Life Science Instruments
Filter
Showing 691–720 of 2783 results
| Brand | BM |
|---|---|
| Origin | Shanghai, China |
| Model | BM-19AY |
| Instrument Type | Upright Fluorescence Microscope |
| Excitation Source | 100 W High-Pressure Mercury Lamp |
| Observation Head | Trinocular, 30° Inclined, 360° Rotatable |
| Eyepieces | Wide-Field Plan Eyepieces (10×/Φ22 mm) |
| Objectives | Infinity-Corrected Fluorescence Plan Achromatic Objectives (4×, 10×, 40×, 100× oil) |
| Illumination | Epi-Fluorescence (U, V, B, G filter sets) + Transmitted Köhler Illumination (12 V/30 W Halogen) |
| Focusing | Coaxial Coarse/Fine Manual Focus (30 mm Travel, 0.002 mm Fine Graduation) |
| Stage | 180 × 150 mm Mechanical Stage with 75 × 50 mm Travel and 0.1 mm Vernier Scale |
| Tube Lens Focal Length | 200 mm |
| Optical System | Infinity-Corrected (∞) |
| Regulatory Status | Not a Medical Device |
| Brand | BM-Beam |
|---|---|
| Origin | Shanghai, China |
| Model | BM-40YD |
| Instrument Type | Inverted Fluorescence Microscope |
| Research Grade Classification | Yes |
| Fluorescence Filter Cubes | UV1 (385 nm center), B1 (470 nm center), G1 (560 nm center), R1 (630 nm center, optional) |
| Light Source | LED-based, 385 nm / 470 nm / 560 nm triple-channel excitation |
| Control Interface | PC software-controlled fluorescence filter turret and illumination |
| Focusing Mechanism | Coaxial coarse/fine manual focus with 0.002 mm fine adjustment resolution |
| Condenser | NA 0.3, long working distance (WD = 72 mm), removable, phase-adjustable slider with dual centering knobs |
| Observation Head | 45° inclined hinge-type trinocular, 360° rotatable, interpupillary distance 50–75 mm, dual-mode beam splitter (100% eyepiece / 100% camera) |
| Stage | Three-layer mechanical stage, 215 × 250 mm platform, 120 × 80 mm travel range |
| Objective Lenses | Infinity-corrected semi-apochromatic plan fluor objectives (4×/0.13, WD 18.5 mm |
| Optical System | Infinity-corrected semi-plan achromat optical design |
| Illumination | Adjustable warm/cool white transmitted LED, independent intensity control per channel, IR motion sensing, LED fluorescence status indicator |
| Fluorescence Light Engine | Four-position motorized filter turret with servo-driven gear transmission, integrated LED driver for simultaneous or sequential excitation control |
| Brand | BMG LABTECH |
|---|---|
| Origin | Germany |
| Model | CLARIOstar ACU Ischemia-Reperfusion Research System |
| Application | High-throughput, real-time intracellular oxygen monitoring under physiologically relevant O₂/CO₂-controlled conditions |
| Regulatory Status | Research Use Only (RUO), not for clinical diagnostic use |
| Compliance | Designed to support GLP-compliant workflows and FDA 21 CFR Part 11–ready software configurations (with optional audit trail and user access control) |
| Brand | BMG LABTECH |
|---|---|
| Origin | Germany |
| Model | Micro-GCM omega |
| Detection Modes | Absorbance (220–1000 nm), Fluorescence (up to 8 channels), Luminescence |
| Temperature Control | Ambient +4 °C to 45 °C (optional up to 65 °C), ±0.1 °C accuracy, sandwich dual-zone heating |
| Humidity Control | Compatible with specialized breathable, anti-evaporation microplate sealing films |
| Gas Control | Atmospheric Control Unit (ACU) for independent or coupled regulation of O₂ (0.1–20%) and CO₂ (0.1–20%) |
| Shaking | Linear, orbital, or dual-orbital |
| Detection Speed | <1 second per well for full-spectrum absorbance (220–1000 nm) |
| Plate Formats | 6–384-well microplates |
| Software | Preconfigured assay templates, kinetic data acquisition, GLP-compliant audit trail, EC₅₀/IC₅₀ fitting, 4-parameter logistic regression, standard curve generation |
| Automation | Dual high-precision injectors (min. 3 µL injection volume, dead volume <30 µL, up to 4 injections/well with simultaneous read) |
| Brand | Bmseed |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MEASSuRE |
| Electrode Spacing Options | 200, 330, 370, 400, 447, 960, 1140 µm |
| Electrode Diameter Options | 30, 70, 100, 200 µm |
| Electrode Count Options | 32, 60, 96 |
| Application | In Vitro Electrophysiological & Mechanobiological Studies |
| Brand | Bo-Semitech |
|---|---|
| Origin | Guangdong, China |
| Chip Material | Organic Polymer |
| Chip Type | Continuous-Flow Microfluidic Chip |
| Target Analytes | Proteins |
| Detection Sensitivity | 1–10 pg/mL (e.g., IL-6) |
| Dynamic Range | 1–1000 pg/mL (R² > 0.99) |
| Readout Format | Portable Fluorescence Reader or Smartphone-Coupled Imaging Module |
| Multiplex Capacity | Up to 16 Analytes per Chip |
| Regulatory Classification | In Vitro Diagnostic (IVD) Microfluidic Platform |
| Compliance Context | Designed for CLIA-waived and point-of-care use under ISO 13485-aligned manufacturing practices |
| Brand | Bo-Semitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JX-1G |
| Price | USD 140,000 (FOB) |
| Sample Types | Serum, Whole Blood |
| Sample Volume | >10 µL |
| Dynamic Range | 1–10,000 fg/mL |
| Limit of Detection (LOD) | ≤10 fg/mL |
| Assay Time | 2 min/test |
| Precision (CV) | <10% |
| Multiplex Capacity | 8-plex |
| Brand | Bo-Semitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Xinqiji JX-8B |
| Price | USD 42,000 (FOB Guangdong) |
| Detection Principle | Single-Molecule Array (Simoa) Technology |
| Assay Time | ≤10 min per run |
| Analyte Range | 0.054–1000 pg/mL (IL-6) |
| LOD (IL-6) | 0.054 pg/mL |
| LOD (PCT) | <10 pg/mL |
| Linearity (R²) | >0.99 across multiplex panels |
| Intra-assay CV | <16.2% (n=16) |
| Multiplex Capacity | Up to 8 human or murine cytokines per chip |
| Compatible Biomarkers | Human IL-4, IL-5, IL-8, TNF-α, IL-6, IFN-γ, IL-1β |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BAT70/150/250/360/600-GSH |
| Air Circulation | Forced Convection |
| Temperature Range | 4°C to 60°C |
| Temperature Accuracy | ±0.1°C |
| Temperature Fluctuation | ±0.2°C |
| Temperature Uniformity | ±0.8°C (within same horizontal plane) |
| Capacity | 70 L / 150 L / 250 L / 360 L / 600 L |
| External Dimensions (W×D×H) | 570×600×1220 mm (BAT70-GSH) |
| Brand | Boante |
|---|---|
| Model | BAT260/360/500/650/850/1050/1600/2500-GZ |
| Temperature Range | 5–50 °C |
| Temperature Uniformity | ±1 °C (at same shelf level) |
| Humidity Range | Not applicable (GZ series is humidity-free) |
| 光照 Intensity | 0–600 μmol/m²/s (0–100% continuously adjustable, measured at 100 mm from LED source) |
| Light Source | Top-mounted horizontal LED array with independent per-shelf dimming control |
| Capacity | 260–2500 L |
| Control System | BAT200PG intelligent controller with 7-inch color touchscreen, 24-segment programmable cycle (real-time Beijing time), adaptive three-stage fuzzy logic PID algorithm |
| Data Logging | Internal storage for ≥5 years of timestamped temperature and operational data |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutoff, overload protection, independent mechanical overtemperature limiter |
| Certifications & Compliance | Designed to support GLP-compliant workflows |
| Brand | Boante |
|---|---|
| Model | BAT70/150/250/360/460/600GZ-M or BAT70/150/250/360/460/600QH-M |
| Temperature Range | 5–50 °C |
| Temperature Uniformity | ±1 °C (at same level) |
| Humidity Range (QH-M only) | 40–80 %RH (with light on), 50–90 %RH (with light off), within 15–45 °C operating range |
| Humidity Control Accuracy | ±1 %RH |
| Illuminance | Up to 12,000 lx (adjustable in 6 levels, measured at 100 mm from LED source) |
| Light Source | 4000 K white LED array mounted on door |
| Control Interface | 4.3″ color LCD (GZ-M) or optional 7″ touch screen (QH-M) |
| Programming | 30-segment ramp-soak profile with real-time countdown |
| Cooling System | Balanced refrigeration with auto-defrost heat-pump cycle |
| Interior Power Outlet | 220 V AC, 10 A |
| Chamber Volume | 70 / 150 / 250 / 360 / 460 / 600 L |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutout, overload protection |
| Brand | Boante |
|---|---|
| Model | BAT70/150/250/360/600-MGSH |
| Origin | Hubei, China |
| Control Method | Digital Touchscreen Interface |
| Air Circulation | Forced Convection |
| Temperature Range | 4°C to 60°C |
| Temperature Fluctuation | ±0.2°C |
| Temperature Uniformity | ±0.8°C (within same horizontal plane) |
| Capacity | 70 L / 150 L / 250 L / 360 L / 600 L |
| External Dimensions (W×D×H) | 570×600×1220 mm (BAT70) to 960×970×1790 mm (BAT600) |
| Internal Dimensions (W×D×H) | 400×350×500 mm (BAT70) to 800×680×1100 mm (BAT600) |
| Shelving | Adjustable Stainless Steel, 2–4 Levels |
| Safety Protections | Compressor Overheat, Fan Overheat, Overtemperature, High-Pressure Cut-off, Overload Protection |
| Optional Features | UV Germicidal Lamp (internal), RS485/USB Data Interface, Thermal Printer Output, Remote Monitoring via WeChat Mini-Program |
| Brand | Boante |
|---|---|
| Model | BAT180/280/360/460/600GZ-4M & BAT180/280/360/460/600QH-4M |
| Temperature Range | 5–50 °C (10–50 °C with illumination) |
| Temperature Uniformity | ±1.0 °C (at same shelf level) |
| Humidity Range | 40–80 %RH (with lights ON) |
| Humidity Control Accuracy | ±1 %RH |
| Illuminance Range | 0–20,000 lx (7-step programmable intensity, measured at 100 mm from LED source) |
| Light Spectrum | 4000 K white LED, mounted on three inner door surfaces |
| Chamber Volume | 180 / 280 / 360 / 460 / 600 L |
| Control System | BAT200PG embedded OS with 5-inch color touchscreen interface |
| Programming | 24-segment time-based profile (real-time clock synchronized) for simultaneous independent control of temperature, humidity, and light intensity |
| Cooling Method | Thermal bypass refrigeration system |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cut-off, overload protection |
| Construction | Double-glazed inner observation door |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model Series | BAT600/800/1000/1250/1700/2000PG-HT (High-Temp) / BAT600/800/1000PG-DW (Low-Temp) |
| Temperature Range | 5–45 °C (HT) |
| Temp. Uniformity | ±0.5 °C (HT), ±1.0 °C (DW) |
| Temp. Stability | ±0.2 °C |
| Humidity Range | 40–80 %RH (light on), 50–90 %RH (light off) |
| Humidity Control Accuracy | ±1 %RH |
| Light Intensity | 0–600 µmol·m⁻²·s⁻¹ (at 100 mm from LED source) |
| Light Spectrum | Full visible spectrum (400–700 nm PAR) |
| Illumination Control | 0–100% stepless dimming per shelf |
| Chamber Volume | 600–2000 L |
| Shelf Configuration | Dual-layer independent lighting control |
| External Dimensions | Up to 1980 × 920 × 2080 mm |
| Internal Dimensions | Up to 1874 × 728 × 1500 mm |
| Power Management | Adaptive thermal bypass refrigeration with electromagnetic defrost |
| Control System | BAT200PG OS, 7-inch color touchscreen, 24-segment programmable logic, APID fuzzy algorithm, 5-year onboard data logging |
| Safety Protections | Compressor overheat, fan overheat, over-temperature, high-pressure cut-off, overload protection |
| Compliance | Designed for GLP-compliant environmental simulation |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT70/150/250/360/460/600-SH |
| Air Circulation | Forced Convection |
| Temperature Range | 4°C to 60°C |
| Temperature Accuracy | ±0.1°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Uniformity | ±1.0°C (within same shelf plane) |
| Capacity | 70 L / 150 L / 250 L / 360 L / 460 L / 600 L |
| External Dimensions | 600×570×1220 mm (BAT70-SH) |
| Internal Dimensions | 400×350×500 mm (BAT70-SH) |
| Shelf Count | 2–4 adjustable stainless-steel shelves |
| Controller | Full-color LCD with PID algorithm, real-time parameter display, timer range 0–9999 min or 0–999 h |
| Safety Features | Compressor overheat protection, fan overheat protection, overtemperature cutoff, high-pressure shutdown, motor overload protection |
| Optional | UV germicidal lamp (for inner door or shelf), RS485/USB interface, thermal printer output, remote monitoring capability |
| Brand | Boante |
|---|---|
| Model | BAT600/800/1000/1250/1500/2000-SHM |
| Origin | Hubei, China |
| Temperature Range | 5–45 °C (10–45 °C under illumination) |
| Temperature Uniformity | ±0.5 °C (within same shelf plane) |
| Temperature Stability | ±0.2 °C |
| Humidity Range | 50–95 %RH (operable within 15–45 °C ambient) |
| Humidity Control Accuracy | ±1 %RH |
| Humidity Fluctuation | ±3 %RH (within same shelf plane) |
| Light Intensity Range | 0–600 µmol·m⁻²·s⁻¹ (0–100 % stepless dimming) |
| Light Source | LED, visible spectrum only |
| Illumination Configuration | Top-mounted horizontal lighting with per-shelf independent control |
| Chamber Volumes | 600 / 800 / 1000 / 1250 / 1500 / 2000 L |
| External Dimensions (W×D×H) | 850×805×1900 mm (BAT600-SHM) to 1980×920×2080 mm (BAT2000-SHM) |
| Internal Dimensions (W×D×H) | 740×585×1350 mm (BAT600-SHM) to 1874×728×1500 mm (BAT2000-SHM) |
| Shelving | 2-tier standard configuration |
| Cooling Method | Hot-gas bypass refrigeration with electromagnetic defrost |
| Control System | BAT200PG OS, 7-inch color touchscreen, 24-segment programmable timeline with real-time Beijing time synchronization |
| Security | Four-level password management (Factory Admin / User Admin / Operator / Engineer) |
| Data Logging | ≥5 years internal storage with timestamped audit trail |
| Safety Protections | Compressor overheat, fan overheat, over-temperature, high-pressure cut-off, overload protection |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT1080-WPG / BAT1600-WPG / BAT3200-WPG |
| Temperature Range | 5–45 °C (dark), 10–45 °C (light-on) |
| Temperature Uniformity | ±0.5 °C (within horizontal plane) |
| Temperature Stability | ±0.2 °C |
| Humidity Range | 40–80 %RH (light-on), 50–90 %RH (light-off), within 15–45 °C operating range |
| Humidity Control Accuracy | ±1 %RH |
| Light Intensity | 0–1200 µmol·m⁻²·s⁻¹ (measured at 100 mm from LED panel), 0–100 % infinitely adjustable |
| Light Source | High-efficiency white LED array, visible spectrum (400–700 nm) |
| Illumination Configuration | Top-mounted horizontal LED panels with modular, evenly distributed layout |
| Chamber Volume | 1080 L / 1600 L / 3200 L |
| External Dimensions (W×D×H) | 1800×770×1950 mm (BAT1080), 1850×900×2050 mm (BAT1600), 2980×1020×2050 mm (BAT3200) |
| Internal Dimensions (W×D×H) | 1200×600×1500 mm (BAT1080), 1250×800×1600 mm (BAT1600), 2350×850×1600 mm (BAT3200) |
| Max Plant Height Capacity | 1250 mm (BAT1080), 1350 mm (BAT1600 & BAT3200) |
| Total Cultivation Area | 0.63 m² (BAT1080), 1.03 m² (BAT1600), 1.82 m² (BAT3200) |
| Control System | BAT200PG embedded OS, 7-inch color touchscreen interface, 24-segment programmable cycle with real-time clock synchronization |
| Control Algorithm | Adaptive three-stage fuzzy logic APID (Adaptive Proportional-Integral-Derivative) for simultaneous temperature and humidity regulation |
| Data Logging | Internal storage for ≥5 years of timestamped environmental data (temperature, humidity, light intensity, operational status) |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutout, motor overload, door-open alarm |
| Defrost Method | Electromagnetic valve–controlled hot-gas bypass defrost |
| Optional Modules | CO₂ concentration control (0–2000 ppm), multi-spectral LED lighting (blue/red/far-red tunable), closed-loop dimming system, Ethernet/WiFi remote monitoring and control |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT250PG-2 / BAT360PG-2 / BAT460PG-2 / BAT600PG-2 |
| Temperature Range | 5–45 °C (dark), 10–45 °C (with illumination) |
| Temperature Uniformity | ±0.5 °C (within zone) |
| Temperature Stability | ±0.2 °C |
| Humidity Range | 40–80 %RH (light on), 50–90 %RH (light off), within 15–45 °C operating range |
| Humidity Control Accuracy | ±1 %RH |
| Humidity Fluctuation | ±3 %RH |
| Illumination Intensity | 0–600 µmol·m⁻²·s⁻¹ (adjustable 0–100% steplessly) |
| Light Source | LED, visible spectrum |
| Light Distribution | independent top-mounted horizontal illumination per shelf |
| Chamber Volume | 250 L / 360 L / 460 L / 600 L |
| External Dimensions | 1120×720×1900 mm (BAT250PG-2) to 1625×880×2050 mm (BAT600PG-2) |
| Internal Dimensions | 600×520×700 mm × 2 zones (BAT250PG-2) to 1100×680×840 mm × 2 zones (BAT600PG-2) |
| Shelf Configuration | 2 independent dual-zone compartments, 4 total shelves (2 per zone), max plant height: 500–640 mm |
| Control System | BAT200PG OS, 7-inch color touchscreen, 24-segment programmable timeline with real-time Beijing time synchronization |
| Control Algorithm | adaptive three-stage fuzzy logic APID control |
| Data Logging | internal storage for ≥5 years |
| Security | four-tier password management (Factory Admin / User Admin / Operator / Engineer) |
| Defrosting | electromagnetic valve-based full-cycle defrost |
| Safety Protections | compressor overheat, fan overheat, overtemperature, high-pressure cutout, overload protection |
| Brand | Boante |
|---|---|
| Model | BAT360-GZ |
| Temperature Range | 5–50 °C |
| Illumination Intensity | 0–600 μmol/m²/s (0–100% stepless dimming) |
| Uniformity | ±1 °C (within same shelf level) |
| Temperature Accuracy | ±0.1 °C |
| Control System | BAT200PG OS with 7-inch color touchscreen |
| Programmability | 24-segment time-temperature-light-humidity profile |
| Cooling Method | Hot-gas bypass refrigeration |
| Light Source Mounting | Top-mounted, horizontal, per-shelf independent control |
| Shelf Configuration | Adjustable spacing and quantity |
| Safety | Dual-limit temperature protection, compressor/fan overheat, overpressure, overload, and short-circuit safeguards |
| Data Logging | Internal storage ≥5 years |
| Compliance | Supports GLP-compliant audit trails (via optional USB/R485 data export), meets ISO 17025 environmental monitoring prerequisites for plant physiology labs |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT360/600/800/1000ZW-4 |
| Temperature Range | 5–45 °C |
| Temp. Uniformity | ±0.5 °C (within chamber plane) |
| Temp. Stability | ±0.2 °C |
| Humidity Range | 40–80 %RH (with lights on) |
| Humidity Stability | ±5 %RH |
| Light Intensity | 0–800 lx (also specified as 0–1000 μmol·m⁻²·s⁻¹ at 100 mm distance) |
| Spectral Channels | 4 independent LED bands — 450 nm (blue), 660 nm (red), 730 nm (far-red), and 6500 K white light |
| Light Control | 0–100 % continuous dimming per channel |
| Illumination Mode | Top-mounted horizontal LED array with adjustable light-layer shelves |
| Chamber Volume | 600 L / 800 L / 1000 L |
| External Dimensions | 850×805×1900 mm (BAT600ZW-4) |
| Compliance | Designed for GLP-compliant plant phenotyping, photobiology, and controlled-environment research |
| Brand | Boante |
|---|---|
| Model | BAT43-FS / BAT44-FS |
| Tier Count | 4 |
| Column Count | 3 / 4 |
| Dimensions (mm) | 420×140×232 / 560×140×232 |
| Compatible Cryobox Size | 133×133×54 mm (standard 81-well format) |
| Paper Cryobox Capacity per Tier | 12 / 16 |
| Plastic Cryobox Capacity per Tier | 12 / 16 |
| Material | 0.6–1.0 mm Stainless Steel (AISI 304 equivalent) |
| Construction | Precision-stamped panels, resistance spot-welded joints |
| Customization Available | Yes (lead time ~15 working days) |
| Warranty | 12 months against manufacturing defects under normal ULT operation (−80 °C) |
| Brand | Boante |
|---|---|
| Model Series | BAT53-FS, BAT54-FS, BAT55-FS |
| Tier Count | 5 |
| Column Count | 3 / 4 / 5 |
| Dimensions (mm) | 420×140×295 |
| Compatible Cryobox Format | 133×133×54 mm (standard) |
| Paper Cryobox Capacity (81-well) | 15 / 20 / 25 per rack |
| Plastic Cryobox Capacity (100-well) | 15 / 20 / 25 per rack |
| Material | 0.6–1.0 mm stainless steel (AISI 304 equivalent) |
| Construction | Panel-stamped body with precision resistance spot welding |
| Operating Temperature Range | –86 °C to –150 °C |
| Customization Lead Time | ~15 working days |
| Warranty | 12 months against manufacturing defects |
| Brand | Boante |
|---|---|
| Model | BAT600-ZDSS |
| Origin | Hubei, China |
| Type | Custom-Size Artificial Climate Incubator for Plant Phenotyping and Gene Function Studies |
| Temperature Range | 5–45 °C (Control Accuracy ≤ ±0.2 °C |
| Humidity Range | 30–95 % RH (Control Accuracy ≤ ±5 % RH) |
| Lighting | Top-mounted LED array with full-spectrum white (350–800 nm), 660 nm red, 470 nm blue, and 720 nm far-red |
| spectral ratio configurable (e.g., R | B:W:FR = 5:2:2:1) |
| Control System | 15.6″ industrial touchscreen + PLC-based logic controller with embedded Chinese OS |
| Environmental Exchange | Programmable fresh-air intake via energy-recovery heat exchanger |
| Safety & Compliance | Over-temperature cut-off, compressor suction pressure regulation (0–480 psig), PTC auxiliary heating, IoT-enabled remote monitoring and control (edge-computed, no client software required), real-time curve logging (365-day history), GLP-ready audit trail capability (timestamped parameter changes, user logins, alarm events) |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT600-BC / BAT800-BC |
| Temperature Range | 5–45 °C (0–400 μmol/m²/s PAR, adjustable) |
| Temperature Uniformity | ±0.5 °C (within horizontal plane) |
| Capacity | 600 L / 800 L |
| Illumination System | Top-mounted, independently controllable per shelf |
| Shaking Platform | 0–200 rpm, Φ26 mm amplitude, spring-clamp or adhesive plate mounting |
| Air Sampling | 3-channel adjustable-flow sampling pump |
| Control System | BAT200PG OS, 7″ color touchscreen, 24-segment programmable cycle with real-time clock |
| Cooling Technology | Hot-gas bypass refrigeration |
| Defrost Method | Solenoid-valve controlled, frost-free operation |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutout, overload protection |
| Data Logging | Internal storage ≥5 years |
| User Access Levels | 4-tier password management (Factory Admin, User Admin, Operator, Engineer) |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT600-TC / BAT800-TC / BAT1250-TC / BAT1700-TC |
| Capacity | 600 L / 800 L / 1250 L / 1700 L |
| Temperature Range | 5–45 °C (±0.2 °C fluctuation, ±0.5 °C uniformity) |
| Illumination | 0–300 μmol/m²/s (top-mounted, monochromatic LED, per-layer independent control) |
| Total Cultivation Area | 1.54 m² / 2.34 m² / 3.3 m² / 4.5 m² |
| External Dimensions | 850×805×1900 mm (BAT600-TC) to 1855×868×2030 mm (BAT1700-TC) |
| Control System | BAT200PG 7-inch color touchscreen controller with 24-segment programmable logic, APID temperature regulation, and 5-year onboard data logging |
| Brand | Boante |
|---|---|
| Model | BAT64-FS |
| Layers | 6 |
| Columns | 4 |
| Dimensions (L×W×H) | 560 × 140 × 348 mm |
| Compatible Cryobox Size | 133 × 133 × 54 mm |
| Paper Cryobox Capacity (81-well) | 24 per layer |
| Plastic Cryobox Capacity (100-well) | 24 per layer |
| Material | 0.6–1.0 mm Stainless Steel (AISI 304 grade equivalent) |
| Construction | Panel-stamped frame with precision resistance spot welding |
| Drawer Mechanism | Independent slide-out drawers with integrated cryobox retainer lips and access cutouts |
| Label Slot | Dedicated front-facing label holder per drawer |
| Customization | Available for non-standard cryobox dimensions (lead time ~15 working days) |
| Warranty | 12-month limited warranty covering manufacturing defects under normal ULT operation (−80 °C) |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BAT70-GSH |
| Cooling Method | Compressor-based cooling |
| Temperature Range | 4–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Fluctuation | ±0.2 °C |
| Temperature Uniformity | ±0.5 °C (within same shelf plane) |
| Capacity Options | 70 L / 150 L / 250 L / 360 L / 600 L |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT80SH-2 / BAT150SH-2 / BAT250SH-2 / BAT520SH-2 |
| Air Circulation | Forced convection |
| Temperature Range | 4°C to 60°C |
| Temperature Accuracy | ±0.1°C |
| Temperature Uniformity | ±0.8°C (within same shelf plane) |
| Temperature Fluctuation | ±0.5°C |
| Capacity Options | 80 L / 150 L / 250 L / 520 L (modular multi-zone configuration) |
| External Dimensions | 895×590×1590 mm (BAT80SH-2) to 1150×870×1650 mm (BAT520SH-2) |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Custom-Engineered (Non-Standard) |
| Quotation | Upon Request |
| Temperature Range | 10–45°C (with lighting), 0–45°C (without lighting) |
| Temperature Uniformity | ±1.0°C (standard), ±2.0°C (extended range) |
| Humidity Range | 40–80% RH (with lighting), 40–85% RH (without lighting) |
| Humidity Uniformity | ±3–5% RH |
| Photosynthetic Photon Flux Density (PPFD) Options | 0–200, 0–600, 0–800, or 0–1200 µmol/m²/s (measured at 150 mm from source) |
| Fresh Air Exchange | ≥300 m³/h, ≥10 air changes/h |
| Chamber Volume & Dimensions | Fully Customizable |
| Insulation | Polyurethane sandwich panels (50/75/100 mm thick), A1-class fire-rated core, steel facing ≥0.426 mm, density ≥120 kg/m³ |
| Lighting Spectrum | Continuous 380–780 nm (including far-red), PAR-optimized LED array |
| Control Interface | Color TFT touchscreen PLC (5″–15.6″ options), embedded Boante-developed firmware on MOXA/Kunlun Tongtai platform |
| Data Logging | ≥5 years local storage, GLP-compliant timestamped records |
| Remote Access | 4G/Wi-Fi enabled IoT gateway with role-based user management (1 admin + ≥20 users), SMS/WeChat alerting |
| Safety Systems | Dual-stage temperature safety cutoff, high/low pressure compressor protection, earth leakage detection, overcurrent/overheat coil monitoring, UV sterilization lamp (≥90 µW/cm², timer-controlled) |
| Air Quality | ISO Class 7 (10,000-grade) cleanroom performance (static): ≤350,000 particles/m³ @ 0.5 µm |
| Brand | Boante |
|---|---|
| Model | IBS-1020LSS |
| Drive Type | DC motor drive |
| Speed Range | 0–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±0.1 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions | 1020 × 760 × 1400 mm |
| Internal Dimensions | 880 × 585 × 990 mm |
| Shelf Plate Size | 786 × 484 mm |
| Max Capacity (per shelf) | 250 mL × 40, 500 mL × 24, 1000 mL × 15, or 2000 mL × 11 |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 1500 W |
| Net Weight | 260 kg |
