Life Science Instruments
Filter
Showing 1531–1560 of 2785 results
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Voyager |
| Capacity Range | 200–786 L |
| Sample Capacity | 10,400–38,400 × 2 mL Cryovials |
| Storage Mode | Dual-phase (Liquid & Vapor) |
| Neck Opening | Wide-mouth |
| Evaporation Rate | Optimized Low-loss Design |
| Monitoring System | CryoMemo Integrated Temperature & Level Monitoring |
| Construction | Medical-grade 304/316 Stainless Steel |
| Compliance | Designed to meet ISO 13485 principles for medical device storage environments |
| Intended Use | Long-term cryopreservation of biological specimens in GxP-regulated settings |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | VSHIPPER |
| Construction | Aerospace-grade aluminum alloy |
| Intended Use | Short-to-medium duration biological sample transport (including air freight) |
| Static Hold Time | Up to 10 days (typical, dependent on ambient conditions and fill level) |
| Capacity | 10–30 L liquid nitrogen (model-dependent) |
| Sample Access | Top-loading with porous cryo-absorbent liner for controlled LN₂ release and reduced boil-off during access |
| Compliance | IATA PI 650 compliant for air transport of biological substances |
| Certification | CE-marked per EU Pressure Equipment Directive (PED 2014/68/EU) for non-pressurized cryogenic vessels |
| Brand | Froilabo |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | XT Series |
| Price Range | USD 6,800 – 13,500 |
| Brand | FUELSTAT |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FUELSTAT® One |
| Detection Throughput | 1 sample per test |
| Brand | FUELSTAT |
|---|---|
| Origin | United Kingdom |
| Model | FUELSTAT® resinae PLUS |
| Instrument Type | Field-Deployable Rapid Microbial Detection Kit |
| Detection Targets | Hormoconis resinae (H. res), bacteria, fungi, and metabolically active yeasts |
| Reporting Format | Mass-based quantification (µg/mL of microbial biomass) |
| Compliance | ASTM D8070, IATA Guidance, JIG Online Approved, referenced in OEM AMMs |
| Time-to-Result | ≤10 min assay time, ≤15 min full report generation |
| Sample Volume | 4 drops (≈200 µL) of fuel |
| Software Integration | iOS/Android mobile application with encrypted data logging and cloud sync |
| Regulatory Context | Supports GLP-aligned field testing |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Fully Automated Radiopharmaceutical Dispensing Robot |
| Pricing | Available Upon Request |
| Brand | FuTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SN415 |
| Pricing | Upon Request |
| Technology Platform | Nanoscale Flow Cytometry |
| Instrument Type | High-Parameter Flow Cytometer with Sorting Capability |
| Intended Use | Research-Only |
| Laser Configuration | Up to 4 Lasers |
| Detection Channels | 2 Scatter (FSC/SSC) + Up to 13 Fluorescence Parameters |
| Acquisition Rate | 10,000 Events per Second |
| Compensation | Automated and Manual Compensation Support |
| Nozzle Sizes | 70 µm, 85 µm, 100 µm, 130 µm |
| Sorting Capability | Yes |
| Sorting Throughput | 10,000 Events per Second |
| Sorting Output | 4-Way Sorting |
| Voltage Adjustment Required | Yes |
| Brand | Genemeter |
|---|---|
| Model | DiOne |
| Instrument Type | Digital PCR System |
| Sample Throughput | 4–32 samples per run (integrated droplet generation, thermal cycling, and fluorescence readout) |
| Heating Rate | ≥8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Origin | Sichuan, China |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Brand | GengYu |
|---|---|
| Origin | Zhejiang, China |
| Model | DLSB-5/80 |
| Bath Volume | 5 L |
| Bath Dimensions (mm) | Ø220 × 180 |
| Coil Inner Diameter (mm) | Ø200 |
| Opening Diameter (mm) | Ø195 |
| Temperature Range | Ambient to −80 °C |
| Minimum No-Load Temperature | −82 °C |
| Optimal Ambient Temperature | 5–25 °C |
| Relative Humidity | 60–80% RH |
| Power Supply | 220 V / 380 V ±10%, 50 Hz |
| Refrigeration Capacity | 1956–180 W (at varying setpoints) |
| Temperature Control Range (Instrument Display) | −150 to 100 °C |
| Temperature Stability | ±0.5 °C |
| Sensor Type | PT100 |
| Circulation Pump Power | 100 W |
| Head | 4–6 m |
| Flow Rate | 20 L/min |
| Max. System Pressure | 2 MPa |
| Compressor | Danfoss hermetic refrigeration compressor |
| Refrigerant | R22 |
| Circulation Loop Material | SUS304 stainless steel |
| Cabinet Finish | Epoxy-coated corrosion-resistant spray paint |
| Unit Dimensions (W×D×H, mm) | 510 × 345 × 650 |
| Net Weight | 63 kg |
| Safety Protections | Leakage protection, overcurrent circuit breaker, overload relay, compressor high-pressure switch, pump thermal protector, compressor timer, self-diagnostic temperature control system |
| Brand | Genscript |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AmMag™ Quatro |
| Price Range | USD 70,000 – 140,000 |
| Brand | Getotec |
|---|---|
| Origin | Zhejiang, China |
| Model | ClinCap 1000 |
| Instrument Type | Clinical Protein Capillary Electrophoresis Analyzer |
| Regulatory Status | Filed Medical Device (Zhejiang Hangzhou Medical Device Filing No. Zhe Hang Yi Bei 20211180) |
| Application Scope | Serum Protein Electrophoresis, Serum Immunofixation Electrophoresis (IFE), Hemoglobin Electrophoresis, HbA1c Quantification |
| Automation Level | Fully Automated Sample Loading from Primary Tubes |
| Detection Mode | UV Absorbance at 200–214 nm |
| Software Compliance | Audit Trail, User Access Control, Data Integrity Features per GLP/GMP Principles |
| Brand | GLASER |
|---|---|
| Origin | Jiangsu, China |
| Model | SMART ETCH UV |
| Laser Wavelength | 355 nm |
| Pulse Width | 10 ± 5 ns @ 40 kHz, 20 ± 5 ns @ 100 kHz |
| Average Power | 7 W @ 60 kHz |
| Pulse Energy | 125 µJ |
| Output Power Range | 1–100% |
| Max Scanning Area | 110 mm × 110 mm |
| Beam Quality (M²) | ≤ 1.2 |
| Scan Speed | 13,000 mm/s |
| Delidding Speed | ≥ 3,000 mm/s |
| Single-Pass Depth Control | 0.01–1.0 mm |
| Sample Height Range | 0.5–70 mm |
| Camera Resolution | 20 MP color CCD |
| Filtration Efficiency | >98% for particles ≥ 0.3 µm |
| Operating Gas | Compressed air or N₂, 0.3 MPa |
| Safety Class | Class I (interlocked) |
| Dimensions (W×D×H) | 730 × 1100 × 1600 mm |
| Weight | 280 kg |
| Brand | AMAE (Shenzhen Guoji) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Fully Automated |
| Detection Target | Dispersed/Field-Based Bacterial Pathogens |
| Sample Type | Swab, Environmental Water, Food Homogenate, or Clinical Specimen (pre-extracted nucleic acid) |
| Detection Time | ≤25 min |
| Throughput | 6 samples per run |
| Dimensions | Compact and Field-Portable (≤300 × 220 × 180 mm) |
| Detection Principle | Isothermal LAMP Amplification Coupled with PSFN Nanoparticle-Based Visual & Optical Aggregation Readout |
| Brand | Gongyi Yuyi Instrument |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YDF-1L, YDF-2L, YDF-3L, YDF-5L |
| Motor Power | 40 W |
| Speed Range | 0–800 rpm (digital display) |
| Material | GG-17 borosilicate glass |
| Vacuum Rating | −0.098 MPa |
| Operating Pressure | Negative pressure (up to −0.098 MPa gauge) |
| Electrical Supply | 220 V AC |
| Sealing | PTFE components |
| Stirring Assembly | PTFE-coated impeller |
| Temperature Control | Compatible with external oil/water bath (not integrated) |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FTA-1 |
| Price | Upon Request |
| Vacuum Pressure | −500 mbar |
| Collection Bottle Capacity | 1 L |
| Operating Voltage | 12 V DC |
| Input Power Supply | 12 V DC / 230 V AC adapter included |
| Filter Pore Size | ≤0.027 µm (hydrophobic microbial filter, >99.9% retention efficiency) |
| Tubing Material | Polyethylene |
| Dimensions (W × D × H) | 140 × 180 × 220 mm |
| Weight | 1.8 kg |
| Optional Accessories | MA-8 (8-channel adapter kit), MA-8T (8-channel collection tips), FA-1 (replaceable hydrophobic filter cartridge) |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Product Type | Imported Instrument |
| Model No. | 3-7413-01 |
| Power Supply | AC 220 V, 50/60 Hz, Max. 75 W |
| Dimensions (H×W×D) | 445 × 425 × 420 mm |
| Net Weight | 13.5 kg |
| Microgravity Simulation Range | ≤1 × 10⁻³ G |
| Hypergravity Range | 2–3 G |
| Sample Capacity | Up to twelve T25透气培养瓶 |
| Accelerometer Integration | Yes, real-time g-force monitoring |
| Incubator-Compatible Design | Yes (fits standard CO₂ incubators) |
| Brand | Grundium |
|---|---|
| Origin | Finland |
| Model | Ocus |
| Imaging Principle | High-Resolution Whole-Slide Scanning via Motorized Stage & Precision Optics |
| Objective Resolution | 0.48 µm/pixel (20× objective), 10 µm/pixel (1× overview lens) |
| Scan Area | User-Defined ROI (e.g., 15 mm × 15 mm in ~2 min) |
| Focus Mechanism | Fully Automated Z-Axis Autofocus + Software-Based Fine-Tuning & Manual Override |
| Stage | Motorized XY Stage Compatible with Standard 75 mm × 25 mm Microscope Slides |
| Onboard Compute | Integrated NVIDIA GPU-Accelerated Embedded PC |
| Storage | 500 GB Internal SSD, Expandable via USB 3.0 |
| Image Formats | TIFF, SVS, MRXS (Open Standard Compliant) |
| Connectivity | 1 GbE Ethernet, IEEE 802.11ac Wi-Fi, Offline Operation Supported |
| Dimensions (W×D×H) | 180 × 180 × 190 mm |
| Weight | 3.5 kg |
| Illumination | Köhler-Optimized LED Light Engine |
| Sensor | 6 MP Monochrome/Color CMOS Sensor |
| UI Platform | Web-Based Interface (HTML5), Touchscreen-Compatible, Remote Access via Any Modern Browser |
| Compliance | Designed for GLP/GMP-Adjacent Workflows |
| Maintenance | Open-Chamber Design for Rapid Slide Loading and Optical Path Cleaning |
| Brand | GUOYI |
|---|---|
| Model | WHY-2HS |
| Power Supply | 220 V, 50 Hz |
| Total Power | 1600 W |
| Oscillation Mode | Reciprocating |
| Frequency Range | 0–300 rpm (adjustable) |
| Stroke Amplitude | 20 mm |
| Temperature Range | Ambient to 99 °C |
| Construction | Stainless steel water bath tank, cold-rolled steel housing with powder coating |
| Heating System | Bottom-mounted immersion heater |
| Control | Digital PID temperature controller with setpoint memory and overshoot suppression |
| Speed Control | Digital display with constant-speed feedback circuit |
| Compliance | Designed for GLP-compliant labs |
| Safety Features | Grounded chassis, dry-run protection, spill-resistant control panel |
| Brand | Gyros Protein Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Symphony® X 24-Channel Fully Automated Peptide Synthesizer |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale per Reactor | 5 µmol – 1.0 mmol |
| Total Maximum Capacity | 24 mmol |
| Number of Reactors | 24 |
| Reactor Volumes | Disposable Plastic Vessels – 10 mL, 45 mL |
| Brand | GZGY (CZGY) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | GZX-150 |
| Price | Upon Request |
| Temperature Range | 5–50 °C (dark), 10–50 °C (with illumination) |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Stability | ±0.5 °C |
| Illuminance Range | ≥5000 lx (6-level adjustable) |
| optional high-intensity mode | 0–22,000 lx (6-level) |
| Heating Power | 300 W |
| Cooling Power | 183 W |
| Inner Chamber Dimensions (W×D×H) | 450×450×750 mm |
| Net Volume | 150 L |
| Shelving | 3 stainless-steel adjustable shelves |
| Timer Range | 1–9999 minutes or hours |
| Construction | Cold-rolled steel exterior with epoxy powder coating |
| Safety | Dual over-temperature protection (chamber + independent air duct sensor) |
| Control System | Microprocessor-based programmable controller with LCD touchscreen interface, PID temperature regulation, power-loss memory function |
| Optional Accessories | Humidification module, BOD sockets, thermal printer, data logger, custom chamber dimensions |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | EZ3000 |
| Measurement Principle | Batch-type Direct Ion-Selective Electrode (ISE) Method |
| Compliance | ASTM D4658-15 |
| Detection Range | EZ3017: 1–10 mg/L |
| EZ3018 | 10–100 mg/L |
| Detection Limit | EZ3017: ≤0.5 mg/L |
| EZ3018 | ≤2.5 mg/L |
| Accuracy | ≤2% F.S. (with certified standard solutions) |
| Measurement Interval | 5 minutes (configurable) |
| Calibration | Automated two-point calibration (frequency user-configurable) |
| Validation | Automated, frequency user-configurable |
| Operating Temperature | 5–35°C ±5°C (avoid direct sunlight and rain exposure) |
| Relative Humidity | 5–95% non-condensing |
| Reagent Storage Temp. | 10–30°C |
| Sample Flow Rate | 100–300 mL/min |
| Sample Temperature | 10–30°C |
| Power Supply | 110–240 VAC, 50/60 Hz, max. 120 VA |
| Analog Output | 4–20 mA (standard 1 channel, up to 8 optional) |
| Digital Output Options | RS232, Modbus TCP/IP, Modbus RTU (RS485) |
| Sample Requirements | Max. particle size ≤100 µm |
| Certifications | CE, UL |
| Enclosure Rating | Analyzer housing: IP55 |
| PC panel | IP65 |
| Dimensions (H×W×D) | 690 × 465 × 330 mm |
| Shipping Weight | 30 kg |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EZ4000 |
| Pricing | Available Upon Request |
| Measurement Principle | Acid–Base Titration with Standardized HCl |
| Detection Method | Photometric Endpoint Detection (610 nm or 620 nm) |
| Measured Parameters | Total Alkalinity, Free Alkalinity, Total Hardness, Calcium Hardness |
| Range (Alkalinity) | 100–5000 mg/L as CaCO₃ |
| Range (Hardness) | 100–1000 mg/L as CaCO₃ (EZ4041/EZ4044) |
| LOD (EZ4043) | ≤0.05 mg/L (via LED Immersion Probe) |
| Other Models | ≤10 mg/L |
| Cycle Time | 10–15 min per analysis |
| Operating Temperature | 5–35 °C ±5 °C (indoor, non-sunlit, non-rain-exposed) |
| Sample Temperature | 10–30 °C |
| Storage Temp (Analyzer) | −20 to +55 °C |
| (Electrodes) | −15 to +55 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Power Supply | 110–240 VAC, 4 A, 50/60 Hz |
| Max. Power Consumption | 150 VA |
| Analog Output | 4–20 mA (1 standard channel, up to 8 optional) |
| Pneumatic Supply | Dry, oil-free air compliant with ISA-S7.0.01-1996 |
| Sample Flow Rate | 100–300 mL/min |
| Sample Requirements | Particulate max. 100 µm, suspended solids <0.1 g/L, turbidity <50 NTU |
| Certifications | CE, UL |
| Enclosure Rating | Analyzer Cabinet IP55, Front Panel PC IP65 |
| Dimensions (W×H×D) | 690 × 465 × 330 mm |
| Shipping Weight | 25 kg |
| Brand | Hach |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | HC9420 |
| Instrument Type | Single-Port |
| Application Scope | In-situ Process Monitoring (Bioreactors & Fermenters) |
| Electrode Configuration | Composite Glass + Reference Electrode |
| Electrode Count | 2 (Integrated pH-Sensing and Reference Elements) |
| Electrode Spacing | ~10 mm |
| Electrode Diameter | 12 mm |
| Available Lengths | 120 mm / 225 mm / 325 mm / 425 mm (Customizable Stem Length) |
| pH Range | 0–14 |
| Response Time (t₉₀) | <60 s |
| Operating Temperature | 0–130 °C |
| Max. Pressure Rating | 6 bar (gauge) |
| Junction Type | Dual-Liquid-Junction with Ceramic Frit |
| Temperature Sensor | Integrated PT1000 RTD |
| Membrane Material | High-Temperature Borosilicate Glass |
| Gel Electrolyte | Pre-pressurized Polymer Gel |
| Sterilization Compatibility | Validated for CIP (Clean-in-Place) and SIP (Steam-in-Place) per ISO 13485 & ASME BPE guidelines |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | HMA-TCU |
| Measurement Principle | High-Temperature Acid Digestion + Bathocuproine Spectrophotometry at 470 nm |
| Range | 0.1–10 mg/L Cu |
| Reagent Consumption | ≤1 month per kit |
| Waste Volume | 1.4 L/month |
| Analog Output | 2 × 4–20 mA (≤600 Ω, isolated) |
| Digital Output | RS-485 MODBUS-RTU, RS-232C |
| Relay Outputs | 2 SPDT (AC200 V/3 A, DC24 V/3 A, resistive load) |
| Operating Environment | 10–40 °C, ≤85 % RH (non-condensing) |
| Power Supply | AC 200 V ±10 %, 50 Hz |
| Power Consumption | 380 VA (max), 130 VA (avg) |
| Dimensions (H×D×W) | 900 × 255 × 600 mm |
| Weight | ~50 kg |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | NA9600 sc |
| Detection Limit | 0.01 ppb |
| Measurement Range | 0.01–10,000 ppb (non-cation-bed mode) |
| Accuracy | ±0.1 ppb (0.01–2 ppb, non-cation-bed) |
| Repeatability | <0.02 ppb or 1.5% of reading (whichever is greater) |
| Response Time | T90 ≤ 2 min (1–100 ppb) |
| Sample Temperature Range | 5–45 °C |
| Ambient Operating Temperature | 5–50 °C |
| Sample Pressure | 0.2–6 bar |
| Sample Flow Rate | 100–150 mL/min |
| Sample pH Adjustment | Diisopropylamine (DIPA), 1 L/90 days (non-cation-bed), 1 L/month (cation-bed) |
| Enclosure Rating | NEMA 4 / IP65 (with enclosure) |
| Display | 5.7-inch color LCD |
| Analog Outputs | 6 isolated 4–20 mA (max 600 Ω load) |
| Digital I/O | 6 programmable relay outputs (SPDT, 5 A, 240 VAC), 6 isolated TTL/dry-contact digital inputs |
| Communication Protocols | HART, PROFIBUS DP, Modbus RTU/TCP |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (H×W×D) | 681 × 452 × 335 mm (with enclosure) |
| Weight | 20 kg (with enclosure, no reagents) |
| Maintenance Interval | Electrolyte, activator, and calibration solutions replenished every 90 days |
| Brand | HACH |
|---|---|
| Origin | USA |
| Model | ULR CL17sc |
| Measurement Principle | DPD (N,N-Diethyl-p-phenylenediamine) Colorimetric Method |
| Measurement Range | 0.008–5 mg/L Cl₂ |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) for 0–4 mg/L |
| Detection Limit | 0.008 mg/L Cl₂ at 25°C |
| Cycle Time | 2.5 minutes |
| Sample Flow Rate | 60–200 mL/min |
| Inlet Pressure | 0.3–5.2 bar (to Y-strainer) |
| Sample Temperature | 5–40°C |
| Operating Temperature | 5–40°C |
| Operating Humidity | 0–90% RH, non-condensing |
| IP Rating | IP66 |
| Power Supply | 12 VDC, max. 400 mA |
| Dimensions (H×W×D) | 342 × 329 × 177 mm |
| Weight | 4.1 kg |
| Light Source | LED at 510 nm, 1 cm optical path |
| Certifications | CE (EN 61326-1, CISPR 11, EN 50581), ACMA RCM, Korea KC, FCC DoC, IEC/EN 60529, ICES-003 |
| Brand | Haglof Inc. |
|---|---|
| Origin | Sweden |
| Model | Postex |
| Dimensions | 93 × 63 × 72 mm |
| Weight (instrument) | 243 g |
| Weight (tripod assembly) | 4.85 kg |
| Ultrasonic Range | ≥30 m (with 360° adapter: ≥20 m) |
| Laser Range | 0.46–700 m |
| Laser Accuracy | ±4 cm |
| Angular Accuracy | ±0.1° |
| Angular Resolution | 0.1° |
| Distance Resolution (ultrasonic) | 0.01 m |
| Distance Resolution (laser, DME mode) | 0.01 m |
| Operating Temperature | −20 °C to +45 °C |
| IP Rating | IP67 / NEMA 6 |
| Laser Class | IEC 60825-1:2001 Class 1M, FDA 21 CFR Part 1040.10 Class 1 |
| Battery | Internal 3.7 V rechargeable Li-ion (~9,000 measurements per charge |
| Interface | USB Mini-B, Bluetooth SPP (PIN: 1234), IR |
| Data Output Format | NMEA or ASCII |
| Tripod Arm Extension | Up to 125 cm from center |
| Reflector Beacon (A/B/C) | Ø70 mm, 85 g each, 1.5 V AA alkaline, max. 9 mW |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CJ-L37 |
| Temperature Control Range | −180 °C to +50 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Temperature Uniformity | < ±2 °C |
| Cooling/Heating Rate Adjustment Range | 0.1–12 °C/min |
| Display Resolution | 0.1 °C |
| Liquid Nitrogen Level Monitoring | Real-time with <20% threshold alarm |
| Preloaded Programs | 6 standard protocols |
| Custom Protocol Support | Yes |
| ADRC Control Algorithm | Patented Active Disturbance Rejection Control |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DW-86L626 |
| Quotation | Upon Request |
| Climate Class | N |
| Cooling Method | Direct Cool |
| Defrost Mode | Manual |
| Refrigerant | Eco-friendly Mixed HFC Blend |
| Noise Level | <50 dB(A) |
| Power Consumption | 1200 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Internal Temperature Range | -40 °C to -86 °C |
| Temperature Uniformity | ±6 °C |
| External Dimensions (W×D×H) | 1035 × 900 × 1980 mm |
| Internal Dimensions (W×D×H) | 760 × 630 × 1310 mm |
| Net Capacity | 626 L |
| Net Weight | 301 kg |
| Compressor Type | Hermetic Reciprocating (Dual Unit) |
| Compressor Power | 927 W per unit |
| Door Configuration | 1 Outer Foam-Insulated Door + 4 Independent Inner Foam Doors |
| Insulation | VIP Vacuum Insulation Panels + Zero-ODP Polyurethane Foam |
| Temperature Control | Microprocessor-Based Digital Controller with LED Display |
| Temperature Sensor | Precision Thermistor |
| Shelving | Adjustable, Load Capacity 50 kg per shelf |
| Casters | Equipped with Locking Swivel Casters |
| Monitoring Ports | 1 Access Port for External Probe or Data Logger |
| Alarm System | Comprehensive Audible/Visual Alarms (High Temp, Low Temp, Power Failure, Door Ajar, Filter Clog, Sensor Fault, Ambient Over-Temp, Low Battery, Voltage Fluctuation) |
| Regulatory Compliance | Registered Medical Device (China NMPA) |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DW-86L728BPST(R) |
| Configuration | Upright |
| Effective Volume | 728 L |
| External Dimensions (W×D×H) | 1300 × 1045 × 1980 mm |
| Power Supply | 220 V, 50 Hz |