| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LC2200 |
| Price | Upon Request |
| Pump Flow Range | 0.001–10.0 mL/min |
| Max Pressure | 6000 psi |
| Pump Accuracy | ±1% at 1 µL/min |
| Pump Precision | ±0.25% (0.1–10.0 mL/min) |
| UV Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | <6 nm |
| Baseline Noise | <±2×10⁻⁵ AU |
| Baseline Drift | <4×10⁻⁴ AU (p-p) |
| D₂ Lamp Lifetime | 3500 h (1000 h warranty) |
| UV Detector Output | 0.0005–4 AU/mV (chart recorder), 4 AU/V (data system) |
| Power Supply (Pump) | 85–264 VAC, 47–63 Hz, 60 W |
| Power Supply (UV Detector) | 100–240 VAC, 50–60 Hz, 80 W |
| Dimensions & Weight | Pump — 5.9 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC3000A Preparative Liquid Chromatograph |
| Max. Pressure (P3210) | 42 MPa |
| Max. Pressure (P3220) | 30 MPa |
| Flow Rate Range (P3210) | 0.001–9.999 mL/min |
| Flow Rate Range (P3220) | 0.01–49.99 mL/min |
| Flow Accuracy | ≤0.4% |
| Flow Precision (RSD) | ≤0.1% |
| UV/VIS Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ≤±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Absorbance Range | 0–2 AU |
| Absorbance Error | <±5% |
| Baseline Noise (254 nm) | ≤1.5×10⁻⁵ AU (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Baseline Drift (254 nm) | ≤4×10⁻⁴ AU/h (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Scan Modes | Programmable stop-and-go wavelength scanning (start/end λ and step size user-definable) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UP2000 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) with Online Solid-Phase Extraction (SPE) |
| Flow Rate Range | 0.001–20 mL/min |
| Maximum System Pressure | 25,000 psi |
| Autosampler Tray Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +10 °C to 150 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | LABA |
|---|---|
| Model | PC2001 |
| Origin | USA |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.01–100.00 mL/min |
| Maximum Pressure | 0–6000 psi |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–80 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Detector Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | Series 8000 |
| HPLC Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0–10 mL/min |
| Maximum Pressure | 9000 psi |
| Flow Precision | <0.1% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0–3 mL |
| Column Oven Temperature Range | (Ambient + 20°C) to 200°C |
| UV/Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 500 Hz |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HPLC 1500 Series |
| Price | Upon Request |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 6,000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.075% RSD |
| Gradient Precision | ±1% |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Range | D₂ Lamp (190–380 nm), W Lamp (366–800 nm) |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | HPLC 1500 |
| Flow Rate Range | 0.001–5 mL/min and 0.01–10 mL/min |
| Maximum Pressure | 6,000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.075% RSD |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Range | 190–380 nm (D₂ lamp), 366–800 nm (W lamp) |
| UV-Vis Detector Sensitivity | 0.0005–2.0 AUFS |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-2000 |
| Pricing | Available Upon Request |
| Maximum Pressure | 6000 psi |
| Flow Rate Range | 0.01–9.99 mL/min |
| Flow Accuracy | ±0.1% |
| Baseline Noise (UV-VIS) | 0.2 × 10⁻⁵ AU |
| Baseline Drift (UV-VIS) | 2 × 10⁻⁴ AU/hr |
| Pump Technology | SSI III Dual-Piston Positive Displacement with Patented Online Self-Cleaning Mechanism |
| Upgrade Path | Compatible with Second Pump for Binary Gradient Configuration |
| Detector Standard | Model 500 UV-Vis Variable Wavelength Detector (190–700 nm) |
| Software | LabAlliance Chromatography Data System (CDS) with Audit Trail & Electronic Signature Support per FDA 21 CFR Part 11 |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | PC-2000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 6000 psi |
| Sample Injection Positions | 120 |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 99 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | PC2001 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–20.000 mL/min (configurable for 10 mL/min or 80 mL/min total flow via pump head interchange) |
| Maximum Pressure | 6000 psi |
| Injection Positions | 120 |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Pressure Accuracy | ±1% of full-scale pressure |
| Flow Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Baseline Noise | <±1.0×10⁻⁵ AU |
| Baseline Drift | <2.0×10⁻⁴ AU/hr |
| Wavelength Accuracy | ±1.0 nm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | WA2002SF |
| Pricing | Available Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Model | LC600 Binary High-Pressure Gradient HPLC System |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | PC-controlled with audit trail capability (21 CFR Part 11 compliant configuration available) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC600 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Sample Loop Capacity | 2 mL (120-position tray) |
| Injection Volume Range | 1–250 µL |
| Column Oven Temperature Range | Ambient to 120 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 10 Hz |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0–50 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | ≤0.5% RSD |
| Sample Injection Volume | 0.1–100 µL |
| Injection Capacity | 120 positions (1.8 mL vials) |
| Column Oven Temperature Range | 5–80 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Pressure Pulsation (without damper) | <0.4% |
| Pressure Pulsation (with damper) | <0.015% |
| Detection Principle | UV-Vis absorbance with differential refractive index suppression and 40-mm optical path length flow cell |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical Use |
| Pump Configuration | Reciprocating Dual-Piston Isocratic or Binary High-Pressure Gradient Capable |
| Detector | UV-Vis with Variable Wavelength (VWL) Capability |
| Column Oven | PID-Controlled Temperature Regulation |
| Data Acquisition | 24-bit ADC, Low-Drift Preamp, Integrated Touchscreen Workstation (Audit Trail Optional) |
| Compliance Readiness | GLP/GMP-Aligned Architecture, FDA 21 CFR Part 11–Ready Software Framework |
| [Brand | LuNan RuiHong |
|---|---|
| Model | LC-1000D |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Operating Pressure | ≤ 42 MPa |
| Flow Precision | ≤ 0.1% RSD |
| Injection Volume Range | 0–30 µL |
| Column Oven Temperature Range | Ambient to 80 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Detector Type | Dual-Wavelength UV-Vis Photodiode Array (PDA)-Capable Optical System |
| Compliance | AIA/CDF File Support, GLP-Compliant Audit Trail, 21 CFR Part 11 Ready (Software-Configurable)] |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NP7001 |
| Price Range | USD 14,000–28,000 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) Pump |
| Flow Mode | Dual-Piston Serial Configuration |
| Flow Range | 0.001–9.999 mL/min |
| Flow Increment | 0.001 mL/min |
| Flow Accuracy | ≤0.5% or ≤10 µL/min |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.5 MPa |
| Maximum Operating Pressure | ≤42 MPa |
| Tubing Connection | 1/16″ Stainless Steel Standard Fittings |
| Display | 4.7″ LCD (320 × 240 pixels), Tab-Based UI |
| User Programs | 10 Predefined Methods |
| Gradient Capability | Linear Flow Gradient Programming |
| Communication Protocol | Open ASCII-Based RS-232/RS-485 Protocol (Third-Party Software Compatible) |
| Maintenance Feature | Optional Automatic Back-Flush Mechanism for Piston Seal and Rear Seal Area |
| Sealing Architecture | Floating Piston Design with Extended Seal Life |
| Flow Damping | Integrated Electronic Pulse Damping Control |
| Calibration | Multi-Point Flow Calibration Curve (Spanning Full Range) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-4000 |
| Pricing | Upon Request |
| Flow Rate | 0.01–20 mL/min |
| Maximum Pressure | 0.0–6000 psi |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Baseline Drift | ≤2 × 10⁻⁴ AU/h |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC4006 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 10,000 psi |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient +10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Flexar |
| Instrument Type | Fast Liquid Chromatograph |
| Flow Rate Range | 1.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Loop Capacity | 1.5 mL (100-position tray) |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FLEXAR™ |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Pump Configuration | Dual Binary Solvent Delivery |
| Maximum Pressure Rating | >18,000 psi |
| Integrated Piston Wash Function | Yes |
| Real-Time Pressure Monitoring | Supported via Chromera CDS |
| Gradient Delay Volume | Minimized for UHPLC compatibility |
| Column Oven Temperature Range | Ambient to 90 °C (optional extension to 110 °C) |
| UV-Vis Detector Wavelength Range | 190–900 nm (with optional diode array) |
| Data Acquisition Rate | Up to 100 Hz |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready architecture |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC 300 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) / High-Performance Liquid Chromatograph (HPLC) |
| Pressure Rating Options | 10,000 psi (HPLC mode) or 18,000 psi (UHPLC mode) |
| Detector Options | PDA, Multi-Channel UV/Vis, Single-Channel UV/Vis, Fluorescence, Refractive Index |
| Software Platform | Simplicity™ Chrom CDS |
| Gradient Accuracy | <0.2% RSD |
| System Dispersion Volume | <12 µL (typical, full system configuration) |
| Autosampler Features | Integrated color touchscreen display, programmable sample cooling (4–40 °C), low carryover (<0.005%) |
| Column Oven Temperature Range | 5–90 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | L820 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical HPLC |
| Price Range | USD 56,000 – 84,000 (FOB Beijing) |
| Compliance | GLP/GMP, FDA 21 CFR Part 11, Chinese Pharmacopoeia 2020 Edition, Chinese Veterinary Pharmacopoeia 2020 Edition |
| Brand | Prin-Cen |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | ELSpe-2 |
| Pricing | Upon Request |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 50 MPa |
| Autosampler Capacity | 120 positions × 2 mL vials |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 60 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 50 Hz |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QT-330 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Accuracy at 50 °C | ±0.1 °C |
| Repeatability | ±0.1 °C |
| Heating Chamber Dimensions | 350 mm × 45 mm × 40 mm |
| Display | Dual-line LED with Touch-sensitive Controls |
| Safety Features | Over-temperature Alarm & Auto Cut-off |
| Mounting | Magnetic-latch Lid & Dual Orientation (Vertical/Horizontal) |
| Viewing Window | Integrated Tempered Glass Panel |
| Column Capacity | 1–2 Standard HPLC Columns |
| Brand | Restek |
|---|---|
| Origin | USA |
| Product Lines | Allure® C18, Allure® Basix, Allure® PFP Propyl, Allure® Biphenyl, Ultra C18, Ultra Aqueous C18, Ultra IBD, Kromasil® C18, Viva Wide Pore C18, Pinnacle™ II C18, Pinnacle™ DB C18 |
| Column Dimensions | 50 mm, 150 mm, 250 mm (length) |
| Particle Sizes | 3 µm & 5 µm |
| Catalog Numbers | e.g., 9214352-712, 9414565-712, 9178575-712, etc. |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROXY |
| Pricing | Available Upon Request |
| Potentiostat | ROXY Potentiostats DCC |
| Autosampler | AS 110 (Cool, Micro, 10-Position Vial) |
| LC Pump | LC 110 |
| Reactor Cell | Integrated with Multi-Electrode Detection (MD) and Gas Collection (GC) Electrodes |
| Organizer | OR 110 |
| Software | Clarity Chromatography Data System |
| Brand | Sanotac |
|---|---|
| Model | ELSD-6000 |
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | HPLC-Compatible Evaporative Light Scattering Detector |
| Flow Rate Range | 0.01–3 mL/min |
| Max Operating Pressure | 1 bar |
| Sample Injection Positions | 1 |
| Injection Volume Range | 1 µL–100 µL (system-dependent) |
| Drift Tube Temperature Range | Ambient to 150 °C (1 °C increment) |
| Nebulizer Temperature Range | Ambient to 50 °C (1 °C increment) |
| Light Source | 650 nm, 30 mW Semiconductor Laser |
| Photodetector | Photomultiplier Tube (PMT) |
| Data Acquisition Rate | 20 Hz |
| Baseline Noise | ≤ 0.03 mV |
| Baseline Drift | ≤ 0.3 mV / 60 min |
| Quantitative Reproducibility (RSD) | ≤ 2% |
| Minimum Detectable Mass | < 1 ng |
| Typical Linear Quantitation Range | 0.1–30 µg |
| Gas Supply | Clean, oil-free air or nitrogen |
| Gas Pressure Range | 2–5 bar |
| Gas Flow Control | Mass Flow Controller, accuracy ≤ ±1% or ±0.02 L/min |
| Gain Adjustment | Linear, 0.3–30× continuous |
| Analog Output | –1200 to +1200 mV |
| Digital Interfaces | RS-232, USB, LAN (TCP/HTTP), programmable external event I/O |
| Power | 85–264 VAC, 50 Hz |
| Dimensions (W×H×D) | 260 × 190 × 460 mm |
| Weight | 10 kg |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ELSD9000 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Conventional HPLC-Compatible Detector |
| Flow Rate Range | 0.01–3 mL/min |
| Max Operating Pressure | 1 bar |
| Sample Injection Port | Single-channel |
| Injection Volume Range | Not applicable (flow-through detector) |
| Temperature Control Range | Ambient to 150 °C (1 °C step resolution) |
| Light Source | 650 nm, 30 mW laser diode |
| Data Acquisition Rate | 20 Hz (digital output), 100 Hz (internal sampling) |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Pressure | 42 MPa |
| Flow Accuracy | ±1% |
| Flow Precision | ±0.5% |
| Injection Volume Options | 2 mL (108-position) or 4 mL (70-position) |
| Column Oven Temperature Range | Ambient +5 °C to 80 °C |
| Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |