Life Science Instruments
Filter
Showing 1621–1650 of 7558 results
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YMJ-P2 |
| Price | USD 950 (est.) |
| Width Range | 0–155 mm |
| Length Range | 0–2000 mm |
| Max Leaf Length | 0–290 mm |
| Max Leaf Width | 0–210 mm |
| Measurable Area Range | 1–600 cm² |
| Hole Detection Threshold | ≥0.1 cm² |
| Accuracy | ±2% |
| Long-Term Stability | <±2% deviation over 12 months |
| Response Time | 50 ms |
| Operating Temperature | −30 °C to +80 °C |
| Relative Humidity | 0–100% RH |
| Image Sensor | 16 MP CMOS high-resolution imager |
| Illumination | Uniform LED backlight (cold white, 6000 K) |
| Platform Dimensions | 350 × 285 × 10.5 mm (base), 350 × 285 × 320 mm (full unit) |
| Net Weight | 1.495 kg (imager + base) |
| Integrated Tablet | 10-inch Android 11 device (800 × 1280 px, 16 GB storage, Wi-Fi/4G, DC 12 V / 1.5 A power input) |
| Data Export | CSV, Excel (.xlsx), PNG/JPEG image + metadata |
| Cloud Integration | RESTful API support for secure HTTPS upload |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YMJ-S |
| Width Range | 0–155 mm |
| Length Range | 0–2000 mm |
| Scanning Area | 220 × 300 mm |
| Optical Resolution | 4800 dpi |
| Area Resolution | 0.001 cm² |
| Length/Width Resolution | 0.01 cm |
| Operating System Compatibility | Windows 7 or later (Windows 10 recommended) |
| Data Export | Excel (.xlsx), CSV, Cloud Platform (charting: bar, line |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Range | 0–4.99 MPa (0–49.9 bar) |
| Accuracy | ±0.01 MPa |
| Display | 4.3″ Color LCD Touchscreen |
| Pressure Chamber Volume | 4 L, Rated Pressure: 12 MPa |
| Data Storage | Up to 9,999 records |
| Power Supply | Rechargeable Battery (24 h @ max brightness) |
| Dimensions (Instrument Box) | 520 × 330 × 206 mm |
| Dimensions (Pressure Chamber Box) | 530 × 420 × 206 mm |
| Net Weight | ~12 kg per box |
| Units | MPa / bar selectable |
| Compliance | Designed for GLP-aligned field and lab use |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Place Reference |
| Pricing | Upon Request |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | 68634 |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 645 |
| Temperature Range (Dark) | 0–40°C |
| Temperature Range (Light, 650 µmol·m⁻²·s⁻¹) | 10–40°C |
| Humidity Control Range | 40–90% RH |
| Illumination Max | 650 µmol·m⁻²·s⁻¹ (at 900 mm above shelf) |
| Internal Dimensions (W×D×H) | 1800 × 900 × 1500 mm |
| Effective Volume | 2500 L |
| Temp Uniformity | ±2.5°C |
| Temp Stability | ±0.1°C |
| Temp Repeatability | ±0.5°C |
| Temp Fluctuation | ±1.0°C |
| [Brand | CONVIRON (Canada) |
|---|---|
| Origin | Canada |
| Model | GEN1000 |
| Chamber Types | TA Kit (1-layer), SH Kit (2/3-layer), TC Kit (4-layer), IN Kit (4-layer) |
| Controller | CMP6060 industrial PLC with 7" color touchscreen, Windows SE OS |
| Temperature Range | 4–40°C (dark), 10–45°C (light) |
| SH Kit XTIER | 15–45°C (light) |
| Humidity Control | Ultrasonic humidification, 75% RH max (light), 90% RH max (dark) |
| Light Source | Standard 12W T5 full-spectrum LED |
| PAR intensity | 275–700 µmol/m²/s @ 15 cm |
| Airflow | Vertical or horizontal laminar flow via plenum chamber |
| Internal Volume | 1000 L |
| External Dimensions | 1040 × 825 × 1955 mm (W×D×H) |
| Data Logging | Local: 30-sec intervals |
| Remote (optional) | 18-sec intervals |
| Compliance | ISO 9001, QPS certified |
| Power Supply | 230 V, 1-phase, 50 Hz, 16 A] |
| Brand | CONVIRON (Canada) |
|---|---|
| Origin | Canada |
| Model | GR48 |
| Chamber External Dimensions | 2950 mm (W) × 2950 mm (D) × 2600 mm (H) |
| Usable Cultivation Area | 4.5 m² |
| Usable Cultivation Volume | 9130 L |
| Internal Volume | 14676 L |
| Cultivation Height | 2030 mm (extendable to 2340 mm with height extension kit) |
| Lighting | T5 fluorescent + halogen lamps, standard intensity 600 µmol/m²/s at 15 cm |
| Optional High-Intensity Lighting | Ceramic metal halide, up to 650 µmol/m²/s at 1 m |
| Temperature Range | 5–25°C (lights off), 15–35°C (lights on) |
| Temperature Uniformity | ±0.5°C |
| Humidity Control | Up to 85% RH (lights on), 90% RH (lights off) |
| CO₂ Control | Optional ±200 ppm to 2900+ ppm |
| Controller | CMP6060 industrial PLC running Windows Embedded SE, 7-inch color touchscreen, USB data export, 16 master programs (48 subroutines each), 30-second local logging interval |
| Compliance | ISO 9001 certified manufacturing |
| Brand | COPAN |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PharmaLab |
| Pricing | Available Upon Request |
| Brand | COPAN |
|---|---|
| Origin | Italy |
| Model | WASPLab® |
| Type | Integrated Automated Bacteriology Platform |
| Compliance | CE-IVD, ISO 15189-ready architecture |
| Software | WASPLab® WebApp (browser-based), LIS/HIS integration via ASTM/HL7 |
| Optional Module | Colibrí™ Automated Colony Picker |
| Brand | Corning |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 6575 Universal Clear PCR Sealing Tape |
| Pricing | Available Upon Request |
| Brand | Corning |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Cell Culture Roller Bottles |
| Pricing | Available Upon Request |
| Brand | CoSE Instruments |
|---|---|
| Origin | USA |
| Model | SciSpinner Max 3D |
| Rotation Range | 0.05–10 rpm |
| Resolution | 0.001 rpm |
| Imaging | 11.9 MP, 120° FOV, IR-sensitive, autofocus, 1080p/60fps video |
| Illumination | 850 nm IR LED + addressable RGBWW LED array |
| Sensor | 9-axis IMU (gravity, angular velocity, linear acceleration) |
| Power | Dual 5 V / 12 V DC |
| Sample Compatibility | 60 mm & 120 mm Petri dishes, 96-well plates, T25/T75 flasks, 25/50 mL Falcon tubes, plant seedling modules |
| Enclosure Materials | PETG & TPU (biocompatible 3D-printed structural components) |
| Operating Environment | 15–40 °C, 20–95% RH (non-condensing) |
| Acoustic Noise | <40 dB(A) |
| Safety | 12 V DC low-voltage operation with overcurrent and thermal protection |
| Brand | COSEQUE (CHENGDU) TECHNOLOGY CO., LTD. |
|---|---|
| Origin | Sichuan, China |
| Model | MS-1 |
| Dimensions | 215 × 150 × 135 mm (L×W×H, ±3 mm) |
| Current Range | ±2.5 nA |
| Bias Voltage Range | ±2500 mV |
| Sampling Rate | 1 Hz – 200 kHz (16-bit resolution) |
| Input Referred Noise | ≤0.5 pA RMS @ 10 kHz |
| Zero Offset Compensation | ±250 mV |
| Continuous Operation | ≥10 h |
| Interface | USB 2.0 |
| EMC | Integrated Faraday-cage-level shielding |
| Brand | Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-702III |
| Detection Principle | Hot-Wire Semiconductor |
| Detectable Gases | Dual-gas (XP-702III-A/F) or Single-gas (XP-702III-B) |
| Detection Range | City Gas/LPG: 10 ppm |
| Refrigerants (e.g., R407C, R410A) | 30 ppm |
| Response Time | ≤3 s (excluding refrigerant gases) |
| Leak Sensitivity | City Gas/LPG: 3.3×10⁻⁶ Pa·m³/s |
| R407C | 12.4 g/year |
| R410A | 11.2 g/year |
| Alarm | Audible intermittent tone + flashing LED |
| Explosion Protection | Intrinsic Safety Ex ib IIB T3 |
| Operating Environment | −20°C to +50°C, 30–85% RH (non-condensing) |
| Power Supply | Three AA alkaline batteries |
| Battery Life | Approx. 12 h (at 25°C, 60% RH) |
| Dimensions (W×H×D) | 38×130×32 mm (excl. protrusions) |
| Weight | ~190 g (incl. batteries & holster) |
| Standard Accessories | Holster, 3× AA alkaline batteries, adjustable sampling tube with dust filter, guide tube filter element, lanyard |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | AASS |
| Sound Output Range | 20 Hz – 25.5 kHz (audio), 20 Hz – 20 kHz (white noise) |
| Max SPL | 128 dB |
| Stimulus Control | Computer-controlled amplitude, frequency, duration, rise/fall time |
| Optional Modules | Footshock (up to 3.0 mA), Visual Flash Stimulus |
| Chamber Configuration | Single or 8-chamber sound-attenuated enclosures |
| Data Acquisition | Analog signal conditioning (amplification + integration), 16-bit ADC |
| Compliance | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | ACT-100A |
| Channel Capacity | 4 / 8 / 12 channels |
| Video Sampling Rate | ≥4 Hz (frames per second) |
| Motion Detection Resolution | ≥1 mm |
| Compliance | FDA 21 CFR Part 11–ready software architecture, GLP/GMP-compatible data audit trail |
| Data Export | Excel (.xlsx), QuickTime (.mov) |
| Validated Concordance with Trained Human Observers | ≥90% (independently verified by Memory Pharmaceuticals, NJ) |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | ACT-300A |
| Application | Video-based automated tracking for open field, elevated plus maze, radial arm maze, zero maze, conditioned place preference, and custom arena designs |
| Tracking Capacity | Up to 4 animals simultaneously |
| Frame Rate | 15 fps per animal (7 fps when tracking 4 animals) |
| Animal Detection | Robust real-time detection of black or white rodents regardless of size |
| Data Output | Time-in-zone (s/%), zone entries/crossings, path length (cm), body length (mm), orientation angle, mean distance from center, trajectory coordinates, and exportable CSV/Excel reports |
| Software | Limelight v5.x with GLP-compliant audit trail, batch processing, group-wise statistical summary (mean ± SEM), QuickTime movie export, and customizable zone/grid/maze-arm segmentation |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | ACT-400 |
| Camera Channels | 1–4 (expandable) |
| Max Simultaneous Subjects | >200 (50+ per camera) |
| Tracking Frequency | 4 Hz per subject (subject-count dependent) |
| Data Output | CSV, Excel-compatible, ClockLab-compatible |
| Event Marking | Multi-channel timestamped annotations |
| ROI Configuration | User-defined arbitrary zones per camera view |
| IR Sensitivity | Near-infrared optimized (750–950 nm), enabling dark-phase monitoring |
| Software Platform | BigBrother Analysis Suite + ClockLab integration |
| Compliance | GLP-supportive audit trail (software-configurable), FDA 21 CFR Part 11 ready (with optional validation package) |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | FREEZEFRAME-FW |
| Camera Interface | Standard CCD or USB 2.0/3.0 Video Input |
| Operating System | Windows 10/11 (64-bit) |
| Data Output Format | CSV, Excel-compatible, XML |
| Compliance | GLP-supporting audit trail logging (configurable), ISO/IEC 17025-aligned data integrity framework |
| Analytical Output | Immobility duration (s), immobility bouts count, latency to first immobility, total active time (swimming/climbing), motion velocity (px/frame), trajectory heatmaps |
| Software Architecture | Client-server capable, multi-user role-based access control (RBAC) |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | FREEZEFRAME-XW |
| Application | Automated video-based behavioral analysis for murine tail suspension assay |
| Compliance | Designed for GLP-compliant preclinical neuroscience research |
| Data Output | CSV, Excel-compatible, QuickTime export |
| Camera Frame Rate | ≥4 fps |
| Multi-animal Support | Configurable for 4, 8, or 12 subjects simultaneously |
| Motion Detection Algorithm | Patented shadow- and noise-immune motion index computation |
| Software Architecture | Modular, Windows-based, FDA 21 CFR Part 11–ready audit trail optional |
| Brand | Coulbourn |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSE-01001 |
| Pricing | Upon Request |
| Channel Configurations | Single-, Dual-, and 5-Channel Options |
| Speed Control | Programmable Constant & Accelerating Profiles |
| Incline/Decline Adjustment | ±25° Motorized |
| Shock Absorption | Adjustable Compliance Damping |
| Detection Method | Top-Mounted Photobeam Sensors |
| Timing Resolution | 0.1 s Per Chamber |
| Noise Level | <45 dB(A) at 1 m |
| Structural Frame | Powder-Coated Steel with Polycarbonate Enclosures |
| Compliance | Designed for ASTM F2100-22 (Laboratory Equipment Safety), ISO 13485-aligned Manufacturing Practices, GLP-Ready Data Logging |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Operant Behavior Systems |
| Pricing | Available Upon Request |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Rotation Monitor |
| Cage Dimensions | 4" (D) × 3" (W) × 2" (H), 18" ramped cylinder |
| Material | Aluminum, Polypropylene |
| Max. Simultaneous Monitoring Capacity | 64 cages |
| Resolution | 0.01 rad (3.6°) |
| Detection Method | Triple Infrared Transceiver per Station |
| Cable Length | 12 ft |
| Certification | CE compliant |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Countess® |
| Detection Range | 1 × 10⁴ – 1 × 10⁷ cells/mL (optimal: 1 × 10⁵ – 4 × 10⁶ cells/mL) |
| Cell Size Range | 5 – 60 µm |
| Sample Volume | 10 µL |
| Counting Time | ≤30 seconds |
| Staining Method | Trypan Blue exclusion |
| Data Storage | Internal memory with USB export capability |
| Dimensions | 27 × 20 × 19 cm |
| Consumable | Single-use disposable counting chambers |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | COUNTESS® II FL |
| Price Range | USD 7,000 – 14,000 (FOB US) |
| Brand | Applitech |
|---|---|
| Model | BF 100 |
| Principle | Trypan Blue Exclusion with Digital Image Analysis |
| Throughput | 8 samples per run |
| Sample Volume per Channel | 15 µL |
| Analysis Time | ≤90 sec for 8 samples |
| Focus | Auto-focus optical system |
| Compliance | FDA 21 CFR Part 11, GMP-aligned user management and audit trail |
| Software | Integrated analysis suite with multi-field imaging, dilution compensation, growth curve generation, and PDF/Excel/TIFF export |
| Consumable | FL8-slide (8-channel disposable chamber slide) |
| Regulatory Support | IQ/OQ/PQ documentation package included |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | FL 2000 |
| Pricing | Upon Request |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | AItair |
| Detection Time | 150 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 3–180 µm |