Life Science Instruments
Filter
Showing 2221–2250 of 2783 results
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Sartorius OEM/technology license) |
| Model | Octet® R2 |
| Detection Method | Label-free Bio-Layer Interferometry (BLI) |
| Sample Format | 96-well microplate |
| Sample Volume per Well | 200 µL |
| Assay Duration | 2–60 minutes |
| Temperature Control Range | 15–40 °C |
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Octet® R4 |
| Detection Method | Label-Free Biosensor-Based Interferometry (BLI) |
| Sample Format | 96-Well Microplate |
| Sample Volume per Well | 200 µL |
| Assay Duration | 2–60 min |
| Temperature Control Range | 15–40 °C |
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Octet® R8 |
| Instrument Type | Bio-Layer Interferometry (BLI) |
| Detection Mode | Label-Free Detection |
| Sample Format | 96-Well Microplate |
| Sample Volume per Well | 200 µL |
| Assay Duration | 2–60 minutes |
| Temperature Control Range | 15–40 °C |
| Brand | Sartorius |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Bio-Layer Interferometry (BLI) |
| Channel Configuration | 8-Channel Parallel Detection |
| Sample Format | Compatible with 96-well and 384-well microplates |
| Sample Volume per Well | 40 µL |
| Temperature Control Range | 15–40 °C |
| Regulatory Compliance | 21 CFR Part 11 Ready |
| Unattended Operation Duration | Up to 16 hours |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Type | Reusable Luer-Lock/Luer-Slip Needle Filter Holder |
| Membrane Diameter | 13 mm |
| Filtration Area | 0.5 cm² |
| Residual Volume | < 0.03 mL |
| Max Operating Pressure | 5 bar (500 kPa) |
| Sterilization | Autoclavable (121 °C or 134 °C) / Dry Heat (180 °C) |
| Weight | 13 g |
| Material | PTFE (holder), compatible with 13 mm disc membranes |
| Flow Rate (water, 1 bar) | 10 mL/min (0.2 µm PTFE), 18 mL/min (0.45 µm PTFE) |
| Interface | Luer Lock inlet / Luer Slip outlet |
| Catalog No. | 16574 (1/pk) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sartolab® Bottle |
| Pricing | Available Upon Request |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Product Lines | Sartolab® P20, Sartolab® P20 Plus, Sartolab® RF, Sartolab® BT |
| Membrane Material | Polyethersulfone (PES) |
| Pore Sizes | 0.1 µm, 0.22 µm, 0.45 µm |
| Sterilization | Gamma-irradiated, endotoxin-free |
| Compliance | ISO 13485, ISO 8 cleanroom manufacturing, USP Class VI, ISO 10993 biocompatibility, FDA 21 CFR Part 11–ready documentation support |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 16421-A |
| Instrument Type | Automated Sterility Testing System |
| Detection Throughput | Qualitative |
| Filter Cup Capacity | 120 mL (graduated at 50, 75, and 100 mL) |
| Filter Membrane Diameter | 0.45 µm |
| Filtration Method | Peristaltic Pump |
| Flow Rate Control | 0–100 rpm |
| Dimensions (min) | 26 × 22.5 × 54.6 cm (W × D × H) |
| Dimensions (max) | 33.7 × 26.2 × 54.6 cm (W × D × H) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Product Type | Imported Life Science Consumables |
| Model | Vivacon® 500-PCR / Vivacon® 2-PCR |
| Membrane Material | Hydrosart® regenerated cellulose |
| MWCO Options | 2 kDa, 10 kDa, 30 kDa, 50 kDa, 100 kDa, 125 kDa |
| Sterilization | Ethylene Oxide (ETO) treated for PCR-grade applications |
| Sample Volume | 0.5 mL |
| Max. Centrifugal Force | 3,000–14,000 × g depending on MWCO |
| DNA Recovery (30× conc.) | 85–94% |
| Protein Recovery (30× conc.) | 81–95% |
| Compliance | DNase/RNase-free, endotoxin-tested (<0.5 EU/mL), certified PCR-inhibitor-free |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Vivaflow® SU |
| Pricing | Upon Request |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Vivaflow 50 / Vivaflow 50R / Vivaflow 200 |
| Membrane Options | Hydrosart® modified regenerated cellulose (RC) and polyethersulfone (PES) |
| MWCO Range | 2 kDa to 1,000 kDa |
| Pore Sizes | 0.2 µm (microfiltration) |
| Max Sample Volume | Up to 5 L (parallel operation) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Vivaspin 100 |
| Sample Capacity | 100 mL |
| Retentate Hold-up Volume | 350 µL |
| Membrane Orientation | Vertical |
| Operating Modes | Centrifugation and/or Pressure-driven Filtration |
| MWCO Options | 5–1000 kDa (including 0.2 µm pore size) |
| Membrane Types | Regenerated cellulose (RC), Polyethersulfone (PES), Polyvinylidene fluoride (PVDF) |
| Pack Sizes | 2 units (e.g., VC1011) or 10 units (e.g., VC1012) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Vivaspin 500 / 2 / 6 / 15R / 20 / Turbo |
| Membrane Material | Polyethersulfone (PES), Hydrosart®, Cellulose Triacetate (CTA) |
| MWCO Range | 2 kDa – 0.2 µm |
| Sample Volume Capacity | 100 µL – 20 mL |
| Sterility | Non-sterile (unless specified) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | AutoDosage |
| Maximum Weighing Capacity | 610 g / 1500 g / 2200 g (selectable) |
| Weighing Resolution | 0.1 g or 0.01 g |
| Interface | RS-232 serial port |
| Control Interface | Integrated aluminum-finished controller housing with backlit LCD display and membrane keypad |
| Actuation | Solenoid valves with adjustable nozzles for coarse, medium, and fine dispensing |
| Software | PC-based formulation editor with recipe storage (up to 70 protocols), calibration management, and audit-ready log export |
| Structural Base | Vertical-adjustable balance support plate with mounting baseplate |
| Power Supply | 24 V DC unit included |
| Connectivity | Ethernet-ready (optional), standard network cable provided |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AutoFilt |
| Pricing | Available Upon Request |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AutoFilt Z |
| Pricing | Upon Request |
| Max. Filtration Pressure | 5 bar (0.5 MPa) |
| Typical Filtration Volume | ~250 mL |
| Measured Sample Volume | 50 mL |
| Operating Temperature Range | +10 °C to +40 °C |
| Power Supply | 100–240 VAC, 47–63 Hz, 40 W |
| Compressed Air Requirement | ≤10 bar (1.0 MPa), oil-free, Ø outer diameter 6 mm |
| Waste Tube | Ø inner diameter 16 mm |
| Brand | Scienhome |
|---|---|
| Origin | Tianjin, China |
| Model | AP-01P |
| Filter Capacity | 300 mL (funnel), 1 L / 2 L (receiving flask) |
| Construction | Borosilicate glass (up to 270 °C thermal shock resistance) |
| Vacuum Source | Oil-free diaphragm pump |
| Compliance | Designed for ISO/IEC 17025-compliant labs, compatible with USP <788> particulate matter testing and ASTM E2904-21 for solvent clarity validation |
| Accessories | Sintered glass frit (porosity: G3/G4), sealing O-rings, clamp assembly, vacuum tubing kit |
| Operating Pressure Range | 0.05–0.08 MPa (absolute), typical working vacuum: −85 to −95 kPa |
| Brand | Scienhome |
|---|---|
| Model | WDG Series |
| Type | Sterile Filtration Manifold System |
| Compliance | Designed per Chinese Pharmacopoeia 2005 Edition, Appendix XIII-B (Sterility Testing) & XIII-C (Microbial Limits Testing) |
| Configuration Options | 1-, 3-, or 6-position stainless steel manifold |
| Filter Capacity | 100 mL per station |
| Vacuum Requirement | 6–20 L/min (model-dependent) |
| Construction | Borosilicate glass filter housings, food-grade silicone gaskets, 316L stainless steel support frame |
| Weight | 1.2–5.6 kg |
| Dimensions (W×D×H) | 110×110×280 mm (WDG-1) to 660×110×280 mm (WDG-6) |
| Optional Accessories | Sterile collection flasks, oil-free vacuum pump (≥10 L/min), incubator-compatible stainless steel mounting base |
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | Enviro-Genie |
| Instrument Type | Full-temperature orbital shaker/incubator |
| Timer Range | 1 s – 99 hr |
| Oscillation Frequency | 2–70 cycles/min |
| Temperature Range | 4–75 °C |
| Number of Shaking Platforms | 1 |
| Rotation Speed | 1–35 rpm |
| Stirring Speed | 1–2000 rpm (with reverse) |
| Temperature Accuracy | ±0.2 °C |
| Temperature Uniformity | ±0.5 °C |
| Chamber Volume | 24 L |
| Platform Load Capacity | 4.5 kg |
| Net Weight | 36 kg |
| Interface | RS232 |
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | Incubator-Genie |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Programmable Timer Range | Up to 99 hr |
| Oscillation Speed | 3–35 rpm |
| Temperature Range | 28–75 °C |
| Platform Quantity | 1 |
| Temperature Uniformity | ±0.5 °C |
| Temperature Accuracy | ±0.2 °C |
| Chamber Volume | 24 L |
| Platform Load Capacity | 4.5 kg |
| Net Weight | 19.5 kg |
| Interface | RS232 |
| Optional Accessory | 3D Orbit Module |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | CFU-750W-M1 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz ± 1 kHz |
| Ultrasonic Power Output | 750 W |
| Temperature Control Range | −30 °C to 100 °C |
| Sample Throughput | 1–50 L/h |
| Reactor Material | SUS316 Stainless Steel |
| Transducer & Horn Material | Titanium Alloy (Grade 5) |
| Control Interface | 10-inch Capacitive Touchscreen |
| Data Logging | Internal storage with USB export |
| Communication Protocol | Modbus-TCP over RJ45 Ethernet |
| User Access Control | Three-tier permission system (Admin / Operator / Guest) |
| Sterilization Compatibility | In-situ steam sterilization (SIP) or offline autoclaving (121 °C, 2 bar, 30 min) |
| Cooling Architecture | Double-jacketed reactor with external chiller integration (e.g., DC-3006) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HL25-220-2T Series |
| Temperature Control Range | -25 °C to 200 °C |
| Temperature Stability (Bath Medium) | ±0.5 °C |
| Temperature Accuracy (Process Load) | ±1 °C |
| Control Interface | 7-inch Color Touchscreen with Real-time Temperature Curve Display & Logging |
| Control Algorithm | PID Fuzzy Logic |
| Communication Protocol | MODBUS RTU over RS-485 |
| Temperature Feedback Points | Three PT100 Sensors (Unit Internal Temp, Outlet Temp, External Process Temp) |
| Programmability | Up to 5 Programs, Each with 30 Segments |
| Differential Temperature Control | Adjustable ΔT between Jacket and Process Material |
| Safety Protections | Compressor Overload Protection, High-Pressure Switch, Thermal Overload Relay, Low-Level Fluid Sensor, Over-Temperature Cut-off, Sensor Fault Detection |
| System Design | Fully Sealed Closed-Loop Circulation (No Oil Mist at High Temp |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HL25W-820 Series |
| Temperature Control Range | −80 °C to 200 °C |
| Temperature Accuracy (Heat Transfer Medium) | ±0.5 °C |
| Temperature Accuracy (Process Material) | ±1.0 °C |
| Display Interface | 7-inch color touchscreen with real-time temperature curve visualization and logging |
| Control Algorithm | PID-based fuzzy logic control |
| Communication Protocol | MODBUS RTU over RS-485 |
| Max. Operating Medium Temperature | 200 °C |
| Min. Operating Medium Temperature | −25 °C |
| Programmability | Up to 5 multi-step programs, each supporting up to 30 segments |
| Temperature Feedback Points | Three PT100 sensors — chiller internal temperature, outlet fluid temperature, and external process material temperature |
| Safety Protections | Compressor overload protection, high-pressure switch, thermal relay, overtemperature sensor fault detection, low-fluid-level alarm, and integrated self-diagnostic system |
| System Design | Fully sealed closed-loop circulation |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | JY88-IIN |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 250 W (adjustable from 1% to 100%) |
| Sample Volume Capacity | 10–200 mL |
| Display | 7-inch Touchscreen Interface |
| Duty Cycle Range | 0.1–99.9% |
| Standard Probe | 6 mm titanium alloy (TC4) horn |
| Optional Probes | 2 mm, 3 mm, 10 mm |
| Safety Features | Overtemperature, overload, and timer alarms |
| Dimensions (Main Unit) | 430 × 245 × 300 mm |
| Weight (Unit + Transducer) | 8.5 kg |
| Optional Acoustic Enclosure Dimensions | 345 × 345 × 535 mm |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MGC-500 |
| Pricing | Available Upon Request |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SCIENTZ-650J |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–99.9°C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 650 W (adjustable from 1% to 100% in 1% increments) |
| Sample Volume Capacity | 100 µL – 250 mL |
| Display | 7-inch capacitive touchscreen |
| Probe Options | Standard 6 mm tapered probe |
| optional probes | 2, 3, 8, 10, and 13 mm diameter |
| Probe Material | TC4 titanium alloy (aerospace-grade α+β titanium alloy) |
| Cooling Mode | External circulating chiller compatible / internal temperature monitoring with auto-shutdown |
| Safety Features | Overload protection, overtemperature cutoff (user-definable threshold), real-time thermal monitoring, timed operation with ±0.1 s resolution |
| Control Modes | Continuous and pulsed ultrasonication (pulse on/off ratio programmable) |
| Enclosure | Acoustically damped steel chassis with integrated sound-absorbing panels |
| Dimensions (W×D×H) | 312 × 334 × 510 mm |
| Weight | Approx. 28 kg |
| Internal Illumination | LED lighting for sample chamber visibility |
| Sanitization | UV-C lamp integrated into lid assembly (optional activation cycle) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-950E |
| Temperature Range | 0–99°C |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Ultrasonic Power Output | 5–950 W (adjustable) |
| Sample Volume Capacity | 100 µL – 600 mL (probe-dependent) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SCIENTZ-WSQ |
| Pricing | Available upon request |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SCIENTZ18-A |
| Pricing | Upon Request |
| Brand | SCIENTZ |
|---|---|
| Origin | Zhejiang, China |
| Model | UP-250 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 19–25 kHz |
| Ultrasonic Output Power | 250 W |
| Sample Volume Capacity | 0.5–10 mL |
| Display | 4.3-inch Touchscreen |
| Control Modes | Automatic & Manual (footswitch optional) |
| Pulse Duration | 0.1–99 s (on/off) |
| Total Sonication Time | 0.1–99 min |
| Horn Diameter | 3 mm |
| Dimensions (UP-250) | 270 × 245 × 116 mm |
| Power Supply | 220 V / 50 Hz |