Mass Spectrometry Instruments
Filter
Showing 31–60 of 765 results
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Series | Multiple Catalog Numbers |
| Pricing | Available Upon Request |
| Brand | Agena Bioscience |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MassARRAY Nucleic Acid Mass Spectrometer |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Application Scope | General-Purpose Biomolecular Analysis |
| Resolution | >750 across full detection range |
| Sensitivity | ≥5% for routine somatic mutation detection |
| Stability | Measurement deviation ≤ ±5% |
| Throughput | ≤15 minutes for 96 samples |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1100-1956 |
| Instrument Type | Single Quadrupole |
| Mass Range | 10–3000 amu |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine, ESI+) |
| Resolution | 0.5–0.7 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da (typical, calibrated) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1200 |
| Quotation | Upon Request |
| Instrument Type | Triple Quadrupole |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 240-MS |
| Instrument Type | Ion Trap Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Coupling |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 5975T |
| Instrument Type | Portable GC-MS |
| Mass Range | 1.8–1050 amu |
| Dynamic Range | 6 orders of magnitude |
| Mass Resolution | Unit mass resolution, tunable via MS calibration |
| Maximum Scan Rate | 12,500 amu/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 5975T |
| Mass Range | 1.8–1050 amu |
| Dynamic Range | 6 orders of magnitude |
| Mass Resolution | Unit mass resolution (tunable via tuning) |
| Maximum Scan Rate | 12,500 amu/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 5977C GC/MSD |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | m/z 0.6 to 1091 |
| Sensitivity | HES EI – 10 fg IDL, 1 µL OFN injection |
| Hydro Inert Source with H₂ carrier – 100 fg OFN, 1 µL injection | IDL 50 fg |
| Scan Speed | ≤ 20,000 Da/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6100 |
| Instrument Type | Single Quadrupole LC/MS (not Tandem Quadrupole) |
| Scan Speed | Up to 10,000 u/s |
| Detection Limit | Sub-picogram (with Agilent Jet Stream Technology on 6130/6150 variants) |
| Compatibility | Fully Integrated with Agilent 1220/1260/1290 Infinity LC Systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 6230B |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) LC/MS System |
| Mass Accuracy | <1 ppm (RMS) |
| Mass Resolution | >22,000 (FWHM at m/z 556) |
| Acquisition Rate | Up to 30 spectra/sec |
| Dynamic Range | 5 orders of magnitude |
| Sensitivity | Sub-picomolar on-column detection (using Agilent Jet Stream ESI source) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6230B |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Mass Accuracy (Positive Mode) | <1 ppm RMS |
| Acquisition Rate | 30 spectra/sec |
| Resolution (FWHM) | >22,000 at m/z 1522, independent of acquisition speed |
| Mass Range | m/z 25–20,000 |
| Ion Sources | ESI, AJS-ESI, APCI, Dual ESI/APCI, NanoESI, CE-ESI, GC-APCI |
| Dynamic Range (within single spectrum) | 5 decades |
| Polarity Switching Duty Cycle | <1 sec |
| Mass Stability | <2 ppm / 2 °C |
| Software Platform | MassHunter Suite (including WalkUp, BioConfirm, Mass Profiler Professional, Vista, Flux) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 6470 |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | Universal |
| Sensitivity | Up to 5× higher than conventional ESI sources |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 6470B |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | General-Purpose |
| Mass Range | m/z 5–3000 |
| Sensitivity | < 4 fg on-column ritalin (reserpine), < 4 ppt in solution |
| Resolution Modes | Narrow = 0.4 Da, Unit = 0.7 Da, Wide = 1.2 Da, Widest = 2.5 Da |
| Pressure Range | Not applicable (vacuum-operated system) |
| Ion Sources | Agilent Jet Stream (AJS), Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Multi-Mode Ionization (MMI) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 6475 |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | Universal |
| Mass Range | m/z 5–3000 |
| Sensitivity | < 3.5 fg on-column reserpine (positive mode), < 3.5 ppt IDL (using Agilent Jet Stream Ion Source + Verification Column + 1290 Infinity II LC system) |
| Negative Mode IDL | < 4 fg chloramphenicol, < 4 ppt IDL (same configuration) |
| MRM Transition Rate | 500 transitions/s |
| Quadrupole Resolution (FWHM) | 0.4 Da (narrow), 0.7 Da (unit mass), 1.2 Da (wide), 2.5 Da (broad) |
| Scan Speed | 18,700 Da/s |
| Minimum MRM Dwell Time | 0.5 ms |
| Polarity Switching Time | < 25 ms |
| Collision Cell Cleaning Time | < 1 ms |
| Ion Sources | ESI, APCI, MultiMode (ESI/APCI), Nano-ESI, Agilent Jet Stream (AJS) |
| Dimensions (W × D × H) | 47.5 cm × 77.3 cm × 84 cm |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6495 |
| Instrument Type | Tandem Quadrupole (QqQ) Mass Spectrometer |
| LC Integration | Fully Compatible with Agilent 1200/1290 UHPLC Systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6495B |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Mass Range | m/z 3000 |
| Ion Source | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) |
| Key Technology | iFunnel Ion Optics |
| Maintenance Feature | Plug-and-Play Ion Source with Vacuum Isolation Valve |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6495C |
| Instrument Type | Tandem Quadrupole (Triple Quadrupole) |
| Application Scope | General-Purpose Quantitative and Qualitative Analysis |
| Mass Range | 5–3000 m/z |
| Ion Source Maintenance | Vacuum-Shield Enabled (No Vent Required) |
| Key Technology | Third-Generation All-Metal iFunnel, Triggered Multiple Reaction Monitoring (tMRM), Direct Skyline Integration, MassHunter Software Platform |
| Regulatory Compliance | Designed for US FDA 21 CFR Part 11, EU Annex 11, and GLP/GMP Data Integrity Requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6495D |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | General-Purpose Targeted Quantitation |
| Mass Range | m/z 5–3000 |
| Resolution (FWHM) | Unit Mass = 0.7 Da |
| MRM Transition Rate | 700 transitions/s |
| Minimum MRM Dwell Time | 0.5 ms |
| Polarity Switching Speed | <25 ms |
| Ion Sources | ESI, AJS-ESI, APCI, Dual ESI/APCI, Nano-ESI |
| Vacuum Pump Options | MS120 Roughing Pump or Edwards nXL200i Oil-Free Dry Pump (Optional) |
| Collision Cell Clean Time | <1 ms |
| Dimensions (W×D×H) | 91.5 cm × 77.3 cm × 47.5 cm |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 6530B |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6545 |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 6545XT |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| MS Sensitivity (Positive Ion, S/N RMS) | >500:1 @ 1 pg reserpine on-column |
| MS Mass Accuracy (Positive/Negative Ion) | <0.8 ppm RMS |
| MS Acquisition Rate | 50 spectra/sec |
| MS/MS Sensitivity (Positive Ion, S/N RMS) | >1500:1 @ 1 pg reserpine on-column |
| MS/MS Mass Accuracy (Positive/Negative Ion) | <2 ppm RMS |
| MS/MS Acquisition Rate | 30 spectra/sec |
| TOF Mass Resolution (FWHM) | >50,000 @ m/z 2722, independent of acquisition rate |
| TOF Mass Range | m/z 20–30,000 |
| Quadrupole Isolation Range | m/z 20–4,000 |
| Quadrupole Resolution (FWHM) | 1.3 Da (auto-tuned) |
| Polarity Switching Duty Cycle | 1.5 s |
| Internal Calibration Stability | <1 ppm / 3 °C |
| Dynamic Range within Single Spectrum | 5 orders of magnitude |
| Ion Sources | Dual AJS-ESI, APCI, ESI/APCI multimode, GC/APCI, NanoESI |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 6546 LC/Q-TOF |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Field | Universal |
| Mass Range | m/z 20–10,000 |
| Sensitivity | S/N (RMS) > 500:1 (measured with 1 pg reserpine on-column) |
| Resolution | 30,000–60,000 FWHM (mass-dependent, acquisition-rate independent) |
| Quadrupole Resolution (FWHM) | 1.3 Da (auto-tuned) |
| Mass Accuracy | <0.8 ppm RMS (MS), <2 ppm RMS (MS/MS) |
| Isotopic Fidelity | <5% error |
| Dynamic Range | 5 orders of magnitude (intra-spectrum) |
| Polarity Switching Duty Cycle | 1.5 s |
| Ion Source Options | Dual AJS ESI, APCI, ESI/APCI multimode, GC/APCI, NanoESI |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 6550A |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 6550A |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Mass Range | 100–10,000 m/z |
| Sensitivity | 4500:1 (S/N, 1 pg injected) |
| Resolution | 45,000 (FWHM at m/z 922) |
| Mass Accuracy | ≤1 ppm (internal calibration) |
| Acquisition Rate | Up to 50 spectra/sec |
| Dynamic Range | >5 orders of magnitude (within single spectrum) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 6560 LC/Q-TOF |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Field | General-Purpose |
| Mass Range | m/z 20–20,000 |
| Sensitivity | S/N (RMS) > 50:1 (measured with 1 pg reserpine on-column) |
| Resolution | >42,000 FWHM at m/z 2722, acquisition-rate independent |
| Ion Mobility Resolution (FWHM) | >200 |
| Quadrupole Mass Range | m/z 20–4000 |
| Quadrupole Resolution (FWHM) | 1.3 Da (auto-tuned) |
| Mass Accuracy (MS, positive mode) | <1 ppm RMS |
| MS/MS Mass Accuracy (positive mode) | <2 ppm RMS |
| MS Acquisition Rate | 50 spectra/sec |
| MS/MS Acquisition Rate | 30 spectra/sec |
| Dynamic Range (within-spectrum) | 5 orders of magnitude |
| Ion Sources | Dual AJSM, MultiMode (ESI/APCI), Dual ESI, GC/APCI, APCI, NanoESI |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Quadrupole Mass Spectrometer (Single Quadrupole) |
| GC Compatibility | Agilent 6890 Series GC |
| Mass Range | Up to 1050 u |
| Ion Source | Inert, Temp-Controlled to 350 °C |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with AutoCI |
| Scan Speed | Up to 4.8 scans/sec (typical) |
| Resolution | Unit mass resolution (R = 1000, 10% valley) |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in EI full-scan mode (S/N ≥ 20:1) |
| Data System | MSD ChemStation (G1701DA) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1.6–800 u (amu) |
| Mass Accuracy | ±0.1 u |
| EI Sensitivity | ≥20:1 S/N for 1 pg OFN at m/z 272 (Full Scan) |
| SIM Sensitivity | ≥10:1 S/N for 20 fg OFN at m/z 272 |
| PCI Sensitivity | ≥75:1 S/N for 100 pg Benzophenone at m/z 183.1 |
| NCI Sensitivity | ≥500:1 S/N for 1 pg OFN at m/z 272 |
| Ion Source | Electron Ionization (EI), Chemical Ionization (CI), and Negative Chemical Ionization (NCI) capable |
| Ion Source Material | Molybdenum alloy, temperature-controlled |
| Quadrupole | Gold-coated quartz, hyperbolic rod set, heated and independently temperature-regulated |
| GC Oven Temperature Range | Ambient to 400 °C |
| Injector Types | Programmable Temperature Vaporizer (PTV) and Split/Splitless Capillary Injector |
| Mass Scan Modes | Full Scan, Selected Ion Monitoring (SIM), and Tuning |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N-5973N |
| Instrument Type | Single Quadrupole GC-MS System |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| MS Analyzer Type | Quadrupole Mass Filter |
| Mass Range | 1.5–650 u (nominal mass scale) |
| Resolution | Unit mass resolution (typical, 10% valley definition) |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in full-scan mode (m/z 272, S/N ≥ 10:1) |
| Scan Speed | Up to 6,400 Da/sec (full-scan, 0.1 sec/decade) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N-5973 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Mass Range | 1.6–800 amu |
| Resolution | Unit mass resolution (nominal) |
| EI Sensitivity | ≥20:1 S/N for 1 pg OFN at m/z 272 (full scan) |
| SIM Sensitivity | ≥10:1 S/N for 20 fg OFN at m/z 272 |
| Scan Speed | 11,000 amu/sec |
| Ion Source | Electron Ionization (EI), optional Chemical Ionization (CI) and Negative Chemical Ionization (NCI) |
| GC Oven Temperature Range | Ambient to 400 °C |
| GC Inlet Types | Programmable Temperature Vaporizing (PTV) inlet and split/splitless capillary inlet |
| Mass Spectrometer Operating Temperature | Independently controlled ion source and quadrupole (up to 350 °C) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N (GC) / 5973N (MSD) |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Capillary Column Inlet with Electronic Pressure Control (EPC) |
| MS Ionization Modes | Electron Ionization (EI), Chemical Ionization (CI), Negative Chemical Ionization (NCI) |
| Mass Range | 1.6–800 u |
| Mass Accuracy | ±0.1 u |
| EI Sensitivity | 1 pg OFN (m/z 272), S/N ≥ 20:1 (full scan) |
| 20 fg OFN (m/z 272), S/N ≥ 10 | 1 (SIM) |
| PCI Sensitivity | 100 pg di-tert-butyl methylamine (m/z 183.1), S/N ≥ 75:1 |
| NCI Sensitivity | 1 pg OFN (m/z 272), S/N ≥ 500:1 |
| Quadrupole | Gold-coated quartz, temperature-controlled, hyperbolic geometry |
| Ion Source | Molybdenum alloy, independently heated, inert surface finish |