| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | HCFM-XP Gen3 |
| Measurement Diameter Range | 1–36 mm |
| Flow Rate Range | 0.01–350 g/h (5 selectable ranges) |
| Hydraulic Conductance Range | 7.7×10⁻⁸ to 3.5×10⁻⁴ kg·s⁻¹·MPa⁻¹ |
| Pressure Output Resolution | 0.1 kPa |
| Max Operating Pressure | 620 kPa |
| Deaerated Water Reservoir Capacity | 0.7 L |
| Compressed Gas Cylinder Capacity | 170 L (at STP), CGA-580 valve |
| Data Acquisition | 1 reading per 2 s |
| A/D Conversion | 24-bit dual analog/digital |
| Dimensions (L×W×H) | 61×48×23 cm |
| Weight | 15 kg |
| Power & Interface | USB-powered, integrated data logging |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SGDC |
| Type | Heat Balance-Based Stem Flow Sensor |
| Compliance | Validated per USDA-ARS protocols (Lascano et al., 2016, *Agric. Sci.*) |
| Channel Requirement | 2 differential analog inputs (temperature + heater voltage/current) |
| Stem Diameter Range | 7–25 mm (model-dependent) |
| Enclosure Design | EXO-Skin conformal wrap |
| Heater Architecture | Molded, low-thermal-mass resistive element |
| Environmental Protection | IP67-rated moisture barrier |
| Calibration Traceability | NIST-traceable thermistor and voltage references |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DynaCell190i |
| Price Range | USD 7,800–10,000 (FOB) |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +5°C to 50°C, ±0.1°C (at setpoint) |
| Temperature Uniformity | ±0.3°C at 37°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol., ±0.1% (full scale) |
| Humidity Control Range & Accuracy | 20–95% RH, ±3% RH (measured at 37°C, 5% CO₂) |
| Chamber Capacity | 190 L |
| External Dimensions (W×D×H) | 720 × 694.5 × 890 mm |
| Standard Configuration | Dual-stage HEPA filtration (0.3 µm, ≥99.97% efficiency), Dual sterilization protocol (180°C dry-heat bake-out, 90°C moist-heat cycle) |
| Brand | Dynamica |
|---|---|
| Model | EHS-530 |
| Cabinet Class | Class II, Type A2 |
| Construction Material | 304 Stainless Steel Interior (One-Piece Seamless Welded) |
| External Dimensions (L×W×H) | 1950 × 750 × 2100 mm |
| Internal Work Area Dimensions (L×W×H) | 1862 × 574 × 628 mm |
| HEPA/ULPA Filtration Efficiency | ≥99.9995% @ 0.12 µm |
| Airflow System | Recirculating (70% re-circulated, 30% exhausted via dedicated duct or thimble connection) |
| Motor Type | Brushless DC ECM Motor with Variable Speed Control |
| Control Interface | DynaAir Color Touchscreen Controller with Real-Time Airflow Monitoring |
| Sensor | High-Sensitivity Thermal Anemometer for Inflow & Downflow Velocity Detection |
| Compliance | EN 12469:2000, NSF/ANSI 49-2022, ISO 14644-1 Class 5 (ISO Class 5 Equivalent), GLP-Ready Configuration |
| Brand | Dynamica |
|---|---|
| Model | HALO MPR-96 |
| Origin | Switzerland |
| Wavelength Range | 400–750 nm (MPR-96UV: 340–750 nm) |
| Absorbance Range | 0–4.0 OD |
| Resolution | 0.001 OD |
| Stability | ±0.001 OD (after 15 min warm-up) |
| Accuracy | ±1.0% ±0.01 OD (405 nm, 0.000–2.500 OD) |
| Repeatability | ±0.5% ±0.005 OD (405 nm, 0.000–2.500 OD) |
| Linearity | ±1.0% (405 nm, 0.000–2.500 OD) |
| Filter Positions | 5 (4 fixed + 1 user-selectable, 400–750 nm) |
| Read Time | ≤10 s (single wavelength, 96-well) |
| Plate Formats | 96-well flat, U-bottom, V-bottom |
| Optical Channels | 8 measurement + 1 reference |
| Detector | Silicon photodiode |
| Light Source | Tungsten-halogen lamp |
| Display | Backlit LCD, 320×240 px |
| Incubation (optional) | Ambient +4°C to +50°C, ±0.5°C accuracy |
| Dimensions (W×D×H) | 290×425×200 mm |
| Weight | 15 kg (net), 20 kg (gross) |
| Power | 110–220 V auto-switching, 50/60 Hz, 50 W (standby), 100 W (operational) |
| Brand | Dynamica |
|---|---|
| Model | NU-437-400S / NU-437-600S |
| Type | Class II A2 Biological Safety Cabinet |
| External Dimensions (W×D×H) | 1972 × 835 × 1600 mm (NU-437-600S) / 1362 × 835 × 1600 mm (NU-437-400S) |
| Internal Work Area (W×D×H) | 1788 × 597 × 724 mm (NU-437-600S) / 1178 × 597 × 724 mm (NU-437-400S) |
| Inflow Velocity | 0.53 m/s |
| Downflow Velocity | 0.30 m/s |
| HEPA Filtration Efficiency | ≥99.999% for particles 0.1–0.3 µm (H14 grade) |
| Airflow Configuration | 30% exhaust, 70% recirculation |
| Construction | 16-gauge 304 stainless steel, fully welded double-wall chamber |
| Pressure Integrity | Withstands 500 Pa static pressure test |
| Compliance | YY 0569–2011 (China), aligned with NSF/ANSI 49 and EN 12469 principles |
| Brand | Ebaiao |
|---|---|
| Origin | Hunan, China |
| Manufacturer | Yes |
| Instrument Type | Benchtop |
| Function Modules | Automatic Tube Cap Opening |
| Sample Throughput | ≥96 tubes per run |
| Sample Type | Whole Blood, Plasma, Buffy Coat, RBC |
| Pipetting Range | 1–1000 µL |
| Pipetting Speed | 1–3 seconds per transfer |
| Pipetting Accuracy | CV ≤5.0% at 2 µL (using 10-µL tips), CV ≤3.0% at 10 µL, CV ≤0.5% at >50 µL |
| Brand | Ebaiao |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ZHT200 |
| Sample Throughput | 4 × 96-well plates per run |
| Integrated Centrifuge Options | ZD-1 (4000 rpm / 3000 × g), ZD-2 (5500 rpm / 5010 × g) |
| Pipetting Accuracy | ±0.03 mm repeatability (Z-axis), ±0.1° centrifuge basket positioning |
| Sealing Temperature Range | 120–200 °C |
| Sealing Time | 1–10 s |
| Sealing Height Adjustment | 3–60 mm |
| Robotic Arm | 4-axis, R-axis rotation ±1080°, Axis 1 arm length 220 mm (±90°), Axis 2 arm length 200 mm (±164°), Z-axis travel 180 mm |
| Compatible Tip Formats | 96- and 384-channel disposable tips |
| Air Compressor | Integrated |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | DianJiang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ECA-YLS01 |
| Price Range | USD 7,000 – 14,000 |
| Light Source | 470 nm Blue LED |
| Photosynthetic Photon Flux Density (PPFD) | 0–5000 μmol·m⁻²·s⁻¹ (adjustable) |
| Minimum Sampling Interval | 2 μs |
| Data Acquisition Rate | Up to 500,000 points per second |
| Onboard Storage | 4 GB microSD card |
| Interface | USB 2.0 |
| Display | 128 × 64 monochrome LCD |
| Power Supply | Rechargeable Li-ion battery (7.6 V, 2.6 Ah) |
| Weight | 400 g |
| Dimensions | 12.5 × 8.0 × 3.3 cm |
| Dark Adaptation Clip | Integrated, leaf-compatible design |
| Brand | ECHO |
|---|---|
| Origin | Beijing, China |
| Configuration | Upright & Inverted Combined Platform |
| Standard Objective | Fluorite (FL) Objectives |
| Optional Objective | Apochromatic (APO) Objectives |
| Imaging Modes | Brightfield, Phase Contrast, Fluorescence, Polarization |
| Automation | Motorized Z-focus, XY-stage, Filter Cube Turret, Illumination Intensity Control |
| User Interface | Integrated Touchscreen Display with Mouse/Joystick Support |
| Power & Control Architecture | Fully Embedded Controller, Internal Cabling, No External Boxes |
| Optical Performance | High-NA FL/APO Objectives, Optimized for Live-Cell & Fixed-Sample Imaging |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Software Features | Real-time Z-stack acquisition, Multi-point time-lapse scheduling, Multi-channel spectral registration, Tile-scan mosaic stitching, Autofocus (contrast-based & hardware-assisted), Export formats: TIFF, OME-TIFF, JPEG2000 |
| Brand | ECHO |
|---|---|
| Origin | USA |
| Model | RVL-100-G |
| Configuration | Upright/Inverted Convertible Microscope |
| Optical Modes | Brightfield, Darkfield, Phase Contrast, Fluorescence, Polarization |
| Display | 12.9-inch Retina Touchscreen (iPad Pro-based) |
| Objective Compatibility | Olympus® 1.25x–100x achromat, fluorite, and apochromat objectives |
| Condenser | Long-working-distance & high-resolution condensers |
| Fluorescence Illumination | 5-channel high-intensity LED system (50,000 hr lifetime) |
| Cameras | Dual-sensor imaging — 12 MP color CMOS (BF), 5 MP monochrome sCMOS (FL) |
| Digital Image Processing | Real-time GPU-accelerated Digital Haze Reduction (DHR) |
| Brand | ECHO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SDC |
| Configuration | Upright/Inverted Integrated Platform |
| Imaging Modality | Spinning Disk Confocal, Widefield Fluorescence, Super-Resolution (SIM-based) |
| Brand | Ecomatik |
|---|---|
| Origin | Germany |
| Model | DF1 / DF2 / DF3 |
| Measurement Principle | High-Resolution Linear Displacement Transduction via Spring-Loaded Contact Probe |
| Sensor Range | 15 mm (DF1), 25.4 mm (DF2), 50.8 mm (DF3) |
| Full-Scale Diameter Monitoring Range | 0–110 mm (expandable) |
| Accuracy | ±2 µm (DF1), ±3.3 µm (DF2), ±6.6 µm (with CR1000 Logger) |
| Resolution | 0.04% of reading + 6–20 µm (logger-dependent) |
| Temperature Coefficient | <0.2 µm/°C |
| Operating Temperature | −25 to +70 °C |
| Relative Humidity | 0–100% RH |
| Weight | 15 g (DF1), 26 g (DF2), 37 g (DF3) |
| Power | Internal battery, >2 years continuous logging (with DL10 datalogger) |
| Data Storage | Up to 1,900,000 records (4 sensors, 1-min interval, 1-year capacity) |
| Interface | Analog voltage output (0–2.5 V or 0–5 V), compatible with Campbell Scientific CR1000/CR6, Delta-T Devices GP2, DataTaker DT80/DT85, and other standard analog-input loggers |
| IP Rating | IP67 (fully weatherproof) |
| Brand | Ecomatik |
|---|---|
| Origin | Germany |
| Model | SF-G |
| Measurement Principle | Granier Thermal Dissipation Method |
| Probe Configuration | Dual-needle, Constant Current Heating |
| Output Signal | 0–1000 µV differential voltage |
| Power Consumption | 0.2 W ±5% (84 mA @ 12 VDC) |
| Operating Temperature | –25 to +50 °C |
| Cable Length | Standard 5 m (extendable to 20 m) |
| Suitable Stem Diameter | >5 cm |
| Probe Variants | SF-G33 (33 mm needle / 20 mm heater), SF-G43 (43 mm / 20 mm), SF-G63 (63 mm / 20 mm) |
| Compliance | Compatible with ISO 17025-accredited data acquisition systems and GLP/GMP environmental monitoring workflows |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HT-Respiro 24/96/240 Series |
| Pricing | Available Upon Request |
| Oxygen Measurement Range | 0–50% O₂ or 0–22.5 mg/L |
| Detection Limit | 0.15% O₂ (15 ppb DO) |
| Accuracy | ±1% at 20.9% O₂ |
| Resolution | ±0.4% at 20.9% O₂ or ±5 µmol at 283.1 µmol |
| Response Time | <30 s |
| Drift | <1% air saturation per week (10-min sampling interval) |
| Channel Capacity | Up to 240 parallel channels (10 × 24-channel readers) |
| Sensor Technology | Fluorescence-based optical oxygen sensing (REDFLASH for 96-well format) |
| Sample Chamber Material | Borosilicate glass (24-well) or sterile polystyrene (96-well) |
| Chamber Volume | 80–1700 µL (24-well) |
| Dimensions (per 24-channel reader) | 163 × 89 × 22 mm |
| Weight (per reader) | 380 g |
| Brand | Edaphic |
|---|---|
| Origin | Australia |
| Model | HPV-06 |
| Measurement Principle | Heat Pulse Velocity (HPV) |
| Flow Range | –200 to +1000 cm/hr (heat velocity) |
| Resolution | 0.001 cm/hr |
| Accuracy | ±0.1 cm/hr |
| Probe Diameter | φ1.3 mm |
| Probe Length | 30 mm |
| Thermistor Positions | 10 mm (outer), 20 mm (inner) |
| Inter-probe Spacing | 6 mm |
| Operating Temperature Range | –30 to +70 °C |
| Response Time | 200 ms |
| Heater Resistance | 39 Ω |
| Energy Input | 400 J/m |
| Power Supply | 12 V DC |
| Output Signal | SDI-12 |
| Cable Length | 5 m (max. 60 m) |
| Key | Origin: China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DHP3D / DHP2D / DHP1D |
| Temperature Range | R.T.+5 to 60 °C |
| Temp. Uniformity | ±1 °C at 37 °C |
| Temp. Stability | ±0.5 °C |
| Chamber Volume | 201 L (DHP3D) |
| Power Rating | 0.6 kW |
| Construction | Stainless Steel Interior |
| Control System | PID Digital Temperature Controller |
| Safety Features | Independent Over-Temperature Protection & Short-Circuit Protection |
| Compliance | YY0027-90 |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | Elite Sealer-1 |
| Detection Method | Culture-based Enzyme Substrate Method |
| Instrument Type | Semi-Automatic |
| Target Analytes | Total Coliforms, *Escherichia coli*, Thermotolerant Coliforms (Fecal Coliforms) |
| Sample Types | Drinking Water, Surface Water, Wastewater |
| Sealing Capacity | <14 sec per 51-well or 97-well Quanti-Tray®-style tray |
| Operating Noise | <48 dB(A) |
| External Casing Temperature | <40°C |
| Preheat Time | ~4 minutes |
| Service Life | >50,000 sealing cycles |
| Compliance Standards | GB/T 5750, HJ 1001 |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | ST-NLA3 |
| Price | USD 6,300 (approx. based on ¥45,000 at 1 USD = ¥7.14) |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | BP-2010A |
| Pricing | Available Upon Request |
| Display | 4.3-inch color LCD |
| Measurement Principle | Infrared photoplethysmography (PPG) |
| Method | Tail-cuff occlusion with automated inflation/deflation |
| Temperature Control Range | 30–40 °C (adjustable via host or software) |
| Blood Pressure Range | 0–350 mmHg |
| Pulse Rate Range | 0–1000 BPM |
| Measured Parameters | Systolic BP, Mean Arterial Pressure (MAP), Diastolic BP, Heart Rate |
| Data Storage | SD card and/or PC via USB 2.0 |
| Software Features | Automated measurement initiation, post-acquisition editing, averaging (6–7 cycles), scheduled measurements, report generation (PDF/CSV), GLP-compliant audit trail export |
| Throughput | Up to 3 rodents per session (sequential) |
| Measurement Duration | ≤15 min (rats), ≤5 min (mice) |
| Compliance | Designed for ISO 13485-aligned manufacturing environments |
| Brand | Jihepu |
|---|---|
| Origin | Shandong, China |
| Model | DW-GL290 |
| Effective Capacity | 290 L |
| Storage Temperature Range | –10 °C to –65 °C |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Consumption | 1200 W |
| Climate Class | N |
| Cabinet Type | Upright, Side-Opening Dual-Door Design |
| Refrigeration Method | Direct Cooling |
| Insulation | CFC-Free Polyurethane Foam with Enhanced Thickness |
| Compressor | Hermetic High-Efficiency Compressor (International Brand) |
| Temperature Sensor | Platinum Resistance Thermometer (Pt100) |
| Control System | Microprocessor-Based Digital Temperature Controller |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | Compact XS / S / M / L / XL |
| Gel Thickness | 5 mm |
| Sample Capacity | 25 wells |
| Voltage Range | 0–250 V |
| Current Range | 0–100 mA |
| Dimensions (W×D×H) | 20 × 15 × 8 cm |
| Instrument Type | Protein Electrophoresis Apparatus |
| Compliance | CE-marked, RoHS-compliant, designed for IEC 61010-1 safety standards |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | Drug Encapsulation System for PLGA Nanoparticles |
| Chip Type | Single-use microfluidic chip |
| Chip Material | Glass/PDMS hybrid (biocompatible, solvent-resistant) |
| Detection Limit | Not applicable (system is a fabrication platform, not an analytical instrument) |
| Channel Dimension | 1–100 µm (customizable per application) |
| Target Payload | Hydrophobic/hydrophilic small-molecule drugs, peptides, siRNA, and other therapeutic actives encapsulated in PLGA |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | ZWY-111G |
| Pricing | Upon Request |
| Temperature Range | RT +5 to 60 °C |
| Temp. Resolution | ±0.1 °C |
| Temp. Uniformity | ≤±1 °C (at 37 °C) |
| Temp. Stability | ≤±0.5 °C (at 37 °C) |
| Orbital Speed | 30–150 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | Φ70 mm |
| Timer Range | 0–500 h |
| Chamber Volume | 237 L |
| Interior Dimensions (W×D×H) | 870 × 600 × 455 mm |
| Shelf Dimensions (W×D) | 770 × 500 mm |
| Shelf Quantity | 1 |
| Max. Capacity | 6 × 5000 mL or 15 × 1000 mL flasks |
| Net Weight | 163 kg |
| Power Supply | AC 220 V, 50/60 Hz |
| Rated Power | 1120 W |
| Operating Ambient | 5–25 °C |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZWYD-4402 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient +5°C to 60°C (refrigerated mode: 4°C to 60°C) |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±1.0°C at 37°C |
| Temperature Stability | ±0.1°C at 37°C |
| Orbital Speed Range | 0–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | Φ0–50 mm (infinitely adjustable) |
| Chamber Capacity per Layer | 182 L |
| Internal Dimensions per Layer (W×D×H) | 920 × 532 × 373 mm |
| Shelf Dimensions | 800 × 430 mm |
| Number of Independent Chambers | 2 |
| Total External Dimensions (W×D×H) | 1100 × 910 × 1210 mm |
| Net Weight | 370 kg |
| Power Supply | AC 220 V, 50/60 Hz |
| Rated Power | 2200 W |
| Refrigerant | R134a |
| Cooling Method | Bottom-mounted forced-air refrigeration with frost-free operation |
| Control System | PID-controlled microprocessor with environmental scanning chip |
| Programming Capability | 9 segments / 18 steps (multi-stage ramp-hold profiles) |
| Timer Range | 0.1–99.9 hours |
| Display | Backlit LCD with real-time parameter monitoring |
| Communication Interface | RS-232 |
| Data Output | Embedded thermal microprinter |
| Safety Certifications | Compliant with IEC 61010-1 for laboratory equipment safety |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GXH-3051C |
| Pricing | Available Upon Request |
| CO₂ Resolution | 0.1 ppm |
| CO₂ Range | 0–1000 ppm |
| CO₂ Accuracy | ±1% F.S. |
| Relative Humidity Resolution | 0.1% RH |
| RH Range | 0–100% RH |
| RH Accuracy | ±2% F.S. |
| Temperature Resolution | 0.1 °C |
| Temp Range | 0–50 °C |
| Temp Accuracy | ±0.2 °C |
| Photosynthetic Photon Flux Density (PPFD) Resolution | 1 µmol·m⁻²·s⁻¹ |
| PPFD Range | 0–3000 µmol·m⁻²·s⁻¹ |
| PPFD Accuracy | ±10 µmol·m⁻²·s⁻¹ |
| Battery | 6 V, 4 Ah Ni-MH |
| Continuous Operation Time | ≥2 h (instrument), ≥3 h (laptop) |
| Charging | 220 V AC, 12 h full charge |
| Airline Length | 1.2 m |
| Net Weight | 2.5 kg |
| Brand | LIVOBOT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EosBot® Clone-I |
| Instrument Type | Single-Needle Colony Picking Workstation |
| Compatible Microorganism | Escherichia coli |
| Inoculation Modes | Solid-to-Liquid, Liquid-to-Solid |
| Picking Speed | ≥320 colonies/hour |
| Picking Accuracy | 98% |
| Target Plate Formats | Disposable tips |
| Dimensions (D×W×H) | 632 mm × 490 mm × 550 mm |
| Brand | LIVOBOT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | EosBot® PE96 |
| Pricing | Available Upon Request |
| Brand | LIVOBOT |
|---|---|
| Origin | Beijing, China |
| Manufacturer | LIVOBOT |
| Type | Domestic |
| Model | EosBot Seq24 |
| Instrument Category | Integrated Library Prep & QC System |
| Library Prep Type | NGS Library Preparation System |
| Supported Plate Format | 96-well |
| Overall Function | Fully Automated Library Construction + On-instrument Quantification & QC |
| Dimensions (W × D × H) | 1200 mm × 850 mm × 1050 mm |
| Weight | 300 kg |
| Brand | LIVOBOT |
|---|---|
| Model | EoSonics® FRAG96 |
| Origin | Beijing, China |
| Manufacturer | LIVOBOT (OEM/ODM Producer) |
| Regulatory Status | NMPA Class I Medical Device Registration, CB & CE Certified |
| Nucleic Acid Fragment Size Range | 100 bp – 5 kb |
| Sample Throughput | 1–96 samples per run |
| Operating Ambient Temperature | 20–30 °C |
| Rated Power Input | 450 VA |
| Compatible Vessel Format | Standard 96-well PCR plates, cell culture plates (open-tube format, no proprietary consumables required) |
| Independent Parameter Zones | Up to 12 rows (each row configurable with unique sonication intensity/duration) |