Industry-specific Instruments
Filter
Showing 1–30 of 2098 results
| Brand | 3M |
|---|---|
| Model | 6800 |
| Origin | Jiangsu, China (Manufactured under 3M global licensing & quality oversight) |
| Manufacturer Type | OEM/ODM Production Partner |
| Compliance | Meets GB 2890–2023 (China), EN 136:2023 Class 2, and compatible with NIOSH-approved 3M™ filter cartridges (e.g., 6001CN–6006CN series) |
| Weight | Approx. 510 g (without filters) |
| Facepiece Material | Medical-grade silicone |
| Field of View | ≥210° horizontal, ≥105° vertical |
| Exhalation Valve | Cold-flow, downward-oriented dual-valve design |
| Head Harness | Four-point adjustable textile strap system |
| Filter Interface | Standard 40 mm × 1/7″ threaded connection (DIN 3776) |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuPoint |
| Price | Upon Request |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | AQT200 |
| Package Quantity | 100 swabs per box |
| Storage Conditions | 2–8 °C (refrigerated) for up to 12 months |
| Intended Use | Total ATP quantification in rinse water and surface rinse samples from food processing equipment and CIP systems |
| Compatible Instrument | 3M Clean-Trace NG Luminometer |
| Output Unit | Relative Light Units (RLU) |
| Regulatory Context | Designed for use in environments compliant with HACCP, GMP, and FDA 21 CFR Part 11–aligned data integrity workflows |
| Application Scope | Food & beverage manufacturing, dairy, meat & poultry, seafood, produce, beverages, bottled water, pet food, nutraceuticals, and bakery |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | AQT200 |
| Package Quantity | 100 swabs per box |
| Storage Conditions | 2–8 °C (refrigerated) for up to 12 months |
| Intended Use | Total ATP quantification in rinse water and surface rinse samples from food processing equipment and CIP systems |
| Compatible Instrument | 3M Clean-Trace NG Luminometer |
| Output Unit | Relative Light Units (RLU) |
| Compliance Context | Designed for use in HACCP, GMP, and FSMA-aligned environmental monitoring programs |
| Application Scope | Food & beverage manufacturing, dairy, meat & poultry, seafood, produce, beverages, confectionery, pet food, and ingredient processing facilities |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | Clean-Trace ATP LM1 |
| Detection Principle | ATP-dependent bioluminescence assay |
| Sample Types | Surface swabs (UXL100), total aqueous ATP (AQT200), free aqueous ATP (AQF100) |
| Compliance | Designed for use in food safety hygiene monitoring per ISO 22000, HACCP, and FDA Food Code guidance |
| Software | 3M Clean-Trace Hygiene Management Software with wireless data sync, audit-trail-capable reporting, and 21 CFR Part 11–ready configuration options |
| Portability | Handheld, battery-operated, integrated cradle charging station |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | Clean-Trace ATP LM1 |
| Detection Principle | ATP-dependent bioluminescence assay |
| Sample Types | Surface swabs (UXL100), water samples (AQT200, AQF100) |
| Data Connectivity | Wireless (Bluetooth/Wi-Fi enabled) |
| Software Platform | 3M Clean-Trace Hygiene Management Software |
| Compliance Support | Designed for use in environments requiring adherence to HACCP, ISO 22000, FDA Food Code, and GMP-aligned hygiene verification protocols |
| Power | Rechargeable battery with AC adapter |
| Portability | Handheld, ergonomic design for single-hand operation |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | LM1 |
| Detection Principle | ATP-dependent luciferase bioluminescence assay |
| Sample Types | Surface swabs (UXL100), free ATP in water (AQF100), total ATP in water (AQT200) |
| Software | Clean-Trace Hygiene Management Software with wireless connectivity, automated reporting, and audit-ready data logging |
| Compliance Context | Designed for use in environments requiring adherence to HACCP, ISO 22000, FDA Food Safety Modernization Act (FSMA), and GMP-aligned hygiene verification protocols |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Clean-Trace™ |
| Pricing | Upon Request |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 3M™ Clean-Trace™ NGI |
| Pricing | Available Upon Request |
| Weight | 400 g |
| Detection Range | 0–999,999 RLU |
| Sensitivity | 10⁻¹⁵ mol ATP |
| Read Time | 10 s |
| Repeatability (CV%) | 7.4% |
| Data Storage | 10,000 test results |
| Sampling Plans | 100 plans (up to 300 points each) |
| Plan Points | 2,000 total |
| Display | 240 × 160-pixel backlit LCD |
| Battery | Rechargeable Li-ion, 36 h continuous operation |
| Auto-Diagnostics | Power-on self-test & real-time fault alerting |
| Sample Chamber | Auto-sensing lid with timeout alarm |
| Software | Trend analysis with 9 filtering modes, 5 report templates, 10 chart types, Excel export |
| User Management | Customizable role-based permissions |
| ATP Reagent Format | Pre-loaded liquid luciferin/luciferase in swab |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Instrument |
| Model | AD-3253 / AD-3253B |
| Thickness Range | 0.8–100 mm (AD-3253: 2–200 mm) |
| Accuracy | ±0.1 mm |
| Weight | 180 g |
| Power | Single AA alkaline battery |
| Battery Life | >30 h continuous operation (at 25°C, 5 mm steel sample) |
| Auto Power-Off | After 5 min idle |
| Display | Backlit LCD |
| Units | mm / inch selectable |
| Sound Velocity Input | Adjustable via keypad, stored non-volatile memory |
| Calibration | Single-point material calibration for velocity determination |
| Standard Accessories | Protective leather case, 5 mm calibration block, instruction manual, probe holder (AD-3252 only), dual probe (optional) |
| Brand | A&D |
|---|---|
| Model | AD-8127 |
| Printing Method | Impact Dot-Matrix |
| Character Format | 7×9 dots |
| Character Size | 1.6 mm (W) × 3.2 mm (H) |
| Print Speed | ~1.6 lines/sec |
| Paper Feed Speed | ~4 lines/sec |
| Characters per Line | 24 |
| Operating Temp. | 0–40 °C, 35–85% RH (non-condensing) |
| Storage Temp. | −20–60 °C, 10–90% RH (non-condensing) |
| Interface | RS-232C / Current Loop |
| Power Supply | AC Adapter AX-TB135 or AX-TB285 (Input: AC 100 V ±10% / −15%, 50/60 Hz) |
| Power Consumption | ~36 VA (incl. adapter) |
| Dimensions (W×D×H) | 174 × 141 × 87 mm |
| Weight | ~500 g |
| Standard Accessories | Ribbon cartridge, plain paper roll, AC adapter, identification label, user manual, RS-232C cable (D-Sub9P/D-Sub25P configurable) |
| Brand | AANDD |
|---|---|
| Model | LC4101-G600 |
| Rated Capacity | 6 N (611.8 g) |
| Deflection | 0.24 mm |
| Natural Frequency | 100 Hz |
| Allowable Moment | 0.212 N·m |
| Rated Output | 1.0197 mV/V (+15% / –0%) |
| Zero Balance | ±20% of RO |
| Input Resistance | ~400 Ω |
| Output Resistance | 350 ±5 Ω |
| Insulation Resistance | >500 MΩ @ DC 50 V |
| Temp. Compensation Range | –10 °C to +40 °C |
| Zero Temp. Effect | ±0.04 %RO / 10 °C |
| Output Temp. Effect | ±0.014 %FS / 10 °C (typ.) |
| Recommended Excitation | DC 5–12 V |
| Max. Excitation | DC 15 V |
| Overload Limit (Safe) | 300 %RC |
| Ultimate Overload | 400 %RC |
| Total Error | ±0.015 %RO |
| IP Rating | IP22 |
| Cable | Ø4 mm × 1.5 m (Red: +Exc, White: –Exc, Green: +Sig, Blue: –Sig, Yellow: Shield) |
| Housing Material | Aluminum |
| Dimensions | 300 × 300 mm |
| Mass | 0.12 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RVP4500 Series |
| Pricing | Available Upon Request |
| Brand | ABET Technologies |
|---|---|
| Origin | USA |
| Model | SUN3000 |
| Illumination Mode | Steady-State |
| Spectral Classification | IEC 60904-9, ASTM E927-19 & JIS C 8912 Class AAA |
| Irradiance Uniformity | ≤2% (over 110 × 110 mm) |
| Spectral Match (AM1.5G) | 0.75–1.25 |
| Short-Term Stability | ≤0.5% (1 h) |
| Long-Term Stability | ≤2% (8 h) |
| Output Aperture | 110 × 110 mm |
| Working Distance | 200 mm |
| Light Source | Ozone-Free Xenon Arc Lamp (550 W) |
| Lamp Lifetime | 1500 h |
| Cooling System | HEPA-Filtered Forced-Air |
| Photofeedback Control | Integrated |
| Shutter | Electronically Controlled with Digital Timer |
| Input Power | 110/240 VAC, 50/60 Hz, ≤10 A |
| Optional IV Measurement System | ReRa Tracer IV Software + Temperature-Controlled Vacuum Chuck Platform (4-wire, 0–10 A range, sample size 10 × 10 mm to 156 × 156 mm) |
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ABN-3AX |
| Spindle Power | 0.75 kW |
| Max Spindle Speed | 12,000 rpm |
| X/Y Axis Travel | 50 mm |
| Z Axis Travel | 150 mm |
| Worktable Size | 120 × 120 mm |
| Rotational Capability | 360° continuous indexing (manual or optional motorized) |
| Cooling System | Integrated mist coolant delivery |
| Drive System | Precision servo motors with closed-loop feedback |
| Brand | Aboni |
|---|---|
| Origin | Germany |
| Model | HT3 |
| Measurement Principle | Calcium Hydride Reaction (Hydrogen Gas Evolution) |
| Sample Capacity | 0.01–50 g (up to 100 g depending on density & moisture content) |
| Sample Volume | ~50 mL |
| Detection Range | 0.2–30 mg H₂O |
| Resolution | ±0.1 mg H₂O (at 1 mg) to ±0.3 mg H₂O (at 20 mg) |
| Heating Temperature Range | 50–210 °C (1 °C increments) |
| Reagent | Calcium Hydride (CaH₂) powder, ~0.1 g per test |
| Environmental Monitoring | Temperature (±0.1 °C), Relative Humidity (0–100 % RH, ±0.1 %), Atmospheric Pressure (700–1100 mbar, ±0.1 mbar) |
| Power Supply | 230 VAC, 1.6 A |
| Dimensions | 285 (H) × 170 (W) × 250 (D) mm |
| Weight | 4.6 kg |
| Interface | RS232 or USB |
| Compliance | ISO 15512 |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Acona A2000 SIS |
| Price Range | USD 1,400 – 63,000 |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | Acona A2000SIS CP/USP |
| Price Range | USD 1,400 – 63,000 |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Acona A2000SIS |
| Price Range | USD 1,400 – 63,000 |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction & Light Scattering |
| Dynamic Range | 0.5–400 µm |
| Minimum Sample Volume | 50 µL |
| Resolution | 0.01 µm (1024-channel binning) |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | USP <787>, USP <729>, FDA 21 CFR Part 11, cGMP/GLP |
| Software Features | Audit Trail, Role-Based Access Control, Electronic Signatures, LIMS Integration, Automated Pass/Fail Reporting |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Acona2000SIS |
| Price Range | USD 1,400 – 63,000 |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | CB10 |
| Compliance | ASTM D665, ASTM D7548, NACE TM0172, IP 135, ISO 7120, JIS K2510 |
| Test Positions | 2 independent stations |
| Automation Level | Fully automated water injection, temperature ramping, stirring, specimen immersion & retrieval |
| Interface | Touchscreen with embedded calibration datasets |
| Safety | Direct-drive low-torque motor with immediate stall detection and emergency stop |
| Integration | Compatible with CT10 Corrosion Rating Station for end-to-end automated evaluation |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | SP10 |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 1 kPa (typical ambient reference) |
| Temperature Control Resolution | 0.1 °C |
| Test Duration | <10 min |
| Flame Height Resolution | 0.1 mm |
| Connectivity | Ethernet (RJ45), USB (2 ports), Optional Printer via USB |
| Dimensions (W×D×H) | 330 × 390 × 413 mm |
| Weight | 10 kg |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | SP20 |
| Compliance | ASTM D1322, GB/T 3822 |
| Measurement Principle | Optical flame morphology detection with real-time height quantification |
| Test Duration | < 10 min per sample |
| Height Resolution | 0.1 mm |
| Data Storage Capacity | Up to 1,000,000 results |
| Connectivity | Ethernet, RS-232, USB |
| Display | 8-inch full-color touchscreen |
| Dimensions (L×W×H) | 330 × 390 × 413 mm |
| Integrated Sensors | Barometric pressure, ambient temperature, relative humidity |
| Fuel Calibration | Pre-loaded standard fuel database with auto-compensated smoke point correction |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | TO10 |
| Test Standards | ASTM D3241, GB/T 9169, IP 323, ISO 6249 |
| Temperature Range | 100–380 °C |
| Pressure Drop Range | 0–750 mmHg (auto-bypass +700 mmHg) |
| Test Duration | 4–600 min |
| Air Flow Rate | 1.5 L/min (programmable) |
| Fuel Flow Control | Dual 5 mL syringe pumps (±1% accuracy) |
| Temperature Sensing | Class 1 K-type thermocouples |
| Cooling Method | Peltier + heat pipe (liquid-free) |
| Dimensions | 440 × 600 × 670 mm |
| Weight | 60 kg |
| Power Supply | 100–240 V, 8 A, 50/60 Hz |
| Operating Ambient | +10 to +35 °C |
| Connectivity | Ethernet (RJ45), USB ×2, optional USB printer |
| Data Storage | Integrated DR10 ITR interface with automated result transfer via Ethernet |
| Brand | AD SYSTEMS |
|---|---|
| Origin | France |
| Model | DR10 |
| Measurement Principle | Optical Interferometry |
| Thickness Range | 0–1200 nm |
| Volume Range | 0–0.5 mm³ |
| Measurement Points per Tube | 1200 |
| Scan Time | ≤15 min |
| Data Storage Capacity | Up to 100,000 records (internal database) |
| Interface | Ethernet (RJ45), USB 2.0 (for printer/data export), LAN/LIMS compatible |
| Dimensions (W×D×H) | 250 × 160 × 290 mm |
| Weight | 10 kg |
| Power Supply | 115–230 V AC, 2 A, 50/60 Hz |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | DT100 |
| Operating Principle | Digital Spot Test Image Analysis |
| Measurement Parameters | IC (0.1–5%), MD (0–100), DP (0–200) |
| Spot Acquisition Time | ~3 min per spot |
| Max Spots per Filter Paper | 16 |
| Imaging System | CCD digital camera with LED backlighting |
| Calibration | On-site using included calibration kit |
| Data Storage | USB drive, LAN network, or local printer (optional) |
| Interface | USB 2.0, RJ45 Ethernet |
| Dimensions | 305 × 487 × 390 mm |
| Weight | 20 kg |
| Power Supply | 230 V, 2 A, 50/60 Hz |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | VD10 |
| Operating Pressure | Atmospheric |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–65 °C |
| Distillation Rate | 2–10 mL/min |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Brand | ADEV |
|---|---|
| Origin | Beijing, China |
| Model | 7600 |
| Measurement Gases | O₂ (0–5% vol), CO (0–85% vol), H₂ (0–15% vol) |
| Accuracy | ≤±1% FS for O₂ |
| Response Time | ≤15 s |
| Dust Tolerance | ≤600 g/Nm³ |
| Operating Temp. | 20–500 °C |
| Pressure Range | −10 to +10 kPa |
| Filtration Precision | 0.1 µm |
| Auto-Cleaning | Yes (pneumatic probe & filter blowback) |
| Output Signals | 4–20 mA analog + relay alarm (1 A, dry contact) |
| Compliance | Designed for GLP-aligned industrial process safety monitoring in metallurgical environments |
| Brand | ADEV |
|---|---|
| Model | 7600R |
| Origin | Beijing, China |
| Instrument Type | Continuous In-situ Gas Analysis System |
| Measurement Principle | Paramagnetic O₂ + Thermal Conductivity (H₂, CH₄, CO) + NDIR (CO₂) |
| Gas Matrix | Coke oven gas, blast furnace gas, converter gas, non-ferrous metallurgical gas |
| Sample Temperature Range | 20–800 °C |
| Dust Load Tolerance | ≤600 g/Nm³ |
| Pressure Range | −10 to +10 kPa |
| Response Time (T₉₀) | <15 s |
| Accuracy | ≤±1% FS |
| Dust Filtration Precision | ≤0.1 µm |
| Output Signals | 4–20 mA (isolated), relay alarms (220 VAC, 1 A), digital display |
| Cabinet Configuration | Integrated “turnkey” analyzer cabinet with pre-assembled sampling preprocessing, control, and analysis modules |
| Power Supply | 220 V AC ±10%, 50 Hz ±10% |
| Utility Requirement | Oil-free, dry nitrogen (0.4–0.6 MPa) |
| Maintenance Interval | >180 days (field-dependent) |
| Compliance | Designed for GLP/GMP-aligned operation |
