| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BIO-CHP (for Mice and Rats) |
| Pricing | Upon Request |
| Temperature Range | −3 °C to +65 °C (at ambient 20–25 °C, 50% RH) |
| Temperature Accuracy | ±0.5 °C |
| Cooling Time (RT → 4 °C) | <10 min |
| Heating Time (4 °C → 65 °C) | ≤5 min |
| Control Options | Manual Interface or Footswitch |
| Real-Time Display | Animal Response Latency & Plate Temperature |
| Programmable Profiles | Software-Defined Ramp/Cycle Sequences |
| Base Plate Dimensions | 165 × 165 mm |
| Main Unit Dimensions | 305 × 280 × 158 mm |
| Weight | 6.65 kg |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BIO-DL32 |
| Pricing | Available Upon Request |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Model | ChemiDoc Gel Imaging System |
| Camera | Scientific-grade deep-cooled CCD (−60 °C typical operating temperature) |
| Lens | High-aperture f/0.95 lens |
| Light Sources | UV (254 nm & 365 nm), White LED, RGB Epi-Fluorescence (470/525/630 nm excitation), Near-Infrared (NIR, 740/850 nm) |
| Optional Accessories | Temperature-controlled sample stage (4–40 °C), Anesthesia module for in vivo imaging |
| Software | Modular acquisition & analysis suite with guided workflow, non-destructive image enhancement, batch processing, and audit-trail-enabled data management |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Model | Easywash |
| Display | 10-inch capacitive touchscreen (1280 × 800) |
| Wash Head Options | Interchangeable 8-channel or 12-channel single/dual-row heads |
| Aspiration/Dispense Speed | 9 adjustable levels |
| Data Storage | Internal 4 GB flash memory (≥20,000 protocol & run records) |
| Automation Interface | RS-232, USB Device/Host, optional Ethernet |
| Compliance Features | Liquid-level sensing, plate-position detection, leak detection, dual independent peristaltic pumps with pressure monitoring |
| Software | Embedded GUI with bilingual (English/Chinese) support, folder-based protocol organization, USB firmware update & data export capability |
| Residual Volume | ≤2 µL/well (96-well plate, standard wash cycle) |
| Compatibility | ANSI/SLAS-format microplates (96-, 384-well), PCR plates, deep-well plates |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GelDoc Pro |
| Pricing | Available Upon Request |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | K3 Plus Microplate Reader |
| Detection Method | Absorbance (Optical Density) |
| Function Type | Single-Mode Absorbance Reader |
| Wavelength Range | 400–750 nm |
| Absorbance Linearity | 0–3.0 A at 450 nm (r² ≥ 0.995) |
| Accuracy | ±0.007 Abs (0–0.3 A) |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Model | K3 Pro Microplate Reader |
| Detection Wavelength Range | 330–900 nm |
| Filter Capacity | Up to 8 interchangeable optical filters |
| Read Time (96-well plate) | 8 s (step mode) |
| Incubation Temperature Range | Room temperature +4 °C to 55 °C |
| Shaking Speed | 3 adjustable levels |
| Absorbance Range | 0–6.0 OD |
| Display | 10-inch capacitive touchscreen |
| Detection Modes | Single-wavelength, dual-wavelength, kinetic, endpoint, multi-wavelength, dual-time point |
| Connectivity | USB, Ethernet, Wi-Fi |
| Software | BIO-DL Microplate Analysis Suite (v3.2+) |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Life ECO |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well format (0.2 mL tubes or plates) |
| Max. Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.3 °C |
| Cooling Rate | ≥4 °C/s |
| Temperature Range | 4–105 °C |
| Thermal Control Modes | Block Mode & Simulated Tube Mode |
| Gradient Range | 1–30 °C |
| Heat Lid Temperature | Adjustable from 30–110 °C with pressure regulation |
| Display | 5.7-inch color touchscreen |
| Onboard Memory | 250 protocols |
| Interface | USB port for firmware/software updates and data export |
| Power Failure Recovery | Yes |
| Soak Function | Yes |
| Certifications | Ferrotec Peltier thermoelectric modules |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NAD Fully Automated Nucleic Acid Extraction Workstation |
| Pricing | Available Upon Request |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | JTS-150 |
| Excitation & Detection Wavelength Range | 320–1120 nm |
| Detector | Si PIN Photodiode |
| Optical Density (OD) Sensitivity | 1×10⁻⁵ OD (OD 0–2 range) |
| Time Resolution | 10 µs to minutes |
| Optional Flash Sources | Laser or Xenon Flash Lamp |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BIO-PP-4 |
| Pricing | Available Upon Request |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex 200 |
| Configuration | Complete system with dual-laser detection, magnetic bead handling, and integrated fluidics |
| Detection Principle | xMAP® (x-MAP) technology based on fluorescently encoded microspheres |
| Multiplex Capacity | Up to 500 analytes per well |
| Sample Format | 96-well or 384-well microplate |
| Detection Lasers | 532 nm (reporter) and 635 nm (classification) |
| Sensitivity | Sub-picogram/mL range for cytokines (typical) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex 200 (with HTF) |
| Regulatory Classification | Imported Instrument for In Vitro Diagnostic Use |
| Platform Technology | xMAP® Luminex-based Bead-Based Suspension Array |
| Detection Method | Dual-Laser Flow Cytometric Analysis (532 nm excitation / 635 nm classification + 532 nm excitation / 585 nm emission) |
| Sample Format | 96-well or 384-well microplate |
| Multiplex Capacity | Up to 500-plex per well |
| Sensitivity | Sub-picogram/mL range (varies by analyte and assay configuration) |
| Dynamic Range | ≥3–4 logs |
| Throughput | Up to 96 samples per run (standard plate) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Bio-Plex 3D |
| Pricing | Available Upon Request |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex Pro |
| Instrument Type | Dedicated Microplate Washer |
| Wash Head Configuration | 8-channel |
| Rinse Needle Design | Single-needle per channel |
| Wash Fluid Channels | 8 independent wash fluid channels |
| Waste Aspiration Channels | 8 independent waste aspiration channels |
| Soak Time | Programmable, dynamic control |
| Wash Cycles | Programmable, dynamic control |
| Residual Volume per Well | <4 µL |
| Orbital Shaking Function | Yes |
| Plate Carrier | Integrated magnetic plate carrier for xMAP®-based assays (including MagPlex®) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex Protein Array System |
| Excitation Lasers | 532 nm & 635 nm |
| Sensitivity | <10 pg/mL |
| Inter- and Intra-Assay CV | <10% |
| Dynamic Range | 1–32,000 pg/mL |
| Recovery Rate | Serum 80–120%, Cultured Cells 90–110% |
| Throughput | 96 samples in 30 minutes (up to 9,600 data points) |
| Sample Volume | 12 µL per well |
| Plate Format | Standard 96-well microplate |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ 384-Well |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 384-well plate |
| Max Heating Rate | 2.5 °C/s |
| Temperature Accuracy | ±0.2 °C at 90 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 s at 90 °C |
| Temperature Gradient Range | 1–24 °C across 12 columns |
| Gradient Accuracy | ±0.2 °C (last column) |
| Operating Temperature Range | 0–100 °C |
| Input Power | 850 W max |
| Display | 8.5-inch color LCD touchscreen |
| Onboard Memory | >1,000 protocols |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ 96 Deep Well |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 1–96 wells (0.2 mL tubes or 96-well plates) |
| Max Heating Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Heating/Cooling Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 sec at 90°C |
| Temperature Gradient Range | 30–100°C |
| Gradient Accuracy (last column) | ±0.2°C |
| Column-wise Uniformity | ±0.4°C within 10 sec at 90°C |
| Input Power | 850 W max |
| Display | 8.5" color LCD touchscreen |
| Onboard Memory | >1,000 protocols |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ Dual 48 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 2 × 48 × 0.2 mL tubes or 2 × 48-well plates |
| Max Heating Rate | 4°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Temperature Gradient Range | 1–24°C (30–100°C) |
| Gradient Accuracy | ±0.2°C (last column) |
| Gradient Uniformity per Column | ±0.4°C within 10 s |
| Input Power | 850 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX Connect |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well (0.2 mL tubes) |
| Maximum Heating Rate | 5 °C/s (adjustable from 0.1 to 5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Sources | 3 LEDs (450–535 nm) |
| Emission Detection Range | 3 Photodiodes (515–580 nm) |
| Gradient PCR | Yes, range 30–100 °C, max ΔT = 24 °C |
| High-Resolution Melting (HRM) Support | Yes |
| Connectivity | USB |
| Dimensions (W×D×H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Duet |
| Detection Channels | 2 + FRET |
| Temperature Uniformity | ±0.3°C across 96-well block |
| Gradient Range | Up to 24°C |
| Software | CFX Maestro (including FDA 21 CFR Part 11-compliant Security Edition) |
| Included License | qbase+ Advanced Analysis Module |
| Optical System | Solid-State Scanning Optical Shuttle |
| Calibration | Factory-calibrated for common dyes (FAM, HEX, VIC, ROX, Cy5, etc.) |
| Compatibility | Full compatibility with Bio-Rad PrimePCR Assays and SsoAdvanced Supermixes |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus 384 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 384-well format |
| Heating Rate | 2.5 °C/sec |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.3 °C |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus 96 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.3°C |
| Optical Configuration | Individual well excitation and detection with FRET-capable channels |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus Deepwell |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 2.5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX384 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 384-well format |
| Maximum Heating Rate | 2.5 °C/s (adjustable from 0.1 to 2.5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 5 LEDs (400–650 nm) |
| Emission Detection Range | 5 Photodiodes (515–690 nm) |
| Supported Applications | Absolute Quantification, Gene Expression Analysis, SNP Genotyping, HRM (High-Resolution Melting), Multiplex Detection (up to 4 targets per well) |
| Software | CFX Maestro Secure Edition (21 CFR Part 11 compliant, audit trail, user access control) |
| Thermal Block | Integrated C1000 Touch thermal cycler engine |
| Gradient PCR | Yes, 30–100 °C range, max ΔT = 24 °C |
| Dimensions (W × D × H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg (47 lb) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX96 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well (0.2 mL tubes) |
| Max Heating Rate | 5 °C/s (adjustable from 0.1 to 5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 6 LEDs (450–684 nm) |
| Emission Detection Range | 6 Photodiodes (515–730 nm) |
| Gradient PCR | Yes, 30–100 °C, max ΔT = 24 °C |
| High-Resolution Melting (HRM) Support | Yes |
| Interface | USB |
| Dimensions (W×D×H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFX96 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well |
| Heating Rate | 3.3°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ChemiDoc Go |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 20 MP (physical pixels) |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Fixed-focus f/0.95 lens |
| Excitation Sources | Transmitted UV (302 nm), Transmitted Blue Light (470 nm, optional), Transmitted White Light (optional), Reflected UV (365 nm), Reflected Green Light (530 nm) |
| Emission Filters | 520/26 nm BP, 590/110 nm BP, 695 nm LP |
| Dual-Channel Fluorescence | StarBright 520 nm & 700 nm channels |
| Regulatory Status | For research use only (RUO), not for clinical diagnostic use |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | ChemiDoc |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6.1 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 1-inch |
| Detection Sensitivity | fg-level protein |
| Signal-to-Noise Ratio | >56 dB |
| Lens | Fixed-focus |