| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-ZH |
| Function Type | Multi-analyte (Pesticide Residues, Veterinary Drug Residues, Heavy Metals, Microorganisms, Food Additives) |
| Sample Compatibility | Universal for Solid, Liquid, and Semi-solid Food Matrices |
| Detection Range | Pesticide residues (e.g., organophosphates, carbamates), veterinary drugs (e.g., chloramphenicol, sulfonamides), heavy metals (Pb, Cd, As, Hg via anodic stripping voltammetry), pathogenic microorganisms (via immunochromatographic lateral flow), food adulterants & illegal additives |
| LOD | 0.01 mg/kg for representative pesticide analytes |
| Optical System | LED cold light source |
| wavelength range | 380–800 nm |
| Detection Time | 3–10 min per assay |
| Detection Channels | 6 independent photometric channels (simultaneous multi-target quantification) |
| Repeatability | ≤ ±1% CV |
| Display | ≥7-inch capacitive touchscreen LCD |
| Detection Technologies | Integrated spectrophotometry, immunochromatography (lateral flow), thin-layer chromatography (TLC) imaging (254 nm UV excitation), fluorescence sensing, and anodic stripping voltammetry (ASV) |
| Connectivity | USB 2.0, Bluetooth 5.0, Wi-Fi 802.11 b/g/n, RJ45 Ethernet, microSD slot |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Storage | Internal flash memory (≥100,000 records) + cloud synchronization (HTTPS-secured API endpoint) |
| Dimensions | 300 × 200 × 150 mm (L×W×H) |
| Net Weight | 2.3–2.8 kg |
| Enclosure Rating | IP67 (dust-tight and submersible up to 1 m for 30 min) |
| Processor | Quad-core ARM Cortex-A53 or higher |
| Image Acquisition | CMOS-based direct optical signal capture (no post-processing interpolation) |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Model | ZYD-ZH/02 |
| Function Type | Multi-analyte (pesticide residues, veterinary drug residues, food additives, heavy metals, mycotoxins, pathogenic microorganisms) |
| Sample Compatibility | Liquid, solid, and semi-solid food matrices (e.g., vegetables, fruits, meat, dairy, aquatic products, grains) |
| Detection Methods | Spectrophotometry (visible/NIR), immunochromatographic assay (colloidal gold lateral flow), ATP bioluminescence |
| Detection Time | 3–15 min per assay (pesticide screening) |
| Detection Channels | ≥8 independent optical channels with simultaneous dual-wavelength measurement capability |
| Repeatability | ≤±3% CV |
| Display | 15-inch capacitive touchscreen LCD (1920×1080) |
| Operating System | Android 9.0 (customized industrial firmware) |
| Data Storage | Internal 32 GB eMMC + microSD/TF slot (up to 256 GB) |
| Connectivity | Gigabit Ethernet, Wi-Fi 5 (802.11ac), Bluetooth 5.0, 4G LTE (optional module) |
| Power Supply | AC 220 V ±10%, 50 Hz / DC 12.6 V (rechargeable Li-ion battery, ≥4 h continuous operation) |
| Dimensions (L×W×H) | 380 × 320 × 180 mm |
| Net Weight | 7.2 kg |
| Light Source | Stable cold LED array with wavelength-specific emission profiles (450–650 nm, configurable per assay) |
| Processor | Quad-core ARM Cortex-A72 @ 1.8 GHz + dedicated DSP co-processor for real-time spectral deconvolution and signal normalization |
| Regulatory Alignment | Designed to support compliance with GB/T 5009.x, GB 2763, GB 31650, NY/T 761, SN/T 1944, and ISO/IEC 17025 documentation requirements |
| Key | Brand: Zhonghang Dingli |
|---|---|
| Origin | Beijing, China |
| Model | ZHDL-200 Series |
| Motor Power | 3.0 kW (Panasonic) |
| Speed Range | 0.1–120 rpm |
| Torque Range | 0–200 N·m (rated 300 N·m) |
| Torque Accuracy | ±0.3% F.S. |
| Melt Pressure Range | 0.1–100 MPa |
| Pressure Accuracy | ±0.3% F.S. |
| Temp Control Range | Ambient to 350 °C (5-zone control, 6-point measurement) |
| Temp Accuracy | ±0.1 °C |
| Data Acquisition Rate | 50 Hz |
| Mixer Volume | 60 mL |
| Rotor Type | Roller (Banbury/Cam/Delta optional) |
| Heating Power | 2.1 kW (3×700 W) |
| Voltage | AC 380 V, 7.5 kW |
| Brand | Zhonghang Shidai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | ZLD-600V |
| Price Range | USD 2,100 – 5,600 |
| Brand | Zhonghangshidai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MFI-400H |
| Test Method | Volumetric (Method B per ISO 1133) |
| Type | Standard-Function Melt Flow Indexer |
| Temperature Range | Ambient to 300 °C (extended range: 80–400 °C) |
| Temperature Accuracy | ±0.1 °C |
| Melt Flow Rate Range | 0.1–100 g/10 min |
| Load Selection | Motorized, Programmable via Dual-Thread Lead Screw |
| Displacement Measurement | High-Precision Optical Encoder (ISO 1133 Method B) |
| Compliance | GB/T 3682–2018, ISO 1133:2005, ASTM D1238 |
| Brand | Zhonghangshidai |
|---|---|
| Model | ZST-121 |
| Standard Compliance | GB/T 31838.2–2019, GB/T 31838.3–2019 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (selectable) |
| Accuracy | ±2% |
| Display | Digital LCD |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | ~5 kg |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Brand | Zhonghuan Furnace |
|---|---|
| Origin | Tianjin, China |
| Model | ZHG-P30126 |
| Max Temperature | 1200 °C |
| Operating Temperature Range | ≤1100 °C |
| Rated Power | 20 kW |
| Supply Voltage | 380 V |
| Heating Zone | Single-zone |
| Temperature Control Accuracy | ±1 °C |
| Cold-Start Ramp Rate | ≤15 °C/min |
| Alloy Crucible Dimensions | Ø300 × 300 mm (D × H) |
| Ultimate Vacuum (Cold) | 10 Pa |
| Outer Shell Surface Temperature | ≤50 °C |
| Atmosphere Options | Ar, N₂ |
| Door Type | Side-opening |
| Heating Element | Silicon Carbide Rods |
| Thermocouple Type | Type S |
| Standard Configuration | Vacuum Pump, Debinding Canister, Gas Flow Meter |
| Optional Accessories | High-Temperature Off-Gas Cracking Unit, Chilled Water Circulator, High-Vacuum Diffusion Pump System |
| Brand | Zhongke Aobo |
|---|---|
| Model | TL0610 |
| Temperature Range | Up to 1000 °C |
| Furnace Volume | 6 L |
| Heating Rate | <30 min (100 °C to 1000 °C) |
| Power Supply | AC 220 V, 16 A |
| Control Accuracy | ±1 °C |
| Thermal Insulation | Ceramic Fiber |
| Heating Element | HRE Resistance Wire |
| Thermocouple Type | K |
| Net Weight | 50 kg |
| Compliance | ASTM D3174, ISO 3987, GB/T 212–2008 |
| Brand | Zhongke Instrument (ZKDZ) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSSD-01H |
| Pricing | Upon Request |
| Test Range | 0.00–600.00 kPa (standard), up to 1.60 MPa (optional) |
| Accuracy | Better than Class 0.5 |
| Pneumatic Interface | Φ6 mm polyurethane tubing |
| Air Supply Requirement | 0.4–0.9 MPa clean, dry air (user-supplied) |
| Flow Rate Control | 0.01–10 L/min |
| Pressure Holding Time | 0.1 s – 999999.9 s |
| Standard Nozzle Diameter | Φ6 mm (Φ4 mm and Φ1.6 mm optional) |
| Dimensions (L×W×H) | 420 × 320 × 150 mm |
| Test Chamber Footprint | 380 × 260 × 365 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 15 kg |
| Data Storage Capacity | 2000 test records |
| Compliance Standards | ISO 11607-1, ISO 11607-2, ASTM F1140, ASTM F2054, GB/T 10440, GB 18454, GB 19741, GB 17447, GB/T 17876, GB/T 10004, BB/T 0025, QB/T 1871, YBB00252005, YBB 00162002 |
| Brand | Zhonglu |
|---|---|
| Model | JLD-2000I |
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Price | USD 2,800 (FOB Shanghai) |
| Extraction Capacity | 2000 mL |
| Heating Power | 500 W |
| Max Heating Temperature | 300 °C |
| Analytical Balance Range | 0–100 g |
| Readability | 0.0001 g |
| Vacuum Drying Chamber Temp Range | RT+10 to 250 °C |
| Vacuum Level | ≤133 Pa |
| Compliance Standards | GB/T 29848-2013, IEC 62788-1-6, ASTM D2765, ISO 10147:2011, CQC 3307-2013 |
| Key | Brand: Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | MFI-1221 |
| Test Method | Mass Flow Rate (MFR) & Volume Flow Rate (MVR) |
| Temperature Range | 100–450 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Recovery Time | ≤2 min after charge |
| Die Dimensions | 2.095 mm ±0.005 mm ID, 8.000 mm ±0.025 mm length |
| Barrel ID | 9.550 mm ±0.007 mm |
| Piston Displacement Resolution | 0.002 mm |
| Piston Accuracy | ±0.02 mm |
| Load Application | Manual |
| Display | 5-inch HD color TFT touchscreen (bilingual: EN/CN) |
| Power Supply | 220 VAC ±10%, 50 Hz, 0.5 kVA |
| Weight | ~25 kg (main unit), ~25 kg (accessories) |
| Compliance | GB/T 3682–2018, ASTM D1238, ISO 1133:2005, BS 2782 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XRW-300A3 |
| Temperature Range | 50–300 °C |
| Heating Rate Options | 120 °C/h and 50 °C/h |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Specimen Stations | 3 |
| Deflection Measurement | Digital micrometer with 0.001 mm resolution and 0–13 mm range |
| Support Span Options | 64 mm and 100 mm (ASTM-compliant adjustable) |
| Heating Medium | Methyl silicone oil (flash point >300 °C, kinematic viscosity <200 cSt) |
| Control Method | Fuzzy PID + PWM modulation |
| Data Acquisition | 7 samples/sec, 4–8 channels per sample |
| Human-Machine Interface | 7-inch capacitive color touchscreen with bilingual (EN/CN) OS |
| Compliance Standards | GB/T 1633, GB/T 1634.1–1634.3, GB/T 8802, ISO 2507, ISO 75, ISO 306, ASTM D1525, ASTM D648 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XRW-300A6 |
| Temperature Range | 50–300 °C |
| Heating Rates | 120 °C/h or 50 °C/h (user-selectable) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Deflection Measurement | Digital micrometer with 0.001 mm resolution, 0–13 mm range |
| Specimen Span | 64 mm or 100 mm (ASTM-compliant adjustable) |
| Sample Stations | 6 independent test positions |
| Heating Medium | Methyl silicone oil (flash point >300 °C, kinematic viscosity <200 cSt, supplied separately) |
| Control Algorithm | Fuzzy PID with PWM output |
| Data Acquisition Rate | 7 samples/second per channel (4–8 channels simultaneously) |
| Human-Machine Interface | 7-inch capacitive color touchscreen, bilingual (English/Chinese) OS |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | Zhonglu |
|---|---|
| Model | XRW-300B4 |
| Origin | Shanghai, China |
| Manufacturer | Zhonglu Instrument Co., Ltd. |
| Application | Heat deflection temperature (HDT) and Vicat softening temperature (VST) testing of thermoplastics, thermosets, fiber-reinforced composites, laminates, and electrical insulating materials |
| Standards Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTM D 1525, ASTM D 648 |
| Temperature Control Range | Ambient to 300 °C |
| Max. Temp. Deviation | ±0.5 °C |
| Heating Rates | 50 °C/h or 120 °C/h (adjustable between 50–120 °C/h) |
| No. of Test Stations | 4 |
| Deflection Measurement Range | 0–10 mm |
| Deflection Accuracy | ±0.005 mm |
| Resolution | 0.001 mm |
| Span Lengths | 64 mm or 100 mm |
| Thermal Expansion Coefficient of Test Frame | <0.005 /100 °C |
| Temperature Sensor Type | High-stability platinum RTD |
| Displacement Sensor | Optical-grating digital micrometer |
| Control Method | PC-based software with real-time curve display and automated reporting |
| Safety Protections | Dual hardware/software temperature limit switches (30 A Korean thermal cutoff), end-of-test auto-halt, administrator password lockout |
| Heating Power | 4000 W |
| Heat Transfer Medium | Methyl silicone oil or transformer oil |
| Cooling | Natural convection above 150 °C |
| Brand | Zhonglu |
|---|---|
| Model | XRW-300C6 |
| Origin | Shanghai, China |
| Manufacturer | Zhonglu Instrument Co., Ltd. |
| Control Interface | 7-inch touchscreen + PC software |
| Test Frames | 6 |
| Temperature Range | Ambient to 300 °C |
| Max Temp Error | ±0.5 °C |
| Heating Rates | 50 °C/h, 120 °C/h, or user-defined between 50–120 °C/h |
| Deformation Range | 0–10 mm |
| Deformation Accuracy | ±0.005 mm |
| Resolution | 0.001 mm |
| Span Lengths | 64 mm and 100 mm |
| Thermal Medium | Methyl silicone oil or transformer oil (user-supplied) |
| Cooling | Natural cooling above 150 °C |
| Safety Protections | Dual hardware/software temperature limit switches, automatic test termination, administrator password lock |
| Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTM D 1525, ASTM D 648 |
| Brand | Zhongruixiang |
|---|---|
| Origin | Beijing, China |
| Model | ZRX-29854 |
| Measurement Range | 0.05–20.00 mg/L |
| Accuracy | ≤±5% FS |
| Repeatability | ≤3% |
| Optical Drift | <0.002 A in 20 min |
| Dimensions | 80 × 230 × 55 mm |
| Weight | 500 g |
| Power Supply | 4 × AA batteries |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| IP Rating | IP65 |
| Light Source | Cold LED with narrow-band interference optical system |
| Brand | Zhongke Aobo |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Customizable per Client Specification |
| Price | USD 42 (FOB Beijing) |
| Material | 99.9% Pure ZrO₂ |
| Density | 6.00 g/cm³ |
| Max Continuous Use Temperature | 2200 °C |
| Melting Point | 2700 °C |
| Thermal Expansion Coefficient | 10 × 10⁻⁶/K |
| Vickers Hardness (HV₀.₅) | 1300 |
| Flexural Strength | 1000 MPa |
| Compressive Strength | 3000 MPa |
| Elastic Modulus | 200 GPa |
| Fracture Toughness | 8 MPa·m¹/² |
| Thermal Conductivity | <2 W/m·K |
| Volume Resistivity (20 °C) | >10¹³ Ω·cm |
| Mohs Hardness | 7 |
| Chemical Stability | Resistant to molten Al, Fe, Ni, Pt, SiO₂-based slags, and acidic/basic melts up to 1900 °C |
| Brand | ZK Electronics |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BLD-200H |
| Force Capacity Options | 5 N / 10 N / 30 N / 50 N / 100 N / 200 N |
| Accuracy | Better than Class 0.5 |
| Resolution | 0.001 N |
| Test Speed Range | 0–500 mm/min (infinitely variable) |
| Clamp Width | 30 mm |
| Dimensions (L×W×H) | 450 × 380 × 240 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | ~38 kg |
| Compliance Standards | GB 4850, GB 7754, GB 8808, GB 13022, GB 7753, GB/T 17200, GB/T 2790, GB/T 2791, GB/T 2792, QB/T 2358 |
| Brand | ZK Electronics |
|---|---|
| Model | HGT-01H |
| Origin | Shandong, China |
| Manufacturer | Yes |
| Type | Domestic |
| Measured Gases | O₂ (standard), CO₂ (optional) |
| Principle | Electrochemical (O₂), NDIR Infrared Absorption (CO₂) |
| Sample Volume | O₂ ≤ 8 mL, CO₂ ≤ 15 mL (standard mode) |
| Resolution | 0.01% |
| Accuracy | ±0.2% (O₂), ±(0.03% + 5% of reading) (CO₂) |
| Response Time | ≤8 s (O₂), ≤10 s (CO₂) |
| Dimensions | 230 × 120 × 82 mm |
| Weight | 0.7 kg |
| Data Storage | 2000 records |
| Power | AC 220 V, 50 Hz |
| Brand | ZK Electronics |
|---|---|
| Model | HST-T01 |
| Origin | Shandong, China |
| Manufacturer | ZK Electronics Co., Ltd. |
| Type | Benchtop Pneumatic Heat Sealing Tester |
| Temperature Range | Ambient to 250 °C |
| Sealing Pressure | 50–700 kPa |
| Sealing Time | 0.01–99.99 s |
| Temperature Control Accuracy | ±1 °C |
| Sealing Area | 300 mm × 10 mm (customizable) |
| Heating Configuration | Dual-zone independent heating (top & bottom jaws) |
| Operating Modes | Manual & Automatic |
| Air Supply Requirement | ≤0.7 MPa, Φ6 mm polyurethane tubing |
| Power | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 550 × 330 × 460 mm |
| Net Weight | ~30 kg |
| Brand | ZKDZ |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SFJ-121 |
| Price Range | USD 170 – 1,400 |
| Standard Compliance | YBB00062004-2015, YBB00252003-2015 |
| Stainless Steel Sieve Mesh Apertures | 0.3 mm, 0.425 mm, 0.5 mm, 0.85 mm |
| Sieve Diameter | Φ200 mm |
| Vibratory Sieving Frequency (Optional Motorized Shaker) | 1400 cycles/min |
| Sieving Particle Size Range (with Motorized Shaker) | 0.025–3 mm |
| Standard Components | Quenched Steel Mortar & Pestle, Magnetic Separator, Four-Stage Stainless Steel Sieve Set (including sieve base and cover) |
| Optional Accessories | Electric Vibratory Sieve Shaker, Pre-Crushing Container |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | PMLS-1000 |
| Max. Load Capacity | 0–1000 N |
| Load Accuracy | ±1% of reading |
| Displacement Resolution | 0.01 mm |
| Displacement Accuracy | ±1% of reading |
| Crosshead Speed Range | 0.05–300 mm/min |
| Speed Accuracy | ±1% |
| Test Stroke | 0–800 mm (excluding fixtures) |
| Dimensions (L×W×H) | 435 × 275 × 1700 mm |
| Power Supply | 220 V, 50 Hz |
| Compliance | GB/T 6344–2008, GB/T 10808–2006, ISO 1798–1997 |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | ZL-B |
| Power Supply | AC 220 V / 50 Hz or DC 9 V high-energy battery |
| Weight | ≤5 kg |
| Power Consumption | ≤300 mW |
| Battery Life | Up to 6 hours continuous operation |
| Dimensions (L×W×H) | 225 × 225 × 140 mm |
| Repeatability Error | ≤3% |
| Test Parameters | Comprehensive contamination index, water content, metallic debris >65 µm, presence of light hydrocarbon dilution |
| Classification Output | “Poor”, “Usable”, or “Good” |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZL-Z |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Model | CS10 |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (Producer) |
| Origin Category | Domestic |
| Measurement Mode | DC |
| Spectral Range | 300–1100 nm (extendable to 1700 nm) |
| Sample Size Range | 1 mm × 1 mm to 100 mm × 100 mm |
| Measurable Parameters | Spectral Responsivity (A/W), External Quantum Efficiency (EQE), Photon-to-Electron Conversion Efficiency, Integrated Short-Circuit Current Density (J<sub>sc</sub>), Beam-Induced Current (BIC) |
| Compatible Sample Types | Inorganic thin-film PV cells, dye-sensitized solar cells (DSSCs), quantum dot solar cells, organic photovoltaics (OPVs), polymer solar cells, perovskite solar cells |
| Bias Light Sources | 75 W tungsten-halogen lamp or 150 W xenon lamp |
| Software | Dedicated EQE acquisition and analysis suite with bias light parameter control |
| Brand | ZOLIX |
|---|---|
| Model | DSR300 Series |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Automation Level | Semi-Automatic |
| Effective Test Area | > Ø40 µm |
| Current Measurement Resolution | 10 pA |
| Light Spot Size | 40 µm (diffraction-limited) |
| Compatible Light Sources | Supercontinuum White-Light Laser, Picosecond Pulsed Lasers, Semiconductor Lasers, Halogen Lamps, Xenon Arc Lamps |
| Key Measurement Functions | Spectral Responsivity (A/W), Monochromatic & Power-Variable I–V, Irradiance-Dependent I–t (200 ms resolution), Bias-Dependent I–t, LBIC Mapping, Linearity Analysis, Response Speed (Transient Photovoltage/Photocurrent) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSR500-LBIC |
| Laser Wavelength (Standard) | 532 nm |
| Laser Power Stability | ≤1% over 4 h |
| Maximum Scan Range (20× objective) | 260 × 200 µm |
| Positional Repeatability | <1 µm |
| Minimum Step Size | 0.2 µm |
| Laser Spot Size | ~2 µm |
| Microscope Objective | Olympus 20×, WD = 7.5 mm, VIS range (350–750 nm) |
| Current Measurement | Keithley 2450 SourceMeter®, Range: 1 nA – 1 A, Noise Floor: 50 pA, Resolution: 20 fA, Accuracy: 0.03% |
| Probe Stage | 65 mm vacuum chuck, XYZ probe motion (12 mm travel, 0.7 µm resolution), sample XY translation (25 mm travel, 5 µm resolution) |
| Software Functions | LBIC mapping, I-V curve point-by-point acquisition, region-of-interest selection, thresholding, contour/3D visualization, spectral responsivity (optional, 200–2500 nm), EQE calculation, data export (TXT/Excel) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | DSR600 |
| Pricing | Upon Request |
| Spectral Range | 200–2400 nm (configurable per variant) |
| Calibration Method | Substitution Method (NIM-traceable) |
| Optical Design | All-reflective, dual off-axis parabolic beam path |
| Spot Size | 1 mm (uniform across spectrum) |
| Measurement Capabilities | Spectral Responsivity (R(λ)), Bias-dependent R(λ), External Quantum Efficiency (EQE), Internal Quantum Efficiency (IQE), Reflectance/Transmittance, Short-Circuit Current Density (J<sub>sc</sub>), I–V Characterization |
| Light Sources | 150 W Xe lamp, 250 W Tungsten-Halogen lamp, EQ-99XFC broadband source |
| Detection | Lock-in amplifier (Stanford Research Systems SR240/SR830 compatible) |
| Imaging Aid | Integrated CCD-based monitoring optical path for real-time beam visualization and sample alignment |
| Brand | ZOLIX |
|---|---|
| Model | DSR600-PDE |
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Quotation | Upon Request |
| Spectral Range (Source + Monochromator) | 300–1100 nm (extendable to 2500 nm) |
| Standard Detector Options | Si (300–1100 nm), InGaAs (900–1700 nm or 2500 nm), NIST-traceable calibration certificates provided |
| Data Acquisition | 2/4-channel, time resolution selectable down to 400 ps, sampling rate up to 2.5 GS/s, record length 10 M points, input impedance 1 MΩ / 50 Ω |
| Precision Source Measure Unit (SMU) | current range 10 nA–1 A, resolution 100 fA, voltage source 0–200 V |
| Programmable Dual-Channel Power Supply | 0–32 V, 1 mV resolution |
| Brand | ZOLIX |
|---|---|
| Model | DSR900 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | EMVA 1288:2020 & GB/T 17444–2013 |
| Light Source Spectral Range | 200–2500 nm |
| Monochromator Resolution | 0.08 nm @ 1200 grooves/mm grating |
| Integrating Sphere Diameter (Monochrome) | 200 mm, Reflectivity >95% (F4 coating, 250–2500 nm) |
| White-light Integrating Sphere | Up to 1100 mm diameter, Output Port ≥100 mm, Uniformity ≤1% (Ø100 mm), Stability ≤1% (30 min) |
| Darkroom Suppression Ratio | >10⁴ (80 dB) across 300–1700 nm |
| Darkroom Dimensions | ≥2000 × 1500 × 1450 mm |
| Motion Control | Motorized XYZ stage (X >100 mm, Z = 100 mm) |
| Data Interface | RS422, LVDS, Camera Link, USB |
| Acquisition Rate | 30 Hz |
| Uncertainty (k=2) | U<sub>rel</sub> = (0.9–4.0)% (800–2500 nm), (1.1–0.9)% (400–800 nm), (2.1–1.1)% (250–400 nm) |