Empowering Scientific Discovery

Huayang Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelMOS-500
Instrument TypeCircular Dichroism (CD) Spectrometer
Light Sources150 W Xenon Lamp + 150 W Mercury-Xenon Lamp
Detection ModesCD, UV-Vis Absorption, Fluorescence CD (FCD), Linear Dichroism (LD), Fluorescence Anisotropy
Wavelength Range163–950 nm (extendable to 1250 nm)
Wavelength Accuracy±0.1 nm (163–1250 nm)
Optical SystemDual Grating Monochromator
Stray Light<2 × 10⁻⁶ at 200 nm
Baseline Stability0.007 mdeg/hr
Maximum Scan Speed12,000 nm/min
Solid Sample CapabilityIntegrated Integrating Sphere for Diffuse Reflectance
Stopped-Flow UnitTriple- or Quadruple-Channel Mixing with Independent Stepper-Motor Control
Minimum Injection Volume10 µL
Flow Rate Range0.01–40 mL/s
Mixing Ratio RangeContinuously Adjustable from 1:1 to 1:100
Mixer TypeSpherical High-Efficiency Mixing Cell
Dead Time0.2 ms (with Microcell Accessory)
Expandable ModulesCryo-Quench, Sub-Zero Stopped-Flow, Temperature-Jump (T-Jump), Automated Titration, Microconductivity Detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelMOS-450
Instrument TypeCircular Dichroism (CD) Spectrometer
Light Sources150 W Xenon Lamp + 150 W Mercury-Xenon Lamp
Wavelength Range165–900 nm
Wavelength Accuracy±0.1 nm (165–900 nm)
Optical SystemDual Grating (1200 grooves/mm)
Stray Light< 2 × 10⁻⁴ % (at 200 nm)
Noise Level (CD)0.01 mdeg
Baseline Stability< 0.01 mdeg/hr
Data Acquisition Rate10 µs to 1000 s per point
Stopped-Flow UnitTriple-/Quadruple-Channel Mixing, Independent Stepper-Motor Control per Channel
Minimum Injection Volume10 µL
Flow Rate per Channel0.01–1.0 mL/s
Mixing Ratio RangeContinuously Adjustable from 1:1 to 1:100
Minimum Dead Time0.25 ms (with micro-volume detection cell)
Expandable ModulesCryo-Quench, Sub-Zero Stopped-Flow, Temperature-Jump (T-Jump), Auto-Titration, In-Situ Micro-Conductivity Detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-logic
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEKKO
Price RangeUSD 68,000 – 136,000 (est.)
Instrument TypeCircular Dichroism (CD) Spectrometer
Wavelength Range185–850 nm
Spectral Bandwidth1 nm (full range)
Noise Level≤ 0.05 mdeg
Plate FormatsStandard 96-well microplates (optional 384-well support)
Modulation Frequency50 kHz
Single-Wavelength Throughput~2 min per 96-well plate
Multi-Wavelength Scan (e.g., 210–350 nm, 5 nm step)~30 sec per well (~50 min total)
Full-Spectrum Scan (185–850 nm, 1 nm step)~11 min per well (~18 h total)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBioTools
OriginUSA
ModelChiralIR-2X
Instrument TypeVibrational Circular Dichroism (VCD) Spectrometer
Spectral Range4000–850 cm⁻¹ (standard), optional extension to 10,000 cm⁻¹ (NIR)
Baseline Drift< 2 × 10⁻⁵ AU
Signal-to-Noise Ratio>3.6× improvement over single-source systems
Detector Continuous Operation30–48 hours
Optical PathFully automated alignment and calibration
Data AcquisitionDigital signal processing (no lock-in amplifiers or analog filtering required)
Sample StageSyncRoCell™ rotating sample cell platform
DualPEM™ capabilityOptional upgrade for solid-sample VCD correction
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0