| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SKYSCAN 1273 |
| X-ray Source Energy | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel, 3072 × 1944 pixels |
| Spatial Resolution | < 5 µm (3D) |
| Voxel Size | < 3 µm |
| Maximum Sample Dimensions | Ø300 mm × H500 mm, up to 20 kg |
| Field of View | Ø250 mm × H250 mm |
| Image Matrix | up to 4800 × 4800 pixels |
| Detector Output Speed | High-frame-rate acquisition enabled |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1273 |
| X-ray Source | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel (3072 × 1944 pixels) |
| Spatial Resolution | < 5 µm |
| Voxel Size | < 3 µm |
| Max Sample Dimensions | Ø250 mm × H250 mm |
| Max Sample Weight | 20 kg |
| Reconstructed Volume | up to 4800 × 4800 pixels |
| External Dimensions | 1250 × 815 × 820 mm (W × D × H) |
| Radiation Leakage | < 1 µSv/h at any point on external surface |
| Power Supply | 100–240 V, 50–60 Hz, 3 A |
| Weight | 400 kg (net) |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan 1275 |
| X-ray Source | 20–100 kV, 10 W, < 5 µm focal spot size at 4 W |
| Detector | 3 MP CMOS flat-panel detector (1944 × 1536 effective pixels) |
| Spatial Resolution | < 4 µm (nominal, at maximum magnification) |
| Density Resolution | < 4 µm (nominal, inferred from spatial resolution and contrast transfer performance) |
| Sample Capacity | Max height 120 mm, max diameter 96 mm |
| Dimensional Measurement Accuracy | Consistent with < 4 µm spatial resolution under calibrated conditions |
| Density Measurement Accuracy | Supported by high dynamic range (16-bit) detector and beam-hardening correction algorithms |
| Power Requirement | Standard 230 V AC, 50/60 Hz, single-phase outlet |
| Radiation Safety | Compliant with IEC 61000-6-3, IEC 61000-6-4, and national regulatory requirements for Class II B radiation devices |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 2211 |
| X-ray Source | 20–190 kV, 4/10/25 W, sub-micron focal spot size, 5-position filter wheel |
| X-ray Target | Tungsten (standard) |
| Detector | 3 MP CMOS flat panel (1920 × 1536 px) or 11 MP cooled CCD (4032 × 2670 px) |
| Reconstruction Volume (CMOS) | up to 3776 × 3776 × 1160 px (dual offset mode) |
| Reconstruction Volume (CCD) | up to 8000 × 8000 × 2272 px (dual offset mode) |
| Spatial Resolution | down to 100 nm (detector-limited, geometry-dependent) |
| Sample Capacity | Ø204 mm × L200 mm, max. 25 kg |
| Sample Positioning | direct-drive air-bearing rotation stage with integrated piezo-driven micro-positioning (5.5 mm travel) |
| Reconstruct Time | 1 min 12 sec (600 projections, 2K × 2K × 1K) |
| Radiation Safety | <0.5 µSv/h at 10 cm from surface (measured at 190 keV, 4 W on target) |
| Power Supply | 100–130 V or 200–240 V AC, 50–60 Hz |
| Cooling & Air Supply | integrated closed-loop water chiller and oil-free air compressor with particle filters and desiccant dryer |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Voxel Resolution | <0.35 µm (16 MP detector) / <0.45 µm (11 MP detector) |
| Max Reconstructed Volume | 14456 × 14456 × 2630 px (16 MP) or 11840 × 11840 × 2150 px (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm (standard) |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Spatial & Density Resolution | <0.35 µm (16 MP) / <0.45 µm (11 MP), isotropic voxel capability |
| Reconstruction Engine | InstaRecon® real-time GPU-accelerated 3D reconstruction |
| Scan Modes | Cone-beam, helical, phase-contrast enabled, dynamic time-lapse |
| Compliance | Fully compatible with ASTM E1441, ISO 15732, and USP <1059> for non-destructive volumetric analysis |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Reconstruction Volume | 14456 × 14456 × 2630 px (16 MP detector) or 11840 × 11840 × 2150 px (11 MP detector) |
| Spatial Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Density Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution Scientific CMOS Sensor |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | 2 µm |
| Density Resolution | <1% |
| X-ray Energy | 110 kV |
| Maximum Sample Dimensions | Ø110 mm × 300 mm (H) |
| Max Sample Weight | 5 kg |
| System Footprint | 1250 × 960 × 690 mm (L × D × H) |
| Precision Level | Nanoscale |
| Configuration | Modular Benchtop Micro-CT Platform |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution sCMOS Semiconductor Sensor |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | ≤2 µm (JIMA-verified) |
| System Architecture | Modular, Field-Upgradable |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CoreScanner |
| Pricing | Upon Request |
| Brand | Dragonfly |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dragonfly 3D World |
| Detector Type | Multi-Modal Volumetric Data Input |
| Scanning Method | Translation-Rotation (TR) Compatible |
| Resolution | Sub-nanometer (data-dependent) |
| X-ray Energy Range | 10 keV – 9 MeV |
| Imaging Dimensions | 2D, 3D, and Time-Resolved 4D |
| Dimensional Measurement Accuracy | Up to 1 nm (system-limited) |
| Physical Footprint | Software-Only Deployment |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | DEMT-8/16 |
| Detector Type | Custom Electromagnetic Sensor Array |
| Spatial Resolution | 5% of cross-sectional diameter |
| Density Resolution | Configurable (system-dependent) |
| Penetration Capability | Customizable per application |
| Measurement Range | Configurable (up to Ø300 mm cross-section) |
| Dimensional Accuracy | ±5% of cross-sectional dimension |
| Density Measurement Accuracy | Configurable |
| Operating Temperature | Up to 300 °C (non-contact probe interface) |
| Imaging Modes | Dual-mode (Eddy Current Tomography & Metal Flaw Detection) |
| Signal-to-Noise Ratio (SNR) | 60–90 dB |
| Frequency Range | 1 kHz–200 kHz (standard) |
| Channel Configuration | 8 or 16 independently configurable channels |
| Sampling Rate | Up to 100 kS/s per channel (flaw detection mode) |
| Reconstruction Grid | Up to 32×32 pixels (1% cross-sectional area resolution) |
| Front-End Signal Processing | Programmable 3-stage gain amplifier (1×–8×), with optional expansion |
| Data Output | Complex impedance components (real, imaginary, magnitude, phase), full complex-plane representation |
| Core Platform | FPGA-based digital acquisition and real-time processing architecture |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FISCHERSCOPE PMP10 |
| Pricing | Available Upon Request |
| Measurement Principle | Micro-Resistance (4-Point Probe) |
| Thickness Range | 0–120 µm |
| Accuracy | ±0.5 µm (5–50 µm), ≤1% of reading (50–80 µm), ≤2% of reading (>80 µm) |
| Test Area | 10 × 15 mm |
| Compliance | ISO 2178, ASTM B499, IPC-4552A, RoHS-compliant design |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | C7942CA-22 |
| Pixel Array | 2400 × 2400 |
| Pixel Size | 50 µm × 50 µm |
| Active Area | 120 mm × 120 mm |
| Scintillator | CsI (Thallium-doped) |
| Bit Depth | 12-bit digital output |
| Frame Rate | 2 fps (full resolution), 9 fps (4×4 binning) |
| Dynamic Range | 2000:1 (typical) |
| X-ray Resolution | 8 lp/mm (typical, at 25 °C) |
| Output Interface | RS-422 |
| Noise Performance | Low-noise architecture with high signal-to-noise ratio (SNR) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | S8658-01 / S8658-01F |
| Frame Rate (typ.) | 15 fps |
| Active Image Area (per chip) | 73.728 mm × 6.144 mm |
| Pixel Pitch | 48 µm |
| Total Pixels | 4608 × 128 (3 × 1536 × 128) |
| Pixel Size | 48 µm × 48 µm |
| Fill Factor | 100% |
| Scintillator | CsI(Tl) + Fiber Optic Plate (FOP) (S8658-01) / FOP only, no scintillator (S8658-01F) |
| Package | Ceramic |
| TDI Mode | Supported |
| Dynamic Range | Wide |
| Dark Current | Low |
| Operation Mode | MPP (Multi-Pinned Phase) |
| Brand | Hexagon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Super Volume 225 |
| Detector Type | High-Resolution CMOS Semiconductor Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | 4 µm |
| Density Resolution | ≤0.1 µm (minimum detectable density variation) |
| X-ray Source | 225 kV Microfocus Tube |
| Penetration Capability | High (suitable for dense metals and composites) |
| Measurement Volume | 427 mm × 427 mm (max. field of view) |
| Dimensional Measurement Accuracy | (4.5 + L/50) µm (L in mm) |
| Density Measurement Accuracy | (4.5 + L/50) µm (L in mm) |
| Maximum Sample Weight | 10,500 kg |
| System Dimensions | 3520 mm × 2050 mm × 2700 mm |
| Radiation Shielding | Integrated self-shielding cabinet compliant with GBZ 117–2020 (Chinese national radiation safety standard) |
| Brand | AOLONG |
|---|---|
| Model | BatteryCT |
| Type | Industrial Micro-Computed Tomography System |
| Origin | Liaoning, China |
| Manufacturer | OEM Producer |
| X-ray Max Power | 320 W |
| X-ray Max Voltage | 225 kV |
| X-ray Max Current | 3 mA |
| Focal Spot Size | 4 µm |
| Beam Divergence Angle | 30° |
| Flat-Panel Detector Pixel Pitch | 139 µm |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XRF Scanner |
| Pricing | Upon Request |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BrillianSe |
| Quotation | Upon Request |
| Detector Type | High-Resolution CMOS Semiconductor Chip |
| Scanning Method | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| X-ray Energy Range | Up to 120 kV |
| Spatial Resolution | Up to 5.6 µm (0.1 MTF at 90 cycles/mm) |
| Dimensions | 269 mm × 245 mm × 117 mm (L × W × H) |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Model | inCiTe 3D |
| Detector Type | High-Resolution CMOS-Based Direct-Conversion a-Se (BrillianSe) Sensor |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | Up to 5.6 μm (0.1 MTF at 90 cycles/mm) |
| X-ray Energy Range | 40–110 kV |
| Field of View | 32 mm × 32 mm (direct detection) |
| Maximum Sample Dimensions | Ø25 mm × 100 mm (diameter × height/length) |
| System Footprint | 1500 mm × 580 mm × 500 mm (L × W × H) |
| Pixel Pitch | 8 μm |
| Detector Resolution | 4096 × 4096 (16.8 MP) |
| Effective DQE | High across 40–120 keV |
| Phase-Contrast Mechanism | Propagation-Based (Grating-Free, In-Line) |
| Minimum Focal Spot Size | 2 μm |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | inCiTe |
| Detector Type | High-Resolution CMOS-Based Direct-Conversion Semiconductor Detector (BrillianSe™) |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | Up to 5.6 µm (0.1 MTF at 90 cycles/mm) |
| X-ray Source Spot Size | ≤5 µm |
| X-ray Energy Range | 40–100 kV |
| Maximum Sample Volume | Ø25 mm × 100 mm (diameter × height/length) |
| System Dimensions | 1500 mm × 580 mm × 500 mm (L × W × H) |
| Pixel Pitch | 8 µm |
| Detector Format | 16 MP (4096 × 4096) |
| Field of View | 32 mm × 32 mm |
| Phase-Contrast Mechanism | Propagation-Based (Grating-Free, In-Line) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC-01 |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AXR |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AXR |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Model | X3305 |
| IP Rating | IP65 (standard), IP69K (optional) |
| X-ray Source Power | 20 W |
| System Length | 1.8 m |
| Compliance | GMP, NSF/ANSI 169, EHEDG Guideline Doc. 8.2 |
| Application Scope | Small-to-medium packaged food, pharmaceutical, and consumer goods |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Model | N60 |
| X-ray Source Energy | 100 kV |
| Detector Type | Flat-panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 8 µm |
| Measurement Field of View | 36 mm × 60 mm |
| Sample Weight Capacity | 20 kg |
| System Dimensions | 800 mm × 310 mm × 375 mm |
| Accuracy | Micron-level |
| Software | Integrated acquisition, reconstruction, quantification & STL export |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Model | N70 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 4 µm |
| X-ray Energy | 100 kV |
| Maximum Sample Dimensions | 100 mm × 120 mm (diameter × height) |
| Max Sample Weight | 20 kg |
| System Dimensions | 1050 mm × 607 mm × 463 mm |
| Accuracy | Micron-Level |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Sample Rotation Only (RO) |
| Spatial Resolution | 2 µm |
| X-ray Energy | 110 kV |
| Field of View | 100 mm × 163 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions | 1200 mm × 640 mm × 520 mm |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 2 µm |
| X-ray Energy | 110 kV |
| Field of View | 100 mm × 163 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions | 1200 mm × 640 mm × 520 mm |
| Precision | Micron-Level |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Sample Rotation Only (RO) |
| Spatial Resolution | 2 µm |
| X-ray Energy | 110 kV |
| Field of View | 100 mm × 163 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions | 1200 mm × 640 mm × 520 mm |
| Precision | Micron-Level |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Model | N80 |
| X-ray Source Energy | 110 kV |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 2 µm |
| Accuracy | Micron-Level |
| Maximum Sample Dimensions | 100 mm × 163 mm (diameter × height) |
| Maximum Sample Weight | 20 kg |
| System Footprint | 1200 mm × 640 mm × 520 mm |
| X-ray Source | Sealed-Tube Transmission Type |