| Brand | AD System |
|---|---|
| Origin | France |
| Model | SP20 |
| Compliance | ASTM D1322, GB/T 3822 |
| Measurement Principle | Optical flame morphology detection with real-time height quantification |
| Test Duration | < 10 min per sample |
| Height Resolution | 0.1 mm |
| Data Storage Capacity | Up to 1,000,000 results |
| Connectivity | Ethernet, RS-232, USB |
| Display | 8-inch full-color touchscreen |
| Dimensions (L×W×H) | 330 × 390 × 413 mm |
| Integrated Sensors | Barometric pressure, ambient temperature, relative humidity |
| Fuel Calibration | Pre-loaded standard fuel database with auto-compensated smoke point correction |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | TO10 |
| Test Standards | ASTM D3241, GB/T 9169, IP 323, ISO 6249 |
| Temperature Range | 100–380 °C |
| Pressure Drop Range | 0–750 mmHg (auto-bypass +700 mmHg) |
| Test Duration | 4–600 min |
| Air Flow Rate | 1.5 L/min (programmable) |
| Fuel Flow Control | Dual 5 mL syringe pumps (±1% accuracy) |
| Temperature Sensing | Class 1 K-type thermocouples |
| Cooling Method | Peltier + heat pipe (liquid-free) |
| Dimensions | 440 × 600 × 670 mm |
| Weight | 60 kg |
| Power Supply | 100–240 V, 8 A, 50/60 Hz |
| Operating Ambient | +10 to +35 °C |
| Connectivity | Ethernet (RJ45), USB ×2, optional USB printer |
| Data Storage | Integrated DR10 ITR interface with automated result transfer via Ethernet |
| Brand | AD SYSTEMS |
|---|---|
| Origin | France |
| Model | DR10 |
| Measurement Principle | Optical Interferometry |
| Thickness Range | 0–1200 nm |
| Volume Range | 0–0.5 mm³ |
| Measurement Points per Tube | 1200 |
| Scan Time | ≤15 min |
| Data Storage Capacity | Up to 100,000 records (internal database) |
| Interface | Ethernet (RJ45), USB 2.0 (for printer/data export), LAN/LIMS compatible |
| Dimensions (W×D×H) | 250 × 160 × 290 mm |
| Weight | 10 kg |
| Power Supply | 115–230 V AC, 2 A, 50/60 Hz |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | DT100 |
| Operating Principle | Digital Spot Test Image Analysis |
| Measurement Parameters | IC (0.1–5%), MD (0–100), DP (0–200) |
| Spot Acquisition Time | ~3 min per spot |
| Max Spots per Filter Paper | 16 |
| Imaging System | CCD digital camera with LED backlighting |
| Calibration | On-site using included calibration kit |
| Data Storage | USB drive, LAN network, or local printer (optional) |
| Interface | USB 2.0, RJ45 Ethernet |
| Dimensions | 305 × 487 × 390 mm |
| Weight | 20 kg |
| Power Supply | 230 V, 2 A, 50/60 Hz |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | VD10 |
| Operating Pressure | Atmospheric |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–65 °C |
| Distillation Rate | 2–10 mL/min |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Key | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DD110 |
| Pricing | Available Upon Request |
| Neutron Yield | 1 × 10⁹ n/s |
| Neutron Energy | 2.5 MeV |
| Source Diameter | ≤ 16 mm |
| Maintenance Interval | ≥ 2000 h (scheduled, component-replaceable) |
| Operating Mode | Continuous (standard), Pulsed (optional, ≥ 50 µs pulse width, up to 100% duty factor) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DD110M / DD110 |
| Pricing | Available Upon Technical Inquiry |
| Brand | ADEV |
|---|---|
| Origin | Beijing, China |
| Model | 7600 |
| Measurement Gases | O₂ (0–5% vol), CO (0–85% vol), H₂ (0–15% vol) |
| Accuracy | ≤±1% FS for O₂ |
| Response Time | ≤15 s |
| Dust Tolerance | ≤600 g/Nm³ |
| Operating Temp. | 20–500 °C |
| Pressure Range | −10 to +10 kPa |
| Filtration Precision | 0.1 µm |
| Auto-Cleaning | Yes (pneumatic probe & filter blowback) |
| Output Signals | 4–20 mA analog + relay alarm (1 A, dry contact) |
| Compliance | Designed for GLP-aligned industrial process safety monitoring in metallurgical environments |
| Brand | ADEV |
|---|---|
| Model | 7600R |
| Origin | Beijing, China |
| Instrument Type | Continuous In-situ Gas Analysis System |
| Measurement Principle | Paramagnetic O₂ + Thermal Conductivity (H₂, CH₄, CO) + NDIR (CO₂) |
| Gas Matrix | Coke oven gas, blast furnace gas, converter gas, non-ferrous metallurgical gas |
| Sample Temperature Range | 20–800 °C |
| Dust Load Tolerance | ≤600 g/Nm³ |
| Pressure Range | −10 to +10 kPa |
| Response Time (T₉₀) | <15 s |
| Accuracy | ≤±1% FS |
| Dust Filtration Precision | ≤0.1 µm |
| Output Signals | 4–20 mA (isolated), relay alarms (220 VAC, 1 A), digital display |
| Cabinet Configuration | Integrated “turnkey” analyzer cabinet with pre-assembled sampling preprocessing, control, and analysis modules |
| Power Supply | 220 V AC ±10%, 50 Hz ±10% |
| Utility Requirement | Oil-free, dry nitrogen (0.4–0.6 MPa) |
| Maintenance Interval | >180 days (field-dependent) |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | GY-2000 |
| Measurement Range | CH₄: 0–100% vol, CO₂: 0–50% vol, H₂S: 0–9999 ppm, O₂: 0–20% vol, pH: 0–14, Temperature: 0–100°C, Pressure: 0–100 kPa |
| Resolution | 0.01% (for gas vol%), ppm-level detection for H₂S |
| Response Time | ≤30 s |
| Detection Principles | Non-dispersive Infrared (NDIR) for CH₄/CO₂, Electrochemical for H₂S/O₂, Potentiometric for pH, RTD/Thermistor for T, Piezoresistive for P |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Prometheus-2.1mm |
| Spot Size | 2.1 mm |
| Dynamic Range | Up to several million cd/m² (customizable) |
| Sampling Rate | Up to 3125 samples/sec (Y flicker mode) |
| CIE Standard Observer | 1931 2° |
| Compliance | USBTMC 1.0, IEEE 488.2 |
| Operating Systems | Windows, Linux (x86_64, i686, ARM), macOS |
| Software Integration | NI-VISA, LabVIEW, LabWindows CVI, Visual Studio |
| Detector Type | High-sensitivity, ultra-low-noise photodiode array |
| Features | Auto-ranging, mechanical shutter, integrated LED alignment pointer, JEITA-compliant flicker calculation engine |
| Filter Accuracy | Enhanced spectral match to CIE 1931 tristimulus curves vs. Hyperion series |
| Brand | ADOS |
|---|---|
| Origin | Germany |
| Model | Biogas 401 |
| Gas Measurement Principles | Electrochemical (O₂, H₂S), Non-Dispersive Infrared (NDIR) (CH₄, CO₂), Thermal Conductivity (H₂) |
| Measurement Ranges | O₂: 0–21 %vol |
| H₂S | 0–50 ppm / 0–5000 ppm (selectable) |
| CH₄ | 0–100 %vol |
| CO₂ | 0–50 %vol |
| H₂ | 0–2 %vol |
| Accuracy | < ±2 % FS |
| Response Time (T90) | ≤ 30 s (typ.) |
| Operating Temperature | +5 °C to +45 °C |
| Power Supply | 230 V AC, 50 Hz / 115 V AC, 60 Hz |
| Power Consumption | 100 VA |
| Dimensions (W×H×D) | 600 × 478 × 500 mm |
| Weight | ~61 kg |
| Output Interfaces | Dual 4–20 mA per channel (6 channels max), RS232/RS485 serial interface, 3 configurable alarm relays + 1 fault relay (230 V, 450 VA) |
| Sample Handling | Peltier-cooled condensate trap, peristaltic sampling pump, adjustable flow control, multi-stage particulate & moisture filtration |
| Brand | adphos |
|---|---|
| Origin | Germany |
| Model | PBT |
| Technology | Ultrafast NIR Thermal Processing |
| Wavelength Range | 800–1200 nm |
| Peak Power Density | Up to 100 MW/ft² (focused line geometry) |
| Substrate Compatibility | PET, PI, PVC, Paper, Foils, Flexible Polymers |
| Process Speed | Up to 300 m/min |
| Operating Mode | Continuous web or batch |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | OsmoTECH HT |
| Pricing | Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Advanced Instruments, Inc. |
| Product Category | Imported |
| Model | OsmoTECH PRO |
| Pricing | Available Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | OsmoTECH |
| Pricing | Available Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | OsmoTECH XT |
| Price | Upon Request |
| Brand | AEMC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Model 6292 |
| Pricing | Available Upon Request |
| Brand | CHINYEE / J.U.M. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AeroFid° 200 |
| Pricing | Available Upon Request |
| Key | Brand: AWT |
|---|---|
| Origin | United Kingdom |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Compliance Standard | EN 54-20 (Fire Detection and Alarm Systems – Smoke Detectors) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | CRTA-2 |
| Compliance | GB 9779–2015, GB 14907–2002, JG/T 157–2009 |
| Airflow Velocity | 3.0 ± 0.3 m/s |
| Test Specimen Dimensions | 150 × 70 × (4–6) mm |
| Timer Range | 0–99 h 99 min |
| Sample Substrate | Asbestos-free fiber-cement board (JC/T 412.1–2006, NAF HV grade, 4–6 mm thick) |
| Wet Film Thickness (Primer) | 80 µm |
| Drying Interval (Primer) | 1–2 h (tack-free) |
| Application Sequence | Primer → Immediate application of intermediate coat → Wind-induced drying test |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CTI-3 |
| Voltage Range | 100–600 V (25 V steps) |
| Electrode Material | Tungsten (99% purity) / Copper electrode holder |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Platinum Electrode Tip | 12 mm, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, 60° ± 5° included angle |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| Solution B | 1.98 ± 0.05 Ω·m |
| Drop Height | 35 ± 5 mm (adjustable) |
| Drop Interval | 30.00 ± 0.01 s (pre-settable) |
| Drops per cm³ | 44–55 |
| Total Drops Programmable | 1–9999 |
| Airflow Velocity | 0.2 m/s |
| Short-Circuit Current | 1.000 ± 0.001 A (voltage drop ≤ 8% at 1.0 A) |
| Tracking Threshold | 0.50 ± 0.05 A for ≥ 2.0 ± 0.2 s |
| Chamber Volume | > 0.5 m³ |
| Ambient Conditions | 0–40 °C, RH ≤ 80%, non-corrosive, vibration-free environment |
| Power Supply | 220 V AC, 0.6 kVA, 50–60 Hz |
| Dimensions (W×D×H) | 1160 × 600 × 1310 mm |
| Weight | Approx. 125 kg |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | GB/T 1692 Resistivity Tester |
| Compliance | GB/T 1692–2008, GB/T 1410, ASTM D257, IEC 60093 |
| Measurement Range | 1 × 10⁶ Ω to 1 × 10¹⁶ Ω |
| Test Voltages | 100 V, 250 V, 500 V, 1000 V (DC) |
| Electrode Configuration | Three-electrode system (main electrode Ø50 mm, guard ring ≥10 mm wide, grounded outer electrode) |
| Accuracy | ±20% of reading |
| Environmental Control Support | Compatible with standard climatic chambers (23 ± 2 °C / 50 ± 5 %RH) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | HDT-VST-300E |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Heating Medium | Methyl Silicone Oil (up to 300 °C) or Transformer Oil (up to 200 °C) |
| Standard Config | 3 Test Stations |
| Load Application | Mechanical Deadweight via Precision Calibration Weights |
| Temperature Sensing | PT100 Platinum Resistance Thermometer |
| Deformation Sensing | High-Resolution Digital Micrometer Sensor (0–10 mm range, 0.001 mm resolution) |
| Control System | 32-bit ARM Embedded Processor with Real-Time Isothermal Ramp Algorithm |
| Compliance | ISO 75-1:1993, ISO 306:1994, GB/T 1633–2000, GB/T 1634–2001 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | LDQ-5 |
| Voltage Range | 50–600 V AC/DC (±1% step accuracy) |
| Electrolyte | NH₄Cl solution (0.1–1.0 wt%), flow rate 0.5–2.0 mL/min (programmable) |
| Electrode Material | Pt-Rh alloy |
| Electrode Angle | 60° ± 5° |
| Electrode Force | 1.0 N ± 0.05 N |
| Trip Current Threshold | 0.5 A ± 10%, arc duration ≥ 2 s |
| Temperature Sensor Accuracy | ±1 °C |
| Humidity Range | 20–80 %RH |
| Data Acquisition | 16-bit resolution, current resolution 0.1 mA |
| Compliance | IEC 60112:2020, ASTM D3638-21, UL 746A, GB/T 4207-2022, VDE 0303-11, IEC 60695-2-2 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VFTA-2 |
| Price Range | USD 3,600 – 7,200 |
| Dimensions (W×D×H) | 1160 × 600 × 1250 mm |
| Combustion Chamber Volume | >0.5 m³ |
| Background | Matte Black, Illuminance ≤20 lux |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 150 W |
| Fuel Gas | Industrial propane, butane, or propane-butane mixture |
| Ignition Timer Range | 0–999.9 s |
| Burn Time Measurement Range | 0–999.9 s |
| Timing Resolution | 0.1 s |
| Flame Positioner Distances | 17 ±1 mm and 20 ±1 mm |
| Flame Height Calibration | 40 ±2 mm (vertical), 25 ±2 mm (horizontal) |
| Combustion Chamber Internal Dimensions | 900 × 600 × 1000 mm |
| Approx. Weight | 80 kg |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-121 |
| Measurement Principle | Four-Terminal (Kelvin) Method with Guarded Electrode System |
| Voltage Range | 10 V – 1000 V (selectable in discrete steps) |
| Resistance Range | 10³ Ω·cm to 10¹⁸ Ω·cm |
| Current Resolution | 0.1 fA |
| Compliance Standards | ASTM D257, IEC 60093, GB/T 1410 |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH (non-condensing) |
| Interface | RS485, USB |
| Safety Features | Overload protection, short-circuit protection, galvanic isolation, shielded enclosure (<5 µV residual noise) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | ZST-121 |
| Price Range | USD 2,100 – 7,000 |
| Resistance Range | 10 Ω to 2×10¹⁷ Ω |
| Resistance Accuracy | ±1% |
| Voltage Settings | 100 V, 250 V, 500 V, 1000 V |
| Voltage Accuracy | ±2% |
| Current Measurement Range | — |
| Display | 3½-digit LCD with backlight |
| Built-in Timer | 1–7 min auto-hold |
| Power Supply | 8×AA batteries (DC 8.5–12.5 V) or external regulated DC source |
| Dimensions (L×W×H) | 280 × 240 × 105 mm |
| Weight | 3 kg |
| Operating Environment | 0–40 °C, RH < 80% |
| Compliance | GB/T 1410–2006, GB/T 31838.1–2019, GB/T 2439–2001, GB/T 1692–2008, GB/T 10064–2006, GB/T 3048.5–2007 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZST-212 High-Resistance Meter |
| Price Range | USD 2,800 – 7,000 |
| Standards Compliance | IEC 60093, ASTM D257, GB/T 31838.2–2019, IEC 62631-3-1, GB/T 1410–2006, GB/T 1692–2008 |
| Display | 4.3-inch HD TFT |
| Voltage Range | ±10 V to ±1500 V DC (continuously adjustable) |
| Resistance Measurement Range | 10⁶ Ω to 10¹⁸ Ω (standard configuration) |
| Minimum Detectable Current | 10 fA |
| Input Impedance | >10¹⁶ Ω |
| Leakage Compensation | Dual-channel active current-voltage feedback network |
| Interface Options | USB 2.0, RS-232C, Handler (TTL/PLC-compatible) |
| Safety Features | ATEX-compliant explosion-proof variant available |
| Environmental Operating Range | −20 °C to +55 °C (industrial grade), relative humidity ≤75% RH (non-condensing) |
| Warm-up Time | ≥30 min required for metrological validity |
| Measurement Modes | Automatic & manual |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Measurement Range | 10⁶ Ω to 10¹⁸ Ω |
| Test Voltages | 10 V, 100 V, 250 V, 500 V, 1000 V DC |
| Input Impedance | >10¹⁴ Ω |
| Current Measurement Sensitivity | down to 1 fA |
| Compliance | IEC 60093, IEC 62631-3-1, ASTM D257, GB/T 1410 |
| Electrode Configuration | Tri-electrode system with guard ring |
| Environmental Operating Conditions | 23 ± 2 °C, 50 ± 5 % RH |
| Data Output | Digital LCD display with real-time current/resistance readout |
| Power Supply | AC mains with internal voltage regulation and EMI filtering |