Industrial Process Control Instruments
Filter
Showing 931–960 of 1018 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ROSS pH |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TruDO |
| Price Range | USD 7,000 – 14,000 |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TruFluor DO Sensor |
| Price Range | USD 7,000 – 14,000 |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TrupH |
| Price Range | USD 1,400 – 4,200 |
| Brand | PROCESS INSTRUMENTS |
|---|---|
| Origin | USA |
| Model | CG1000 |
| Type | Portable Oxygen Analyzer |
| Application | Industrial Process Control & Online Monitoring |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Tianyan Instrument Co., Ltd. |
| Model | TY-NIR-HT |
| Temperature Range | 0–500 °C |
| Moisture Range | 0–100 wt% |
| Moisture Accuracy | ±0.2 wt% (under stable composition conditions) |
| Temperature Accuracy | ±1% FS or ±1.5 °C |
| Optical Spot Diameter | 60–75 mm |
| Measurement Height Adjustment Range | 350 mm ± 100 mm |
| Filter Cycle | 1–60 s |
| Number of Calibration Channels | 50 |
| Optical Window | High-borosilicate quartz glass |
| Power Supply | 220 VAC / 50 Hz |
| Power Consumption | 60 W |
| Ingress Protection | IP65 |
| Curve Fitting | Supports >10 auto-calibration points per moisture calibration curve |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-NIR-HT |
| Measurement Principle | Near-Infrared Reflectance Spectroscopy (NIRS) |
| Moisture Range | 0–100% w/w |
| Moisture Accuracy | ±0.2% (dependent on material composition stability) |
| Temperature Monitoring | Integrated infrared port, range 0–500 °C, accuracy ±1% FS or ±1.5 °C |
| Optical Spot Diameter | 60–75 mm |
| Installation Height Range | 350 mm ± 100 mm |
| Sampling Channels | 50 |
| Light Source | Imported high-efficiency NIR source |
| Filter Cycle | 1–60 s adjustable |
| Optical Window | High-borosilicate quartz glass |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 60 W |
| Enclosure Rating | IP65 |
| Calibration Support | Auto-calibration with ≥10 user-defined moisture calibration points |
| Operating Environment | High-temperature industrial settings |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Tianyan Instrument Co., Ltd. |
| Model | TY-NIR-T |
| Measurement Principle | Near-Infrared Reflectance Spectroscopy (NIRS) |
| Measurement Range | 0–100% w/w (water content by weight) |
| Accuracy | ±0.2% w/w (dependent on material homogeneity and spectral stability) |
| Light Source | Imported high-stability NIR LED array |
| Optical Spot Diameter | 60–75 mm |
| Working Distance | 350 mm ± 100 mm |
| Spectral Channels | 50 discrete wavelength bands |
| Filter Integration Time | 1–60 s adjustable |
| Probe Window Material | High-borosilicate quartz glass |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Enclosure Rating | IP65 |
| Power Supply | 220 VAC, 50 Hz |
| Output Interfaces | RS485, 4–20 mA analog, RS232, Ethernet (LAN), LoRa wireless |
| Display | Integrated industrial-grade capacitive touchscreen |
| Probe Housing | Anodized aluminum alloy (ASTM B557-19 compliant) |
| Signal Processing | Full digital signal chain with adaptive noise filtering and baseline correction |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TY-X3M |
| Price | USD 495 (FOB Shandong) |
| Measurement Principle | Transit-time Ultrasonic Flow Measurement |
| Pipe Material Compatibility | Metallic (e.g., carbon steel, stainless steel, copper) and Non-metallic (e.g., PVC, PP, PE, PTFE-lined) Pipes |
| Nominal Pipe Size Range | DN6–DN200 (OD 9.53–220 mm) |
| Fluid Temperature Range | –10°C to +50°C |
| Ambient Temperature Range | –10°C to +50°C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Accuracy | ±2.0% of reading (flow velocity 0.3–5.0 m/s) |
| Repeatability | ±0.8% |
| Response Time | 500 ms |
| Display | 1.54″ 240×240 IPS LCD, 4-directional rotation |
| Power Supply | 24 VDC @ 3 W |
| Output Signals | 4–20 mA (max. load 600 Ω), RS485 Modbus RTU, Pulse/OCT (optional) |
| Enclosure Rating | IP54 / IP65 (optional housing) |
| Wetted Materials | Non-contact (no wetted parts) |
| Viscosity Limit | <300 cSt |
| Data Storage | 10-year cumulative data retention (64 months × 64 days) |
| Language Options | Simplified Chinese, Traditional Chinese, English |
| Unit Selection | m³/h, L/min, mL/min, gal/min (GPM), L/h |
| Battery Backup | CR1220 for real-time clock |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-ZO-S |
| Installation Type | Panel-mount (DIN rail or cutout mounting) |
| Display | LED numeric display (standard) |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Power Consumption | ≤150 W |
| Oxygen Range | 0–25% O₂ (programmable, adjustable between 5–25% O₂) |
| Output Signal | 4–20 mA (load ≤500 Ω) |
| Temperature Control Accuracy | ±1°C |
| Measurement Accuracy | ±1% of reading (O₂) |
| Response Time | ≤5 s to 90% of final value upon standard gas introduction |
| Operating Ambient Temperature | −20°C to +70°C |
| Enclosure Dimensions (Analyzer Unit) | 160×80×160 mm (horizontal), 80×160×160 mm (vertical), 144×144×160 mm / 160×160×160 mm (square variants) |
| Housing Material | Aluminum die-cast enclosure (IP65-rated) |
| Probe Material | 304 stainless steel (316L optional) |
| Probe Insertion Lengths | 500, 800, 1000, 1200 mm (custom lengths available) |
| Flue Gas Temperature Limit | ≤700°C |
| Flue Gas Pressure Range | −10 kPa to +10 kPa |
| Flue Gas Velocity | 0–50 m/s |
| Weight | ~2 kg |
| Brand | TimePower |
|---|---|
| Model | TP150 |
| Origin | Beijing, China |
| Manufacturer | TimePower Co., Ltd. |
| Measurement Range | 0.00–20.00 mg/L |
| Resolution | 0.01 mg/L (in mg/L range) / 0.1 µg/L (in µg/L range) |
| Repeatability | ≤1% FS |
| Stability | ±1.5% FS |
| Temperature Compensation Range | 0.1–80.0 °C |
| Water Sample Temperature Range | 5–80 °C |
| Ambient Temperature Range | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Relay Outputs | 2 SPST, AC220V/3A or DC30V/3A |
| Communication Interface | RS485 |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | <5 W |
| Enclosure Rating | IP65 |
| Dimensions | 142 × 125 × 155 mm (H×W×D) |
| Panel Cutout | 138 × 138 mm |
| Weight | 1.6 kg |
| Data Retention | >10 years after power loss |
| Response Time (T90) | <5 min at 25 °C |
| Sensor Type | Polarographic (Clark-type) with BJC membrane cap rated to 130 °C |
| Temperature Sensor | Pt1000 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-202 |
| Pricing | Upon Request |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TONSOER® Explorer I Platform |
| Pricing | Upon Request |
| Measurement Scope | Designed for spatially distributed, homogeneous process monitoring applications — e.g., Cu²⁺ and H₂SO₄ concentration monitoring in PCB manufacturing lines |
| Detection Principles | Potentiometric titration (acid-base, complexometric, precipitation, redox), photometric detection, and photometric titration |
| Sample Throughput | Base configuration (4 modules): ~10 min for 4 analytes |
| Standard configuration (8 modules) | ~10 min for 8 analytes |
| System Footprint | 3550 mm (W) × 650 mm (D) × 1850 mm (H) |
| Sample Handling Unit | 1250 mm (W) × 650 mm (D) × 1000 mm (H) |
| Analytical Unit | 620 mm (W) × 650 mm (D) × 1850 mm (H) |
| Power Supply | 198–242 V AC, 50 Hz ± 0.5 Hz, 2000 W |
| Operating Environment | 15–30 °C, RH 65 % ± 20 % (max daily temperature fluctuation ≤5 °C) |
| Control Interface | Windows-based desktop PC with ≥23-inch display |
| Brand | Truelab |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A-1H, A-2H |
| Inlet Pressure Rating | 15 MPa |
| Adjustable Outlet Pressure Range | 0.12–0.99 MPa |
| High-Pressure Gauge Range | 0–25 MPa |
| Low-Pressure Gauge Range | 0–0.16 / 0–0.6 / 0–1.0 / 0–1.6 MPa |
| Inlet Connection | G5/8 (Right), W21.8-14 (Right or Left) |
| Outlet Connection | 8 mm Flexible Tube Fitting with Threaded Port |
| Regulatory Compliance | Designed per GB/T 25127.2–2010 and ISO 8503-2 for industrial gas handling systems |
| Key | Brand: Truelab |
|---|---|
| Origin | Beijing, China |
| Model Series | A-1H / A-2H / Ba-1H / Ba-2H / Sa-1H / Sa-2H |
| Inlet Pressure Range | 0–15 MPa |
| Outlet Pressure Range | 0–0.12 / 0.4 / 0.6 / 0.99 MPa |
| High-Pressure Gauge Range | 0–25 MPa |
| Low-Pressure Gauge Range | 0–0.16 / 0.6 / 1 / 1.6 MPa |
| Inlet Connection | G5/8 (RH), W21.8-14 (RH or LH) |
| Outlet Connection | 8 mm soft tubing with threaded ferrule |
| Material | Brass body with stainless steel diaphragm and internal components (A-series) |
| Dead Volume | < 1.2 mL |
| Operating Temperature | –10 °C to +50 °C |
| Compliance | Designed per ISO 8503-2 (surface profile), compatible with ASTM E2653 (gas purity verification protocols), suitable for GLP/GMP environments requiring traceable gas delivery |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TruFluor pH |
| Price Range | USD 1,400 – 4,200 |
| Brand | TUNE VOLT |
|---|---|
| Origin | Beijing, China |
| Model | TW-6536(W) |
| Measurement Range | 0–20 mg/L |
| Resolution | 0.01 mg/L |
| Repeatability | ±1% FS |
| Stability | ±1% FS |
| Temperature Compensation Range | 5–50 °C |
| Communication Interface | RS485 (optional) |
| Dimensions | 155 mm × 155 mm × 140 mm (W × H × D) |
| Operating Ambient Temperature | 0–60 °C |
| IP Rating | IP65 |
| Output | Dual isolated 4–20 mA |
| Display | 192 × 64 dot-matrix LCD (bilingual Chinese/English) |
| Data Storage | 100,000 historical data points, 1,000 operation logs, 100 calibration records |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Amine Concentration and H₂S/CO₂ Acid Gas Online Analyzer |
| Pricing | Available Upon Request |
| Brand | TZ Environmental |
|---|---|
| Origin | Shandong, China |
| Model | TZ-BL1 |
| Wave Height Range | 0.01–25 m |
| Accuracy (Wave Height) | < ±3% |
| Wave Period Range | 1.6–30 s |
| Accuracy (Period) | ±0.25 s |
| Wave Direction Range | 0–360° |
| Accuracy (Direction) | ±5° |
| Measurement Parameters | Significant wave height (Hs), maximum wave height (Hmax), average wave height (Havg), H1/10, peak period (Tp), mean period (Tm), H1/10 period, dominant wave direction, wave number |
| Output Interface | RS-232, 9600 baud |
| Operating Voltage | 10–15 V DC |
| Onboard Storage | 32 GB microSD card (≥3 years of continuous data at 4 Hz sampling) |
| Dimensions | 265 × 185 × 133 mm |
| Weight | 3 kg |
| Sampling Frequency | 4 Hz |
| Sampling Duration per Cycle | 1024 seconds |
| Operational Modes | Standard (3-hour), Professional (½-hour, 1-hour, 3-hour), Flagship (½-hour, 1-hour, 3-hour, triggered & user-controlled) |
| Brand | Tianze Environmental |
|---|---|
| Origin | Shandong, China |
| Model | TZ-LS6+ |
| Measurement Principle | Acoustic Doppler Effect |
| Velocity Range | 0.020–6.00 m/s |
| Accuracy | ±1.0% of reading or ±1 mm/s (whichever is greater) |
| Resolution | 1 mm/s |
| Water Temperature Range | −10 to +60 °C |
| Temp. Accuracy | ±0.1 °C |
| Depth Range | 0.03–10 m |
| Depth Accuracy | ±0.3% FS or ±0.5 cm |
| Depth Resolution | 1 mm |
| Instantaneous Flow Range | 0.001–9999 m³/h |
| Flow Accuracy | ±3% of reading |
| Cumulative Flow Range | 0.001–9999 m³ |
| Flow Resolution | 0.001 m³ |
| Data Update Rate | 1 Hz |
| Power Supply | 10.0–12.6 V DC |
| Battery Capacity | 1800 mAh Li-ion |
| Operating Time | >8 h (on battery) |
| Cable Length | 20 m |
| Max. Submersion Depth | 10 m |
| Display | 2.8″ color LCD |
| Data Storage | 10,000 records |
| Interface | USB data export |
| Operating Language | English / Chinese toggle |
| Sensor Power Consumption | <0.8 W (during velocity measurement) |
| Total Unit Power Consumption | <2.4 W |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 1,700 (FOB) |
| Compliance | GB/T 4857.3–1992, GB/T 4857.4–1992 |
| Load Capacity | Up to 5,000 N (configurable) |
| Displacement Resolution | 0.01 mm |
| Test Speed Range | 1–500 mm/min (adjustable) |
| Data Storage | 20 test records |
| Output | Thermal printer interface, USB data export |
| Brand | FPI (Focus Photonics) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | UTS-2000 |
| Pricing | Upon Request |
| Brand | Vaisala |
|---|---|
| Origin | Finland |
| Manufacturer | Vaisala Oyj |
| Type | Optimus™ OPT100 DGA |
| Application | Online dissolved gas analysis (DGA) for sealed power transformers |
| Measurement Principle | Non-dispersive infrared (NDIR) spectroscopy with vacuum-assisted headspace gas extraction |
| Calibration | Automatic in-situ zero/span correction using internal reference gas cell |
| Materials in contact with oil | 316 stainless steel and anodized aluminum |
| Pumping system | Magnet-driven gear pump |
| Maintenance interval | Maintenance-free design (no consumables, no scheduled servicing) |
| Installation time | <2 hours |
| Data output interval | Configurable down to 1-hour intervals (no data averaging required) |
| User interface | Web-based HTML5 interface with TLS-secured remote access |
| Environmental rating | IP65 enclosure |
| Compliance | Designed for IEC 60599, IEEE C57.104, and compatible with ISO/IEC 17025-accredited DGA workflows |
| Brand | VC Plasma |
|---|---|
| Model | JBT460 |
| Track Length | 850 mm |
| PCB Size Range | 30–460 mm |
| Conveyor Height | 900 ± 20 mm |
| Transmission Direction | Left-to-Right or Right-to-Left |
| Power Supply | 220 V / 50 Hz |
| Control System | Single-Chip Microcomputer |
| Conveyor Type | Flat Belt |
| Communication Interface | Dual SMEMA (Standardized Machine Equipment Manufacturer’s Association) |
| Dimensions (L×W×H) | 850 × 820 × 1100 mm |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Dry Ice Capacity Options | 20 kg / 40 kg / 60 kg / 100 kg |
| Core Insulation Materials | Vacuum Insulation Panels (VIPs, 280–330 kg/m³) + Hollow Density Board (90 kg/m³) + Polyurethane (PU) Foam (55–60 kg/m³) |
| Thermal Conductivity (λ) | <0.0025 W/m·K |
| Average Daily Dry Ice Sublimation Rate | ≤5% |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Application | Plasma Process Simulation & Industrial Plasma Source Driving |
| Key Features | Simple Operation, High Cost Performance, Low-Temperature Anti-Static Design, Compatible with Pointed and Rotating Transmitters |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Power Architecture | DPM-Based Digital Platform |
| Input Power Factor Correction (PFC) | Integrated |
| Output Topology | High-Efficiency Full-Bridge Inverter |
| Output Waveform | Quasi-Sinusoidal |
| Control Method | Vector-Controlled Constant-Power Delivery |
| Frequency Management | Digital Variable-Frequency & Dynamic Frequency-Hopping |
| Human-Machine Interface | Touchscreen with Real-Time Parameter Visualization |
| Operating Temperature Range | 50–70 °C (customizable) |
| Output Potential | <23 V (customizable) |
| Energy Intensity Monitoring | Integrated Spectroscopic Detection |
| Emitter Compatibility | Direct-Injection & Rotary Plasma Emitters |
| Fault Diagnostics | 21-Channel Real-Time Fault Logging & Alarm System |
| Monitoring Capabilities | Dual-Loop Real-Time Supervision of Power Supply (voltage, current, power, air pressure, operating frequency, spray gun RPM, module temperature, fan status, communication integrity) and Motor Subsystem (voltage, current, power, torque, operational mode, health index, communication return rate, speed profile) |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | NA |
| Pricing | Available Upon Request |
| Brand | Vcam |
|---|---|
| Model | GA2000 CH1-14 |
| Origin | Guangdong, China |
| Channel Capacity | 2–14 configurable analog input channels |
| Measurement Range | 1 ppm – 25% O₂ (full-scale selectable per channel) |
| Accuracy | ±3% of reading for 25%–1% O₂ |
| Response Time (T90) | <60 s |
| Output Interface | 4–20 mA / RS485 Modbus RTU / Ethernet (optional) |
| Compliance | Designed to support GLP/GMP-aligned process validation and FDA 21 CFR Part 11 audit-trail readiness via optional software module |
| Brand | Vcam |
|---|---|
| Model | GA2000-1 |
| Origin | Guangdong, China |
| Measurement Range | 25%–1% ±3% |
| Response Time | T90 < 60 s |