Leeman Labs China

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGNR
OriginItaly
ModelEXPLORER
Instrument TypePowder X-ray Diffractometer
Power Rating0.0001 kW
Optical ConfigurationSwitchable Bragg-Brentano focusing / Johansson monochromator / Parabolic mirror monochromator
Beam GeometryParallel-beam optics with low-angle reflection capability
Thin-film Thickness Detection Range1–500 nm
Degrees of Freedom for Sample Manipulation5
Modular Units7
Primary ApplicationsPhase identification & quantification, crystallite size and microstrain analysis, residual stress measurement, texture analysis, thin-film characterization, depth profiling, nanocrystalline material assessment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelProdigy
Instrument TypeFull-Spectrum Direct-Reading
Detection Limit0.1 ppm
Precision (RSD)≤1.5%
Stability (Drift)≤2%
Wavelength Range175–900 nm
Optical Resolution≤0.005 nm @ 200 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGNR
OriginItaly
ModelAPD 2000 PRO
Instrument TypePowder X-ray Diffractometer
X-ray Tube Power0.0001 kW (100 W)
Radiation SourceFine-focus Ceramic X-ray Tube
MonochromatorJohannson-type Kα₁ monochromator
Detector TypesScintillation Counter & Energy-Dispersive Detector
Goniometer ControlOptical Encoder
Sample StageMotorized Multi-Sample Rotating Stage with Low-Background Options
Safety SystemDual Redundant Interlock Circuit
ComplianceCE, IEC 61010-1, ISO 9001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEuroVector
OriginItaly
ModelEA3017
Analysis PrincipleDumas Combustion Method
Automation LevelFully Automated Nitrogen Determinator
Nitrogen Range0–100%
Repeatability±0.5% RSD
Sample Mass Capacity≤5 g (solid)
Dimensions (L×W×H)480 mm × 480 mm × 600 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginImported
ModelHydra II AA
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
ComplianceEPA Methods 245.1, 245.5, 245.6, 7470A, 7471B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginImported
Manufacturer TypeAuthorized Distributor
Instrument TypeFull-Spectrum Simultaneous Readout
Detection Limit (Ca at 396.847 nm)0.155 ppb
Precision (RSD)≤0.5%
Long-Term Stability (2-hr drift)≤1.0%
Optical Resolution0.005 nm
RF Generator CoolingAir-Cooled
Plasma Torch AssemblyCeramic RF Load Coil
Optical SystemEchelle Grating with ICCD Detector
ComplianceASTM D1976, ISO 11885, USP <233>, EPA Methods 200.7 & 6010E
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginUSA
ModelProdigy Plus
Instrument TypeFull-Spectrum Direct-Reading ICP Optical Emission Spectrometer
Detection Limit (Zn @ 213.856 nm)< 0.1 µg/L
Precision (RSD)≤ 0.5%
Long-Term Stability (RSD, 4h)≤ 1.0%
Wavelength Range130–1100 nm
Optical Resolution0.005 nm @ 200 nm
DetectorCustom 28 × 28 mm CMOS sensor with 3.38 million effective pixels
Readout Speed>10× faster than conventional CID/CCD detectors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelProdigy DC Arc
Instrument TypeFull-Spectrum Direct-Reading
Detection Limit0.1 ppm
Repeatability≤1.5% RSD
Stability≤2% RSD
Wavelength Range175–900 nm
Optical Resolution≤0.005 nm (at 200 nm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGNR
OriginItaly
ModelSTRESS-X
ComplianceASTM E915, EN 15305
Motion System6-axis robotic arm
Deployment OptionsBenchtop shielded enclosure or mobile four-wheel alloy cart
Measurement PrincipleSin²ψ X-ray diffraction (XRD)
Application ScopeNon-destructive residual stress mapping on metallic components
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGNR
OriginItaly
ModelEDGE
ComplianceASTM E915, EN 15305
DetectorLinear silicon strip detector with single-photon counting technology
CoolingAir-cooled
X-ray SourceInterchangeable microfocus X-ray tubes
Fluorescence SuppressionIntegrated X-ray fluorescence rejection
Measurement TimeMinutes per point (vs. hours for conventional systems)
PortabilityFully integrated into carry-on compliant transport case
Safety OptionsOptional radiation shielding enclosure for benchtop operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginBeijing, China
ModelONH836-G8
Analysis RangeO: 0.01 ppm–5 wt%
N0.01 ppm–3 wt%
H0.01 ppm–0.3 wt%
Analytical PrecisionO/N: ±0.25 ppm
H±0.5 ppm
Detection Limit0.001 ppm
Analysis Time90 s
Pulse Furnace Power10 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginBeijing, China
Instrument TypeDumas Combustion Method
Automation LevelFully Automated
ModelEA3507
ComplianceASTM D515, ISO 14891, AOAC 992.15, EN ISO 16634-1:2021
Detection PrincipleThermal Conductivity Detection (TCD) of N₂ after catalytic combustion and reduction
Sample FormSolid or liquid
Typical Analysis Time< 5 min per sample
Nitrogen Range0.01–100 mg N
PrecisionRSD ≤ 0.5% (n = 10, 10 mg N standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandESI
OriginImported
Manufacturer TypeAuthorized Distributor
ModelEdibleOil ICP
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGNR
OriginItaly
ModelTX 2000
ConfigurationBenchtop/Floor-standing
Application TypeGeneral-purpose
Elemental RangeNa (11) to Pu (94)
Quantification Range10 pg – 100%
Energy Resolution124 eV (at Mn Kα)
Repeatability0.1% RSD
DetectorPeltier-cooled Silicon Drift Detector (SDD)
Excitation SourceSwitchable Mo/W anode X-ray tube
Angular ControlHigh-precision optical encoder stepper motor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginImported
ModelHydra II C
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
ComplianceEPA Method 7473, SN/T 3511–2013, HJ 910–2017, HJ 917–2017, HJ 923–2017, Cosmetics Safety Technical Specifications (2015 Edition)
Sample IntroductionDirect Solid/Liquid Injection Without Prior Digestion
Optical DesignDual-Beam, Dual-Cell Configuration with Real-Time Baseline Monitoring
Moisture ManagementIntegrated Desiccant Drying Tube
Operational ReadinessAmbient-Temperature Operation, No Preheating Required
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBerghof
OriginGermany
ModelBSB-939-IR
Instrument TypeSub-boiling Distillation Apparatus
Construction MaterialsTFM-PTFE, PTFE, and PFA only (no quartz or metal components)
ApplicationUltra-high-purity acid production for trace elemental analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginUSA
ModelProdigy7
Instrument TypeFull-Spectrum Direct-Reading ICP-OES
Detection Limit (Zn at 213.856 nm)<0.1 µg/L
Precision (RSD)≤1.0%
Stability (RSD over 4 hours)≤1.0%
Wavelength Range165–1100 nm
Optical Resolution≤0.007 nm @ 200 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandESI
OriginImported
Manufacturer TypeAuthorized Distributor
ModelDX
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGNR
OriginItaly
ModelAREX L
ComplianceASTM E975
Measurement PrincipleX-ray Diffraction (XRD)
Detection Limit≤0.5% austenite
Target MaterialFerrous alloys (steel, cast iron, heat-treated components)
X-ray SourceHigh-power ceramic X-ray tube
OpticsHigh-focus single-capillary collimator
DetectorHigh-resolution CCD detector
Stability ControlPrecision closed-loop feedback circuit for HV/current regulation
Data AcquisitionMulti-peak intensity ratio analysis (austenite {220}, {311} / ferrite {200}, {211})
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne Leeman Labs
OriginBeijing, China
ModelCS844-LM
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemHigh-Frequency Induction Furnace
Carbon Range0.0001–6.0 wt%
Sulfur Range0.0001–3.5 wt%
Sensitivity0.000001 wt%
Precision±1 ppm
Analysis Time20–40 s
Furnace Output Power3.5 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandESI
OriginImported
Manufacturer TypeAuthorized Distributor
ModelbrineFAST
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGNR
OriginItaly
ModelAreX D
X-ray Source50 W Mo microfocus tube with Zr filter
CoolingAir-cooled
DetectionHigh-resolution USB camera for precise sample positioning
SafetyInterlocked X-ray shielding system
Measurable Diffraction PeaksAustenite (220), (311)
Measurement Time< 3 minutes per sample
ComplianceASTM E975-22 Standard
Minimum Detectable Austenite Content0.5 vol%
Sample CompatibilityFlat, polished metallic specimens (steel, stainless steel, tool steels, bearing alloys)
SoftwareIntegrated Windows-based analysis suite with peak integration, phase quantification, and report generation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBerghof
OriginGermany
ModelSW-Entry
Cavity ClassIndustrial-grade
Sample Capacity24 vessels
Microwave SourceSingle Magnetron
Max Temperature230 °C
Max Pressure75 bar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGNR
OriginItaly
ModelHORIZON
ConfigurationBenchtop/Floor-standing
Application TypeGeneral-purpose
Elemental RangeNa (11) to Pu (94)
Quantification Range10 pg – 100%
Energy Resolution124 eV (at Mn Kα)
Repeatability≤ 0.1% RSD
Show next
InstrumentHive
Logo