Working Pressure | 0.22 MPa |
| Temperature Range | 40–134 °C |
| Sterilization Time Range | 1–60 min |
| Drying Time Range | 1–60 min |
| Thermal Uniformity | ≤2 °C |
| Power Supply | 9 kW / 380 V AC, 50 Hz |
| Safety Interlocks | Door lock at >0.027 MPa, low-water cutoff, overpressure relief valve (0.24 MPa), leakage & overload protection |
| Net Weight | 260 kg |
| Overall Dimensions (L×W×H) | 1560 × 820 × 1850 mm |
| Brand | Ilshin Autoclave |
|---|---|
| Origin | South Korea |
| Model | Mini HIPPO |
| Type | Vertical Autoclave |
| Max Temperature | 35 °C |
| Max Pressure | 6000 bar |
| Chamber Dimensions | 590 × 780 × 1645 mm |
| External Dimensions | 590 × 780 × 1645 mm |
| Chamber Volume | 0.5 L |
| Equipment Category | Imported |
| Distributor Type | General Distributor |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vertical Sterilizer |
| Max Temperature | 141 °C |
| Max Pressure | 0.3 MPa |
| Chamber Dimensions | Ø400 × 778 mm |
| External Dimensions | 630 × 680 × 1120 mm |
| Chamber Volume | 100 L |
| Temperature Display Resolution | 0.1 °C |
| Control System | iSmart Intelligent Microcomputer Controller (PID + PLC) with 7-inch Color TFT Touchscreen |
| Cooling Time to Safe Opening | ~6 minutes |
| Exhaust Modes | Full Exhaust, Pulse Exhaust, No Exhaust |
| Safety Certifications | Dual Active & Passive Safety Architecture |
| Vessel Material | SUS304 Stainless Steel |
| Sealing Ring | High-Performance Silicone |
| Heating Element | Titanium Alloy (3.2 kW) |
| Power Supply | AC 220 V, 3.3 kW |
| Standard Accessories | 2–3 Stainless Steel Baskets (Ø370 × 220 mm, 5 × 5 high-density perforation), Water Pan, Waste Collection Bucket, 16 A Socket |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | B75 |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 141 °C |
| Max Pressure | 0.3 MPa |
| Chamber Dimensions | Ø400 × 583 mm |
| External Dimensions | 630 × 680 × 900 mm |
| Chamber Volume | 75 L |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | G75 |
| Instrument Type | Vertical Sterilizer |
| Maximum Temperature | 141 °C |
| Maximum Pressure | 0.3 MPa |
| Chamber Dimensions | 400 mm × 583 mm (Ø × H) |
| External Dimensions | 630 mm × 680 mm × 900 mm (W × D × H) |
| Chamber Volume | 75 L |
| Control Interface | 7-inch color LCD touchscreen |
| Heating Element | Titanium alloy, 3.2 kW |
| Chamber Material | SUS304 stainless steel |
| Sealing Ring | High-performance imported silicone |
| Safety Certifications | Dual active/passive safety architecture, independent overpressure and overtemperature protection, door interlock with real-time lid closure monitoring, dry-run prevention (dual-level water level detection), automatic fault diagnostics for SSR, CPU, sensors, valves, and power circuits |
| Cooling System | iSpeed rapid cooling module (lid openable in ~6 minutes) |
| Exhaust Modes | Full exhaust, pulse exhaust, no exhaust |
| Drainage | Automatic wastewater discharge (to floor drain or optional collection tank) |
| Power Supply | AC 220 V, 3.3 kW |
| [Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Type | Vertical Sterilizer |
| Max Temperature | 134 °C |
| Max Pressure | 0.21 MPa |
| Chamber Dimensions | Ø323 × 480 mm |
| External Dimensions | 560 × 600 × 1250 mm |
| Chamber Volume | 63 L |
| Control Interface | 7-inch Color Touchscreen |
| Safety Compliance | Dual Active/Passive Safety Architecture |
| Cooling System | iSpeed Automated Rapid-Cooling Module (6-min lid opening) |
| Operating Modes | 8 Predefined Cycles |
| Exhaust Modes | Internal Exhaust, Full Exhaust, Pulse Exhaust |
| Power Supply | AC 220 V / 3.5 kW |
| Heating Element | Titanium Alloy |
| Chamber Material | SUS304 Stainless Steel |
| Door Mechanism | Interlocked Manual Handwheel Translation |
| User Access Control | 5-Tier Permission Management] |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | L75 |
| Instrument Type | Vertical |
| Maximum Temperature | 141 °C |
| Maximum Pressure | 0.3 MPa |
| Chamber Dimensions | Ø400 × 583 mm |
| External Dimensions | 630 × 680 × 900 mm |
| Chamber Volume | 75 L |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | NE100 |
| Instrument Type | Vertical |
| Maximum Temperature | 141 °C |
| Maximum Pressure | 0.3 MPa |
| Chamber Dimensions | Ø400 × 778 mm |
| External Dimensions | 630 × 680 × 1120 mm |
| Chamber Volume | 100 L |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NE75 |
| Instrument Type | Vertical |
| Max Temperature | 141 °C |
| Max Pressure | 0.3 MPa |
| Chamber Dimensions | Ø400 × 538 mm |
| External Dimensions | 630 × 680 × 900 mm |
| Chamber Volume | 75 L |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PD22 |
| Instrument Type | Portable |
| Max Temperature | 129 °C |
| Max Pressure | 0.165 MPa |
| Chamber Dimensions | Ø260 × 250 mm |
| External Dimensions | Ø283 × 600 mm |
| Chamber Volume | 22 L |
| Heating Power | 2.0 kW |
| Temperature Display Resolution | 0.1 °C |
| Sterilization Time Range | 0–60 min |
| Control System | Intelligent Microprocessor-Based Controller |
| Display | LED Digital Screen |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Sealing Ring Material | High-Performance Imported Silicone |
| Lid Mechanism | Quick-Opening with Interlocked Safety Lock |
| Safety Features | Dual Water-Level Detection (Pre-Start & Real-Time), Overpressure Relief Valve, Lid-Interlock Safety Circuit, Dry-Run Prevention, CPU Self-Diagnostic Function |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | Ju Chuang Environmental |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Category | Domestic |
| Model | JC-STZK18L |
| Instrument Type | Portable |
| Max Temperature | 129 °C |
| Max Pressure | 0.165 MPa |
| Chamber Dimensions (D×W×H) | Φ280 mm × 243 mm × 383/423 mm |
| External Dimensions (W×D×H) | 400 mm × 400 mm × 530/640/700 mm |
| Chamber Volume | 18 L / 24 L / 30 L |
| Construction Material | AISI 304 Stainless Steel |
| Safety Pressure Relief Range | 0.145–0.165 MPa |
| Heating Element | Immersed Tubular Heater |
| Sealing | Silicone Rubber Gasket |
| Pressure Gauge | Dual-Scale Class II Analog Gauge |
| Control Mode | Programmable Time/Temperature Setting with Dry-Run Protection and Audible End-of-Cycle Alert |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Capacity | 50 L |
| Max Operating Temperature | 10°C above ambient to 135°C |
| Max Working Pressure | 0–0.22 MPa |
| Chamber Volume | 50 L |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 2 kW |
| Timer Range | 0–999 min |
| Cooling Method | Forced-air cooling with reverse-pressure compensation |
| Safety Features | Over-temperature, over-pressure, low-water-level, and leakage protection |
| Compliance Documentation | Full calibration records, verification reports, and metrological compliance documentation per Chinese National Verification Regulation JJG 748 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Models | LDZM-40KCS, LDZM-60KCS, LDZM-80KCS |
| Chamber Volume | 40 L / 60 L / 80 L |
| Power Supply | 220 V AC, 50 Hz |
| Heating Power | 3.5 kW |
| Chamber Dimensions (Ø × H) | 370 × 380 mm / 370 × 560 mm / 370 × 750 mm |
| Net Weight | 95 kg / 105 kg / 120 kg |
| External Dimensions (W × D × H) | 660 × 780 × 950 mm / 660 × 780 × 1150 mm / 660 × 780 × 1330 mm |
| Sterilization Temperature Range | 50–134 °C |
| Time Setting Range | 0–99 h |
| Safety Features | Interlocked door mechanism, low-water cutoff protection, automatic buzzer alert and shutdown upon cycle completion |
| Optional Accessories | Internal steam exhaust system, thermal printer interface, post-sterilization drying function |
| Capacity | 50 L |
|---|---|
| Power Supply | 220 V AC |
| Heating Power | 3.5 kW |
| Chamber Dimensions | Φ350 × 520 mm |
| Net Weight | 80 kg |
| Overall Dimensions | 600 × 580 × 1250 mm |
| Operating Pressure Range | 0–0.165 MPa |
| Max Operating Temperature | 128 °C |
| Safety Relief Pressure | 0.145–0.165 MPa |
| Brand | MMM |
|---|---|
| Origin | Germany |
| Model Options | 15 L, 20 L, 25 L |
| Maximum Temperature | 134 °C |
| Maximum Pressure | 3.1 bar (g) |
| Chamber Dimensions | Ø238 mm × 430 mm (L) |
| External Dimensions | 460 mm × 720 mm × 430 mm (W×H×D) |
| Chamber Volume | 15 L / 20 L / 25 L |
| Sterilization Method | Pulsed Vacuum Steam Sterilization (STERIDENT & STERIMAT) |
| Vacuum System | Integrated diaphragm vacuum pump (max. –87 kPa) |
| Control Interface | Full-color TFT touchscreen |
| Chamber Material | AISI 316 stainless steel (EN 10088-1 compliant) |
| Compliance | prEN 13060:2023, EN 285, DIN 58950, DIN 58951, PED 2014/68/EU, Machinery Directive 2006/42/EU, FDA 21 CFR Part 11 (with optional audit trail), GMP/cGMP, GAMP 5 |
| Brand | MMM |
|---|---|
| Origin | Germany |
| Model | Sterivap |
| Type | Vertical Autoclave |
| Chamber Volume | 148–2056 L |
| Construction Material | AISI 316L Stainless Steel Chamber & Double Jacket |
| Compliance | EN 285, EN 554, EN ISO 11134, prEN 866-4 to -8, prEN 868-9 to -10, ISO 14161, ASME BPVC Section VIII, PED 97/23/EC, IEC 61010, HTM 2010/2031, 21 CFR Part 11 (with optional software), GLP/GMP-ready |
| Safety Features | Dual CPU Control, Independent Pressure & Temperature Sensors, Mechanical Door Interlock, Overpressure & Low-Water Cut-off, HEPA-Filtered Air Inlet/Exhaust, P3/P4 Biological Sealing |
| Vacuum System | Two-Stage Water-Ring Vacuum Pump with 70% Reduced Water Consumption |
| Control Interface | 8.2" Touchscreen HMI with Real-Time Curve Logging |
| Standard Programs | 4 Predefined + Up to 14 Customizable Cycles (incl. BD Test, VT Test, Preheat) |
| Optional | Integrated Pure Steam Generator (EN 285 Compliant), F₀-Control Software, IQ/OQ Documentation Package, Mobile PT100 Probe, Rapid Cooling Module, Air Content Sensor |
| Brand | MMM |
|---|---|
| Origin | Germany |
| Model | UNISTERI |
| Instrument Type | Vertical |
| Max Temperature | 134 °C |
| Max Pressure | 3.1 bar |
| Chamber Dimensions | 509 × 990 mm |
| External Dimensions | 1720 × 850 × 1247 mm |
| Chamber Volume Options | 73 L, 160 L, 254 L |
| Chamber Material | 316L stainless steel |
| Jacket Material | 316Ti stainless steel |
| Steam Contact Piping | 316L stainless steel |
| Vacuum System | Two-stage vacuum pump |
| Filtration | Integrated inlet and exhaust HEPA/sterile-grade filters |
| Cooling Options | Natural or rapid cooling |
| Documentation | Built-in thermal printer for real-time temperature/pressure curves and cycle logs |
| Compliance | EN 285, DIN 58951, DIN 58950, PED 2014/68/EU, Machinery Directive 2006/42/EU, FDA 21 CFR Part 11 (with optional audit trail), GMP/cGMP, GLP, GAMP 5 |