Liquid Chromatograph
Filter
Showing 91–120 of 358 results
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | EClassical 3200 |
| Price Range | USD 14,000 – 56,000 (FOB) |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Column Oven Temperature Control Range | 4–85 °C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | EClassical 3200 |
| Price Range | USD 14,000–43,000 (FOB) |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical chromatography |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 90 MPa |
| Autosampler Capacity | Not integrated (manual injection only) |
| Injection Volume Range | Not specified (compatible with standard 10–100 µL fixed-loop or syringe-based manual injectors) |
| Column Oven Temperature Control | Not built-in (external oven required for temperature-sensitive separations) |
| UV-Vis Detection Wavelength Range | Detector not included in base configuration (requires optional UV/Vis or PDA detector module) |
| Data Acquisition Frequency | Dependent on connected detector and software sampling settings |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fast Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Column Oven Temperature Range | 5–85 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 2–40 Hz |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | EClassical 3200L |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Injection Volume Range | 0.1–100 µL (standard configuration) |
| Column Oven Temperature Range | Ambient +5°C to 85°C |
| UV-Vis Wavelength Range | 190–800 nm |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | EClassical3200 |
| Price Range | USD 14,000 – 56,000 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-purpose analytical use |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Column Oven Temperature Control Range | 4–85 °C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LIFD230 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Category | Conventional High-Performance Liquid Chromatography (HPLC) Detector |
| Application Scope | General-purpose analytical detection in life sciences, environmental analysis, and pharmaceutical QC/QA |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Conventional HPLC System |
| Gradient Configuration | Quaternary Low-Pressure Mixing |
| Flow Range (Analytical) | 0.001–10 mL/min |
| Flow Range (Semi-Preparative) | 0.01–100 mL/min |
| Flow Accuracy | ±3% (Analytical), ±5% (Semi-Preparative) |
| Mixer Volume | 800 µL |
| Display | 4-digit LED |
| Communication Interface | RS232 or USB |
| Detector | Diode Array Detector (DAD) |
| System Architecture | Fully Computer-Controlled, Integrated Online Degasser |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | P1000 |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) System |
| Application Scope | General-purpose preparative chromatography |
| Flow Rate Range | 0–1000 mL/min |
| Maximum Operating Pressure | 0–7 MPa |
| Flow Accuracy | ≤ ±3% |
| Flow Precision (RSD) | ≤ 1% |
| Drive Motor | Brushless DC Servo Motor |
| Pump Head | Dual-piston Reciprocating Design |
| Communication Interface | RS-485 |
| Pressure Units | MPa / psi / bar (selectable) |
| Pressure Monitoring | Real-time display with over-pressure alarm and user-defined upper/lower limits |
| Flow Compensation | ±15% adjustable compensation range |
| Control Mode | Full computer reverse control via external workstation |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | P1201 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +5°C to 160°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 20 Hz |
| Brand | Elite |
|---|---|
| Model | P230 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Flow Precision | RSD < 0.3% (0.001–4.999 mL/min), RSD < 0.5% (5.000–9.999 mL/min) |
| Max Operating Pressure | 40 MPa (≤4.999 mL/min), 20 MPa (>5.000 mL/min) |
| Wavelength Range | 190–400 nm (D₂ lamp), 190–720 nm (D₂ + W lamp) |
| Baseline Noise | ≤±5.0×10⁻⁵ AU (empty cell, 254 nm, 1.0 s) |
| Baseline Drift | ≤±5.0×10⁻⁴ AU/hr (empty cell, 254 nm, 60 min equilibration) |
| Detector Options | UV230 (UV-Vis), DAD230 (PDA), RI230 (RI), AS230 (autosampler), DG230 (online degasser), LU230 (low-pressure gradient mixer), EC2000 series workstations |
| Compliance | Designed for GLP/GMP environments |
| Sample Compatibility | Compatible with reversed-phase, normal-phase, ion-exchange, size-exclusion (GPC), and amino acid (AAA) chromatography configurations |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | P230II |
| Price Range | USD 14,000 – 28,000 (approx.) |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Maximum Operating Pressure | 42.0 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +5°C to 85°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 20 Hz |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | P230p |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) Pump |
| Application Scope | General-Purpose Preparative & Analytical LC |
| Flow Rate Range | 0.01–40.00 mL/min |
| Maximum Operating Pressure | 30 MPa (at 0.01–20.00 mL/min) |
| Flow Precision | RSD < ±1.0% |
| Flow Accuracy | ±0.2% (measured at 10.00 mL/min, 8.5 MPa, water, 25 °C) |
| Pressure Display Error | ≤ ±3% |
| Pressure Pulsation | ≤ 1.0% |
| Power Supply | 220 V, 50 Hz |
| Dimensions (W×D×H) | 420 × 280 × 175 mm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Melamine-Specific HPLC System |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Melamine Quantification in Food & Feed Matrices |
| Wavelength Range | Not Applicable (Fixed 240 nm UV Detection per Standard Method) |
| Data Acquisition Rate | Not Specified |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | Rubikstation |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Column Oven Temperature Range | 4–85 °C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Brand | EXFORMMA |
|---|---|
| Origin | Hong Kong |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Model | EX1800 Ultra-High-Performance Liquid Chromatography (uHPLC) Analytical System |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph |
| Solvent Inlet Configuration | Dual 2-position/2-way switching valves enabling four independent solvent channels |
| Degasser Channel Volume | 380 µL |
| Pump Type | Dual-plunger reciprocating parallel pump with integrated binary high-pressure mixer |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | ≤ ±0.3% |
| Flow Precision (RSD) | < 0.06% at 1 mL/min and 10 MPa |
| Pressure Pulsation | ≤ 0.1 MPa |
| Power Supply | 220 V AC / 110 V AC |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | FlashDoctor-1500 |
| Instrument Type | Medium-Pressure Flash Chromatography System |
| Application Scope | General-Purpose Preparative Purification |
| Flow Rate Range | 0–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| Flow Accuracy | ±1.5% |
| Injection Capacity | Manual or Optional Autosampler |
| Injection Volume Range | 0.1–50 mL (via syringe or loop) |
| Temperature Control | Ambient-only (no active column oven) |
| Wavelength Range (DAD) | 200–800 nm |
| Data Acquisition Rate | Up to 20 Hz |
| Brand | Axcend |
|---|---|
| Origin | USA |
| Model | Focus LC |
| Instrument Type | Portable Capillary HPLC |
| Detection Principle | UV Absorbance (254 nm standard) |
| Max Operating Pressure | 10,000 psi |
| Power Input | AC 100–240 V, 50/60 Hz, 1.4 A |
| Battery | 12 V DC, 126 Wh LiFePO₄ |
| Runtime | >10 hours per charge |
| Cycle Life | >2,000 charge/discharge cycles |
| Solvent Consumption | <10 mL/week (typical operational use) |
| Cartridge-Based System | Tool-free, modular hardware reconfiguration |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose LC Analysis |
| Model | L75 |
| Pricing | Upon Request |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | LC5090Plus |
| Pricing | Upon Request |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Use |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LC5190 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Analytical Instrument |
| Flow Rate Accuracy | ≤0.1% RSD |
| Pressure Range | Up to 60 MPa |
| Wavelength Range (UV Detector) | 190–900 nm |
| Injection Volume Precision | ±0.1 µL |
| Column Temperature Control Range | 5–85 °C (with cooling & heating) |
| Detection Modes Supported | UV-Vis, DAD, FL, ELSD, RI |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC 3000 |
| Pricing | Upon Request |
| [Brand | Golden Promise |
|---|---|
| Model | LC-3000 |
| Pump Type | Dual-plunger reciprocating high-pressure gradient system |
| Max Pressure | 42 MPa (P3110), 30 MPa (P3120) |
| Flow Range | 0.002–9.998 mL/min (P3110), 0.01–49.99 mL/min (P3120) |
| Flow Accuracy | ±2% (2–5% of set flow, MeOH/H₂O 80:20) |
| Flow RSD | <0.1% |
| Detector | UV/VIS (UV3000) |
| Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Scan Modes | Programmable stop-flow scanning (start/end/step configurable) |
| Absorbance Range | 0–2 AU |
| Baseline Noise | 2×10⁻⁵ AU/h (1 mL/min, MeOH/H₂O 80:20, 254 nm) |
| Baseline Drift | 15×10⁻⁵ AU/h (1 mL/min, MeOH/H₂O 80:20, 254 nm) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Lamp Options | Deuterium (standard), Tungsten (optional) |
| Display | 320×240 dot-matrix LCD with adjustable blue backlight |
| Communication | RS-232 interface |
| Power | 220 V ±10%, 50 Hz (pump: 400 W |
| detector | 60 W) |
| Dimensions (D×H×W) | 398×149×267 mm |
| Weight | 14 kg |
| GLP Features | Lamp operating time logging, lamp cycle count, lamp replacement history, serial number traceability] |
| [Brand | Golden Promise |
|---|---|
| Model | LC-3000 |
| Type | HPLC-Based Melamine Quantification System |
| Origin | Shandong, China |
| Instrument Class | Benchtop Liquid Chromatograph for Targeted Small-Molecule Analysis |
| Detection Principle | UV-Vis Absorption at 240 nm with Diode Array or Fixed-Wavelength UV Detector |
| Column Compatibility | Reversed-Phase C8/C18 (e.g., 250 mm × 4.6 mm, 5 µm) |
| Flow Rate Range | 0.1–2.0 mL/min |
| Column Oven Temperature Control | Ambient to 60 °C |
| Sample Injection Volume | 5–100 µL (manual or optional autosampler-ready) |
| Regulatory Alignment | Designed for ASTM D7968-19, ISO 17394:2015, and GB/T 22388–2008 compliant workflows |
| Software | PC-based chromatography data system (CDS) with peak integration, calibration curve generation (linear/non-linear), audit trail, and report export (PDF/CSV)] |
| Brand | HAMILTON |
|---|---|
| Stationary Phase | PSDVB/Trimethylammonium |
| Mode | Anion Exchange |
| Particle Size | 10 µm |
| Pore Size | 100 Å |
| Inner Diameter | 4.1 mm |
| Length | 250 mm |
| Housing Material | Stainless Steel |
| Max. Pressure | 5,000 psi |
| Exchange Capacity | 0.304 meq/column |
| pH Stability Range | 1–13 |
| Mobile Phase Compatibility | 0–100% aqueous/organic (e.g., methanol, acetonitrile) |
| Temperature Limit | 60 °C (at pH 1–7), 50 °C (at pH 8–13) |
| Regeneration Protocol | 50 mL methanol + 1% v/v 6 N HNO₃ |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Injection Positions | 1 |
| Injection Volume Range | 0–50 µL |
| Temperature Control | Ambient Only |
| Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | NS4201 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-purpose analytical and preparative-scale development |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | RSD ≤ 0.1% |
| Injection Mode | Manual injection valve (standard) |
| Injection Volume Range | 0–20 µL |
| Column Oven Temperature Control | Ambient only (no active temperature control) |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 5 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ChromAssist Database Edition |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) System Software |
| Deployment Options | Standalone & Networked |
| Regulatory Compliance | FDA 21 CFR Part 11, ALCOA+ Principles, ISO/IEC 17025 Annex A.3, ICH GCP, USP <1058> Analytical Instrument Qualification |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min at ≤40 MPa |
| Maximum Operating Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Sample Injection Positions | 200 |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | (Ambient −15 °C) to 85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan (manufactured by Hitachi High-Tech Corporation) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min at ≤40 MPa |
| Maximum Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Injection Volume Range | 0.1–100 µL |
| Autosampler Capacity | 200 positions |
| Column Oven Temperature Range | (Ambient −15 °C) to 85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Product Type | Imported Instrument |
| Model | ChromasterUltra Rs |
| Instrument Category | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.001–2.5 mL/min |
| Maximum System Pressure | 140 MPa |
| Flow Precision | ≤0.06% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–20 µL |
| Column Oven Temperature Range | (Ambient −15 °C) to 90 °C |
| UV-Vis Wavelength Range | 100–900 nm |
| Data Acquisition Rate | 100 Hz |