Life Science Instruments
Filter
Showing 2431–2460 of 2769 results
| Brand | Tuo He |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SZ03-IID |
| Price | Upon Request |
| Exposure Time Range | 0–999.9 min / 0–999 min 59 s |
| Exposure Energy Range | 0–99.99 J |
| Chamber Dimensions | 340 mm × 260 mm × 150 mm |
| UV Wavelength Options | 254 nm (standard), optional 312 nm or 365 nm |
| UV Intensity | ≤5 mW/cm² |
| Lamp Configuration | 6 × 10 W low-pressure mercury lamps |
| Data Storage Capacity | 50 user-defined protocols |
| Display | 7-inch TFT color touchscreen |
| Safety Features | Interlocked safety door, UV-blocking viewing window, automatic UV shutoff upon door opening |
| Power Supply | 220 V, 50 Hz, 100 W |
| Net Weight | 13 kg |
| External Dimensions | 550 mm × 380 mm × 290 mm |
| Brand | Turtle |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ISO Digital |
| Sample Throughput | 1–12 samples (user-selectable) |
| Reaction Architecture | Fully Automated Digital Isothermal Amplification Platform |
| Droplet Generation Capacity | >20,000 droplets per run |
| Effective Droplet Yield | >95% |
| Droplet Uniformity | >99% |
| Quantification Method | Digital Endpoint Detection (dLAMP/dERA/dRPA compatible) |
| Run Time | 15–45 min |
| Automation Level | Integrated reagent mixing, droplet generation, incubation, and endpoint fluorescence imaging |
| Upgrade Path | Optional digital PCR (dPCR) module support |
| Brand | Taiwolkang |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TWK-DPH4 |
| Instrument Type | Semi-Automatic |
| Micromanipulator Axes | X, Y, Z |
| Positioning Resolution | 0.01 mm |
| Stimulus Control | Dual-mode (Single-Pulse & Cyclic Pulse) with Compensated Airflow |
| Signal Acquisition | High-Impedance Input, 16-bit ADC, Dual-Channel Adaptive Amplification |
| Software | Real-Time EAG Waveform Visualization, ΔV Peak Annotation, Export to Excel/PNG/SVG |
| Noise Performance | Low Thermal Drift Baseline, Adjustable Bandpass Filtering, Adaptive 50/60 Hz Notch + Wavelet Threshold Denoising |
| Compliance | Compatible with GC Trigger/Synchronization Signals (TTL), Faraday Cage Integration Required |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 38450 |
| Force Range | 0–1000 g |
| Force Resolution | 0.1 g |
| Observation System | Integrated Triangular Prism Viewing Platform |
| Data Storage | Onboard memory for >100 test sessions |
| Stimulus Control | User-adjustable ramp rate and inter-stimulus interval |
| Compliance | Designed for GLP-compliant rodent nociception studies |
| Accessories | Optional grip bar, mesh floor platform (5 × 5 mm² laser-cut apertures, 1 mm spacing), calibrated von Frey filament sets (37450/277, 0.008–300 g) |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 47302 (Rat) / 47303 (Mouse) |
| Speed Range | 3–100 m/min (1 m/min increments) |
| Incline Range | −25° to +25° (5° steps) |
| Electric Stimulus | 0–2 mA (0.1 mA resolution) |
| Channel Configuration | 3 lanes (rat, 45 × 11 cm each) / 6 lanes (mouse, 45 × 5.5 cm each) |
| Frame Height | 15 cm (rat) / 7 cm (mouse) |
| Belt Material | Food-grade polymer with optimized traction |
| Data Output | USB export (TXT, Excel, PDF) |
| Control Interface | 4.3" capacitive touchscreen |
| Software | Integrated acquisition & analysis suite with audit-ready metadata tagging, hierarchical result tree, customizable layout, and GLP-compliant session annotation |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 33 or 33T |
| Light Source Intensity Range | 0–250 (arbitrary units, ±1% accuracy) |
| Focal Spot Size | 4 × 6 mm |
| Reaction Time Resolution | 0.01 s |
| Preheating Temperature Range | 0–75 °C |
| Automatic Cut-off Timer | User-configurable |
| Data Output | RS-232 serial interface + thermal printer support |
| Compliance | Designed for GLP-compliant preclinical analgesia studies |
| Brand | 3P Innovation (UK) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Fill2Weight |
| Application Segment | Biopharmaceuticals |
| Compliance | FDA cGMP, EU GMP Annex 1, NMPA Sterile Manufacturing Guidelines |
| Material Construction | 316L Stainless Steel + Food-Grade Coating |
| Cleaning | CIP/SIP-Compatible |
| Particle Containment | <0.1 µg/m³ (OEL ≤1 µg/m³ compatible) |
| Dose Uniformity (CV) | ≤2.5% |
| Powder Size Range | 1–100 µm |
| Throughput (Commercial Mode) | >2000 units/min |
| Cleanroom Compatibility | ISO Class 5 (Grade A/B environments) |
| Brand | Unchained Labs |
|---|---|
| Origin | USA |
| Model | Junior-PVDS |
| Temperature Range | -20–120 °C |
| Dissolved Oxygen Range | 0–5 mg/L |
| pH Range | 1–14 |
| Vial Compatibility | 8–60 mm diameter |
| Max Tray Weight | 1000 g (including enclosure) |
| Hopper Capacity | Powdernium™: 10–100 mL |
| SV Dispenser | 4 mL |
| Dispense Volume | 10–10,000 µL |
| Viscosity Range (for viscous liquids) | 1–1000 cP |
| Balance Capacity | 220 g |
| Balance Sensitivity | 0.01 mg |
| Brand | Unchained Labs |
|---|---|
| Origin | USA |
| Model | Leprechaun |
| Application | Single-particle immuno-structural analysis of lentiviral vectors and extracellular vesicles (e.g., exosomes) |
| Detection Principle | Fluorescence-based single-particle imaging coupled with antibody- and probe-mediated orthogonal labeling |
| Sensitivity | ≥1 × 10⁷ particles/mL |
| Particle Sizing Range | ~30–200 nm (diameter) |
| Capture Flexibility | Compatible with anti-VSV-G, anti-gp70, or user-provided custom capture antibodies |
| Nucleic Acid Detection | RNA-specific fluorescent probes (e.g., Quasar 670-labeled oligos) |
| Structural Discrimination | Simultaneous detection of capsid protein (e.g., p24), envelope glycoprotein (e.g., VSV-G), and genomic RNA |
| Aggregation Assessment | Quantitative resolution of monodisperse virions vs. dimers, trimers, and higher-order aggregates |
| Regulatory Alignment | Designed to support process development under ICH Q5A(R2), USP <1043>, and FDA CMC guidance for gene therapy products |
| Brand | Unchained Labs |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Lunatic |
| Detection Time | 10 min per 96-well plate |
| Wavelength Accuracy | ±1 nm at ≤400 nm |
| BSA Detection Range | 0.02–275 mg/mL |
| DNA Detection Range | 1.5–13,750 ng/μL |
| Sample Types | Proteins, DNA, RNA, ssDNA, dsDNA, oligonucleotides |
| Sample Volume | 2 µL per well |
| Cuvette-Free Microfluidic Sample Handling | Yes |
| Plate Format | SBS-compliant 96-well microplate |
| Instrument Category | UV-Vis Microvolume Spectrophotometer for Biomolecular Quantification |
| Brand | Unchained Labs |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Sunscreen |
| Carrier Type | Lipid Nanoparticle (LNP) |
| Flow Rate Range | 0.1–30 mL/min |
| Maximum Flow Ratio | 5:1 |
| Sample Volume per Well | 400 µL – 2 mL |
| Brand | Unchained Labs |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Uncle |
| Instrument Principle | Differential Scanning Fluorescence (DSF) |
| Measured Parameters | Tm, Tagg, Tonset, Isothermal Stability, Viral Capsid Stability, Viral Genome Release Temperature, Dye-based Tm (DSF), Hydrodynamic Size & Polydispersity Index (PDI), Tsize, Tagg660, Thermal Refolding Assay, Viscosity, kD, B22, G22, ΔG |
| Sample Volume | 9 µL |
| Protein Concentration Range | 0.05–300 mg/mL |
| Temperature Control Range | 15–95 °C |
| Sample Capacity | 48 samples |
| Sample Introduction Method | Quartz Capillaries |
| 21 CFR Part 11 Compliance | Yes |
| Dimensions | 54 cm × 50 cm × 58 cm |
| Brand | Unisense |
|---|---|
| Origin | Denmark |
| Model | microrespiration |
| Detection Principle | Amperometric Microsensor-Based Closed-Circuit Respirometry |
| Measurement Range (O₂) | 0–500 µM |
| Current Resolution | 10⁻¹² A |
| Detection Limits | O₂: 0.3 µM |
| NO | 20–30 nM |
| Sample Volume Capacity | 0.5–8 mL (dual-port microrespiration vials) |
| Electrode Compatibility | O₂, H₂, H₂S, NO, N₂O, pH, Redox, Temperature, Flow, Diffusivity, NO₂⁻, NO₃⁻ |
| Signal Processing | Low-Noise Analog Amplification + 24-bit ADC Conversion |
| Compliance | GLP-Compatible Data Acquisition Architecture |
| Brand | UNITMA |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Quick-ray UT-06 |
| Spotting Method | Contact-based Manual Punching |
| Array Density | 1–300 cores per recipient block |
| Core Volume Capacity | 1–300 tissue cores |
| Spotting Time | 1–3 seconds per core |
| Slide/Plate Capacity | 120 / 90 / 60 / 30 / 20 positions (adjustable cassette trays) |
| Repeatability Accuracy | ±1 mm |
| Brand | Univercells Technologies (Belgium) |
|---|---|
| Origin | Belgium |
| Model | Scale-X™ hydro |
| Growth Surface Area | 2.4 m² |
| Configuration | Single-layer fixed-bed module |
| Construction Materials | Structured spiral-wound PET mesh and medical-grade silicone tubing |
| Sterilization | Pre-sterilized single-use disposable cartridge |
| Temperature Control | Ambient to 37 °C (external incubator required) |
| Application Scope | Adherent and suspension cell culture for R&D-scale vaccine and viral vector process development |
| Compliance | Designed for GLP-compliant process characterization |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | URE-2000 Series |
| Price Range | USD 42,000 – 70,000 |
| Scanning Throughput | 2 µm feature resolution |
| Resolution | 0.8 µm (with 2 µm positive photoresist) |
| Detection System Type | UV Optical Detection |
| Excitation Wavelength | 365 nm (i-line) |
| Emission Wavelength | 365 nm |
| Exposure Area | Up to 200 mm × 200 mm (URE-2000/A8) |
| Exposure Time Range | 0.1 s – 9999.9 s (programmable timer) |
| Mercury Lamp Power | 1000 W (DC, Osram Ultra-High-Pressure Hg Lamp) |
| Illumination Uniformity | ≤2.5% (Ø100 mm), ≤5% (Ø200 mm) |
| Alignment Accuracy | ±0.8 µm (single-side), ±2 µm (double-side, 0.8 mm wafer thickness) |
| Maximum Resist Thickness | 500 µm (SU-8, user-provided conditions) |
| Brand | URIT |
|---|---|
| Origin | Guangxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | BF-710 |
| Pricing | Upon Request |
| Brand | URIT |
|---|---|
| Origin | Guangxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | BF-730 |
| Price Range | USD 14,000 – 140,000 |
| Technology Platform | Analytical Flow Cytometry |
| Instrument Type | Benchtop Flow Cytometer |
| Primary Use Case | Life Science Research & Clinical Assay Development |
| Lasers | Up to 3 solid-state lasers — 405 nm (≥85 mW), 488 nm (≥50 mW), 638 nm (≥60 mW) |
| Optical Detection Channels | 14 fluorescence parameters + 1 FSC channel + 1 SSC channel |
| Coefficient of Variation (CV) | ≤2% (at peak resolution, using standard calibration beads) |
| Fluorescence Sensitivity | FITC ≤25 MESF, PE ≤15 MESF |
| Maximum Event Acquisition Rate | 65,000 events/second |
| Sample Introduction | Integrated automated autosampler with continuous flow rate control (5–120 µL/s) |
| Compensation Modes | Real-time automated compensation, manual on-instrument compensation, and offline compensation via analysis software |
| Brand | URIT |
|---|---|
| Origin | Guangxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | MS-3000 |
| Price Range | USD 14,000 – 115,000 |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | Analytik Jena GmbH (Germany) |
| Model | UVP Biospectrum Advanced 900 |
| Imaging Modality | Optical Bioluminescence & Fluorescence Imaging |
| Spectral Sensitivity Range | 405–810 nm |
| Field of View | 33.5 cm × 32 cm |
| Maximum Simultaneous Samples | 10 mice |
| Detector | −100 °C Cooled Back-Illuminated CCD |
| Lens | Fixed-focus f/0.95 lens |
| Integrated Temperature-Controlled Stage | Yes |
| Onboard Isoflurane Anesthesia Delivery | Yes |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures |
| Filter Customization | User-selectable excitation/emission filter sets |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | Analytik Jena |
| Country of Origin | Imported |
| Model | UVP GelSolo |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | UVP (a brand of Analytik Jena) |
| Model | UVP GelStudio PLUS Touch |
| Detection Modes | UV transillumination (302 nm), White light reflection, RGB fluorescence excitation (470/530/630 nm), Optional eLite full-spectrum LED excitation (365–740 nm) |
| Camera | Scientific-grade cooled CCD sensor with 16-bit digitization |
| Lens | Motorized f/1.4 macro lens with auto-focus and zoom |
| Safety | Interlocked UV chamber with automatic lamp shutoff, CE/UL certified |
| Compliance | Meets ISO 9001 manufacturing standards |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Imported |
| Model | UVP PCR Workstation / UVP PCR Enclosure |
| Pricing | Upon Request |
| Brand | VC Plasma |
|---|---|
| Type | Upright Ultra-Low Temperature Freezer |
| Operating Temperature | –86 °C |
| Available Capacities | 138 L, 228 L, 288 L, 350 L, 480 L, 580 L, 610 L, 710 L, 1000 L, 1200 L |
| Construction | 304 Stainless Steel Interior Tank & Inner Door |
| Refrigeration Circuit | High-Purity Copper Tubing |
| Power Supply | 220 V / 50 Hz |
| Origin | Guangdong, China |
| Distribution Model | Authorized Distributor |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | GDE |
| Heating Power | 900 W |
| Temperature Range | Ambient to 105 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Chamber | Transparent Polycarbonate (Max Temp: 105 °C) |
| Dimensions (W×H×D) | 413 × 295 × 410 mm |
| Weight | 6.2 kg |
| Water Requirement | Deionized Water Recommended |
| Stirring | Integrated Magnetic Stirrer |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Vetgenies 8 |
| Instrument Type | Veterinary Real-Time qPCR Platform |
| Nucleic Acid Extraction | Optional On-Device Lysis (Extraction-Free Workflow Supported) |
| Detection Chemistry | Dual-Channel SYBR Green I and Probe-Based (FAM/HEX) Fluorescence Detection |
| Thermal Cycling Accuracy | ±0.25 °C |
| Ramp Rate | Up to 5.0 °C/s |
| Reaction Volume | 10–50 µL |
| Throughput | 8 Samples per Run |
| Optical System | Integrated LED Excitation & Photodiode Detection |
| Data Output | Ct Values, Amplification Curves, Melting Curves, Qualitative/Quantitative Reports |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VIA capsule |
| Pricing | Available Upon Request |
| Brand | VibroniX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | UltraView MK-III |
| Instrument Type | Stimulated Raman Scattering (SRS) Microscope |
| Spectral Coverage | 500–3200 cm⁻¹ |
| Spatial Resolution | 350 nm |
| Imaging Speed | 10 FPS |
| Brand | VIYEE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ISTED Super-Resolution Microscope |
| STED Technology | Stimulated Emission Depletion |
| Excitation Laser Wavelengths | 405 nm / 488 nm / 561 nm (solid-state) / 640 nm |
| Resolution | Confocal Mode — Lateral 150 nm, Axial 300 nm |
| Field of View | 120 µm × 120 µm (with 100× oil immersion objective, NA ≥ 1.4) |
| Imaging Speed | 1 FPS at 512 × 512 pixels |
| Eyepieces | 10× wide-field |
| Objectives | 10×, 20×, 40×, 60× oil, 100× oil (NA ≥ 1.4) |
| Illumination | Transmitted LED ≥ 5 W |
| Detectors | ≥4 APD channels with ultra-low dark current and high photon detection efficiency |
| Scan Modes | X-Y, X-Y-T, X-Y-Z, X-Y-Z-T |
| Spectral Dispersion Accuracy | 10 nm |
| Stage | High-precision motorized stage (positioning accuracy < 0.7 µm) |
| Software Platform | Windows 10 Pro 64-bit, ≥64 GB RAM, ≥2 TB SSD |
| Image Acquisition & Analysis | 4-channel fluorescence imaging, up to 8192 × 8192 resolution, time-lapse acquisition, automated tile scanning, Z-stack acquisition, deconvolution, 3D reconstruction, AI-assisted cell segmentation, subcellular structure quantification, fluorescence co-localization analysis, interactive morphometric measurement |