Liquid Chromatograph
Filter
Showing 1–30 of 194 results
| Brand | AB SCIEX |
|---|---|
| Origin | Netherlands |
| Model | EKSPERT CHIPLC nanoLC 425 |
| Type | Nano-flow Liquid Chromatography System |
| Configuration | Used (Refurbished & Verified) |
| Intended Use | Analytical-scale and nano-scale LC separation for proteomics, metabolomics, and biomarker discovery |
| Brand | AB SCIEX |
|---|---|
| Origin | Singapore |
| Model | ekspert nanoLC 400 |
| Instrument Type | Nano-flow Liquid Chromatography System |
| Configuration | Pre-owned (Refurbished & Functionally Verified) |
| Flow Rate Range | 50 nL/min – 20 µL/min |
| Column Compatibility | 50–150 µm ID capillary columns |
| Detection Interface | ESI-compatible, designed for coupling with mass spectrometers (e.g., AB SCIEX TripleTOF®, QTRAP® systems) |
| Operating Software | ekspert microLC / nanoLC Control v3.x or later |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable software options |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Model | M3 MicroLC |
| Configuration | Refurbished Unit |
| Category | Microflow Liquid Chromatography System |
| Intended Use | Coupled with Mass Spectrometry (MS) for High-Sensitivity Bioanalysis |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PAH Analysis System |
| Instrument Type | Dedicated High-Performance Liquid Chromatography (HPLC) System |
| Application Scope | Specialized for Polycyclic Aromatic Hydrocarbons (PAHs) in Environmental Matrices |
| Configuration | Online Solid-Phase Extraction (SPE) coupled with HPLC and Fluorescence Detection (FLD) |
| Optional Upgrade Path | Online SPE–LC–MS/MS Interface Module |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | S3000 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | S6000 Comprehensive 2D-LC System |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose complex matrix analysis |
| Regulatory Compliance | Supports GB 5009.296–2023 and GB 5009.82–2016 for fat-soluble vitamins |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | S6000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 45 MPa / 62 MPa |
| Injection Volume | 100 µL (expandable to 1000 µL) |
| Data Acquisition Frequency | 160 Hz |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | S6000 Online SPE–2D-LC System |
| Instrument Category | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical platform for complex matrix samples |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | S6000PLUS |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical HPLC |
| Pump Configuration | Binary High-Pressure Gradient or Quaternary Low-Pressure Gradient Optional |
| Max Operating Pressure | 70 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Injection Volume | 0.1–30 µL (expandable to 100 µL) |
| Autosampler Capacity | 120 × 2 mL vials or 96-well microplate |
| Autosampler Temperature Control | 1–45 °C (Peltier-based, ±0.3 °C stability) |
| Column Oven Temperature Range | 1–90 °C (Peltier heating/cooling, ±0.1 °C uniformity) |
| Detector Options | UV, DAD (1024-pixel diode array), FLR, RI, ELS |
| DAD Specifications | Built-in Hg lamp wavelength calibration, 160 Hz acquisition rate, multi-channel reference background fitting, user-defined reference wavelengths per channel |
| Sample Carryover | <0.003% |
| Column Compatibility | Up to 300 mm length, ≥2.5 µm particle size columns |
| Integrated Column Switching Valve | Optional internal valve with up to 6-position configuration |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph |
| Maximum Operating Pressure | 150 MPa |
| Sample Capacity | 162 × 2 mL vials + 4 × 4 mL vials |
| Column Oven Temperature Range | 1.0–90.0 °C (0.1 °C resolution) |
| UV-Vis Detection Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 500 Hz |
| Detector Options | UV-Vis, Diode Array (DAD), Fluorescence (FLR), Refractive Index (RI), Evaporative Light Scattering (ELS) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH II |
| Instrument Type | Fast Liquid Chromatography (Flash) |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| Sample Injection Positions | 1–100 |
| Injection Volume Ratio | 1–10% |
| Temperature Control | 25°C (ambient, non-thermostatted) |
| Wavelength Range | 200–800 nm |
| Data Acquisition Frequency | Not specified (system supports real-time UV/VIS spectral scanning) |
| Brand | Agela |
|---|---|
| Model | LC-10F |
| Origin | Tianjin, China |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increment) |
| Max Operating Pressure | ≤ 42 MPa (316L stainless steel pump head) |
| Injection Capacity | Not specified |
| Column Oven Temperature Control | Not specified |
| UV-Vis Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU (254 nm, time constant = 1 s) |
| Baseline Drift | 1.5 × 10⁻⁴ AU/h (254 nm) |
| Flow Accuracy | ±0.5 % (at 1 mL/min, 10 MPa) |
| Flow Precision | RSD ≤ 0.1 % (at 1 mL/min, 10 MPa) |
| Pressure Pulsation | ≤ 0.5 % (at 1 mL/min, 10 MPa) |
| Detector Light Sources | Deuterium lamp (standard), Tungsten lamp (optional) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic HPLC System |
| Model | LC-10F |
| Instrument Type | Conventional Analytical HPLC |
| Flow Rate Range | 1–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Injection Volume Range | 1–20 µL |
| Wavelength Range | 200–800 nm |
| Data Acquisition Rate | Up to 60 Hz (programmable) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | LC2000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Max Operating Pressure | ≤70 MPa |
| Flow Accuracy | ±1% |
| Injection Volume Range | 0–100 µL (standard) |
| Sample Capacity | Vial tray & 96-well plate compatibility |
| Column Oven Temperature Range | 4–90 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Flow Precision (RSD) | ≤0.075% |
| Pressure Pulsation | ≤0.2 MPa or ≤1% |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Noise (UVD) | ±5 µAU |
| Baseline Drift (UVD) | 1×10⁻⁴ AU/h |
| Flow Cell Volume | 2.5 µL (5 mm path) / 13 µL (10 mm path) |
| Injection Carryover | <0.002% |
| Temperature Stability | ±0.1 °C |
| Column Compatibility | up to 300 mm length |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Multi-Stage Chromatographic Purification System |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) System |
| Configuration | Integrated Three-Stage Automated Purification Platform |
| Application Focus | Downstream Processing of Biologics, Natural Product Isolation, and Complex Matrix Sample Purification |
| Compliance Framework | Designed to support GLP-compliant workflows and scalable process development |
| Brand | Agela |
|---|---|
| Model | ZAM4000 |
| Detection Principle | Evaporative Light Scattering |
| Flow Rate Range | 1–50 mL/min |
| Nebulizing Gas Pressure | 3.5–5 bar |
| Nebulizing Gas Flow Rate | 1.7 L/min |
| Auxiliary Drying Gas Flow Rate | <2 m/min |
| Evaporator Temperature Range | Ambient to 85 °C |
| Light Source | Tungsten Lamp |
| Detector | Photomultiplier Tube (PMT) |
| Output Signal | 0–5 V Analog + RS-232 Digital |
| Power-Saving Mode | Enables independent shutdown of gas, lamp, heater, and PMT |
| Fault Monitoring | Real-time diagnostics for gas flow, heater, lamp, and PMT failure |
| 雾化气流控制 | Integrated electronic pressure controller for nebulizer gas |
| Auxiliary drying gas control | Built-in controller |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Third-Party Service Provider |
| Product Category | Imported Instrumentation |
| Model | Agilent 1100/1200/1360 HPLC 3Q Qualification Package |
| Price Range | USD 11,000–20,500 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Operating Pressure | 40 MPa |
| Flow Accuracy | < ±0.1% RSD |
| Injection Volume Range | 1–50 µL |
| Autosampler Tray Capacity | 100 positions |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent |
|---|---|
| Model | 1120 |
| Type | Compact Liquid Chromatograph (HPLC) |
| Pump Flow Rate Range | 0.001–10.0 mL/min (0.001 mL/min increments) |
| Flow Precision | ≤0.07% RSD |
| Autosampler Injection Volume | 0.1–100 µL (0.1 µL increments) |
| Injection Precision | <0.25% RSD (5–100 µL), <1% RSD (1–5 µL) |
| Sample Capacity | 100 × 2 mL vials or 2 × 40-position half-trays or 15 × 6 mL vials |
| Column Oven Temperature Range | 10 °C above ambient to 60 °C |
| Temperature Stability | ±0.15 °C |
| VWD Wavelength Range | 190–600 nm |
| VWD Noise | ±0.75 × 10⁻⁵ AU |
| Detector Compatibility | RID, FLD, ELSD |
| Software | EZChrom Elite Compact (English/Chinese/Japanese UI), LMD predictive diagnostics |
| Regulatory Support | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compliant operation |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1220 Infinity II |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical use in QA/QC and research laboratories |
| Flow Range | 0.2–10 mL/min |
| Injection Volume Range | 0.1–100 µL |
| Width | 370 mm |
| Pump Configuration | Isocratic or Binary Gradient Pump (optional Quaternary configuration) |
| Maximum Number of Temperature-Controlled Zones | 1 (with optional column oven) |
| Maximum Solvent Channels | 4 (with Solvent Selection Valve, SSV) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Column Oven Compatibility | Yes (optional) |
| Detector Options | Variable Wavelength Detector (VWD), Diode Array Detector (DAD), Refractive Index (RID), Fluorescence (FLD), Evaporative Light Scattering (ELSD), Mass Selective Detector (MSD) |
| Software Platforms | OpenLab CDS (ChemStation Edition, EZChrom Edition, or modern OpenLab CDS workstation) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Sustainability Certification | My Green Lab ACT Label (verified lifecycle environmental impact assessment) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 1260 Infinity II Bio-Inert |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | Universal for Biomolecular Analysis |
| Flow Rate Range | 0.2–10 mL/min |
| Maximum Pressure | up to 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Bio-SEC |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Biopharmaceutical Characterization |
| Flow Rate Range | Up to 10 mL/min (with G5654A Pump Module) |
| Injection Volume Range | 0.1–100 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1260 Infinity II GPC/SEC |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Polymer Characterization |
| Flow Rate Range | Up to 10 mL/min (G7110B Pump Module) |
| Maximum Operating Pressure | 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Temperature Control | Dual-Zone Column Compartment (G7116A/B) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 1260 Infinity II |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-purpose QC/QA, R&D, and routine analytical laboratories |
| Flow Rate Range | 0.2–10 mL/min |
| Maximum Pressure | 600 bar |
| Flow Precision | ≤0.07% RSD |
| Injection Volume Range | 0–100 µL |
| Sample Tray Capacity | 100 positions (expandable to 6144 via microtiter plates) |
| Column Oven Temperature Range | 4–80 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 80 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 1260 Infinity III Amino Acid Analysis System |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose amino acid analysis |
| Flow Rate Range | Up to 10 mL/min (G7111B pump module) |
| Maximum Operating Pressure | 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | 5 °C above ambient to 80 °C |
| Solvent Reservoir Capacity | 4 channels |
| Power Supply | 100–240 VAC |
| Dimensions (W × D × H) | 396 × 468 × 560 mm |
| Column ID Reader | Optional |
| Smart System Emulation | Not supported |
| ACT Certification | My Green Lab ACT certified for environmental accountability, consistency, and transparency |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 1260 Infinity III Bio-Inert LC System |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application | Universal for Biomolecular Analysis |
| Flow Rate Range | 0.2–10 mL/min |
| Maximum Operating Pressure | up to 600 bar |
| Injection Volume Range | 0.1–100 µL (0.1–1000 µL with Multi-Draw Kit, max 400 bar) |
| Solvent Channels | 4 (expandable to 15 with Solvent Selection Valve) |
| Column Temperature Zones | 2 (with G7116A) |
| Column ID Reader | Optional |
| Column Capacity | 4 |
| pH Range | 1–13 (short-term exposure to pH 14) |
| Salt Tolerance | up to 2 mol/L NaCl |
| Residual Carryover | <9 ppm |
| Power Supply | 100–240 VAC |
| Dimensions (W × D) | 435 × 468 mm |
| ACT Certification | Yes (My Green Lab ACT Label) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 1260 Infinity III |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical HPLC |
| Flow Rate Range | 0.05–5 mL/min (with G7112B Quaternary Pump) |
| Maximum Operating Pressure | 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 1260 Infinity III Method Development |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose |
| Flow Rate Range | up to 5 mL/min (with G7104C, G7112B) |
| Maximum Operating Pressure | up to 800 bar |
| Injection Volume Range | 0.1–100 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity III Multimethod |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical laboratory use |
| Flow Rate Range | up to 5 mL/min (with G7104C, G7112B modules) |
| Maximum Operating Pressure | 800 bar |
| Injection Volume Range | 0.1–100 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 1260 Infinity III Prime Bio LC |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | Up to 5 mL/min |
| Maximum Operating Pressure | Up to 800 bar |
| Injection Volume Range | 0.1–100 µL |
| Column ID Reader | Optional |
| Solvent Channels | 4 (integrated quaternary gradient valve) |
| Temperature Zones | 2 |
| Column Capacity | 4 |
| Bio-Compatibility | Yes |
| Power Supply | 100–240 VAC |
| ACT Certified | Yes (My Green Lab ACT Label) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Prime HPLC |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | up to 5 mL/min (with G7104C pump module) |
| Maximum Pressure | up to 800 bar |
| Injection Volume Range | 0.1–100 µL (extendable to 0.1–1500 µL with Multi-Draw Kit) |