| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | BS-2F |
| Price | USD 2,650 (FOB) |
| Temperature Range | 5–50 °C |
| Temperature Uniformity | ±0.8 °C (at 37 °C, steady state) |
| Humidity Control | Uncontrolled (non-humidified) |
| Chamber Capacity | 110 L (470 mm × 370 mm × 2-tier platform) |
| Oscillation Mode | Orbital (optional reciprocating conversion kit available) |
| Stroke Amplitude | 20 mm |
| Speed Range | 40–260 rpm |
| Temperature Accuracy | ±0.5 °C |
| Heating Power | 600 W |
| Timer Range | 1–999 min |
| Fan System | Brushless DC axial fan with forced-air convection |
| Interior Material | 304 stainless steel |
| Insulation | Polyurethane foam (≥50 mm thickness) |
| Viewing Window | Double-layer tempered glass with anti-fog coating |
| Control System | Microprocessor-based PID controller with LED digital display |
| Brand | BURKARD |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Univac |
| Price Range | USD 2,600 – 6,500 |
| Temperature Control Range | 60 °C (operational ambient range, not incubation) |
| Temperature Uniformity | ±0.5 °C (ambient stability during field operation) |
| Humidity Handling Capacity | Up to 95% RH (non-condensing) |
| Collection Chamber Volume | 108 mL (standard perforated aluminum collector cup) |
| Vacuum Output | >150 inH₂O (37.3 kPa) |
| Motor Max Speed | 7,000 rpm |
| Fuel Tank Capacity | 1.25 L |
| Net Weight | 11 kg |
| Dimensions (L×W×H) | 45 × 33 × 51 cm |
| Sampling Hose | 1.83 m (6 ft), 6 cm ID reinforced transparent PVC |
| Turbine Stages | 4-stage axial-flow |
| Ignition System | Electronic spark ignition |
| Exhaust Configuration | Rear-mounted muffler with directional exhaust ducting |
| Brand | — |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | BXP-65S |
| Price | Upon Request |
| Temperature Range | RT+5 °C to 100 °C |
| Temperature Uniformity (at 60 °C) | ±0.6 °C |
| Temperature Fluctuation (at 60 °C) | ±0.3 °C |
| 30-Second Recovery Time (at 60 °C) | 14 min |
| Heating Time to 60 °C | 16 min |
| Rated Power | 0.55 kW |
| Inner Chamber Dimensions (W×D×H) | 410 × 350 × 450 mm |
| External Dimensions (W×D×H) | 575 × 608 × 637 mm |
| Standard Shelves | 2 (max. 5) |
| Stackable | Yes (up to 2 units) |
| Interface Ports | 2 × RS-485, 1 × USB |
| Brand | Chengmeng |
|---|---|
| Origin | Taicang, Jiangsu, China |
| Model | DHZ-LA |
| Instrument Type | Refrigerated Orbital Shaking Incubator |
| Drive System | Brushless DC Motor |
| Speed Range | 10–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4°C to 60°C (at 25°C ambient) |
| Temperature Stability | ±0.1°C |
| Temperature Uniformity | ±0.5°C |
| Chamber Volume Capacity | 250 mL × 60, or 500 mL × 40, or 1000 mL × 24, or 2000 mL × 15, or 3000 mL × 8, or 5000 mL × 8 (with fixed-position stainless-steel clamps) |
| External Dimensions | 1200 × 780 × 960 mm (L×W×H) |
| Power Consumption | 1200 W |
| Input Voltage | 220 V, 50 Hz |
| Interior Material | Full 304 Stainless Steel |
| Exterior Finish | Electrostatically Powder-Coated Cold-Rolled Steel |
| Timer Range | 0–9999 min |
| Lighting | 8 W LED Illumination Lamp |
| UV Sterilization Lamp | 8 W |
| Safety Features | Door-Interlocked Operation, Power-Fail Memory & Auto-Restart, Over-Temperature Alarm, Sensor Fault Detection, Motor Fault Diagnostics (stall, Hall error, bus voltage anomaly, communication failure) |
| Control System | Microprocessor-Based PID Temperature Control + Dual-Loop (Speed + Current) Motor Control |
| Optional | USB Data Export Port, Adjustable Height Levelling Feet with Casters, Universal Spring Shelf (user-selectable) |
| Brand | Chu Ding |
|---|---|
| Model | HH.CP-TW |
| Type | Water-Jacketed Constant-Temperature CO₂ Incubator |
| Capacity | 80 L |
| Temperature Range | RT+5°C to 50°C |
| Temp. Uniformity | ±0.2°C |
| Temp. Resolution | 0.1°C |
| CO₂ Range | 0–20% |
| CO₂ Control | Infrared Sensor (IR) with Microprocessor Regulation |
| Heating Method | Water Jacket |
| Humidification | Natural Evaporation |
| Power Input | 680 W |
| Internal Dimensions (W×D×H) | 400×400×500 mm |
| External Dimensions (W×D×H) | 550×550×800 mm |
| Standard Shelves | 2 pcs |
| Filtration | 0.3 µm HEPA-grade CO₂ Inlet Filter (99.99% efficiency) |
| Door Heating System | Yes |
| Optional | UV Sterilization Lamp, Independent Over-Temp Alarm, Data Logging via RS485/USB |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | DHP-360S |
| Power Supply | 220 V AC, 300 W |
| Interior Dimensions (W×D×H) | 420 × 360 × 360 mm |
| Exterior Dimensions (W×D×H) | 460 × 445 × 770 mm |
| Temperature Control Range | Ambient +5 °C to 60 °C |
| Control Type | Digital PID Controller with LED Display |
| Chamber Material | Painted Steel (Standard) / Optional Stainless Steel (B variant) |
| Door Seal | Silicone Rubber or Magnetic Gasket |
| Viewing Window | Double-Layer Tempered Glass |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGZ-400 |
| Power Supply | AC 220 V, 50 Hz |
| Temperature Range (with light) | 10–50 °C |
| Temperature Range (without light) | 4–50 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Illumination Intensity | 0–25,000 lx, 6-step adjustable |
| Light Source | T4 fluorescent tubes, triple-sided illumination |
| Internal Volume | 400 L |
| Internal Dimensions (W×D×H) | 680 × 550 × 1050 mm |
| External Dimensions (W×D×H) | 880 × 780 × 1810 mm |
| Input Power | 2500 W |
| Standard Shelves | 3 pcs |
| Operating Environment | 5–30 °C |
| Continuous Operation | ≥360 h |
| Safety | Dual-compressor auto-switching, over-temperature cut-off with audible/visual alarm |
| Control System | Microprocessor-based PID control, 99-cycle programmable sequence (30 segments/cycle, up to 99 h 59 min/segment) |
| Data Interface (optional) | USB or RS485 for printer/computer connectivity |
| Interior Material | Mirror-finish stainless steel, rounded corners |
| Insulation | Double-door structure with high-efficiency thermal barrier |
| Refrigerant | R134a / R406A (non-ozone-depleting, low-GWP) |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | HQH-400 / HQH-250 |
| Temperature Range (with light) | 10–50 °C |
| Temperature Range (dark) | 4–50 °C |
| Humidity Range | 50–90 %RH |
| Humidity Deviation | ±5–7 %RH |
| Illumination Intensity | 0–25,000 lx (6-level adjustable, HQH-400) / 0–15,000 lx (HQH-250) |
| Temperature Uniformity | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Power Input | 3200 W (HQH-400) / 2500 W (HQH-250) |
| Chamber Volume | 400 L (HQH-400) / 250 L (HQH-250) |
| Internal Dimensions (W×D×H) | 680×550×1050 mm (HQH-400) / 580×500×850 mm (HQH-250) |
| Refrigerant | R134a / R406a (CFC-free) |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | LHS-250SC |
| Capacity | 250 L |
| Temperature Range | RT+10°C to 85°C (with humidity control: 15–45°C |
| without humidity | 10–45°C) |
| Humidity Range | 40–85% RH |
| Temperature Uniformity | ±1.0°C (±0.5°C at high temp, ±1.5°C at low temp) |
| Temperature Resolution | 0.1°C |
| Humidity Control Accuracy | ±3% RH (typical, @25°C/60% RH, empty chamber) |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 730 W |
| Internal Dimensions (W×D×H) | 580 × 500 × 850 mm |
| External Dimensions (W×D×H) | 705 × 725 × 1525 mm |
| Standard Shelves | 2 pcs |
| Programmable Cycles | 99 cycles × 30 segments × 99 h 59 min per segment |
| Control System | PID-based digital controller with LCD interface |
| Refrigerant | R134a / R406a (CFC-free, ozone-safe) |
| Construction | Mirror-finish stainless steel interior, double-glazed insulated door, adjustable shelf spacing |
| Air Circulation | JAKEL centrifugal fan with optimized duct design |
| Humidification System | Built-in water reservoir with immersed heating element |
| Optional Interfaces | RS485, USB |
| Compliance | Designed for GLP-compliant environmental simulation |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | LHS-300HC |
| Power Supply | AC 220 V, 50 Hz |
| Temperature Range | RT+10 °C to 85 °C (heating only) |
| Humidity Range | 40–85 % RH |
| Temperature Uniformity | ±1 °C (typical, empty chamber, 20 °C ambient) |
| Temperature Resolution | 0.1 °C |
| Humidity Control Accuracy | ±3–5 % RH (dependent on setpoint and ambient conditions) |
| Chamber Volume | 300 L |
| Internal Dimensions (W×D×H) | 580 × 540 × 950 mm |
| External Dimensions (W×D×H) | 705 × 765 × 1640 mm |
| Input Power | 2000 W |
| Standard Shelving | 3 adjustable stainless steel shelves |
| Programmable Cycles | 99 cycles × 30 segments × 99 h 59 min per segment |
| Refrigerant | R134a / R406a (non-ozone-depleting, low-GWP HFC blend) |
| Compliance | Designed for GLP-compliant environmental simulation |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | LRH-150F |
| Power Supply | AC 220 V, 50 Hz |
| Temperature Range | 0–60 °C |
| Temperature Uniformity | ±0.5 °C (at high temp), ±1.0 °C (at low temp) |
| Temperature Resolution | 0.1 °C |
| Rated Power | 1250 W |
| Chamber Dimensions (W×D×H) | 580 × 540 × 950 mm |
| External Dimensions (W×D×H) | 705 × 765 × 1640 mm |
| Nominal Volume | 150 L |
| Standard Shelves | 3 pcs |
| Timer Range | 1–9999 min |
| Refrigerant | R134a / R406a (fluorine-free) |
| Safety Features | Over-temperature cut-off with audible/visual alarm |
| Control System | PID temperature control |
| Optional | Multi-segment programmable controller (15 segments / 30 steps), USB/RS485 data interface, 25 mm or 50 mm test port |
| Brand | Chuanheng Instrument |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Range | 0.1–95% vol (±0.3% accuracy) |
| Temperature Range | 5–60°C (±0.2°C stability at 37°C, ±0.8°C uniformity) |
| CO₂ Range | 0–20% vol (±0.1% accuracy, IR sensor-based) |
| Humidity Range | 50–95% RH |
| Capacity Options | 50 L / 80 L / 100 L / 160 L / 200 L |
| Standard Configuration | UV Sterilization, PT100 Temperature Sensing, Electromagnetic Gas Valve Interlock, Micro-Circulation Airflow System, Touchscreen Interface (5″ LCD), Dual-Stage Overtemperature & Gas Safety Cutoffs |
| Brand | Chuanheng Instrument |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Method | Air-Jacketed |
| Cooling Method | Compressor-Based Refrigeration |
| Convection Type | Forced Air Circulation |
| Temperature Range | 4°C to 60°C |
| Temperature Accuracy | ±0.5°C |
| Temperature Uniformity | ±1.0°C |
| Chamber Capacity | 50 L × 3 independent chambers |
| External Dimensions | 550 × 915 × 1700 mm |
| Internal Dimensions (per chamber) | 450 × 350 × 350 mm |
| Display Resolution | 0.1°C |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 1200 W |
| Exterior Material | SUS#304 Mirror-Finish Stainless Steel |
| Insulation | High-Density Polyurethane Foam (in-situ foamed) |
| Control System | Microprocessor-Based Controller with LCD Touch Interface |
| Safety Features | Dual Independent Thermal Protection (Electronic Over-Temp Cut-off + Mechanical Backup Fuse) |
| Brand | Chuanheng Instrument |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PGX-1000C |
| Illumination Method | Triple-Side LED Lighting |
| Light Source | High-Efficiency White LED Array |
| Spectral Range | Visible Spectrum (400–700 nm) |
| Temperature Control Range | 0–60 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Illuminance Range | 22,000 lux |
| Light Intensity Adjustment | 5-Step Digital Control |
| Chamber Volume | 1000 L |
| Brand | Chuanhong |
|---|---|
| Origin | Shanghai, China |
| Model | MJX-600 |
| Capacity | 600 L |
| Temperature Range | 0–50 °C |
| Temperature Uniformity | ±0.8 °C |
| Humidity Control | Not equipped (0% RH control) |
| Construction | Dual-door design, triple-layer hollow glass viewing windows, stainless steel interior chamber, mechanical lock |
| Brand | Chuanhong |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZKST-2 |
| Price | Upon Request |
| Chamber Material | 3 mm SUS304 Stainless Steel |
| Viewing Window | 8–10 mm Tempered Glass |
| Gas Valves | 304 Stainless Steel Ball Valves with Integrated Inlet/Outlet Fittings |
| Internal Lighting | UV-Free White LED |
| Power Supply | Multi-Port Industrial Socket (220 V AC) |
| Gloves | Industrial-Grade Acid-Resistant Latex with O-Ring Seals |
| Optional Upgrades | KF-25/KF-40 Vacuum Flange Interfaces |
| Main Chamber Dimensions (W×D×H) | 600 × 450 × 420 mm |
| Transfer Airlock Options | Ø210 mm / 240 L / 260 L Cylindrical Designs |
| Door Mechanism | Semi-Automatic Hinged Door |
| Brand | Chuanna Instrument |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +5°C to 65°C |
| Temperature Uniformity | ±0.2°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% |
| Chamber Capacity | 80 L |
| Standard Configuration | 90°C Humidified Sterilization Cycle |
| Brand | Chuanna Instrument |
|---|---|
| Origin | Shanghai, China |
| Model | PRX-80B |
| Type | Semi-Automatic Incubator |
| Capacity | 80 L |
| Temperature Range | 0–50 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 50–95 %RH |
| Humidity Uniformity | ±2 %RH |
| Illumination Intensity | 12,000 lx |
| External Dimensions (W×D×H) | 625×545×1085 mm |
| Brand | Chuanna Instrument |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YQX-II |
| Instrument Type | Manual Anaerobic Incubator |
| Oxygen Concentration | <0.1% O₂ (maintained via catalytic deoxygenation and gas replacement) |
| Temperature Control Range | RT+3°C to 50°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Gas Supply | Pre-mixed anaerobic gas (85% N₂ / 10% H₂ / 5% CO₂ |
| Cultivation Chamber Dimensions (W×D×H) | 200 × 190 × 260 mm |
| Operation Chamber Dimensions (W×D×H) | 760 × 630 × 620 mm |
| External Dimensions (W×D×H) | 1200 × 730 × 1330 mm |
| Power Supply / Rated Power | 220 V, 50 Hz / 600 W |
| Anaerobic Establishment Time (Operation Chamber) | <60 min |
| Anaerobic Maintenance Duration (without gas replenishment) | ≥12 h |
| Vacuum Sampling Chamber Deoxygenation Time | <5 min |
| Brand | Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Range | 1–95% (v/v), programmable in 0.1% increments |
| CO₂ Range | 0–20% (v/v), ±0.1% accuracy |
| Temperature Range | RT+3°C to 60°C, ±0.1°C setpoint stability |
| Temperature Uniformity | ±0.3°C at 37°C |
| Humidity | ≥90% RH (passive humidity maintenance via integrated water pan |
| Chamber Volume | 50 L |
| External Dimensions (W×D×H) | 430 × 460 × 650 mm |
| Display & Interface | 7-inch capacitive TFT touchscreen with multi-language UI (English default) |
| Gas Delivery | Triple independent mass flow controllers (MFCs) for O₂, CO₂, and N₂ |
| Certifications | CE-marked per IEC 61010-1 |
| Brand | Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | MJX-2000S |
| Price Range | USD 2,800 – 7,000 |
| Temperature Range | 0–50 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 30–95% RH |
| Humidity Accuracy | ±5% RH |
| Chamber Capacity | 2000 L |
| Control System | Microprocessor-based dual PID control with touch interface |
| Display | Dual digital LED (temperature & humidity) |
| Humidification Method | Ultrasonic humidification |
| Insulation | Triple-layer hollow tempered glass door |
| Interior Material | Stainless steel (AISI 304) |
| Safety Features | Over-temperature protection, sensor fault detection, compressor thermal overload protection |
| Programmability | Up to 30 segment time-temperature profiles |
| Data Retention | Non-volatile memory for parameter backup during power interruption |
| Brand | Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Model | YQX-II |
| Price Range | USD 1,400–2,800 (FOB) |
| Temperature Control Range | Ambient +3°C to 50°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Anaerobic Chamber Establishment Time (Operation Room) | <60 min |
| Sample Transfer Chamber Anaerobiosis Achievement Time | <5 min |
| Anaerobic Maintenance Duration (without gas replenishment) | ≥12 h |
| Chamber Dimensions (D×W×H) | 800×550×650 mm |
| Overall Dimensions (D×W×H) | 1200×730×1300 mm |
| Power Supply | 220 V, 50 Hz / 600 W |
| Gas Mixture Ratio | N₂ 85% / H₂ 5% / CO₂ 10% |
| Nitrogen Purity | ≥99.9% |
| UV Sterilization Lamp | Integrated |
| Stainless Steel Construction | 304 SS for Chamber Walls & Transfer Port |
| Viewing Window | Impact-Resistant Tempered Glass with Dual-Sealed Glove-Free Sleeve Ports |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | HWS-450BC |
| Heating Method | Air-jacketed heating |
| Cooling Method | Compressor-based refrigeration |
| Humidification System | External ultrasonic humidifier tank |
| Temperature Range (with humidity) | 10–50 °C |
| Temperature Range (dry operation) | 0–50 °C |
| Temperature Fluctuation | ±0.5–1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 50–95 %RH |
| Humidity Accuracy | ±5–8 %RH |
| Capacity | 450 L |
| Internal Dimensions | 600 × 600 × 1250 mm |
| Overall Dimensions | 700 × 790 × 1850 mm |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SPX-350B |
| Temperature Range | 0–60 °C |
| Internal Dimensions (W×D×H) | 500 × 560 × 1280 mm |
| External Dimensions (W×D×H) | 600 × 670 × 1918 mm |
| Temperature Uniformity | ±1 °C |
| Temperature Stability | ±0.5 °C |
| Control System | PID-controlled digital microprocessor with dual LED display (set & actual temperature) |
| Sensor | PT100 platinum resistance thermometer |
| Refrigeration | Eco-friendly R134a compressor-based cooling module with high/low pressure protection and delayed start |
| Air Circulation | Forced convection via stainless steel duct system |
| Interior Material | Mirror-finish 304 stainless steel chamber with adjustable, removable shelves |
| Viewing Window | Large-angle tempered glass observation window with interior LED lighting |
| Safety Features | Over-temperature alarm, timer function, auto cut-off protection |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | PRX-1200C |
| Type | Fully Automatic Programmable Incubator |
| Capacity | 12000 L |
| Temperature Range | 0–50 °C |
| Temperature Uniformity | ±1.5 °C |
| Humidity Range | 50–95 %RH |
| Humidity Uniformity | ±5–8 %RH |
| Illumination Intensity | 0–22000 lx |
| External Dimensions | 1500 × 860 × 1880 mm |
| Brand | Chuanyu Yiqi |
|---|---|
| Origin | Shanghai, China |
| Model | MJX-250 |
| Capacity | 250 L |
| Temperature Range | 0–60 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Control | Optional (50–95% RH, ±5–8% RH fluctuation) |
| Construction | Mirror-finish stainless steel chamber, electrostatically coated exterior, double-glazed magnetic door seal |
| Cooling System | Hermetically sealed compressor with eco-friendly refrigerant (R134a or equivalent) |
| Control System | LCD PID controller with real-time setpoint/actual value display, programmable timer (0–999 h/min), auto-restart after power failure, over-temperature alarm, temperature calibration function, and UV sterilization lamp |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | YQX-II |
| Instrument Type | Manual Anaerobic Incubator with Microaerophilic Capability |
| Oxygen Concentration Range | ≤1% (Anaerobic) / Adjustable 2–10% (Microaerophilic) |
| Temperature Control Range | Ambient +3°C to 50°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| Operating Chamber Dimensions | 800 × 550 × 650 mm (W×D×H) |
| Gas Supply Options | Single-gas (premixed 10% H₂ + 10% CO₂ + 80% N₂) or Dual-gas (pure N₂ + premixed gas) |
| Deoxygenation Time (Operation Chamber) | <60 min |
| Anaerobic Maintenance Duration (without gas replenishment) | ≥12 h |
| Power Supply | 220 V, 50 Hz / 1000 W |
| UV Sterilization Lamp | Integrated |
| Catalytic Oxygen Scrubber | Built-in |
| Casters with Locking Brakes | Yes |
| Compliance | Designed for ISO 13485-aligned lab workflows |
| Brand | Chuanyu |
|---|---|
| Origin | Shanghai, China |
| Model | ZDX-100-CO₂ |
| Instrument Type | Air-jacketed CO₂ incubated shaker |
| CO₂ Detection | Infrared (IR) sensor |
| Temperature Range & Accuracy | RT + 5°C to 50°C, ±0.5°C |
| Temperature Uniformity | ±1.0°C |
| CO₂ Concentration Range & Accuracy | 0–20% v/v, ±0.5% |
| Humidity Range & Accuracy | 40–95% RH |
| Capacity | 100 L |
| External Dimensions (W×D×H) | 500 × 500 × 400 mm |
| Tray Size | 200 × 200 mm |
| Speed Range | 40–300 rpm |
| Orbit Diameter | ≥20 mm |
| Sterilization | Built-in UV lamp |
| Control Interface | Microprocessor-based LCD with menu-driven operation |
| Power Backup Function | Power-loss memory and automatic time compensation |
| Safety Features | Over-temperature alarm, real-time CO₂ monitoring, insulated tempered-glass door |
| Origin | Poland |
|---|---|
| Type | Forced-Air Incubator |
| Model | CLW750 |
| Temperature Range | +5 °C to +100 °C |
| Temperature Uniformity | ±0.4 °C |
| Humidity Range | 20–60 %RH |
| Capacity | 749 L |
| Internal Dimensions (W×D×H) | 1040 × 600 × 1200 mm |
| External Dimensions (W×D×H) | 1255 × 810 × 1620 mm |
| Shelf Capacity | 5 standard / up to 16 adjustable stainless-steel shelves |
| Power Consumption | 1800 W |
| Net Weight | 260 kg |
| Gross Weight | 315 kg |
| Control System | Microprocessor-based, 6-step programmable, with RS232C interface and power-fail parameter retention |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 39350-05 |
| Chamber Volume | 566 L |
| Temperature Range | −10 to 50 °C (lamp off) |
| Temperature Uniformity | ±0.9 °C at −10 °C, ±0.5 °C at 20 °C, ±0.6 °C at 50 °C |
| Temperature Accuracy | ±0.1 °C |
| Air Circulation | Forced-air mechanical convection |
| Control System | Microprocessor-based with high-limit/low-limit safety cutoff and digital temperature calibration |
| Interface | RS232 serial port |
| Lighting | Two 1.2 m T8 fluorescent lamps (included) |
| Timer Function | Programmable 7-day schedule with up to two heating/light cycles per day |
| Shelving | 6 adjustable stainless-steel shelves |
| Internal Dimensions (W×H×D) | 67.3 × 144.8 × 50.8 cm |
| External Dimensions (W×H×D) | 70 × 191 × 66 cm |
| Power Supply | 230 V, 50/60 Hz, 800 W |
| Weight | 158 kg |
| Data Logging Port | Standard analog output connector for external recorder |