Liquid Chromatograph
Filter
Showing 31–60 of 200 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity III Prime Online LC |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | Up to 5 mL/min (with G7104C pump module) |
| Maximum Pressure | 800 bar |
| Injection Volume Range | 0.1–100 µL (standard) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity II Binary |
| Instrument Type | High-Performance Liquid Chromatograph (HPLC/UHPLC) |
| Flow Rate Range | Up to 5 mL/min |
| Maximum Operating Pressure | 1200 bar |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | 5–85 °C |
| UV-Vis Wavelength Range | 190–950 nm |
| Data Acquisition Rate | 160 Hz |
| Detector Flow Cell Pathlength | 60 mm (Agilent Max-Light Cartridge Flow Cell) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity II GPC/SEC |
| Instrument Type | High-Performance Liquid Chromatograph (HPLC) for Gel Permeation Chromatography / Size Exclusion Chromatography |
| Application Scope | Universal GPC/SEC Analysis |
| Flow Rate Range | Up to 5 mL/min (with G7120A binary pump and G7104A thermostatted column compartment) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL |
| Temperature Control | Dual-zone thermal management (G7116B thermostatted autosampler and column oven) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III 2D-LC |
| Instrument Type | Multidimensional Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Operating Pressure | up to 1300 bar |
| Injection Volume Range | 1–360 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 1290 Infinity III Bio LC |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | Universal for biopharmaceutical and biomolecular analysis |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Operating Pressure | 1300 bar |
| Sample Capacity | Up to 6144 positions (microplate drawer) |
| Injection Volume Range | 0.001–500 µL (0.1–1500 µL with Multi-Draw Kit) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 1290 Infinity III Bio-Online |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose with PAT-focused bioprocess monitoring |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.001–500 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III HDR-DAD |
| Instrument Type | Conventional Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose impurity profiling and trace-level quantitation |
| Flow Rate Range | Up to 5 mL/min (G7120A pump module) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (standard) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III High-Throughput |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) / Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Instrumentation |
| Flow Rate Range | Up to 5 mL/min (with G7120A & G7104A pumps) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (standard) |
| Temperature Control Zones | Dual-zone (G7116A/B) |
| Solvent Selection Capacity | 4 standard, up to 15 with optional Solvent Selection Valve |
| Column ID Reader | Optional |
| Column Capacity | 8 |
| System Dimensions (W × D) | 435 mm × 568 mm |
| Power Supply | 100–240 VAC |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 1290 Infinity III LC |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) / Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose analytical chromatography |
| Flow Rate Range | up to 5 mL/min (with G7120A binary pump and G7104A quaternary pump) |
| Maximum Operating Pressure | up to 1300 bar |
| Injection Volume Range | 0.1–100 µL (expandable to 0.1–1500 µL with Multi-Draw Kit) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity III Method Development System |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | Universal Method Development Platform |
| Flow Rate Range | up to 5 mL/min (with G7120A binary pump and G7104A quaternary pump) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (0.1–1500 µL with multi-draw kit) |
| Temperature Control Zones | 2 standard (up to 8 when clustering up to four MCTs) |
| Solvent Selection Capacity | up to 26 solvents (with two external solvent selection valves) |
| Column Capacity | 8 columns per MCT (up to 32 columns with clustered MCT configuration) |
| Column ID Reader | Optional |
| BlendAssist Functionality | Enabled with G7104A pump |
| Power Supply | 100–240 VAC |
| Width | 435 mm |
| Depth | 468 mm |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity III Method Transfer |
| Instrument Type | Conventional and Ultra-High-Performance Liquid Chromatograph (HPLC/UHPLC) |
| Application Scope | General-purpose chromatographic analysis |
| Flow Rate Range | Up to 5 mL/min (with G7120A and G7104A pumps) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (expandable to 0.1–900 µL with optional extended range kit |
| Temperature Control | Dual-zone capability (G7116A/B thermostatted compartments) |
| Solvent Selection | Up to 4 solvents standard |
| Column ID Reader | Optional |
| Column Capacity | 8 positions |
| Dimensions (W × D) | 435 mm × 468 mm |
| Power Supply | 100–240 VAC |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Multimethod |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose analytical laboratory |
| Flow Rate Range | up to 5 mL/min (with G7120A binary pump and G7104A quaternary pump) |
| Maximum Operating Pressure | 1300 bar |
| Injection Volume Range | 0.1–100 µL (standard) |
| Solvent Capacity | up to 26 solvents (with two external solvent selection valves) |
| Column Capacity | 8 columns (expandable to 32 via Multi-Column Thermostat clustering) |
| Temperature Zones | 2 standard (up to 8 with clustered MCT configuration) |
| Column ID Reader | Optional |
| BlendAssist Functionality | Enabled with G7104A pump |
| Power Supply | 100–240 VAC |
| Environmental Certification | My Green Lab ACT Label (Audited for Accountability, Consistency, Transparency across lifecycle) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity III Online SPE |
| Instrument Type | UHPLC–Online Solid-Phase Extraction Coupled System |
| Application Scope | General-Purpose Analytical Platform |
| Maximum Operating Pressure | 1300 bar |
| Temperature Control | Dual-Zone Capability (G7116A/B Modules) |
| Solvent Channels | 4 standard, up to 15 with optional Solvent Selection Valve |
| Column ID Reader | Optional |
| Column Internal Diameter Support | 8 mm max |
| Power Supply | 100–240 VAC |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity III 2D-LC |
| Instrument Type | Multidimensional Liquid Chromatograph |
| Maximum Operating Pressure | 1300 bar |
| Application Scope | General-Purpose Analytical Platform |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 218 |
| Instrument Type | UHPLC–Online SPE Coupled Purification System |
| Flow Rate Range | Up to 200 mL/min (configurable via interchangeable pump heads: 25, 100, or 200 mL/min) |
| Maximum Pressure Rating | 400 bar |
| Sample Injection Volume | 0.1–10 mL (manual or via Agilent 410 Autosampler) |
| Column Compatibility | Analytical to semi-preparative (up to 50 mm ID, including 1" and 2" i.d. columns) |
| Temperature Control | Ambient to 60 °C (optional column heater module) |
| Wavelength Range | 190–800 nm (dual-wavelength UV-Vis detection) |
| Data Acquisition Rate | Up to 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ProStar/PrepStar/SepTech Skid |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–3200 mL/min |
| Maximum Pressure | 8700 psi (600 bar) |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| UV-Vis Detector Noise | ±5 × 10⁻⁶ AU |
| Compliance | GLP, ISO 9001, cGMP (design-qualified), FDA 21 CFR Part 11-ready software architecture |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SD-1 |
| Instrument Type | Ultra-High Performance Liquid Chromatography–Online Solid-Phase Extraction (UHPLC–Online SPE) Coupled Purification System |
| Flow Rate Range | 1–200 mL/min (upgradable to 500 mL/min or 800 mL/min) |
| Maximum Pressure Rating | 400 bar |
| Sample Injection Volume | 0.1–10 mL (via manual loop or Agilent 410 Autosampler) |
| Temperature Control Range | Ambient to 80 °C (column oven optional) |
| Wavelength Range | 190–800 nm (Agilent 325 UV-Vis Detector) |
| Data Acquisition Rate | Up to 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | InfinityLab Quick-Change Valve Modules |
| Instrument Type | Multidimensional Liquid Chromatography (MD-LC) System Component |
| Integration | Compatible with Agilent InfinityLab LC Platforms (e.g., 1260, 1290, and 1290 II InfinityLab systems) |
| Drive Options | Internal (integrated into LC pump or detector module) or External (standalone valve driver unit) |
| Valve Types | 2-Position Switching Valves & Multi-Port Selection Valves |
| Pressure Rating | Up to 1300 bar (varies by specific valve model) |
| Material Compatibility | Stainless steel, PEEK, and MP35N alloy options available |
| Fluidic Path Volume | From <100 nL (low-dead-volume configurations) to ~5 µL per port (standard selection valves) |
| Brand | AIGIS |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM/ODM Producer |
| Regional Classification | Domestic (China) |
| Model | Microfluidic HPLC Valve |
| Pricing | Upon Request |
| Port Configurations | 4-, 6-, 8-, 10-, and 12-port configurations with dual-state switching (State 1 / State 2) |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | ALEXYS |
| Instrument Type | Conventional High-Performance Liquid Chromatograph with Electrochemical Detection |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 70 MPa |
| Autosampler Capacity | 192 positions |
| Injection Volume Range | 1–20 µL |
| Column Oven Temperature Range | Ambient +7 °C to 60 °C |
| Detector Output Range | −2500 mV to +2500 mV |
| Data Acquisition Frequency | 1–100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200R |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | Standard 144 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20 °C to 100 °C |
| Refractive Index (RI) Detection Range | 1.00–1.75 RIU |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Aseeker-100Plus |
| Instrument Category | Fast Liquid Chromatography System |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure Rating | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Injection Vial Capacity | 2 mL |
| Temperature Control Range | 10–50 °C |
| Wavelength Detection Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Pump Flow Range | 0.1–50 mL/min |
| Standard Extraction Cell Volume | 40 mL (optional: 10 mL / 20 mL) |
| Standard Collection Vial Volume | 250 mL (optional: 60 mL) |
| Solvent Mixing Capability | Up to 4 solvents |
| Typical Extraction Duration | 20–30 min |
| Solvent Consumption | ~10 mL per 10 g sample |
| Required Gas Supply | Nitrogen, 0.4–1 MPa |
| Max Power Consumption | 600 W |
| Electrical Input | 100–240 VAC ±10%, 50–60 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Aseeker-350Plus |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Temperature Control Range | 10–50 °C |
| Wavelength Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Cell Volume (Standard) | 120 mL |
| Pressure Accuracy | ±0.3 MPa |
| Temperature Accuracy | ±0.5 °C |
| Solvent Channels | 4 |
| Simultaneous Extraction Positions | 5 |
| Extraction Time per Batch (5 samples) | ≤20 min |
| Power Consumption | ≤1.7 kW |
| Gas Supply Requirement | N₂, 0.4–1 MPa |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SY-9100 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical use |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increment) |
| Maximum Operating Pressure | 42 MPa |
| Flow Precision | <0.1% RSD |
| Sample Tray Capacity | 96 positions (1.5 mL vials) |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +5 °C to 100 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cathodeon |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-1000 |
| Instrument Type | Fast Liquid Chromatography System |
| Flow Rate Range | 0.1–100.0 mL/min (0.1 mL/min increment) |
| Maximum Operating Pressure | ≤20 MPa |
| Fraction Collection Options | F1–F4 standard tube racks (13 mm, 15 mm, 18 mm, 25 mm OD), F5 conical flask rack (up to 100 mL |
| Sample Injection Volume Range | up to 1 L |
| Temperature Control | Ambient only |
| Wavelength Range | Dual-channel UV-Vis detection at 200–400 nm and 200–800 nm (simultaneously selectable) |
| Data Acquisition Rate | Not specified |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Conventional HPLC-Compatible Post-Column Derivatization System |
| Application | Universal for Glyphosate and Aminomethylphosphonic Acid (AMPA) Quantification |
| Flow Rate Compatibility | 0.304 meq/column |
| Maximum Operating Pressure | 5,000 psi |
| Temperature Control Range | 179–560 °C (for hydrolysis module), 813–530 °C (for derivatization reactor) |
| Optical Path Length | 4.1 mm |
| Wavelength Detection Range | 100 Å (nominal spectral bandwidth for fluorescence detection) |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| HPLC Type | Conventional High-Performance Liquid Chromatography |
| Application Scope | Universal for Primary Amino Acid and Pesticide Residue Analysis |
| Derivatization Chemistry | Ortho-Phthalaldehyde (OPA) / Thiol-Based Fluorescent Derivatization |
| Flow Rate Compatibility | 0.304 meq/column (optimized for post-column reaction at 0.5–1.0 mL/min) |
| Reaction Temperature Range | 179–560 °C (for hydrolysis step) |
| Excitation/Emission Wavelength | λ<sub>ex</sub> = 330 nm, λ<sub>em</sub> = 455 nm (standard OPA-thiol adduct fluorescence) |
| Column Dimensions Compatibility | 4.1 mm ID × 250 mm length |
| Data Acquisition Resolution | 100 Å (UV-Vis spectral sampling interval, applicable to diode-array detection) |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | R300-02 (Glyphosate-Specific) |
| Chromatography System Compatibility | Conventional HPLC with Post-Column Derivatization Module |
| Flow Rate Range | 0.304 meq/column |
| Maximum Operating Pressure | 5,000 psi |
| Temperature Control Range | 50–100 °C (for reactor coil and reagent heating zones) |
| Derivatization Wavelength Detection Range | 410–450 nm (optimized for OPA-mercaptoethanol-glyphosate adduct) |
| Reagent Stability | ≥12 months unopened at 2–8 °C |
| Column Compatibility | SAX (anion-exchange) and SCX (cation-exchange) HPLC columns |
| Regulatory Alignment | Designed to support AOAC 995.12, EPA Method 547.1, and ISO 11843-2 compliant workflows |
| Brand | CoMetro |
|---|---|
| Model | YS-CB-001 |
| Instrument Type | HPLC Post-Column Derivatization System |
| Application | Carbamate pesticide residue analysis |
| Derivatization Reagent Capacity | 1000 mL prepared solution |
| Reagent Components | R312 (OPA diluent powder), R315 (hydrolysis solid reagent), R301 (OPA stock solution), R302 (2-mercaptoethanol) |
| Compatible Column | Comatex C18-CB, 5 µm, 250 × 4.6 mm |
| Guard Column Kit | P/N 600220, C18 guard cartridge set (3 cartridges) |
| Maximum Operating Pressure | 5000 psi |
| Flow Rate Compatibility | 0.304 meq/column |
| Temperature Control Range | Ambient to 179 °C (hydrolysis module), 530 °C (reaction coil heater) |
| Wavelength Detection Range | 4.1 mm optical path length cell |
| Data Acquisition Frequency | 100 Å spectral resolution (UV-Vis detection compatible) |