| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 Volume & Surface Resistivity Tester |
| Test Voltage Range | 10 V – 1000 V DC (7 precision-adjustable steps, ±1% accuracy) |
| Volume Resistivity Range | 1×10⁴ Ω·cm to 1×10¹⁸ Ω·cm (15 auto-ranging decades, ±5% accuracy at 23°C ±2°C, 50% RH ±5%, 100 V) |
| Surface Resistivity Range | 1×10³ Ω to 1×10¹⁷ Ω (14 auto-ranging decades, ±6% accuracy under same conditions) |
| Minimum Detectable Current | 1×10⁻¹⁴ A |
| Input Impedance | >1×10¹⁴ Ω |
| Electrode System | Tri-electrode configuration (guard, measuring, high-voltage electrodes) |
| Compliance | GB/T 1410–2006, GB/T 31338–2015, ASTM D257–14, IEC 60093:2016, JJG 690–2015 (Class II) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-530 |
| Volume Resistivity Range | 1.0×10⁴ to 1.0×10¹⁸ Ω·cm |
| Surface Resistivity Range | 1.0×10⁴ to 1.0×10¹⁷ Ω |
| Resolution (Volume) | 1.0×10³ Ω·cm |
| Resolution (Surface) | 1.0×10³ Ω |
| Accuracy | ±10% at 100 V |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Sample Thickness (Volume) | 0.01–30 mm |
| Sample Dimension (Surface) | ≥50 mm diameter or side length |
| Compliance | GB/T 1410-2006, ASTM D257-14 |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | MAP-PAK Combi |
| Measurement Range | 0.1–100% O₂ and CO₂ |
| Accuracy | ±1% of reading |
| Response Time | <10 s |
| Data Storage Capacity | Up to 5,000 records |
| Display | Backlit LCD |
| Power | Rechargeable battery (4 units) + AC adapter |
| Compliance | CE-marked, ISO 9001-manufactured instrumentation |
| Software | MP Download Software (Windows-compatible) |
| Optional Accessory | Portable thermal printer |
| Language Support | Multilingual UI (English, French, German, Spanish, Italian, Chinese) |
| Brand | AYALYTICAL |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AgDDI |
| Price | Contact for Quote |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XCS66800/0048 |
| Price Range | USD 999–9,999 |
| Brand | Diagnoptics |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AGE Reader mu |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AcceleSep Petroleum Fraction Rapid Separation System |
| Pricing | Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | EOPC® Automated Polar Compound Separation System |
| Detection Principle | Normal-phase liquid chromatography with UV detection (200 nm) |
| Column Format | Standardized disposable EOPC separation cartridges (pre-packed silica-based) |
| Automation Level | Fully automated sample injection, gradient elution, fraction collection, and real-time UV monitoring |
| Throughput | Up to 6 samples unattended |
| Compliance | Designed to meet requirements of GB 5009.202–2016 “Determination of Polar Compounds in Edible Oils” |
| Solvent Management | Dual 4 L solvent reservoirs with dry-ice–assisted cooling (4 °C to ambient) |
| Flow Control | Valveless precision metering pump (±0.5% flow accuracy, 25 mL/min max) |
| Fraction Collection | Programmable S-type collector with coordinate customization, multi-channel waste/collect switching, compatibility with conical flasks, round-bottom flasks, and beakers |
| UV Detector | Fixed-wavelength 200 nm detector with real-time chromatogram display |
| Display | Integrated LED touchscreen showing pressure, flow rate, gradient profile, and run progress |
| Safety Design | Fully enclosed fluidic path |
| Software | Embedded method library including GB 5009.202–2016-compliant SOPs |
| audit-trail–capable operation log (GLP-supporting metadata | user ID, timestamp, method version, instrument parameters) |
| Origin | Yunnan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AGI-T3 |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Offline Disintegration Tester |
| Sample Capacity | 3-Basket Configuration |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed | 30 ±1 RPM |
| Water Bath Volume | 8 L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Offline Dissolution Tester |
| Model | 280-DS |
| Compliance | Supports eMQ and PVT per USP <711>, <724>, ASTM D6519, and FDA Guidance on Dissolution Equipment Verification |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Offline Dissolution Tester |
| Vessel Capacity | 13 positions |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Agitation Rate | 1–35 DPM (Dips Per Minute) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Dissolution Tester |
| Vessel Capacity | 8-position |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 10–250 rpm |
| Bath Volume | 18 L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Sampling System |
| Model | 850-DS |
| Compliance | Compatible with USP <711>, <724>, and ASTM D8239-22 |
| Pump Architecture | Integrated Rotary Piston Pump |
| Filtration | Optional 8-channel Whatman/Cytiva filter plate module |
| Sample Interface | Direct-to-HPLC vial tray (Agilent 1260/1290-compatible format) |
| Method Support | USP Apparatus 1 (Basket), 2 (Paddle), 3 (Reciprocating Cylinder), 5 (Paddle-over-Disk), 6 (Rotating Cylinder), and 7 (Reciprocating Holder) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Dissolution Tester |
| Vessel Configuration | 7-position or 12-position reciprocating rack |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Stroke Rate | 5–40 cycles/min |
| Stroke Distance | 20 mm |
| Water Bath Volume | 25 L |
| Vessel Capacities Supported | 50 mL, 100 mL, 300 mL |
| Maximum Media Exchange Cycles | 6 per test |
| Unattended Operation Duration | Up to 144 hours (6 days) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Dissolution Tester |
| Vessel Capacity | 7-position |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Stroke Rate | 5–60 DPM (Double Strokes per Minute) |
| Bath Volume | 25 L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model Series | VK 7025, VK 7010, VK 705, BIO-DIS (3-Method & 7-Method), 705-DS |
| Instrument Type | Offline Dissolution Testing System |
| Regulatory Compliance | Fully compliant with USP <711>, EP 2.9.3, JP XVII, and ChP 0931 |
| Brand | SIGAS (Schütz Mess- und Regeltechnik) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AGSS |
| Pricing | Available Upon Request |
| Brand | AGUS |
|---|---|
| Origin | Japan |
| Model | SPS-2000 |
| Maximum Axial Pressure | 15–75 kN |
| Maximum Pulse Current | 1000–3000 A |
| Base Vacuum | ≤2 Pa (reached in ≤5 min from atmosphere) |
| Ultimate Vacuum (with optional high-vacuum pump) | ≤5×10⁻³ Pa |
| Chamber Accessibility | Enhanced ergonomic loading/unloading design |
| Architecture | Modular, field-upgradeable platform |
| Core Heating Mechanism | Unidirectional pulsed DC current through conductive die/mold assembly |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AH-30A |
| Price | USD 3,750 (FOB) |
| Measurement Time | ≤30 s/sample |
| Parameters | Fat, Protein, Non-Fat Solids, Density, Freezing Point, Water Adulteration, Lactose, Ash, pH, Conductivity, Temperature |
| Fat Range | 0.00–25.00% (±0.08%) |
| Protein Range | 2.00–7.50% (±0.10%) |
| Non-Fat Solids Range | 3.00–15.00% (±0.10%) |
| Density Range | 1.015–1.040 g/cm³ (±0.0003 g/cm³) |
| Freezing Point Range | −0.3 to −0.7 °C (±0.001 °C) |
| Water Adulteration Range | 1–70% (±1%) |
| Lactose Range | 0.00–7.00% (±0.10%) |
| Ash Range | 0.4–1.5% (±0.05%) |
| pH Range | 0–14 (±0.05) |
| Conductivity Range | 3–14 mS/cm (±0.05 mS/cm) |
| Temperature Range | 1–40 °C (±1 °C) |
| Operating Ambient | 0–50 °C |
| Sample Temperature | 10–35 °C |
| Relative Humidity | 30–80% RH |
| Power Supply | AC 220 V / DC 12 V |
| Dimensions | 400 × 300 × 300 mm |
| Display | Backlit English LCD |
| Output | Integrated thermal printer (English interface) |
| Cleaning | Fully automated dual-loop rinsing and aspiration system |
| Brand | SDL Atlas |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | M021A |
| Pricing | Available Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | aerotracer |
| Detection Principle | Matrix-based Multi-Channel Mixed Sensor Array |
| Sample Flow Rate | 50–100 mL/min |
| Detection Time | < 60 seconds |
| Detectable Substances | Aviation Engine Lubricants, Hydraulic Fluids (e.g., MIL-PRF-83282/87257), De-icing Fluids (Type I/II/IV), Corrosion Inhibitors, Adhesives, Jet Fuel (Jet A/A-1) |
| Display | Graphical LCD Interface |
| Dimensions | 395 × 112 × 210 mm |
| Weight | 4.2 kg (without battery) |
| Operating Temperature | 0–45 °C |
| Relative Humidity | 5–95 % RH (non-condensing) |
| Power Supply | 110–240 VAC, 30 W or Rechargeable Battery (4 h standby) |
| Communication | RS232 Serial Interface |
| Data Storage | Removable 1 GB miniSD Card |
| Software | WinMuster AT (Offline & Real-Time Data Analysis) |
| OS Compatibility | Windows XP, Vista, 7 |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | GDA-F |
| Detection Principle | Multi-Sensor Fusion (IMS, PID, MOS, EC) + Pattern Recognition Algorithm |
| Detection Time | 2–60 s |
| Detection Range | 1 ppb – 10 ppm (gas-dependent) |
| Sample Interface | Dedicated Container Probe with Integrated Auto-Sampling Pump |
| Operating Temperature | −30 °C to +50 °C |
| Relative Humidity Range | 5–95% RH (non-condensing) |
| Power Supply | Rechargeable Li-ion Battery (30 W, 4 h runtime) |
| Dimensions | 39.5 × 11.2 × 21 cm |
| Weight | 4.2 kg |
| Data Interfaces | RS-232, Ethernet, Wireless Transmission |
| Sensor Channels | 8-channel parallel acquisition (dual IMS, dual PID, dual MOS, dual EC) |
| Database | Preloaded Library of TICs & Fumigants (Expandable) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | GDA-FR |
| Detection Principles | Ion Mobility Spectrometry (IMS), Photoionization Detection (PID), Metal Oxide Semiconductor (MOS), Electrochemical (EC) |
| Sensor Architecture | 8-channel parallel detection array |
| Response Time | <10 seconds for qualitative/quantitative identification |
| Target Analytes | 40+ industrial toxic gases and chemical warfare agents (CWAs) |
| Compliance | Designed for field deployment under ISO 17025-aligned operational protocols, compatible with GLP/GMP documentation workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | IRS1200 |
| Pricing | Available Upon Request |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | IS-Series Sterile Isolation System |
| Air Cleanliness Class | ISO 5 (Class 100) |
| Filter Efficiency | ≥99.99% @ 0.3 µm |
| Average Air Velocity | 0.45 m/s |
| Power Supply | AC 220 V / 50 Hz |
| Configuration | Custom-engineered footprint (L × W × H, mm) |
| Pressure Control | Dual-mode (positive or negative differential pressure) |
| Transfer Mechanism | Interlocked dual-door pass-through |
| Sterilization Options | Integrated VHP (vaporized hydrogen peroxide) in-situ sterilization or offline autoclave-compatible modular assembly |
| Control System | Microprocessor-based PLC with audit-trail-capable data logging |
| Air Handling | Configurable open-loop or closed-loop recirculation mode |
| Brand | Aisida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CQ1000 |
| Cutting Length | 50–750 mm |
| Cutting Width | 200–1270 mm |
| Material Thickness | 0.04–0.3 mm |
| Cutting Accuracy | ±1.0 mm |
| Web Speed | ≤60 m/min |
| Slitting Frequency | ≤13 cuts/min (at 500 mm length) |
| Overall Dimensions | 2600 × 2300 × 1700 mm |
| Machine Weight | ~1500 kg |
| Power Consumption | ≤9 kW |
| Max Roll Diameter | ≤320 mm |
| Edge Quality | No whitening, delamination, wrinkling, charring, or visible dust |
| Brand | Aisida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | CQ2000 |
| Pricing | Available Upon Request |
| Brand | Aisida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XG |
| Pricing | Upon Request |
| Brand | Aist / ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DM1250 |
| Detection Principle | Energy-Dispersive X-Ray Fluorescence (EDXRF) |
| Measurement Target | SO₃ in solid/powder samples |
| Analysis Time | 30–60 s per sample |
| X-ray Tube | ≤10 kV, ≤0.5 mA, ≤5 W |
| Detector | Ultra-thin beryllium-window proportional counter |
| SO₃ Range | Adjustable via calibration |
| SO₃ Precision | σ ≤0.03 wt% (3σ) |
| Compliance | GB/T 176–2017, JC/T 1085–2008, JB/T 11145–2011 |
| Operating Temp | 5–40 °C |
| Humidity | ≤85% RH at 30 °C |
| Power | 220 V ±20 V, 50 Hz, ≤50 W |
| Dimensions | 470 × 365 × 130 mm (W×D×H) |
| Weight | 15 kg |