Liquid Chromatograph
Filter
Showing 181–210 of 358 results
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC2200 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Profile | Dedicated-Use Analytical Instrument |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Maximum Operating Pressure | 42 MPa |
| Detector Wavelength Range | 190–700 nm (D₂ + W lamp) |
| Baseline Noise | ≤1×10⁻⁵ AU |
| Baseline Drift | ≤1.5×10⁻⁴ AU/hr |
| Flow Accuracy | ≤±1% |
| Flow Precision | ±0.5% |
| Flow RSD | ≤0.1% |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Detection Range | 0–3 AU |
| Flow Cell Volume | 10 µL |
| Time Constant | 16-step adjustable |
| Auto-Zero | Full-scale |
| Brand | Sanotac |
|---|---|
| Model | Pilot Series |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–100.00 mL/min (gradient) |
| Max. Operating Pressure | 30 MPa |
| Injection Volume | 1–20 mL |
| Column Temperature Control | 0–80 °C |
| UV Detection Wavelength Range | 190–800 nm (dual-wavelength simultaneous detection) |
| Data Acquisition Frequency | 10 Hz |
| Detector Wavelength Accuracy | ±1 nm |
| Absorbance Range | 0–2 AU |
| Gradient Types | Step, Linear, Real-time Adjustable |
| Flow Accuracy | ±0.5% |
| Pressure Pulsation | ≤0.2 MPa |
| Pump Material Options | 316L Stainless Steel, PEEK, Titanium, Hastelloy |
| Fraction Collector | Auto, 2 × 60 positions (Φ15 mm × 150 mm tubes), multiple collection modes |
| Software Compliance | Fully compliant with CFDA GxP and FDA 21 CFR Part 11 (audit trail, electronic signature, role-based access control, database-driven project management) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Echo MS |
| Instrument Type | Ultra-High-Throughput Direct-Infusion Mass Spectrometry System |
| Application Scope | Universal Quantitative Bioanalysis |
| Regulatory Context | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11-compliant data management frameworks |
| Sample Introduction Method | Contactless Acoustic Droplet Ejection (ADE) coupled to triple quadrupole mass spectrometry |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX 7500 |
| Instrument Type | Rapid Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS) |
| Configuration | Triple Quadrupole with QTRAP®-Ready Architecture |
| Flow Rate Compatibility | 1 µL/min to 3 mL/min |
| Polarity Switching Speed | ≤5 ms |
| Dynamic Range | 6 decades (linear) |
| Software Platform | SCIEX OS |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | 7600 |
| Instrument Type | High-Resolution Hybrid Quadrupole Time-of-Flight Mass Spectrometer (QTOF) with Integrated LC Compatibility |
| Application Scope | Universal for Biomolecular Characterization and Small-Molecule Structural Elucidation |
| Ionization Modes | ESI, APCI (optional) |
| Fragmentation Technology | Electron-Activated Dissociation (EAD) |
| Sensitivity Enhancement | Zeno Trap™ Ion Accumulation Technology |
| MS/MS Scan Rate | Up to 133 Hz |
| Duty Cycle | >90% Ion Injection Efficiency into TOF Analyzer |
| Mass Accuracy | <2 ppm (internal calibration), <5 ppm (external calibration) |
| Mass Resolution | ≥35,000 FWHM (at m/z 1,000) |
| Dynamic Range | >4 orders of magnitude |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Compass CDS |
| Price Range | USD 35,000 – 85,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Injection Positions | 100 × 2 mL vials |
| Injection Volume | 0.1–50 µL (standard), 5–2250 µL (optional) |
| Column Oven Temperature Range | Ambient to 85 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC6000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose analytical platform |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Operating Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Autosampler Capacity | 200 positions (1.5 mL vials) |
| Optional Configurations | 128 positions (4 mL vials) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Wavelength Ranges | UV-Vis: 190–900 nm |
| DAD | 190–900 nm |
| Fluorescence (FL) | Ex 200–850 nm / Em 250–900 nm |
| Data Acquisition Rate | Multi-step selectable |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC6000-DAD |
| Instrument Category | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical platform |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure Rating | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional Trays | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| DAD Wavelength Range | 190–900 nm |
| Spectral Acquisition Rate | Multi-step adjustable |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic UHPLC System |
| Model | LC6000-FLD |
| Instrument Type | Ultra-High Performance Liquid Chromatograph with Fluorescence Detection |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Excitation Wavelength Range | 200–850 nm |
| Emission Wavelength Range | 250–900 nm |
| Data Acquisition Frequency | Multi-step adjustable |
| Brand | Santai |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Ultra-High-Performance Preparative LC System |
| Flow Rate Range | 1–150 mL/min |
| Maximum Operating Pressure | 40 MPa |
| Flow Accuracy | ±1% |
| Injection Volume Range | 100 µL–5 mL |
| Sample Tray Capacity | 112 × 5 mL, 72 × 9 mL, 50 × 15 mL, 6 × 40 mL |
| UV-Vis Wavelength Range | 200–800 nm |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | LC-3000 (Dual-Pump Configuration) |
| Flow Rate Range | 0.001–10.000 mL/min (0.001 mL/min increment) |
| Maximum Pressure | 40 MPa |
| Flow Accuracy | <0.1% RSD |
| Injection Volume Range | 1–50 µL |
| Sample Tray Capacity | 100 positions (1.5 mL vials) or 80 positions (4 mL vials) |
| Column Oven Temperature Range | Ambient +10°C to 60°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | LC-3000 |
| Flow Rate Range | 0.001–10.000 mL/min (0.001 mL/min increment) |
| Maximum Pressure | 40 MPa |
| Flow Accuracy | RSD ≤ 0.3% (at 1 mL/min) |
| Flow Precision | RSD ≤ 0.1% (at 1 mL/min) |
| Injection Volume | 1–50 µL |
| Sample Tray Capacity | 100 positions × 1.5 mL vials or 80 positions × 4 mL vials |
| Column Temperature | Ambient (no active oven) |
| Wavelength Range | 190–700 nm (±2 nm accuracy) |
| Data Acquisition Rate | 24 Hz |
| Detector Noise | ≤1.5 × 10⁻⁵ AU/h (254 nm, MeOH/H₂O 80/20, 1 mL/min) |
| Baseline Drift | ≤4 × 10⁻⁴ AU/h (254 nm, same conditions) |
| Lamp Source | Deuterium lamp (standard), Tungsten lamp (optional) |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | LC1620 |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Operating Pressure | 45 MPa |
| Autosampler Capacity | 80 positions |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | Ambient +10°C to 60°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CTO-10AVP |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Essentia LC-15C |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | Essentia LC-16 Carbamate Post-Column Derivatization System |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application | Dedicated Analytical System for Carbamate Pesticide Residues |
| Flow Rate Range | 0.001–10.00 mL/min |
| Maximum Pressure | 40 MPa |
| Flow Accuracy | ≤0.06% RSD or ≤0.02 min SD |
| Autosampler Capacity | 108 positions |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 150 °C |
| Fluorescence Detector Wavelength Range | Excitation (Ex): 200–750 nm |
| Emission (Em) | 200–750 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Domestic |
| Model | LC-16 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 36 MPa |
| Sample Tray Capacity | 108 positions for 1.5 mL vials + support for 4.0 mL vials |
| Injection Volume Range | 0.1–100 µL (expandable to 2000 µL with optional syringe) |
| Column Oven Temperature Range | 14–60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Essentia LC-16 Post-Column Derivatization System for Aflatoxin Analysis |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application | Dedicated Aflatoxin B & G Analysis |
| Flow Rate Range | 0.001–10.00 mL/min |
| Maximum Pressure | 40 MPa |
| Flow Precision | ≤0.06% RSD or ≤0.02 min SD |
| Autosampler Capacity | 108 positions |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | (Ambient +10)–150 °C |
| Fluorescence Detector Excitation/Emission Wavelength Range | 200–750 nm / 200–750 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Product Type | Imported Instrument |
| Model | i-Series LC-2070 / LC-2080 |
| Instrument Category | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Maximum Pressure | 50 MPa (LC-2070) / 70 MPa (LC-2080) |
| Flow Accuracy | < 0.06 % RSD or < 0.02 min SD |
| Sample Capacity | 336 positions (1 mL vials), 216 positions (1.5 mL vials), 112 positions (4 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | 12 °C below ambient to 90 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LabSolutions MD |
| Instrument Category | Conventional High-Performance Liquid Chromatography (HPLC) System Software |
| Application Scope | General-Purpose Analytical Method Development for HPLC/UHPLC |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-10A |
| Instrument Type | High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.05–5 mL/min at 600 bar |
| Maximum Pressure | 600 bar |
| Injection Volume Range | 0.1–100 µL (0.1 µL increment), expandable |
| Column Oven Temperature Range | 4–80 °C (standard) |
| UV-Vis Detector Wavelength Range | 190–600 nm |
| Baseline Noise | ≤ ±0.35 × 10⁻⁵ AU |
| Baseline Drift | ≤ ±2 × 10⁻⁴ AU/h |
| Data Acquisition Rate | down to 0.6 µAU/cm |
| Gradient Accuracy | ±1% (0–100%, water/acetone binary gradient) |
| Flow Precision | ≤ 0.1% RSD |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Quaternary Gradient HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 50 MPa |
| Autosampler Capacity | 10 positions |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | Ambient +5°C to 80°C |
| UV Detection Wavelength Range | 180–700 nm |
| Data Acquisition Rate | Up to 120 Hz |
| Compliance | ASTM D4327, ISO 17025-aligned operation, USP <621>, FDA 21 CFR Part 11-ready software environment |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2010CHT |
| Instrument Type | Fast HPLC System |
| Flow Rate Range | 0.001–5.0 mL/min |
| Max Operating Pressure | 35.0 MPa |
| Autosampler Capacity | 350 × 1 mL vials (standard) |
| Injection Volume Range | 0.1–100 µL (standard), up to 2000 µL (optional) |
| Column Oven Temp Range | 4–60 °C (with active cooling) |
| UV-VIS Wavelength Range | 190–600 nm |
| Data Acquisition Rate | Up to 50 Hz (configurable) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2010CHT |
| Instrument Type | Fast HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Capacity | 100 × 4.0 mL vials |
| Injection Volume Range | 0.1–50 µL (standard) |
| Column Oven Temperature Range | (Ambient + 10)–60 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2030 |
| Instrument Type | Fast HPLC System |
| Max. Operating Pressure | 44 MPa |
| Autosampler Capacity | 100 positions |
| Column Oven Temperature Range | Ambient +10°C to 80°C |
| UV-Vis Wavelength Range | 190–700 nm (with SPD-M30A or SPD-20A VWD) |
| Data Acquisition Rate | Up to 125 Hz |
| Software Platform | LabSolutions (v5.9x or later) |
| Compliance | ASTM D7260, ISO 17025, USP <621>, FDA 21 CFR Part 11 (with audit trail enabled) |
| Detector Options | Variable Wavelength Detector (VWD), Photodiode Array Detector (PDA), Fluorescence Detector (RF-20Axs), Refractive Index Detector (RID-20A) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2030 |
| Instrument Type | Fast HPLC |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Position Capacity | 1.5 trays (standard 100 × 2 mL vials per tray) |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Control Range | +10 to +60 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Shimadzu LC-20A |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC-capable) |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Tray Capacity | 100 positions (1.5 mL vials) |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | (Ambient −10 °C) to 60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-20A |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Injection Volume | 1–50 µL |
| Injection Vial Capacity | 1.5 mL |
| Column Oven Temperature Range | Ambient +10°C to 60°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Method Scouting System |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | Not Applicable (System-Level Automation Platform) |
| Maximum Pressure Rating | Not Applicable |
| Autosampler Positions | Not Applicable |
| Injection Volume Range | Not Applicable |
| Column Oven Temperature Range | Not Applicable |
| UV/VIS Wavelength Range | Not Applicable |
| Data Acquisition Frequency | Not Applicable |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nexera FV |
| Instrument Type | Ultra-High-Performance Liquid Chromatography (UHPLC)-Coupled Dissolution Testing System |
| Flow Rate Range | 0.0001–10 mL/min |
| Maximum Operating Pressure | 130 MPa (19,000 psi) |
| Autosampler Configuration | Integrated 8-position (standard) or 12-position (optional) flow-through vial rack |
| Temperature Control | Ambient to 45 °C (column oven & dissolution bath interface compatible) |
| Wavelength Range | Not applicable (system interfaces with external UV-Vis or PDA detector |
| Data Acquisition Frequency | Up to 100 Hz (synchronized with dissolution sampling events) |