| Brand | EuroVector |
|---|---|
| Origin | Italy |
| Model | EA3017 |
| Analysis Principle | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0–100% |
| Repeatability | ±0.5% RSD |
| Sample Mass Capacity | ≤5 g (solid) |
| Dimensions (L×W×H) | 480 mm × 480 mm × 600 mm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Model | Hydra II AA |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Compliance | EPA Methods 245.1, 245.5, 245.6, 7470A, 7471B |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Model | ONH836-G8 |
| Analysis Range | O: 0.01 ppm–5 wt% |
| N | 0.01 ppm–3 wt% |
| H | 0.01 ppm–0.3 wt% |
| Analytical Precision | O/N: ±0.25 ppm |
| H | ±0.5 ppm |
| Detection Limit | 0.001 ppm |
| Analysis Time | 90 s |
| Pulse Furnace Power | 10 kW |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated |
| Model | EA3507 |
| Compliance | ASTM D515, ISO 14891, AOAC 992.15, EN ISO 16634-1:2021 |
| Detection Principle | Thermal Conductivity Detection (TCD) of N₂ after catalytic combustion and reduction |
| Sample Form | Solid or liquid |
| Typical Analysis Time | < 5 min per sample |
| Nitrogen Range | 0.01–100 mg N |
| Precision | RSD ≤ 0.5% (n = 10, 10 mg N standard) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Model | Hydra II C |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Compliance | EPA Method 7473, SN/T 3511–2013, HJ 910–2017, HJ 917–2017, HJ 923–2017, Cosmetics Safety Technical Specifications (2015 Edition) |
| Sample Introduction | Direct Solid/Liquid Injection Without Prior Digestion |
| Optical Design | Dual-Beam, Dual-Cell Configuration with Real-Time Baseline Monitoring |
| Moisture Management | Integrated Desiccant Drying Tube |
| Operational Readiness | Ambient-Temperature Operation, No Preheating Required |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Model | CS844-LM |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | 0.0001–6.0 wt% |
| Sulfur Range | 0.0001–3.5 wt% |
| Sensitivity | 0.000001 wt% |
| Precision | ±1 ppm |
| Analysis Time | 20–40 s |
| Furnace Output Power | 3.5 kW |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DH603-G4 |
| Instrument Type | Diffusion Hydrogen Analyzer |
| Analysis Range | 0.05–3000 mL/100g |
| Analytical Precision | 0.001 mL/100g |
| Sensitivity | ±1% |
| Analysis Time | 3–10 min |
| Brand | MOL |
|---|---|
| Origin | Germany |
| Model | CS1000 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | Resistance Furnace |
| Carbon Range | 0.005–100 wt% |
| Sulfur Range | 0.005–20 wt% |
| Sensitivity | 0.01 ppm |
| Accuracy | ±1% of reading |
| Analysis Time | 60–120 s |
| Furnace Power Output | 1 kW |
| Maximum Furnace Temperature | 1550 °C |
| Detector Configuration | Up to 4-channel NDIR cells |
| Compliance | ASTM E1019, ISO 15350, ISO 4935 |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EA3500 |
| Pricing | Upon Request |
| Brand | EuroVector |
|---|---|
| Origin | Italy |
| Model | EA3100 |
| Measurable Elements | C, H, N, S, O |
| Analysis Time | CN ≤ 3 min |
| Detection Limit | ppm-level |
| Measurement Accuracy | ±0.1% (relative) |
| Sample Introduction | Tin or silver capsules, filled to capacity |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Combustion Temperature | TurboFlash dynamic combustion up to 1800 °C |