| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6530 |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Field | Universal |
| Mass Range | 10–12,000 m/z |
| Sensitivity | 100.1 fg on-column (reserpine, S/N ≥ 10:1) |
| Resolution | ≥ 35,000 FWHM (at m/z 956) |
| Mass Accuracy | ≤ 2 ppm (internal calibration), ≤ 5 ppm (external calibration) |
| Pressure Range | Up to 1200 bar (UHPLC-compatible) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 6530B |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6545 |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 6545XT |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| MS Sensitivity (Positive Ion, S/N RMS) | >500:1 @ 1 pg reserpine on-column |
| MS Mass Accuracy (Positive/Negative Ion) | <0.8 ppm RMS |
| MS Acquisition Rate | 50 spectra/sec |
| MS/MS Sensitivity (Positive Ion, S/N RMS) | >1500:1 @ 1 pg reserpine on-column |
| MS/MS Mass Accuracy (Positive/Negative Ion) | <2 ppm RMS |
| MS/MS Acquisition Rate | 30 spectra/sec |
| TOF Mass Resolution (FWHM) | >50,000 @ m/z 2722, independent of acquisition rate |
| TOF Mass Range | m/z 20–30,000 |
| Quadrupole Isolation Range | m/z 20–4,000 |
| Quadrupole Resolution (FWHM) | 1.3 Da (auto-tuned) |
| Polarity Switching Duty Cycle | 1.5 s |
| Internal Calibration Stability | <1 ppm / 3 °C |
| Dynamic Range within Single Spectrum | 5 orders of magnitude |
| Ion Sources | Dual AJS-ESI, APCI, ESI/APCI multimode, GC/APCI, NanoESI |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 6546 LC/Q-TOF |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Field | Universal |
| Mass Range | m/z 20–10,000 |
| Sensitivity | S/N (RMS) > 500:1 (measured with 1 pg reserpine on-column) |
| Resolution | 30,000–60,000 FWHM (mass-dependent, acquisition-rate independent) |
| Quadrupole Resolution (FWHM) | 1.3 Da (auto-tuned) |
| Mass Accuracy | <0.8 ppm RMS (MS), <2 ppm RMS (MS/MS) |
| Isotopic Fidelity | <5% error |
| Dynamic Range | 5 orders of magnitude (intra-spectrum) |
| Polarity Switching Duty Cycle | 1.5 s |
| Ion Source Options | Dual AJS ESI, APCI, ESI/APCI multimode, GC/APCI, NanoESI |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Scope | Universal LC-MS Platform for Untargeted and Targeted Screening |
| Mass Range | Consult factory specification |
| Sensitivity | Consult factory specification |
| Resolution | >60,000 (high m/z), >30,000 (low m/z) |
| Mass Accuracy | <1 ppm (internal calibration), <2 ppm (external calibration) |
| Isotopic Fidelity | ±5% |
| Pressure Range | Consult factory specification |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 6550A |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 6550A |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Mass Range | 100–10,000 m/z |
| Sensitivity | 4500:1 (S/N, 1 pg injected) |
| Resolution | 45,000 (FWHM at m/z 922) |
| Mass Accuracy | ≤1 ppm (internal calibration) |
| Acquisition Rate | Up to 50 spectra/sec |
| Dynamic Range | >5 orders of magnitude (within single spectrum) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 6560 LC/Q-TOF |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Field | General-Purpose |
| Mass Range | m/z 20–20,000 |
| Sensitivity | S/N (RMS) > 50:1 (measured with 1 pg reserpine on-column) |
| Resolution | >42,000 FWHM at m/z 2722, acquisition-rate independent |
| Ion Mobility Resolution (FWHM) | >200 |
| Quadrupole Mass Range | m/z 20–4000 |
| Quadrupole Resolution (FWHM) | 1.3 Da (auto-tuned) |
| Mass Accuracy (MS, positive mode) | <1 ppm RMS |
| MS/MS Mass Accuracy (positive mode) | <2 ppm RMS |
| MS Acquisition Rate | 50 spectra/sec |
| MS/MS Acquisition Rate | 30 spectra/sec |
| Dynamic Range (within-spectrum) | 5 orders of magnitude |
| Ion Sources | Dual AJSM, MultiMode (ESI/APCI), Dual ESI, GC/APCI, APCI, NanoESI |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Agilent InfinityLab LC/MSD iQ |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Scope | General-Purpose LC/MS Analysis |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC/MSD |
| Instrument Type | Single Quadrupole |
| Application Scope | General-Purpose |
| Mass Range | m/z 10–2000 |
| Scan Speed | 10,400 Da/s |
| Minimum SIM Dwell Time | 5 ms |
| Polarity Switching Time | < 300 ms |
| Ion Sources | ESI, APCI, Multi-Mode (ESI + APCI) |
| Dimensions (W × D × H) | 44.3 cm × 63.5 cm × 47.0 cm |
| Compatible Software | OpenLab CDS, OpenLab ChemStation, MassHunter WalkUp, MassWorks Software |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC/MSD XT |
| Instrument Type | Single Quadrupole |
| Sensitivity | Sub-pg on-column detection limit (e.g., 500 fg injected for caffeine in ESI positive mode) |
| Ionization Sources | Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Atmospheric Pressure Photoionization (APPI), Agilent Jet Stream (AJS) ESI/APCI, Dual-Mode Source |
| Mass Range | m/z 10–3000 |
| Scan Speed | Up to 10,000 Da/sec |
| Polarity Switching | < 200 ms |
| Software Platform | OpenLAB CDS (Chemical Workstation), compliant with FDA 21 CFR Part 11 and EU Annex 11 |
| Calibration Technology | MassWorks™ high-accuracy mass calibration (Cerno Bioscience integration) |
| Form Factor | Stackable module compatible with Agilent 1260/1290 Infinity II LC systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | InfinityLab Pro iQ / Pro iQ Plus |
| Instrument Type | Single-Quadrupole Mass Spectrometer |
| Application Scope | General-Purpose LC/MS Detection |
| Mass Range | m/z 2–1600 (Pro iQ) |
| Sensitivity | < 100 fg on-column (Pro iQ, ESI positive mode, reserpine) |
| Ion Sources | ESI, APCI, Dual ESI/APCI (MMI), AJS (Pro iQ Plus only) |
| Vacuum System | Agilent MS45 rotary vane pump |
| SIM Minimum Dwell Time | 1 ms |
| Polarity Switching Speed | < 15 ms |
| Dynamic Range | Up to 6 orders of magnitude (linear) |
| Dimensions (W × D × H) | 39.6 cm × 54.8 cm × 35.0 cm |
| Software Platform | OpenLab CDS (v2.8 FP2 and later), MassHunter WalkUp, MassWorks Oligonucleotide Analyzer, Deconvolution Accelerator for OpenLab CDS |
| Key Technologies | Cyclone Ion Guide, Hyperbolic Quadrupole Mass Analyzer, VacShield Vacuum Shield, SWARM Auto-Tuning, InfinityLab Assist Interactive Touch Interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole (QQQ) |
| Model | LC-MS 1200-6410 |
| Mass Range | 10–3000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine, ESI+) |
| Resolution | 0.5–0.7 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Flow Rate Compatibility | 0.1–2.5 mL/min |
| Ion Source | Jet Stream Electrospray Ionization (ESI) |
| Optional Ion Sources | APCI, APPI |
| Software | MassHunter Workstation (Enhanced QQQ Edition) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Revident LC/Q-TOF |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Field | General-Purpose Small-Molecule Analysis |
| Mass Range | m/z 20–10,000 |
| Sensitivity | <40 fg on-column reserpine (positive mode), <40 ppt (S/N ≥ 1000:1 for 1 pg on-column) |
| <40 fg on-column chloramphenicol (negative mode), <40 ppt (S/N ≥ 750 | 1 for 1 pg on-column) |
| Resolution | TOF mass resolution (FWHM) >60,000 at m/z 2722, acquisition-rate independent |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Instrument Type | Triple Quadrupole |
| Mass Range | m/z 5–1400 |
| Sensitivity | <20 fg on-column reserpine, <20 ppt (IDL) |
| Resolution | 0.7–2.5 Da (FWHM) |
| Scan Speed | 15,000 Da/s |
| MRM Transition Rate | 500 transitions/s |
| Minimum MRM Dwell Time | 1 ms |
| Polarity Switching Time | <20 ms |
| Collision Cell Clean Time | <1 ms |
| Dimensions (W×D×H) | 32 cm × 88 cm × 39.5 cm |
| Ion Sources | ESI, AJS-ESI, APCI |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCMS-Ultivo |
| Instrument Type | Triple Quadrupole |
| Application Field | General-Purpose |
| Mass Range | 10–2,000 m/z |
| Sensitivity | <5 fg on-column injected caffeine (S/N ≥ 100:1 for MRM) |
| Resolution | Unit mass resolution (0.7 Da full width at half maximum) |
| Accurate Mass Capability | Not applicable (triple quadrupole, not high-resolution) |
| Operating Pressure Range | Ion source: atmospheric pressure |
| Collision cell | ~2–3 mTorr |
| Analyzers & detector | <1 × 10⁻⁶ Torr |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Ultivo |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Sensitivity | IDL < 12.5 fg |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | UHPLC TQMS G1 / LC-MS/MS |
| Mass Range | 2–1500 amu (standard), 2–2000 amu (G1s variant) |
| Resolution | 0.4 / 0.7 / 1.5 FWHM (full width at half maximum) |
| Application Scope | General-purpose quantitative and qualitative analysis |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | UHPLC TQMS G1 |
| Price | Upon Request |
| Application Scope | General-purpose |
| Mass Range | 2–1500 amu (G1) / 2–2000 amu (G1s) |
| Resolution | 0.4 / 0.7 / 1.5 FWHM |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PQ LC–PlasmaQuant MS |
| Instrument Type | Triple Quadrupole ICP-MS Coupled with Liquid Chromatography |
| Application Scope | Universal Elemental Speciation |
| Interface Configuration | Integrated LC–ICP-MS Coupling Kit |
| Software Platform | Clarity Chromatography Software (DataApex) + ASpect MS |
| Regulatory Compliance | FDA 21 CFR Part 11–Ready, GLP/GMP-Compatible Data Handling |
| Automation Level | Fully Automated Unattended Operation Support |
| Column Compatibility | Reversed-Phase HPLC, Ion Chromatography (IC), Size-Exclusion Chromatography (SEC) |
| Detection Capability | Sub-ng/kg LODs for As/Cr species |
| Dynamic Range | 11 orders of magnitude (ADD11 digital detector) |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | LC Cassitrap 120K |
| Pricing | Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | SQ910 LC-MS |
| Pricing | Available Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TQ9100 |
| Instrument Type | Triple Quadrupole Mass Spectrometer (QqQ) |
| Application Scope | General-Purpose LC-MS/MS |
| Resolution | Unit Resolution (m/Δm ≈ 1,000 FWHM at m/z 500) |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Domestic Product Classification | China-Made Instrument |
| Model | TQ9120 LC-MS/MS |
| Pricing | Available Upon Request |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Manufacturer | IonSense, Inc. |
| Model | ASAP |
| Instrument Type | Atmospheric Pressure Ionization Source |
| Mass Range | 5–3000 amu |
| Sensitivity | pg-level (dependent on coupled mass spectrometer) |
| Resolution | Determined by host MS platform |
| Accurate Mass Capability | Enabled via compatible high-resolution MS (e.g., Orbitrap, FT-ICR, QTOF) |
| Brand | ASPEC (Prosolia) |
|---|---|
| Origin | USA |
| Model | Flowprobe |
| Instrument Type | Ambient Ion Source |
| Compatible MS Platforms | Thermo Orbitrap, Bruker timsTOF, SCIEX TripleTOF & QTRAP |
| Sample Interface | Liquid Microjet Surface Sampling Probe (LMJ-SSP) |
| Spatial Resolution | ~630 µm (rapid profiling), down to ~50 µm (high-res DESI-2D integration) |
| Operating Mode | Real-time, continuous-flow in situ microextraction coupled with ESI ionization |
| Optical Guidance | Integrated coaxial camera for real-time probe positioning and surface navigation |
| Application Scope | Label-free molecular imaging of tissues, single-cell metabolomics, spatially resolved lipidomics/peptidomics, forensic toxicology, dried blood spot (DBS) analysis, time-resolved pharmacokinetics |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Automs TQ6000 |
| Price Range | USD 300,000–320,000 (FOB) |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Scope | General-Purpose LC-MS/MS |
| Maximum System Pressure | >12,000 psi |
| Ionization Modes | Dual ESI/APCI with Tool-Free Switching |
| Software Interface | Fully Localized Chinese GUI with Intelligent Quantitation & Method Development Engine |
| Regulatory Compliance | Designed to support GLP/GMP workflows, audit trail-enabled data handling, and 21 CFR Part 11–compliant user access control (optional configuration) |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Field | General-Purpose |
| Mass Range | 10–2250 Da |
| Ionization Sources | Dual ESI/APCI |
| Collision Cell | Curved RF-only Quadrupole Design |
| Gas System | Counter-Flow Curtain Gas Configuration |
| Software | Integrated Intelligent Tuning, Calibration, Method Optimization & Reporting Engine |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | HMS7680 |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Application Scope | General-Purpose |
| Ionization Sources | ESI and APCI |
| IM Resolution Modes | 3 Adjustable Settings |
| Mass Analyzer Configuration | Quadrupole + Orthogonal TOF |
| Collision Cell | Axial DC Voltage Gradient CID with Tunable Collision Gas |
| Temperature Control | Water-Cooled, Thermally Stabilized Flight Tube with Intelligent Compensation |
| Acquisition Mode | 4D Full-Spectrum Simultaneous Detection |
| Software Features | Automated Tuning, Real-Time Mass Calibration, Method Optimization, and Integrated Data Processing & Reporting |