Empowering Scientific Discovery

Huayang Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelVSP-300
Channel Count6
Current Range±500 mA
Current Resolutiondown to 76 aA (with ULC option)
Current Accuracy±20 nA on 10 µA range
Potential Accuracy<5 mV on ±2.5 V range
Potentiostatic Range±10 V
Galvanostatic Range±1 A (extendable to ±20 A)
EIS Frequency Range10 µHz – 7 MHz
Sampling Rateup to 1 µs
ComplianceCE, RoHS, ISO 9001-certified manufacturing
SoftwareEC-Lab® v12+ with FDA 21 CFR Part 11-compliant audit trail option
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelVMP-3e
Channel Count16 independent channels
Current Range76 fA to 100 A (with external amplifiers)
Current Accuracy±0.1%
Potential Range±10 V (DC), 0–20 V (galvanostatic mode)
Potentiostatic Range±20 V
EIS Frequency Range10 µHz to 1 MHz
Data Acquisition Rate200,000 points/sec
Potential Resolution300 µV (dynamic range adjustable down to 5 µV)
Switching Time (Potentiostatic ↔ Galvanostatic)<10 µs
Input Impedance>10^14 Ω
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelMPG2
Instrument TypeElectrochemical Workstation
Current Range±10 A (per channel with optional high-current modules)
Current Resolution760 pA
Potential Accuracy±5 µV
Potentiostatic Range±10 V
EIS Frequency Range10 µHz – 20 kHz
Data Acquisition Rate200,000 points/s
Channels16 independent, fully isolated
Voltage Resolution300 µV (dynamic range adjustable down to 5 µV)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelSP-150e
Instrument TypePortable Electrochemical Workstation
Number of ChannelsDual-Channel
Current Range±1 A
Current Resolution760 pA (optional 76 fA)
Current Accuracy±20 nA on 10 μA range
Potential Accuracy<5 mV on ±2.5 V range
Potentiostatic Range±10 V
EIS Frequency Range10 μHz to 1 MHz
Voltage Resolution300 μV (dynamically adjustable down to 5 μV)
Data Acquisition Rate200,000 points/s
ComplianceCE, RoHS, IEC 61010-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelVMP-300
Number of Channels16
Current Range±500 mA
Current Accuracy±0.1%
Potential Accuracy±0.1%
Potentiostatic Range±10 V
EIS Frequency Range10 µHz – 7 MHz
Voltage Compliance±12 V
Control Voltage Range±10 V
Current Resolution (standard board)760 fA
Floating ModeYes
Analog FilteringBuilt-in
Calibration BoardIntegrated
Control StabilityDigital PID with adaptive tuning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelSP-200
Instrument TypePortable Electrochemical Workstation
Channel CountSingle-Channel
Current Range±500 mA
Current Resolution76 aA
Potential Accuracy±0.1% of full scale
Potentiostatic Range±12 V
EIS Frequency Range10 µHz – 7 MHz
Voltage Resolution1 µV (dynamic range adjustable down to 1 µV)
Data Acquisition Rate1,000,000 points/second
Optional ULC Module100 pA (down to 1 pA)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelSP-50e
Instrument TypePortable Electrochemical Workstation
Channel CountSingle-Channel
Current Range±1 A
Current Accuracy±20 nA (on 10 μA range)
Potential Accuracy<5 mV (on ±2.5 V range)
Potentiostatic Range±10 V
EIS Frequency Range10 μHz to 1 MHz
Current Resolution760 pA
Voltage ResolutionAdjustable from 300 μV down to 5 μV
Data Acquisition Rate200,000 points/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelHCP-803
Current Range±80 A
Current Resolution760 pA (1 nA–400 nA range)
Current Accuracy±20 nA on 10 μA range
Potential Accuracy<5 mV on ±2.5 V range
Potentiostatic Range±10 V
Dynamic Potential Resolution300 µV (adjustable down to 5 µV)
EIS Frequency Range10 µHz–1 MHz (standard), 10 µHz–10 kHz (with 80 A booster)
Booster ModuleRemovable high-current extension unit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelSP-300
Channel CountDual-channel
Current Range±500 mA
Current Resolution76 aA
Potential Accuracy±1 mV
Potentiostatic Range±48 V
EIS Frequency Range10 µHz – 7 MHz
Data Acquisition Rate1,000,000 pts/s
Voltage Resolution1 µV (dynamic range adjustable)
Optional ModulesULC (1 pA), High-Current (4 A/14 V), High-Voltage (1 A/48 V)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelFlexP 0160
Current Range±50 A per channel (up to ±200 A with 4-channel parallel configuration)
Current Accuracy±20 nA on 10 μA range
Potential Accuracy<5 mV on ±2.5 V range
Potentiostatic Range±10 V
EIS Frequency Range10 μHz – 1 MHz
Voltage Compliance Range1–60 V
Voltage Accuracy0.2% of reading ± 0.1% FS
Current Accuracy (high-current mode)0.2% of reading ± 0.1% FS up to 50 A
Slew Rate1 V/μs
Rise/Fall Time20 μs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelVSP-3e
Channel Count8
Current Range±1 pA to ±1 A
Current Accuracy±0.0033% of reading
Potential Accuracy±1 µV
Potentiostatic Range±10 V (adjustable up to ±20 V)
EIS Frequency Range10 µHz to 1 MHz
Voltage Resolution5 µV (within ±200 mV range)
Current Resolution0.76 nA
Minimum Sampling Interval200 µs
Control Bandwidth7 adjustable bandwidths
ConnectivityEthernet (LAN), USB, optional EIS module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelVSP
Channel Count5 independent channels
Current Range1 nA to 100 A (with external amplifier)
Current Resolution76 fA
Potential Accuracy±5 µV
Potentiostatic Range±10 V
Galvanostatic Range±4 A (built-in), up to ±100 A (with external current booster)
EIS Frequency Range10 µHz – 1 MHz
Data Acquisition Rate200,000 points/s
Voltage Resolution300 µV (dynamic adjustment down to 5 µV)
Supported TechniquesCV, LSV, CA, CP, EIS (potentiostatic/galvanostatic/step-mode), DPV, SWV, NPV, Mott-Schottky, ZRA/ZVC, corrosion polarization, GITT, PITT, constant-power discharge, potentiometric titration, and multi-step sequence protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelHCV-3048
Current Range±30 A (per channel), up to ±120 A (4-channel parallel operation)
Current Accuracy0.1–0.3% (range + reading)
Potential Accuracy<5 mV (on ±2.5 V range)
Potentiostatic Range±10 V
EIS Frequency Range10 µHz – 1 MHz
Voltage Range0–48 V
Voltage Accuracy0.03% (range + reading)
Slew Rate>20 V/µs
Rise/Fall Time<3 µs (0–48 V step)
Input Impedance100 GΩ
Bandwidth800 kHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelM470
Instrument TypeScanning Electrochemical Workstation
Current Range1 pA – 10 A
Current Accuracy±0.0033% of reading
Potential Accuracy±1 µV
Potentiostatic Range±30 V
EIS Frequency Range10 µHz – 7 MHz
Scan Range (X/Y/Z)>100 mm
Closed-Loop Positioning Resolution0.1 nm
Spatial Resolution (X/Y/Z)20 nm
Max Scan Speed12.5 mm/s
ADC/DAC Resolution32-bit @ up to 40 MHz
Piezo Vibration Range20 nm – 2 µm (peak-to-peak, 1 nm step)
Piezo Minimum Vibration Resolution0.12 nm (16-bit DAC, 4 µm range)
Piezo Extension100 µm
Piezo Positioning Resolution0.09 nm (20-bit DAC, 100 µm range)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelUniscan M370
Instrument TypeElectrochemical Workstation
Current Range±1 A
Current Accuracy±0.1% of reading
Potential Accuracy±10 mV
Potentiostatic Range±20 V
AC Impedance Frequency Range10 µHz – 1 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelMPG-2XX
Instrument TypeElectrochemical Workstation
Current Range±40 A
Current Accuracy±20 nA on 10 μA
Potential Accuracy<5 mV on ±2.5 V
Potentiostatic Range±10 V
EIS Frequency Range10 μHz – 1 MHz
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0