| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | GCMS 6890N-5973N |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | 1–1000 amu |
| Resolution | 1000–2000 (FWHM at m/z 272) |
| Sensitivity | >300:1 (S/N, EI mode, 1 pg octafluoronaphthalene, m/z 272) |
| Scan Speed | 15,000 u/s |
| Ionization Modes | Electron Impact (EI), Chemical Ionization (CI), Negative Chemical Ionization (NCI) |
| Injector Types | Split/Splitless and Programmable Temperature Vaporizing (PTV) inlets |
| Oven Temperature Range | Ambient to 400 °C |
| Mass Accuracy | ±0.1 u |
| Library | NIST 2008 Mass Spectral Library |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 7000E GC/MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC/MS |
| Mass Range | m/z 10–1050 |
| Sensitivity | Inert Plus EI Ion Source – IDL ≤ 4 fg (10 fg OFN injection) |
| Scan Speed | ≤ 20,000 Da/s |
| Detector | Agilent Triple-Axis HED-EM with Extended-Life Electron Multiplier and Dynamically Ramped Iris |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS/MS |
| Mass Range | m/z 10–1050 |
| Sensitivity | IDL ≤ 0.3 fg for 1 fg OFN injection |
| Scan Speed | ≤ 20,000 Da/s |
| Detector | Agilent triple-axis high-efficiency dynamic electron multiplier (HED-EM) with extended-life EM and dynamically ramped iris aperture |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| GC Configuration | Conventional GC/MS |
| Mass Range | m/z 20–3000 |
| Resolution | >25,000 FWHM at m/z 271.9867, acquisition-rate independent |
| Sensitivity | IDL <60 fg for 100 fg OFN injection |
| Detector | Microchannel plate/scintillator/PMT with ADC electronics |
| Mass Accuracy | <2 ppm (1 pg OFN, m/z 271.9867) |
| Quadrupole Mass Range | m/z 20–1050 |
| Acquisition Rate | 1–50 spectra/sec, resolution-independent |
| Software Platform | Agilent MassHunter |
| GC Compatibility | Fully compatible with Agilent 8890/8860 GC systems and ZOEX thermal modulator for comprehensive 2D-GC (GC×GC) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7700 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Resolution (Unit Mass Resolution, amu) | ≤ 0.8 |
| Detection Limit | sub-ppq ng·L⁻¹ |
| Sensitivity (Mcps / mg·L⁻¹) | Be ≥ 5, In ≥ 30, Bi ≥ 20 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7850 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–260 |
| Resolution (Unit Mass Resolution, amu) | 0.2–1 (adjustable) |
| Detection Limit (ng·L⁻¹) | ≤5×10⁻⁷ for low-mass elements, ≤1×10⁻⁷ for high-mass elements |
| Sensitivity (Mcps / mg·L⁻¹) | Li ≥ 80, Y ≥ 240, U ≥ 300 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7850 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 5–260 |
| Unit Mass Resolution (amu) | 0.5 |
| Detection Limit (ng·L⁻¹) | 10 |
| Sensitivity (Mcps / mg·L⁻¹) | 10 |
| Short-Term Stability (RSD %) | 3 |
| Long-Term Stability (RSD %) | 5 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A GC / 5975C MSD |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (full width at half maximum, FWHM) |
| Sensitivity | >300:1 signal-to-noise ratio (S/N) for methyl stearate at 1 pg on-column injection |
| Scan Speed | 15,000 u/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 7890A-5975C |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | m/z 1–1000 |
| Resolution | 1000–2000 (at 10% valley, peak width at half height) |
| Sensitivity | >300:1 (Signal-to-Noise Ratio, SIM mode, using octafluoronaphthalene) |
| Scan Speed | 15,000 u/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A-7000B |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | 1.2–1050 amu (0.1 amu increment) |
| Resolution | Unit Mass Resolution |
| Sensitivity | Auto-tune Mode |
| Scan Speed | 150,000 u/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B-5977B |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (full width at half maximum, FWHM) |
| Sensitivity | >300:1 signal-to-noise ratio (S/N) for methyl stearate or chlorobenzene (typical electron ionization, EI) |
| Scan Speed | 15,000 u/s |
| Inlet Pressure Range | 0–100 psi (optional 0–150 psi) |
| Carrier Gas Flow Control | Electronic Pressure Control (EPC) |
| Oven Temperature Range | 4 °C above ambient to 450 °C |
| Detection Limit (FID) | <5 pg C/s (propane) |
| Autosampler | Agilent 7683 with 100-position tray |
| Injection Volume | 0.1–100 µL |
| Total Flow Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7900 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization with Quadrupole Mass Filtering |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 8900 |
| Instrument Type | Quadrupole-based Triple Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B-7000C |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Type | Conventional Gas Chromatograph |
| Mass Range | 10,000 m/z |
| Resolution | 1000 (FWHM) |
| Sensitivity | 300 cps/fA (electron multiplier gain referenced) |
| Scan Speed | 15,000 Da/sec |
| Mass Accuracy | ±100 ppm (calibrated) |
| Oven Ramp Rate | 125 °C/min |
| Detector Count | 10 (including HED-EM and optional TCD/ECD) |
| Pressure Control Precision | ±0.001 psi |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HLD BD15 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HLD BD30 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HLD BR15 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HLD BR30 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HLD MD15 |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HLD MD30 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HLD MR15 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HLD MR30 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HLD PD03 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HLD PR02 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Agilent InfinityLab LC/MSD iQ |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Scope | General-Purpose LC/MS Analysis |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC/MSD |
| Instrument Type | Single Quadrupole |
| Application Scope | General-Purpose |
| Mass Range | m/z 10–2000 |
| Scan Speed | 10,400 Da/s |
| Minimum SIM Dwell Time | 5 ms |
| Polarity Switching Time | < 300 ms |
| Ion Sources | ESI, APCI, Multi-Mode (ESI + APCI) |
| Dimensions (W × D × H) | 44.3 cm × 63.5 cm × 47.0 cm |
| Compatible Software | OpenLab CDS, OpenLab ChemStation, MassHunter WalkUp, MassWorks Software |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC/MSD XT |
| Instrument Type | Single Quadrupole |
| Sensitivity | Sub-pg on-column detection limit (e.g., 500 fg injected for caffeine in ESI positive mode) |
| Ionization Sources | Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Atmospheric Pressure Photoionization (APPI), Agilent Jet Stream (AJS) ESI/APCI, Dual-Mode Source |
| Mass Range | m/z 10–3000 |
| Scan Speed | Up to 10,000 Da/sec |
| Polarity Switching | < 200 ms |
| Software Platform | OpenLAB CDS (Chemical Workstation), compliant with FDA 21 CFR Part 11 and EU Annex 11 |
| Calibration Technology | MassWorks™ high-accuracy mass calibration (Cerno Bioscience integration) |
| Form Factor | Stackable module compatible with Agilent 1260/1290 Infinity II LC systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | InfinityLab Pro iQ / Pro iQ Plus |
| Instrument Type | Single-Quadrupole Mass Spectrometer |
| Application Scope | General-Purpose LC/MS Detection |
| Mass Range | m/z 2–1600 (Pro iQ) |
| Sensitivity | < 100 fg on-column (Pro iQ, ESI positive mode, reserpine) |
| Ion Sources | ESI, APCI, Dual ESI/APCI (MMI), AJS (Pro iQ Plus only) |
| Vacuum System | Agilent MS45 rotary vane pump |
| SIM Minimum Dwell Time | 1 ms |
| Polarity Switching Speed | < 15 ms |
| Dynamic Range | Up to 6 orders of magnitude (linear) |
| Dimensions (W × D × H) | 39.6 cm × 54.8 cm × 35.0 cm |
| Software Platform | OpenLab CDS (v2.8 FP2 and later), MassHunter WalkUp, MassWorks Oligonucleotide Analyzer, Deconvolution Accelerator for OpenLab CDS |
| Key Technologies | Cyclone Ion Guide, Hyperbolic Quadrupole Mass Analyzer, VacShield Vacuum Shield, SWARM Auto-Tuning, InfinityLab Assist Interactive Touch Interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole (QQQ) |
| Model | LC-MS 1200-6410 |
| Mass Range | 10–3000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine, ESI+) |
| Resolution | 0.5–0.7 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Flow Rate Compatibility | 0.1–2.5 mL/min |
| Ion Source | Jet Stream Electrospray Ionization (ESI) |
| Optional Ion Sources | APCI, APPI |
| Software | MassHunter Workstation (Enhanced QQQ Edition) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PHD-4 |
| Price Range | USD 13,500 – 40,500 |