Life Science Instruments
Filter
Showing 631–660 of 7216 results
| Brand | Beckman Coulter |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | CytoFLEX o |
| Technology Platform | Nanoscale Flow Cytometry |
| Instrument Type | Flow Cytometer |
| Primary Use Case | Research |
| Lasers | 405 nm, 488 nm, 561 nm, 638 nm |
| Fluorescence Detection Channels | 6 |
| Side Scatter (SSC) Detection Channels | 5 |
| Particle Size Detection Range | 40 nm – 1 µm |
| Automated Sample Loading | Yes |
| Compensation Method | Fully Automated |
| Sorting Capability | Optional |
| Sorting Output Ports | 6-way |
| Voltage Adjustment Required | No |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CytoFLEX S Series |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Primary Use Case | Research |
| Laser Configuration | Up to four spatially separated lasers (375 nm, 405 nm, 488 nm, 561 nm) |
| Fluorescence Detection Channels | Up to 13 parameters with full-channel rCV < 3% |
| Optical Resolution | Side Scatter (488 nm) < 300 nm, Violet Side Scatter (405 nm) < 80 nm (vs. polystyrene beads) |
| Sample Flow Rate | 10–240 µL/min (user-selectable in 10/30/60 µL/min presets or fully adjustable) |
| Fluorescence Sensitivity | ≤30 MESF (FITC), ≤10 MESF (PE) at 15-parameter configuration |
| Event Acquisition Rate | Up to 30,000 events/sec (continuous, software-adjustable) |
| Automated Sample Loading | Integrated plate-based autosampler optional |
| Compensation Method | Real-time automatic compensation with saved compensation matrices |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Sorting Flow Cytometer |
| Application Domain | Research |
| Laser Configuration | Up to 4 Lasers (405 nm, 488 nm, 561 nm, 638 nm) |
| Fluorescence Detection Channels | 15 Total (Configurable BPF Filters) |
| Optical Precision | rCV < 3% across all channels |
| Side Scatter Resolution | < 300 nm (488 nm excitation), < 200 nm (405 nm excitation) |
| Sample Flow Rate | 10–100 µL/min |
| FITC Sensitivity (488 nm) | < 30 MESF |
| Cell Acquisition Rate | 40,000 events/sec |
| Sorting Throughput | 30,000 cells/sec |
| Nozzle Diameter | 100 µm |
| Droplet Frequency | 35 kHz |
| Sorting Logic | Quadruple-Stream Sorting with Mixed-Mode and Discard-Capture Capability |
| Compensation | Fully Automated Real-Time Compensation |
| Sample Loading | Integrated Auto-Sampler (40,000 events/sec loading speed) |
| Voltage Adjustment Required | No |
| Biosafety Options | Optional Aerosol Containment Cabinet or Standalone Aerosol Exhaust System |
| Software Platform | CytExpert for CytoFLEX SRT (FDA 21 CFR Part 11–Ready Audit Trail, GLP/GMP-Compliant Data Integrity Features) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Cytomics FC500 |
| Product Type | Flow Cytometry Analyzer |
| Laser Configuration | Single or dual collinear lasers |
| Fluorescence Channels | 5-color detection |
| Sample Formats | 12×75 mm tubes, 24-/48-/96-well microplates, Eppendorf tubes |
| Software | CXP Data Acquisition and Analysis Software |
| Compliance | Designed for GLP-compliant research environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic IVD Instrument |
| Model | DxFLEX |
| Product Category | Clinical Flow Cytometry System |
| Application Domain | In Vitro Diagnostic (IVD) Laboratories |
| Laser Configuration | 3 Lasers / 13 Fluorescence Parameters |
| Fluorescence Sensitivity | ≤30,000 Equivalent Stained Particles (ESPs) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | EPICS XL / XL-MCL |
| Product Type | Flow Cytometry Analyzer |
| Regulatory Classification | Imported Instrument |
| Software Platform | System II™ |
| Detection Capability | 4-color fluorescence, multi-parameter analysis |
| Sample Throughput (XL-MCL) | Up to 100 samples/hour |
| Fluidics Architecture | Closed-system design with pre-aspirational mixing and barcode-enabled tri-channel positive sample identification |
| Optical Configuration | Interchangeable filter sets for flexible assay configuration |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Gallios |
| Product Type | Flow Cytometry Analyzer |
| Category | Cell Analysis Instrument |
| Import Status | Imported |
| Distribution Model | Authorized Distributor |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | MoFlo XDP |
| Product Category | High-Performance Flow Cytometry-Based Cell Sorting System |
| Sample Size Range | 0.5–50 µm |
| Maximum Analysis Rate | >100,000 cells/sec |
| Maximum Sorting Rate | >70,000 cells/sec |
| Fluorescence Parameters | Up to 18 colors + 2 scatter channels (with multi-laser configuration) |
| Sorting Output | 4-way simultaneous sorting |
| Nozzle Options | 8 interchangeable nozzles (50–200 µm) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Navios EX |
| Technology Platform | Spectral Flow Cytometry |
| Instrument Type | Clinical-Grade Flow Cytometer |
| Laser Configuration | Up to 3 Lasers |
| Detection Channels | 12 |
| Forward Scatter (FSC) Collection Modes | Wide (1–18°), Narrow (1–8°), Wide Enhanced (optimized for submicron particles) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Navios |
| Product Category | Flow Cytometry Analyzer |
| Intended Use | Clinical Diagnostics |
| Lasers | 405 nm (violet), 488 nm (blue), 638 nm (red) |
| Detection Channels | Up to 10-color capability |
| Fluorescence Sensitivity | <112 MESF (FITC), <78 MESF (PE), <15 MESF (PC5) |
| Forward & Side Scatter Detection | Photodiode-based FSC/SSC |
| Fluorescence Detection | Photomultiplier Tube (PMT)-based |
| Optical System | Solid-state diode lasers with integrated flow cell |
| Flow Cell Dimensions | 150 µm × 460 µm rectangular quartz cuvette |
| Temperature Control | Integrated thermal regulation for optical path stability |
| Data Processing | Real-time digital signal processing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Regulatory Certification | China NMPA Import Registration No. 20172401770 |
| Compliance | Designed for CLIA- and CAP-aligned clinical laboratories |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Imported Instrument |
| Model | OPTIMA AUC |
| Detection Range | 5 µg/mL – 150 mg/mL |
| Sample Volume | 380 µL |
| Analysis Duration | Hours (typically 2–8 h per run) |
| Temperature Control Range | 0–40 °C |
| Detection Modes | UV-Vis Absorbance (190–800 nm) and Interference Optics |
| Simultaneous Wavelengths | Up to 20 |
| Maximum Rotor Capacity | 8 cells (An-50 Ti rotor) |
| Throughput | Up to 7 samples per run (standard configuration), up to 21 sample conditions via sequential or multi-temperature protocols |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vi-CELL BLU |
| Assay Time | Fast Mode 80 s/sample, Standard Mode 110 s/sample |
| Cell Concentration Range | 2 × 10⁴ to 1.5 × 10⁷ cells/mL |
| Sample Volume | Fast Mode 170 µL, Standard Mode 200 µL |
| Throughput | 96 samples per run |
| Detectable Cell Size | 2–60 µm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Vi-CELL MetaFLEX |
| Pricing | Available Upon Request |
| Brand | Beckman Coulter |
|---|---|
| Model | Vi-CELL XR |
| Origin | USA |
| Product Type | Automated Cell Viability and Counting System |
| Sample Volume Range | 0.5–100 µL |
| Cell Size Detection Range | 2–700 µm |
| Imaging Sensor | 1394 × 1040 CCD array |
| Interface | IEEE 1394 (FireWire) |
| Focus Mechanism | Motorized Auto-Focus |
| Reagent Kits Available | Vi-CELL XR Quad Pack, Vi-CELL AS/S Quad Pack |
| Calibration Standards | Vi-CELL Concentration Control, Vi-CELL Focus Control |
| Data Export Format | Native Excel (.xlsx), CSV, TIFF image archives |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model Numbers | S16001-10, S16002-10, S16003-11, S16004-11 |
| Pricing | Available Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DZD-16 |
| Instrument Type | Inversion Shaker |
| Timer Range | 1 s – 99 h 99 min |
| Oscillation Frequency | Up to 300 cycles/min |
| Inversion Angle | 360° continuous rotation |
| Temperature Control | Ambient only |
| Tray Capacity | 16 sample positions |
| Sample Volumes | 250 mL × 8 or 500 mL × 8 |
| Rotation Direction | Bidirectional (forward/reverse) |
| Speed Control | 0–200 rpm adjustable |
| Extraction Efficiency | >95% |
| Safety Design | Sealed extraction vessels, fume containment, ventilator-compatible footprint |
| Brand | Beifen Sanpu |
|---|---|
| Model | SK-1 |
| Type | Vortex Mixer |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 40 W |
| Operating Mode | Orbital (Circular) Motion |
| Oscillation Frequency | 3000 rpm |
| Amplitude | 5 mm |
| Timer Range | 5–120 s |
| Tray Configuration | Single Platform |
| Sample Holder Compatibility | Test Tubes, Colorimetric Tubes, Small Erlenmeyer Flasks (≤100 mL) |
| Origin | Hebei, China |
| Manufacturer Status | Direct Manufacturer |
| Regulatory Classification | Domestic Instrument for Academic & General Laboratory Use |
| Price Range | USD 140–700 (FOB) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Orbital Water Bath Incubator Shaker |
| Timer Range | 5–120 min |
| Oscillation Frequency | 0–300 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.5 °C |
| Heating Power | 1880 W |
| Tray Dimensions | 39 × 29 cm |
| Overall Dimensions | 700 × 550 × 480 mm |
| Power Supply | AC 220 V, 50 Hz |
| Chamber Material | Stainless Steel (304) |
| Drive Mechanism | Belt-driven orbital motion with mechanical speed regulation |
| Timer Function | Mechanical dial timer with “continuous” position |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water Bath Incubator Shaker |
| Model | THZ-82(A) |
| Timing Range | 0–120 min |
| Oscillation Frequency | Adjustable, 0–300 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.5 °C |
| Oscillation Mode | Orbital (standard for THZ-82 series) |
| Tray Quantity | 1 |
| Power Supply | 220 V, 50 Hz |
| Heating Power | 1800 W |
| Water Bath Chamber Dimensions | 490 × 390 × 170 mm (L×W×H) |
| Overall Dimensions | 700 × 550 × 490 mm (L×W×H) |
| Construction | Stainless Steel Interior |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TY-80A/TS-80 |
| Instrument Type | Orbital Shaker |
| Timer Range | 0–120 min |
| Oscillation Frequency | 0–80 rpm (infinitely adjustable) |
| Oscillation Amplitude | 10 mm |
| Platform Dimensions | 280 × 220 mm |
| Operating Mode | Continuous |
| Power Consumption | 20 W |
| Voltage/Frequency | 220 V, 50 Hz |
| Platform Quantity | 1 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | WHY-2A |
| Instrument Type | Refrigerated Water Bath Orbital Shaker |
| Timer Range | 0–120 min |
| Oscillation Frequency | 0–300 rpm (adjustable) |
| Oscillation Amplitude | 20 mm |
| Temperature Control Range | 0–100 °C (with active refrigeration) |
| Platform Quantity | 1 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ZD-85A |
| Instrument Type | Water Bath Constant-Temperature Shaker / Orbital Shaker |
| Timer Range | 5–120 min |
| Oscillation Frequency | 80–220 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Control Range | Ambient to 50 °C |
| Temperature Uniformity | ±1 °C |
| Tray Quantity | 1 |
| Operating Mode | Reciprocating Motion |
| Chamber Material | Stainless Steel (304) |
| Oxygenation Ports | Yes |
| Speed Control | Stepless (Analog or Potentiometer-Based) |
| Compliance | Designed for GLP-supporting laboratory environments |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZW-B |
| Instrument Type | Water-Bath Constant-Temperature Shaker / Orbital Shaker |
| Timer Range | 0–120 min |
| Oscillation Frequency | 3000 rpm |
| Oscillation Amplitude | 6 mm |
| Temperature Control Range | 0–100 °C (with active cooling) |
| Platform Quantity | 1 |
| Power Supply | 220 V, 50 Hz |
| Dimensions (W×D×H) | 260 × 250 × 160 mm |
| Capacity | 1–20 vials per cycle |
| Safety | Grounded 3-pin plug required |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZW-B |
| Price Range | USD 700–1,400 |
| Instrument Type | Ambient-to-High-Temperature Orbital Shaker |
| Timer Range | 5–120 minutes |
| Oscillation Frequency | 3000 cycles/min |
| Oscillation Amplitude | 6 mm |
| Temperature Control Range | Ambient to 95 °C |
| Platform Quantity | 1 |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-31A |
| Instrument Type | Nucleic Acid Electrophoresis Apparatus |
| Gel Tray Dimensions (L × W) | 85 × 80 mm |
| Sample Combs | 12- and 15-well, 1.0 mm and 2.0 mm thickness |
| External Dimensions (L × W × H) | 242 × 132 × 105 mm |
| Buffer Capacity | 500 mL |
| Weight | 1 kg |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Nucleic Acid Electrophoresis Apparatus |
| Gel Tray Dimensions (L × W) | 60 × 60 mm |
| Sample Combs | 6-well & 8-well (1.5 mm thickness), 11-well (1.0 mm & 1.5 mm thickness) |
| Overall Dimensions (L × W × H) | 197 × 96 × 100 mm |
| Buffer Capacity | 120 mL |
| Weight | 0.5 kg |
| Brand | Beijing Liuyi/LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | General Distributor |
| Product Category | Domestic |
| Model | DYCP-31C |
| Instrument Type | Horizontal Electrophoresis Tank |
| Gel Tray Dimensions (L×W) | 110 × 65 mm |
| Sample Combs | 9-well and 14-well configurations |
| External Dimensions (L×W×H) | 180 × 95 × 75 mm |
| Buffer Capacity | ~255 mL |
| Weight | ~1 kg |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-32A |
| Instrument Type | Nucleic Acid Electrophoresis Apparatus |
| Gel Tray Dimensions (L × W) | 160 × 100 mm |
| Overall Dimensions (L × W × H) | 300 × 162 × 110 mm |
| Buffer Capacity | 650 mL |
| Weight | 2 kg |
| Comb Options | 12-, 16-, and 22-well combs |
| Compliance | Designed for standard molecular biology laboratory workflows under GLP-aligned practices |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-32C |
| Instrument Type | Nucleic Acid Electrophoresis Apparatus |
| Gel Tray Dimensions (L×W) | 250×250 mm, 120×250 mm, 60×250 mm |
| Overall Dimensions (L×W×H) | 420×300×90 mm |
| Buffer Capacity | 1600 mL |
| Weight | 2.5 kg |
| Sample Comb Options | 51-, 42-, and 26-well combs, available in 1.0 mm and 2.0 mm thicknesses |
| Safety Feature | Lid-activated power cutoff |
| Construction Material | Polycarbonate body |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-40C |
| Instrument Type | Semi-Dry Electrophoretic Transfer System |
| Gel/Transfer Plate Dimensions | 150 × 150 mm |
| External Dimensions (L×W×H) | 210 × 186 × 100 mm |
| Weight | 3 kg |
| Electrode Material | Conductive Carbon Plates |
| Insulation | Integrated Non-Conductive Spacer Gaskets |
| Buffer Requirement | Minimal-volume buffer system (no bulk tank required) |
