Industry-specific Instruments
Filter
Showing 31–60 of 2098 results
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | GY-2000 |
| Measurement Range | CH₄: 0–100% vol, CO₂: 0–50% vol, H₂S: 0–9999 ppm, O₂: 0–20% vol, pH: 0–14, Temperature: 0–100°C, Pressure: 0–100 kPa |
| Resolution | 0.01% (for gas vol%), ppm-level detection for H₂S |
| Response Time | ≤30 s |
| Detection Principles | Non-dispersive Infrared (NDIR) for CH₄/CO₂, Electrochemical for H₂S/O₂, Potentiometric for pH, RTD/Thermistor for T, Piezoresistive for P |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Prometheus-2.1mm |
| Spot Size | 2.1 mm |
| Dynamic Range | Up to several million cd/m² (customizable) |
| Sampling Rate | Up to 3125 samples/sec (Y flicker mode) |
| CIE Standard Observer | 1931 2° |
| Compliance | USBTMC 1.0, IEEE 488.2 |
| Operating Systems | Windows, Linux (x86_64, i686, ARM), macOS |
| Software Integration | NI-VISA, LabVIEW, LabWindows CVI, Visual Studio |
| Detector Type | High-sensitivity, ultra-low-noise photodiode array |
| Features | Auto-ranging, mechanical shutter, integrated LED alignment pointer, JEITA-compliant flicker calculation engine |
| Filter Accuracy | Enhanced spectral match to CIE 1931 tristimulus curves vs. Hyperion series |
| Brand | ADOS |
|---|---|
| Origin | Germany |
| Model | Biogas 401 |
| Gas Measurement Principles | Electrochemical (O₂, H₂S), Non-Dispersive Infrared (NDIR) (CH₄, CO₂), Thermal Conductivity (H₂) |
| Measurement Ranges | O₂: 0–21 %vol |
| H₂S | 0–50 ppm / 0–5000 ppm (selectable) |
| CH₄ | 0–100 %vol |
| CO₂ | 0–50 %vol |
| H₂ | 0–2 %vol |
| Accuracy | < ±2 % FS |
| Response Time (T90) | ≤ 30 s (typ.) |
| Operating Temperature | +5 °C to +45 °C |
| Power Supply | 230 V AC, 50 Hz / 115 V AC, 60 Hz |
| Power Consumption | 100 VA |
| Dimensions (W×H×D) | 600 × 478 × 500 mm |
| Weight | ~61 kg |
| Output Interfaces | Dual 4–20 mA per channel (6 channels max), RS232/RS485 serial interface, 3 configurable alarm relays + 1 fault relay (230 V, 450 VA) |
| Sample Handling | Peltier-cooled condensate trap, peristaltic sampling pump, adjustable flow control, multi-stage particulate & moisture filtration |
| Brand | adphos |
|---|---|
| Origin | Germany |
| Model | PBT |
| Technology | Ultrafast NIR Thermal Processing |
| Wavelength Range | 800–1200 nm |
| Peak Power Density | Up to 100 MW/ft² (focused line geometry) |
| Substrate Compatibility | PET, PI, PVC, Paper, Foils, Flexible Polymers |
| Process Speed | Up to 300 m/min |
| Operating Mode | Continuous web or batch |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | OsmoTECH HT |
| Pricing | Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Advanced Instruments, Inc. |
| Product Category | Imported |
| Model | OsmoTECH PRO |
| Pricing | Available Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | OsmoTECH |
| Pricing | Available Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | OsmoTECH XT |
| Price | Upon Request |
| Brand | AEMC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Model 6292 |
| Pricing | Available Upon Request |
| Key | Brand: AWT |
|---|---|
| Origin | United Kingdom |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Compliance Standard | EN 54-20 (Fire Detection and Alarm Systems – Smoke Detectors) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | CRTA-2 |
| Compliance | GB 9779–2015, GB 14907–2002, JG/T 157–2009 |
| Airflow Velocity | 3.0 ± 0.3 m/s |
| Test Specimen Dimensions | 150 × 70 × (4–6) mm |
| Timer Range | 0–99 h 99 min |
| Sample Substrate | Asbestos-free fiber-cement board (JC/T 412.1–2006, NAF HV grade, 4–6 mm thick) |
| Wet Film Thickness (Primer) | 80 µm |
| Drying Interval (Primer) | 1–2 h (tack-free) |
| Application Sequence | Primer → Immediate application of intermediate coat → Wind-induced drying test |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CTI-3 |
| Voltage Range | 100–600 V (25 V steps) |
| Electrode Material | Tungsten (99% purity) / Copper electrode holder |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Platinum Electrode Tip | 12 mm, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, 60° ± 5° included angle |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| Solution B | 1.98 ± 0.05 Ω·m |
| Drop Height | 35 ± 5 mm (adjustable) |
| Drop Interval | 30.00 ± 0.01 s (pre-settable) |
| Drops per cm³ | 44–55 |
| Total Drops Programmable | 1–9999 |
| Airflow Velocity | 0.2 m/s |
| Short-Circuit Current | 1.000 ± 0.001 A (voltage drop ≤ 8% at 1.0 A) |
| Tracking Threshold | 0.50 ± 0.05 A for ≥ 2.0 ± 0.2 s |
| Chamber Volume | > 0.5 m³ |
| Ambient Conditions | 0–40 °C, RH ≤ 80%, non-corrosive, vibration-free environment |
| Power Supply | 220 V AC, 0.6 kVA, 50–60 Hz |
| Dimensions (W×D×H) | 1160 × 600 × 1310 mm |
| Weight | Approx. 125 kg |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | GB/T 1692 Resistivity Tester |
| Compliance | GB/T 1692–2008, GB/T 1410, ASTM D257, IEC 60093 |
| Measurement Range | 1 × 10⁶ Ω to 1 × 10¹⁶ Ω |
| Test Voltages | 100 V, 250 V, 500 V, 1000 V (DC) |
| Electrode Configuration | Three-electrode system (main electrode Ø50 mm, guard ring ≥10 mm wide, grounded outer electrode) |
| Accuracy | ±20% of reading |
| Environmental Control Support | Compatible with standard climatic chambers (23 ± 2 °C / 50 ± 5 %RH) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | HDT-VST-300E |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Heating Medium | Methyl Silicone Oil (up to 300 °C) or Transformer Oil (up to 200 °C) |
| Standard Config | 3 Test Stations |
| Load Application | Mechanical Deadweight via Precision Calibration Weights |
| Temperature Sensing | PT100 Platinum Resistance Thermometer |
| Deformation Sensing | High-Resolution Digital Micrometer Sensor (0–10 mm range, 0.001 mm resolution) |
| Control System | 32-bit ARM Embedded Processor with Real-Time Isothermal Ramp Algorithm |
| Compliance | ISO 75-1:1993, ISO 306:1994, GB/T 1633–2000, GB/T 1634–2001 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | LDQ-5 |
| Voltage Range | 50–600 V AC/DC (±1% step accuracy) |
| Electrolyte | NH₄Cl solution (0.1–1.0 wt%), flow rate 0.5–2.0 mL/min (programmable) |
| Electrode Material | Pt-Rh alloy |
| Electrode Angle | 60° ± 5° |
| Electrode Force | 1.0 N ± 0.05 N |
| Trip Current Threshold | 0.5 A ± 10%, arc duration ≥ 2 s |
| Temperature Sensor Accuracy | ±1 °C |
| Humidity Range | 20–80 %RH |
| Data Acquisition | 16-bit resolution, current resolution 0.1 mA |
| Compliance | IEC 60112:2020, ASTM D3638-21, UL 746A, GB/T 4207-2022, VDE 0303-11, IEC 60695-2-2 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VFTA-2 |
| Price Range | USD 3,600 – 7,200 |
| Dimensions (W×D×H) | 1160 × 600 × 1250 mm |
| Combustion Chamber Volume | >0.5 m³ |
| Background | Matte Black, Illuminance ≤20 lux |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 150 W |
| Fuel Gas | Industrial propane, butane, or propane-butane mixture |
| Ignition Timer Range | 0–999.9 s |
| Burn Time Measurement Range | 0–999.9 s |
| Timing Resolution | 0.1 s |
| Flame Positioner Distances | 17 ±1 mm and 20 ±1 mm |
| Flame Height Calibration | 40 ±2 mm (vertical), 25 ±2 mm (horizontal) |
| Combustion Chamber Internal Dimensions | 900 × 600 × 1000 mm |
| Approx. Weight | 80 kg |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-121 |
| Measurement Principle | Four-Terminal (Kelvin) Method with Guarded Electrode System |
| Voltage Range | 10 V – 1000 V (selectable in discrete steps) |
| Resistance Range | 10³ Ω·cm to 10¹⁸ Ω·cm |
| Current Resolution | 0.1 fA |
| Compliance Standards | ASTM D257, IEC 60093, GB/T 1410 |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH (non-condensing) |
| Interface | RS485, USB |
| Safety Features | Overload protection, short-circuit protection, galvanic isolation, shielded enclosure (<5 µV residual noise) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | ZST-121 |
| Price Range | USD 2,100 – 7,000 |
| Resistance Range | 10 Ω to 2×10¹⁷ Ω |
| Resistance Accuracy | ±1% |
| Voltage Settings | 100 V, 250 V, 500 V, 1000 V |
| Voltage Accuracy | ±2% |
| Current Measurement Range | — |
| Display | 3½-digit LCD with backlight |
| Built-in Timer | 1–7 min auto-hold |
| Power Supply | 8×AA batteries (DC 8.5–12.5 V) or external regulated DC source |
| Dimensions (L×W×H) | 280 × 240 × 105 mm |
| Weight | 3 kg |
| Operating Environment | 0–40 °C, RH < 80% |
| Compliance | GB/T 1410–2006, GB/T 31838.1–2019, GB/T 2439–2001, GB/T 1692–2008, GB/T 10064–2006, GB/T 3048.5–2007 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZST-212 High-Resistance Meter |
| Price Range | USD 2,800 – 7,000 |
| Standards Compliance | IEC 60093, ASTM D257, GB/T 31838.2–2019, IEC 62631-3-1, GB/T 1410–2006, GB/T 1692–2008 |
| Display | 4.3-inch HD TFT |
| Voltage Range | ±10 V to ±1500 V DC (continuously adjustable) |
| Resistance Measurement Range | 10⁶ Ω to 10¹⁸ Ω (standard configuration) |
| Minimum Detectable Current | 10 fA |
| Input Impedance | >10¹⁶ Ω |
| Leakage Compensation | Dual-channel active current-voltage feedback network |
| Interface Options | USB 2.0, RS-232C, Handler (TTL/PLC-compatible) |
| Safety Features | ATEX-compliant explosion-proof variant available |
| Environmental Operating Range | −20 °C to +55 °C (industrial grade), relative humidity ≤75% RH (non-condensing) |
| Warm-up Time | ≥30 min required for metrological validity |
| Measurement Modes | Automatic & manual |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Measurement Range | 10⁶ Ω to 10¹⁸ Ω |
| Test Voltages | 10 V, 100 V, 250 V, 500 V, 1000 V DC |
| Input Impedance | >10¹⁴ Ω |
| Current Measurement Sensitivity | down to 1 fA |
| Compliance | IEC 60093, IEC 62631-3-1, ASTM D257, GB/T 1410 |
| Electrode Configuration | Tri-electrode system with guard ring |
| Environmental Operating Conditions | 23 ± 2 °C, 50 ± 5 % RH |
| Data Output | Digital LCD display with real-time current/resistance readout |
| Power Supply | AC mains with internal voltage regulation and EMI filtering |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 Volume & Surface Resistivity Tester |
| Test Voltage Range | 10 V – 1000 V DC (7 precision-adjustable steps, ±1% accuracy) |
| Volume Resistivity Range | 1×10⁴ Ω·cm to 1×10¹⁸ Ω·cm (15 auto-ranging decades, ±5% accuracy at 23°C ±2°C, 50% RH ±5%, 100 V) |
| Surface Resistivity Range | 1×10³ Ω to 1×10¹⁷ Ω (14 auto-ranging decades, ±6% accuracy under same conditions) |
| Minimum Detectable Current | 1×10⁻¹⁴ A |
| Input Impedance | >1×10¹⁴ Ω |
| Electrode System | Tri-electrode configuration (guard, measuring, high-voltage electrodes) |
| Compliance | GB/T 1410–2006, GB/T 31338–2015, ASTM D257–14, IEC 60093:2016, JJG 690–2015 (Class II) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-530 |
| Volume Resistivity Range | 1.0×10⁴ to 1.0×10¹⁸ Ω·cm |
| Surface Resistivity Range | 1.0×10⁴ to 1.0×10¹⁷ Ω |
| Resolution (Volume) | 1.0×10³ Ω·cm |
| Resolution (Surface) | 1.0×10³ Ω |
| Accuracy | ±10% at 100 V |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Sample Thickness (Volume) | 0.01–30 mm |
| Sample Dimension (Surface) | ≥50 mm diameter or side length |
| Compliance | GB/T 1410-2006, ASTM D257-14 |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | MAP-PAK Combi |
| Measurement Range | 0.1–100% O₂ and CO₂ |
| Accuracy | ±1% of reading |
| Response Time | <10 s |
| Data Storage Capacity | Up to 5,000 records |
| Display | Backlit LCD |
| Power | Rechargeable battery (4 units) + AC adapter |
| Compliance | CE-marked, ISO 9001-manufactured instrumentation |
| Software | MP Download Software (Windows-compatible) |
| Optional Accessory | Portable thermal printer |
| Language Support | Multilingual UI (English, French, German, Spanish, Italian, Chinese) |
| Brand | AYALYTICAL |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AgDDI |
| Price | Contact for Quote |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XCS66800/0048 |
| Price Range | USD 999–9,999 |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AcceleSep Petroleum Fraction Rapid Separation System |
| Pricing | Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | EOPC® Automated Polar Compound Separation System |
| Detection Principle | Normal-phase liquid chromatography with UV detection (200 nm) |
| Column Format | Standardized disposable EOPC separation cartridges (pre-packed silica-based) |
| Automation Level | Fully automated sample injection, gradient elution, fraction collection, and real-time UV monitoring |
| Throughput | Up to 6 samples unattended |
| Compliance | Designed to meet requirements of GB 5009.202–2016 “Determination of Polar Compounds in Edible Oils” |
| Solvent Management | Dual 4 L solvent reservoirs with dry-ice–assisted cooling (4 °C to ambient) |
| Flow Control | Valveless precision metering pump (±0.5% flow accuracy, 25 mL/min max) |
| Fraction Collection | Programmable S-type collector with coordinate customization, multi-channel waste/collect switching, compatibility with conical flasks, round-bottom flasks, and beakers |
| UV Detector | Fixed-wavelength 200 nm detector with real-time chromatogram display |
| Display | Integrated LED touchscreen showing pressure, flow rate, gradient profile, and run progress |
| Safety Design | Fully enclosed fluidic path |
| Software | Embedded method library including GB 5009.202–2016-compliant SOPs |
| audit-trail–capable operation log (GLP-supporting metadata | user ID, timestamp, method version, instrument parameters) |
| Origin | Yunnan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AGI-T3 |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Offline Disintegration Tester |
| Sample Capacity | 3-Basket Configuration |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed | 30 ±1 RPM |
| Water Bath Volume | 8 L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Offline Dissolution Tester |
| Model | 280-DS |
| Compliance | Supports eMQ and PVT per USP <711>, <724>, ASTM D6519, and FDA Guidance on Dissolution Equipment Verification |
