- All
- Favorite
- Popular
- Most rated
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Precision (RSD) | ≤1.5% |
| Stability (Drift) | ≤2% |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Detection Limit (Ca at 396.847 nm) | 0.155 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (2-hr drift) | ≤1.0% |
| Optical Resolution | 0.005 nm |
| RF Generator Cooling | Air-Cooled |
| Plasma Torch Assembly | Ceramic RF Load Coil |
| Optical System | Echelle Grating with ICCD Detector |
| Compliance | ASTM D1976, ISO 11885, USP <233>, EPA Methods 200.7 & 6010E |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy Plus |
| Instrument Type | Full-Spectrum Direct-Reading ICP Optical Emission Spectrometer |
| Detection Limit (Zn @ 213.856 nm) | < 0.1 µg/L |
| Precision (RSD) | ≤ 0.5% |
| Long-Term Stability (RSD, 4h) | ≤ 1.0% |
| Wavelength Range | 130–1100 nm |
| Optical Resolution | 0.005 nm @ 200 nm |
| Detector | Custom 28 × 28 mm CMOS sensor with 3.38 million effective pixels |
| Readout Speed | >10× faster than conventional CID/CCD detectors |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy DC Arc |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Repeatability | ≤1.5% RSD |
| Stability | ≤2% RSD |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm (at 200 nm) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy7 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit (Zn at 213.856 nm) | <0.1 µg/L |
| Precision (RSD) | ≤1.0% |
| Stability (RSD over 4 hours) | ≤1.0% |
| Wavelength Range | 165–1100 nm |
| Optical Resolution | ≤0.007 nm @ 200 nm |
| Brand | Zeltex |
|---|---|
| Origin | USA |
| Model | ZX-50IQ |
| Instrument Type | Portable |
| Application Domain | Cereal & Oilseed Grains |
| Operating Principle | In-situ and Portable NIR Spectroscopy |
| Wavelength Range | 893–1045 nm |
| Scan Rate | 10 scans/second |
| Data Acquisition Interval | 10 Hz |
| Measurement Mode | Diffuse Reflectance / Transmission |
| Chemometrics Software | RIMP |
| Compliance Standard | GB/T 24870–2010 |
Show next