| Brand | Alpha |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Premier MV |
| Pricing | Available Upon Request |
| Brand | Alpha |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Premier RPA |
| Pricing | Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | D2020 |
| Measurement Principle | Hydrostatic Weighing (Air/Water Dual-Weight Method) |
| Density Range | 1.05–2.00 g/cm³ |
| Compliance | ISO 2781 |
| Temperature Compensation | Yes (liquid density correction vs. bath temperature) |
| Sample Throughput | 20-position automated carousel |
| Software Integration | Eclipse Daisy v5.x and Enterprise LIMS (barcode-enabled, specification limits, auto-reporting, audit-trail capable) |
| Pre-wetted carrier protocol | Yes |
| Readout Speed | <3 sec per sample post-stabilization |
| Regulatory Context | Supports GLP/GMP workflows with 21 CFR Part 11–compliant electronic records (when deployed with validated LIMS configuration) |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | D2020 |
| Compliance | ASTM D1415, ISO 48, DIN 53519, NF T46-003, BS 903-A26 (International Rubber Hardness) |
| Automation | Fully automated 20-sample queue |
| Test Modes | Pre-configured 1-, 3-, or 5-point indentation sequences |
| Software Integration | Eclipse Daisy and Enterprise LIMS compatible |
| Hardness Head Design | Low-friction, maintenance-optimized indenter assembly |
| Optional Accessory | D2020 Density Tester module |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | densiTECH+ |
| Measurement Principle | Hydrostatic Weighing (ASTM D297, ISO 2781, ASTM D792) |
| Sample Throughput | Up to 4 specimens/min |
| Density Accuracy | ±0.025% of reading |
| Mass Resolution | 0.0001 g |
| Applicable Materials | Cured rubber compounds, thermoplastic elastomers, carbon-black-filled polymers, vulcanizates |
| Compliance | ASTM D297–23, ISO 2781:2015, ISO 1183–1:2019, USP <841> (Density of Solids) |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DG+ |
| Pricing | Available Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DIS030 |
| Pricing | Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DS1200 / DS1500 / DS4000 |
| Pricing | Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DSP-FCI/DSP-Ex |
| Pricing | Available Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FAT-24D |
| Pricing | Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Model | 6020 |
| Measurement Range | -110°C to +20°C dew point |
| Accuracy | ±2°C dew point (full scale) |
| Display | 5-digit red 14mm LED main display + dual 7mm auxiliary LEDs |
| Output | Dual programmable 10A SPCO relays |
| Analog Output | 0–20 mA / 4–20 mA (±0.5% accuracy) |
| Digital Interface | RS485 MODBUS RTU |
| Certifications | ATEX II 1G Ex ia IIC T6 Ga, IECEx, UKCA |
| Sensor Type | Ultra-high-capacitance aluminum oxide |
| Max Cable Length | 1 km |
| IP Rating | IP54 (front panel) |
| Power Supply | 90–250 VAC / 18–28 VDC |
| Operating Temperature | -20°C to +60°C |
| Weight | ≤0.47 kg |
| Brand | Alpha MOS |
|---|---|
| Origin | France |
| Distribution Model | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ASTREE |
| Pricing | Available Upon Request |
| Brand | Alpha MOS |
|---|---|
| Origin | France |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Model | IRIS |
| Pricing | Available Upon Request |
| Brand | ALPHA (USA) |
|---|---|
| Origin | USA |
| Model | Premier MDR |
| Compliance | ASTM D5289, ISO 6520, DIN 53529 |
| Oscillation Frequency | 100 CPM (1.677 Hz) |
| Oscillation Amplitude | ±0.2°, ±0.5°, ±1.0°, ±3.0° (standard ±0.5°) |
| Temperature Range | 40–230 °C (100–446 °F) |
| Torque Range | 0.01–225 dN·m |
| Cavity Volume | ~1.43 cm³ (87.5 mm³ nominal |
| recommended sample volume | 1.84 cm³ / 112.5 mm³) |
| Pressure Channel | 0–8300 kPa (0–1200 psi) |
| Power Supply | 100–130 VAC ±10%, 60 ±3 Hz, 10 A or 200–260 VAC ±10%, 50 ±3 Hz, 5 A |
| Automation Options | 5-position manual test station or 16–144-position automated sample handling system |
| Software | Ultima Enterprise Pathfinder (Eclipse optional) |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PSS |
| Pricing | Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PUT |
| Pricing | Available Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Model | SADPmini2 / SADPmini2-L / SADPmini2-Ex |
| Dew Point Range | −110 °C to +20 °C (selectable ranges: [SR] −110 to −20 °C, [PL] −100 to 0 °C, [BL] −80 to +20 °C) |
| Accuracy | ±2 °C dew point (−90 to +20 °C, NPL-traceable) |
| Repeatability | Better than ±0.3 °C dew point |
| Sensor | Ultra-capacitive aluminium oxide |
| AutoCal Function | Yes |
| Display | Full-color graphical LCD with dual-unit simultaneous readout |
| Data Logging | Onboard (SADPmini2-L/Ex) |
| Connectivity | Bluetooth 4.2 + USB |
| IP Rating | IP66 / NEMA 4X |
| Battery Life | >150 h continuous operation |
| Weight | 1.4 kg |
| Dimensions | 215 × 108 × 124 mm |
| EMC Compliance | BS EN IEC 61326-1 |
| Calibration Certificate | NPL-traceable included |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SS-1 / SS-2 / SS-3 / SS-4 |
| Pricing | Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SS-B/TEG/NGH |
| Pricing | Available Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ALPHA CS-DFT Series |
| Price Range | USD 14,000 – 28,000 |
| Temperature Range | 23–120 °C |
| Frequency Range | 10–30 Hz |
| Static Load Capacity | 0–50 kg (0–110 lb) |
| Dynamic Stroke Range | 0–7.5 mm peak-to-peak |
| Specimen Dimensions | Ø17.8 mm × 25.4 mm (cylindrical) |
| Dimensions (H×W×D) | 122 cm × 76 cm × 61 cm |
| Weight | 250 kg (550 lb) |
| Power Supply | 110 VAC/60 Hz or 220 VAC/50 Hz, 20 A |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T2020DC |
| Pricing | Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T2020SC |
| Pricing | Upon Request |
| Brand | Alpha Technologies |
|---|---|
| Origin | USA |
| Model | ATD2000 ESR™ |
| Application | In-process viscoelastic cure monitoring of aerospace prepregs |
| Compliance | Supports Material State Management™ (MSM) framework per SAE AMS2750, ASTM D5992, and FAA AC 20-107B guidance |
| Software | PACE™ Process Analytics & Control Environment with real-time data streaming and GLP-compliant audit trail |
| Brand | Alpha Technologies |
|---|---|
| Origin | USA |
| Model | ATD2000 ESR™ |
| Application Domain | Thermoset Cure Monitoring in Wind Energy Composites |
| Compliance Framework | Supports ASTM D5992, ISO 3417, and USP <1031> for viscoelastic cure characterization |
| Software Platform | PACE™ Modular Process Analytics Suite with GLP/GMP-Ready Audit Trail |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | tensiTech III |
| Compliance | ASTM D412, ASTM D575, ASTM D624 |
| Software | tensiDATA (data acquisition, control, analysis) |
| Actuation | Pneumatic grips |
| Extensometer | High-elongation digital extensometer |
| Programmability | Fully user-defined crosshead motion profiles and test sequences |
| Sample capacity | Up to 5 specimens per test run |
| Output units | Time, force, stress, strain (configurable) |
| Grip options | O-ring, wire wedge, curved jaw |
| Accessories | Digital thickness gauge, compression platens |
| Enclosure | Service-optimized chassis design |
| Application scope | Tensile, compression, tear, modulus measurement on elastomers and textiles |
| Target materials | Natural rubber, synthetic rubber, silicone rubber, thermoplastic elastomers (TPEs) |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | tensiTech+ |
| Price Range | USD 14,000 – 28,000 |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Alphachron He |
| Pricing | Available Upon Request |
| Brand | ASI |
|---|---|
| Origin | USA |
| Model | Alphachron He-3 |
| Configuration | Integrated Laser-Heating Gas Extraction & QMS System |
| Detection | ³He and ⁴He Isotopes |
| Compliance | Designed for ASTM D7956-15 (He Extraction), ISO/IEC 17025 Traceable Operation |
| Software | Alphachron Control Suite v4.2 with Audit Trail & 21 CFR Part 11 Optional Modules |
| Brand | Amblyonix |
|---|---|
| Origin | USA |
| Model | MODEL1100 |
| Measurement Range | 0–20 mΩ |
| Resolution | 0.1 µΩ |
| Test Current Options | 30 A, 50 A, 80 A, 100 A |
| Accuracy | ±0.5% of reading + 1 µΩ |
| Power Source | Rechargeable Li-ion battery (600+ measurements per charge) |
| Display | 5.6-inch industrial-grade color TFT LCD |
| Interfaces | USB, RS232, DC charging port |
| Protection | Open-circuit and over-temperature protection |
| Dimensions | 246 mm × 157 mm × 64 mm (L×W×H) |
| Weight | Not specified |
| Brand | Amblyonix |
|---|---|
| Origin | USA |
| Model | MODEL1200 |
| Measurement Range | 0–2999.9 µΩ |
| Resolution | 0.01 µΩ (0–99.99 µΩ), 0.1 µΩ (100.0–2999.9 µΩ) |
| Test Current Output | 50/100/150/200 A DC (adjustable, continuous duty) |
| Timing Range | 5–599 s (user-selectable) |
| Display | LCD |
| Data Storage | 200 measurements |
| Interface | USB |
| Power Supply | 120 VAC ±10%, 60 Hz |
| Operating Temperature | –10°C to +40°C (14°F to 104°F) |
| Humidity | ≤80% RH non-condensing |
| Dimensions | 24 × 20 × 12 in |
| Weight | 24.25 lb (unit only), 31 lb (with accessories) |