- All
- Favorite
- Popular
- Most rated
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-300 |
| Channel Count | 6 |
| Current Range | ±500 mA |
| Current Resolution | down to 76 aA (with ULC option) |
| Current Accuracy | ±20 nA on 10 µA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±1 A (extendable to ±20 A) |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Sampling Rate | up to 1 µs |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Software | EC-Lab® v12+ with FDA 21 CFR Part 11-compliant audit trail option |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-3e |
| Channel Count | 16 independent channels |
| Current Range | 76 fA to 100 A (with external amplifiers) |
| Current Accuracy | ±0.1% |
| Potential Range | ±10 V (DC), 0–20 V (galvanostatic mode) |
| Potentiostatic Range | ±20 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Data Acquisition Rate | 200,000 points/sec |
| Potential Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Switching Time (Potentiostatic ↔ Galvanostatic) | <10 µs |
| Input Impedance | >10^14 Ω |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG2 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±10 A (per channel with optional high-current modules) |
| Current Resolution | 760 pA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 20 kHz |
| Data Acquisition Rate | 200,000 points/s |
| Channels | 16 independent, fully isolated |
| Voltage Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-150e |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Dual-Channel |
| Current Range | ±1 A |
| Current Resolution | 760 pA (optional 76 fA) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Voltage Resolution | 300 μV (dynamically adjustable down to 5 μV) |
| Data Acquisition Rate | 200,000 points/s |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-300 |
| Number of Channels | 16 |
| Current Range | ±500 mA |
| Current Accuracy | ±0.1% |
| Potential Accuracy | ±0.1% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Compliance | ±12 V |
| Control Voltage Range | ±10 V |
| Current Resolution (standard board) | 760 fA |
| Floating Mode | Yes |
| Analog Filtering | Built-in |
| Calibration Board | Integrated |
| Control Stability | Digital PID with adaptive tuning |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-200 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Resolution | 1 µV (dynamic range adjustable down to 1 µV) |
| Data Acquisition Rate | 1,000,000 points/second |
| Optional ULC Module | 100 pA (down to 1 pA) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-50e |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±20 nA (on 10 μA range) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Current Resolution | 760 pA |
| Voltage Resolution | Adjustable from 300 μV down to 5 μV |
| Data Acquisition Rate | 200,000 points/s |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCP-803 |
| Current Range | ±80 A |
| Current Resolution | 760 pA (1 nA–400 nA range) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Dynamic Potential Resolution | 300 µV (adjustable down to 5 µV) |
| EIS Frequency Range | 10 µHz–1 MHz (standard), 10 µHz–10 kHz (with 80 A booster) |
| Booster Module | Removable high-current extension unit |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-300 |
| Channel Count | Dual-channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±48 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Data Acquisition Rate | 1,000,000 pts/s |
| Voltage Resolution | 1 µV (dynamic range adjustable) |
| Optional Modules | ULC (1 pA), High-Current (4 A/14 V), High-Voltage (1 A/48 V) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | FlexP 0160 |
| Current Range | ±50 A per channel (up to ±200 A with 4-channel parallel configuration) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz – 1 MHz |
| Voltage Compliance Range | 1–60 V |
| Voltage Accuracy | 0.2% of reading ± 0.1% FS |
| Current Accuracy (high-current mode) | 0.2% of reading ± 0.1% FS up to 50 A |
| Slew Rate | 1 V/μs |
| Rise/Fall Time | 20 μs |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-3e |
| Channel Count | 8 |
| Current Range | ±1 pA to ±1 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±10 V (adjustable up to ±20 V) |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Voltage Resolution | 5 µV (within ±200 mV range) |
| Current Resolution | 0.76 nA |
| Minimum Sampling Interval | 200 µs |
| Control Bandwidth | 7 adjustable bandwidths |
| Connectivity | Ethernet (LAN), USB, optional EIS module |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP |
| Channel Count | 5 independent channels |
| Current Range | 1 nA to 100 A (with external amplifier) |
| Current Resolution | 76 fA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±4 A (built-in), up to ±100 A (with external current booster) |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Data Acquisition Rate | 200,000 points/s |
| Voltage Resolution | 300 µV (dynamic adjustment down to 5 µV) |
| Supported Techniques | CV, LSV, CA, CP, EIS (potentiostatic/galvanostatic/step-mode), DPV, SWV, NPV, Mott-Schottky, ZRA/ZVC, corrosion polarization, GITT, PITT, constant-power discharge, potentiometric titration, and multi-step sequence protocols |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCV-3048 |
| Current Range | ±30 A (per channel), up to ±120 A (4-channel parallel operation) |
| Current Accuracy | 0.1–0.3% (range + reading) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Voltage Range | 0–48 V |
| Voltage Accuracy | 0.03% (range + reading) |
| Slew Rate | >20 V/µs |
| Rise/Fall Time | <3 µs (0–48 V step) |
| Input Impedance | 100 GΩ |
| Bandwidth | 800 kHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | M470 |
| Instrument Type | Scanning Electrochemical Workstation |
| Current Range | 1 pA – 10 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Scan Range (X/Y/Z) | >100 mm |
| Closed-Loop Positioning Resolution | 0.1 nm |
| Spatial Resolution (X/Y/Z) | 20 nm |
| Max Scan Speed | 12.5 mm/s |
| ADC/DAC Resolution | 32-bit @ up to 40 MHz |
| Piezo Vibration Range | 20 nm – 2 µm (peak-to-peak, 1 nm step) |
| Piezo Minimum Vibration Resolution | 0.12 nm (16-bit DAC, 4 µm range) |
| Piezo Extension | 100 µm |
| Piezo Positioning Resolution | 0.09 nm (20-bit DAC, 100 µm range) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Uniscan M370 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±1 A |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±10 mV |
| Potentiostatic Range | ±20 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG-2XX |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±40 A |
| Current Accuracy | ±20 nA on 10 μA |
| Potential Accuracy | <5 mV on ±2.5 V |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz – 1 MHz |
Show next