| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Revident LC/Q-TOF |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Field | General-Purpose Small-Molecule Analysis |
| Mass Range | m/z 20–10,000 |
| Sensitivity | <40 fg on-column reserpine (positive mode), <40 ppt (S/N ≥ 1000:1 for 1 pg on-column) |
| <40 fg on-column chloramphenicol (negative mode), <40 ppt (S/N ≥ 750 | 1 for 1 pg on-column) |
| Resolution | TOF mass resolution (FWHM) >60,000 at m/z 2722, acquisition-rate independent |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5975 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Mass Range | 1.5–1050 amu |
| Resolution | 1000–2000 (FWHM at m/z 502) |
| Sensitivity | >300:1 (Signal-to-Noise Ratio, SIM mode, m/z 502, 100 fg injected) |
| Scan Speed | 10,000 u/s |
| Includes | Agilent 7820A GC, Agilent 5975(G3175A) MSD, Agilent 7693A Autosampler (150-position tray), Turbomolecular Vacuum Pump, Dedicated PC with ChemStation Software |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCMS-Ultivo |
| Instrument Type | Triple Quadrupole |
| Application Field | General-Purpose |
| Mass Range | 10–2,000 m/z |
| Sensitivity | <5 fg on-column injected caffeine (S/N ≥ 100:1 for MRM) |
| Resolution | Unit mass resolution (0.7 Da full width at half maximum) |
| Accurate Mass Capability | Not applicable (triple quadrupole, not high-resolution) |
| Operating Pressure Range | Ion source: atmospheric pressure |
| Collision cell | ~2–3 mTorr |
| Analyzers & detector | <1 × 10⁻⁶ Torr |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Ultivo |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Sensitivity | IDL < 12.5 fg |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | ICP9090 |
| Pricing | Upon Request |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AL-ICP9090 |
| Pricing | Upon Request |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic |
| Model | ICP-MS9800 |
| Pricing | Upon Request |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | UHPLC TQMS G1 / LC-MS/MS |
| Mass Range | 2–1500 amu (standard), 2–2000 amu (G1s variant) |
| Resolution | 0.4 / 0.7 / 1.5 FWHM (full width at half maximum) |
| Application Scope | General-purpose quantitative and qualitative analysis |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | UHPLC TQMS G1 |
| Price | Upon Request |
| Application Scope | General-purpose |
| Mass Range | 2–1500 amu (G1) / 2–2000 amu (G1s) |
| Resolution | 0.4 / 0.7 / 1.5 FWHM |
| Brand | Applied Spectra |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Alphachron |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Mass Range | 1–50 u |
| Brand | Alyxan |
|---|---|
| Origin | France |
| Model | PTR-FTICR MS |
| Mass Resolution | ≥10,000 (m/Δm, 50% valley) |
| Mass Accuracy | ≤0.015 u |
| Detection Limit | 100 ppt (v/v) for selected VOCs |
| Mass Range | 4–300 u |
| Magnetic Field Strength | 1.5 T |
| Vacuum Requirement | ≤1×10⁻⁹ Torr |
| Operating Temperature | 5–45 °C |
| Dynamic Range | 10⁴ |
| Dimensions | 65 × 72 × 104 cm |
| Weight | 150 kg |
| Ion Sources | H₃O⁺, O₂⁺, O⁻, CF₃⁺ (switchable proton-transfer reagent ions) |
| Sample Introduction | Membrane Inlet (MI), Headspace (solid/liquid) |
| Ionization Mode | Proton Transfer Reaction (PTR), optional EI/CI capability |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Model | AMI-Master 400 Quadrupole Mass Spectrometer |
| Configuration | Benchtop Process Mass Spectrometry System |
| Ion Source | Electron Impact (EI), 70 eV standard |
| Mass Range | 1–300 amu |
| Detection Modes | Faraday Cup & Electron Multiplier (dual-mode) |
| Scan Speed | <10 ms per decade |
| Response Time | <100 ms (full-spectrum acquisition) |
| Operating Pressure (Ion Source) | 1×10⁻⁶ to 5×10⁻⁵ Torr |
| Vacuum System | Turbo-molecular pump (200 L/s) + Oil-free diaphragm backing pump |
| Inlet Temperature Control | Ambient to 200 °C (capillary + filter assembly, independently regulated) |
| Chamber Bake-out Capability | Up to 200 °C |
| Software Platform | Windows 7/10-compatible multi-channel gas analysis suite with real-time quantitation, spectral library matching, and audit-trail-enabled data logging |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Model | AMI-Master400 |
| Vacuum System | Turbo-molecular pump + oil-free diaphragm dry pump with full-range vacuum gauge |
| Inlet System | Heated stainless-steel or quartz capillary (ambient–200 °C), dual-stage pressure reduction |
| Mass Analyzer | Quadrupole mass filter with electron impact (EI) ion source |
| Detectors | Dual-mode detection — Faraday cup and electron multiplier |
| Detection Range | 100% to sub-ppb (v/v) |
| Response Time | <100 ms |
| Scan Speed | Millisecond-scale mass scanning |
| Mass Range | 1–300 u (standard), upgradable to 500 u |
| Operating Software | Multi-channel gas analysis suite for Windows 7/10, compliant with GLP/GMP data integrity requirements |
| Bake-out Capability | Mass spectrometer chamber heatable to 200 °C for in-situ outgassing |
| Compliance | Designed to support ASTM D7622, ISO 10156, USP <1251>, and FDA 21 CFR Part 11 audit-trail functionality |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi X 2500 |
| Sample Types | AOX, TOX, EOX, POX, TX |
| Detection Principle | Combustion–Microcoulometric Detection |
| Automation | Integrated Sample Preparation Module |
| Compliance | ASTM D5907, ISO 9562, DIN 38409-H16, EN 1485 |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PlasmaQuant MS |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | Not Specified |
| Mass Resolution (Unit Mass Resolution, amu) | Not Specified |
| Detection Limit (ng·L⁻¹) | Not Specified |
| Sensitivity (Mcps/mg·L⁻¹) | Not Specified |
| Short-Term Stability (RSD) | Not Specified |
| Long-Term Stability (RSD) | Not Specified |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Instrument Type | Quadrupole ICP-MS |
| Model | PlasmaQuant MS |
| Application Domain | Laboratory-based elemental and isotopic analysis |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Gas Consumption | <9 L/min Ar plasma gas |
| Oxide Rate (CeO⁺/Ce⁺) | ≤1.8% |
| Double-Charge Rate (Ba²⁺/Ba⁺) | ≤2% |
| Detection Limit Performance | 7Li ≥100 Mcps/ppm, 115In ≥500 Mcps/ppm, 238U ≥500 Mcps/ppm |
| Dynamic Range | 0.1–10¹⁰ cps (11-decade linear range in pulse-counting mode) |
| Quadrupole Drive Frequency | 3.0 MHz |
| Mass Scan Speed | 5115 amu/s |
| Minimum Dwell Time | 50 µs |
| iCRC Collision/Reaction Cell | Dual-gas (He/H₂) configurable, with BOOST technology for sensitivity preservation |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PQ LC–PlasmaQuant MS |
| Instrument Type | Triple Quadrupole ICP-MS Coupled with Liquid Chromatography |
| Application Scope | Universal Elemental Speciation |
| Interface Configuration | Integrated LC–ICP-MS Coupling Kit |
| Software Platform | Clarity Chromatography Software (DataApex) + ASpect MS |
| Regulatory Compliance | FDA 21 CFR Part 11–Ready, GLP/GMP-Compatible Data Handling |
| Automation Level | Fully Automated Unattended Operation Support |
| Column Compatibility | Reversed-Phase HPLC, Ion Chromatography (IC), Size-Exclusion Chromatography (SEC) |
| Detection Capability | Sub-ng/kg LODs for As/Cr species |
| Dynamic Range | 11 orders of magnitude (ADD11 digital detector) |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | Anyeep 7600 |
| Price Range | USD 42,000–70,000 (FOB Jiangsu) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC Interface |
| Mass Range | 1.5–1050 u |
| Resolution (10% Valley) | 2000 |
| Sensitivity | 1 pg Octafluoronaphthalene (OFN), m/z 272, S/N ≥ 600:1 (RMS) |
| Scan Speed | 20,000 u/s |
| Oven Ramp Rate | Up to 120 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | Anyeep Precision Instruments Co., Ltd. |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Conventional Gas Chromatography Interface |
| Mass Range | 0–1250 amu |
| Vacuum Architecture | Dual-Chamber, Dual-Turbomolecular Pump System (Independent Ion Source & Quadrupole Exhaust) |
| Startup-to-Analysis Time | ≤30 min |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph Coupling |
| Mass Analyzer | Dual-Hyperbolic Rod Quadrupole |
| Resolution (FWHM at m/z 69) | 0.25 Da |
| Isotopic Ratio Accuracy | Enhanced for PFBA, PFTBA, and Low-Mass Ions (He⁺, H₂O⁺, N₂⁺, O₂⁺) |
| RF Power Supply | Upgraded Wide-Mass-Range Stable Frequency Generator |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | Anyeep Cassitrap 120K |
| Chromatography Type | Capillary GC-coupled |
| Mass Range | 1.5–1250 Da (Quadrupole Mode) |
| Resolution | >120,000 FWHM at m/z 131 (1.5 Hz acquisition rate) |
| Sensitivity | ≥1000:1 S/N for 100 fg octafluoronaphthalene (OFN), m/z 272 (quadrupole mode) |
| Scan Speed | 20,000 Da/s (quadrupole mode) |
| Mass Accuracy | ±0.1 Da (quadrupole mode) |
| Oven Ramp Rate | ≥120 °C/min (standard column oven) |
| Detector | Electron Multiplier (quadrupole mode only) |
| Pressure Control Precision | ±0.001 psi |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | LC Cassitrap 120K |
| Pricing | Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Mate11 |
| Instrument Type | Portable GC-MS |
| Mass Range | 1.5–550 amu |
| Dynamic Range | 7 orders of magnitude |
| Mass Resolution | Unit mass resolution |
| Maximum Scan Rate | 10,000 amu/s |
| Sensitivity | 1 pg octafluoronaphthalene (OFN), S/N = 150:1 (RMS) |
| Weight | < 20 kg |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RGA 6500 |
| Pricing | Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | SQ910 LC-MS |
| Pricing | Available Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Model | Anyeep TQ8100 |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | Integrated acquisition and quantitation platform with audit trail capability |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TQ9100 |
| Instrument Type | Triple Quadrupole Mass Spectrometer (QqQ) |
| Application Scope | General-Purpose LC-MS/MS |
| Resolution | Unit Resolution (m/Δm ≈ 1,000 FWHM at m/z 500) |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Domestic Product Classification | China-Made Instrument |
| Model | TQ9120 LC-MS/MS |
| Pricing | Available Upon Request |
| Brand | Applied Spectra |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RESOchron SE/LR |
| Instrument Type | Rare Gas Isotope Ratio Mass Spectrometer |
| Pricing | Upon Request |
| Brand | Arrow grand Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGIA |
| Pricing | Available Upon Request |