Mass Spectrometry Instruments
Filter
Showing 151–180 of 765 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Model | timsTOF fleX with MALDI-2 |
| Application Scope | Universal (Biological Tissue Imaging, Lipidomics, Metabolomics, Drug Distribution Studies) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | SCiLS Lab, DataAnalysis, and TIMS Control integrated in Compass 6.0 suite |
| Ionization Modes | MALDI and MALDI-2 (laser post-ionization), ESI (via LC coupling) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsTOF HT |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Technology | Parallel Accumulation–Serial Fragmentation (PASEF®), CCS-enabled 4D-Proteomics |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF MS) |
| Ionization Modes | Dual MALDI/ESI |
| Application Focus | Label-free Ultra-High-Throughput Screening (uHTS) in Drug Discovery |
| Software Platform | MALDI PharmaPulse® 2023 |
| Compliance Ready | GLP/GMP-aligned data handling, 21 CFR Part 11–compatible audit trail (via optional software configuration) |
| Throughput | Up to 3 samples/sec on 1536-well plates |
| CCS Calibration | Yes, with internal standards |
| MALDI Source | 10 kHz smartbeam™ 3D laser, MALDI-2 option available |
| Sample Handling | Robotic MALDI target auto-loader, disposable targets (96–1536-well compatible) |
| Data Export | Native support for Genedata Screener®, Assay Explorer, and other HTS informatics platforms |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | timsTOF Pro 2 |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Domain | Specialized Omics Research (Proteomics, Lipidomics, Phosphoproteomics, Clinical Biomarker Discovery) |
| Regulatory Context | Compliant with GLP/GMP data integrity requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF) |
| Model | timsTOF SCP |
| Application Domain | Specialized Single-Cell Proteomics, Immunopeptidomics, PTM Analysis, Epigenoproteomics |
| Ion Source | Optimized Dual-Orthogonal Reflectron Ion Source with 1-mm Transfer Capillary |
| Vacuum Architecture | 8-stage Differential Vacuum System |
| Acquisition Mode | dia-PASEF® (Data-Independent Acquisition Parallel Accumulation–Serial Fragmentation) |
| CCS Capability | Yes, Collision Cross Section–enabled Ion Mobility Separation |
| Scan Speed | >120 Hz MS/MS |
| Software Platform | timsControl, PaSER (Real-time Parallel Database Search Engine), Compatible with MaxQuant/Perseus, PEAKS Studio |
| Data Format | Open .d Format (Bruker) |
| Regulatory Compliance | Supports 21 CFR Part 11–compliant workflows (audit trail, electronic signatures, data integrity controls) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsUltra AIP |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Specialized Proteomics & Multi-Omics Platforms |
| Software Integration | TIMS PASEF®, TIMScore™, DIA-NN 4D-Proteomics™, Spectronaut® 20, ICC 2.0 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ultrafleXtreme |
| Instrument Type | TOF-TOF |
| Application Domain | Universal |
| Category | Biomass Spectrometer |
| Distribution Status | Authorized Distributor (Imported) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSD-MASS |
| Quadrupole Mass Analyzer | INFICON (USA-manufactured, with Certificate of Origin & Factory Calibration Report) |
| Mass Range | Standard 1–100 amu |
| Filament | Dual Iridium-coated filaments (active/standby, software-switchable) |
| Resolution | <0.5 ppm at 40 amu |
| Scan Speed | Up to 1.8 ms/amu, step size 0.1 amu |
| Minimum Detectable Partial Pressure | 2 × 10⁻¹⁵ Torr (4 s dwell time) |
| Sample Flow Rate | Standard down to 2 SCCM |
| Response Time | <1 s at ≤2 SCCM flow |
| Precision Splitting System | Integrated high-accuracy flow splitter |
| Soft Ionization | Electron energy digitally adjustable (0–100 eV) |
| Turbo Molecular Pump | Edwards, 85 L/s, 100,000 RPM, base pressure 1 × 10⁻¹² mbar |
| Dry Scroll Pump | 20 L/s, base pressure 1 × 10⁻¹ mbar |
| Vacuum Chamber | Monolithic, weld-free heated chamber (bakeable to 150 °C) |
| Inlet Interface | 1.2 m passivated stainless steel capillary (anti-condensation & anti-clogging design) |
| Software | INFICON OEM platform (English), TCP/IP communication |
| Dimensions | 510 mm (H) × 520 mm (L) × 225 mm (W), Weight: 30 kg |
| Brand | CEAULIGHT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Producer |
| Model | CEL-PECR-TFC10 |
| Application | Dual-compartment two-electrode/three-electrode photoelectrochemical flow reactor for gas–solid–liquid triphasic catalysis |
| Construction Material | Grade 2 titanium (Ti) body, PTFE gasketing, gold-plated copper current collectors |
| Optical Window | Fused silica, Ø40 mm (effective Ø30 mm), rated to 1.0 MPa |
| Electrode Area | 20 mm × 20 mm square working electrode surface |
| Max Operating Pressure | ≤1.0 MPa |
| Volume | <10 mL |
| Compatible Electrodes | Pt counter, Ag/AgCl reference (optional), user-supplied photoanode/cathode |
| Gas Inlet | 3 mm OD stainless steel or PTFE tubing interface |
| Compliance | Designed for ASTM E2536, ISO 13485-aligned manufacturing practices |
| Brand | CEL (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Origin | Domestic (PRC) |
| Model | CEL-QMS1000 |
| Pricing | Upon Request |
| Mass Range (Configurable) | 1–100 amu (optional 1–200 amu / 1–300 amu) |
| Mass Analyzer | Quadrupole |
| Detector Options | Faraday Cup (detection limit: 4×10⁻¹³ mbar) or Secondary Electron Multiplier (SEM |
| detection limit | 3×10⁻¹⁵ mbar) |
| Ion Source | Open-type electron impact (EI) source with dual filaments |
| Resolution (10% peak height) | 0.5–2.5 amu |
| Scan Time per amu | 1 ms – 16 s |
| Inlet Pressure | Ambient (standard) |
| Inlet Temperature Control | 25–200 °C (capillary + filter assembly, dual-stage pressure reduction) |
| Vacuum System | Turbo-molecular pump + oil-free diaphragm dry pump |
| Mass Spectrometer Chamber | Stainless-steel construction with external heating jacket (max bake-out temperature: 200 °C) |
| Data Acquisition Interface | Ethernet (TCP/IP) |
| Measurement Channels | 128 parallel channels |
| Response Time | Millisecond-level |
| Detection Dynamic Range | 100% down to sub-ppb (v/v) |
| I/O Module | TTL/Analog-compatible digital input/output for synchronization with external instruments (TGA, electrochemical workstations, reactors, etc.) |
| Brand | PURSPEC Technologies |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Cell |
| Pricing | Available Upon Request |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZLS-23B |
| Pricing | Available Upon Request |
| Minimum Detectable Leak Rate | < 2 × 10⁻¹¹ Pa·m³/s |
| Warm-up Time | ~1 h |
| Response Time | ≤ 3 s |
| Maximum Operating Pressure in Mass Spectrometer Chamber | 1 × 10⁻² Pa |
| Leak Test Port | KF25 |
| Dimensions (L×W×H) | 950 × 600 × 570 mm |
| Weight | ~65 kg |
| Power Supply | AC 220 V, ~2 kW |
| Ambient Temperature Range | +5 °C to +40 °C |
| Relative Humidity | < 80 % RH |
| Electromagnetic Environment | Low-interference zone recommended |
| Brand | Chengyi / scchengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | ZLS-24D/M |
| Pricing | Available Upon Request |
| Startup Time | ≤5 min |
| Minimum Detectable Leak Rate | <1×10⁻¹¹ Pa·m³/s (Negative-Pressure Mode) |
| Response Time | ≤3 s |
| Maximum Operating Pressure in Mass Spectrometer Chamber | 1×10⁻² Pa |
| Maximum Allowable Test Port Pressure | 1000 Pa |
| Leak Test Interface | KF25 |
| Dimensions (L×W×H) | 640×550×980 mm |
| Weight | ~75 kg |
| Power Supply | 220 V ±10%, ~2 kW |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZLS-26D/M |
| Price | Upon Request |
| Minimum Detectable Leak Rate | < 5×10⁻¹² Pa·m³/s |
| Response Time | ≤ 3 s |
| Maximum Operating Pressure in Mass Spectrometer Chamber | 1×10⁻² Pa |
| Maximum Inlet Pressure at Test Port | 1000 Pa |
| Backpressure Test Duration Range | 5–30 s |
| Pump-Down & Startup Time | ≤ 5 min |
| Dimensions (W×D×H) | 640 × 550 × 980 mm |
| Weight | ~75 kg |
| Power Supply | 220 V ±10%, 50 Hz |
| Display | 12-inch Touchscreen LCD with Real-Time Leak Rate Plotting & Unit Conversion (Pa·m³/s, atm·cm³/s, mbar·L/s, Torr·L/s) |
| Data Management | Onboard Storage, Print Export, GLP-Compliant Audit Trail (via V1.0 Control Software) |
| Detection Principle | Magnetic Sector Helium Mass Spectrometry (m/z = 4) with Positive Ion Detection and Quadrupole-Assisted Peak Discrimination |
| Brand | CHINST |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Qilin-2 |
| Pricing | Upon Request |
| Brand | CORUITECH |
|---|---|
| UHPLC Integration | Integrated with CORUITECH UHPLC platform |
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | LC-MS/MS clinical workflow system |
| Mass Analyzer Compatibility | Compatible with Sciex Triple Quadrupole MS (e.g., Jasper, 4500MD, 3200MD) |
| Flow Rate Range | 0.001–8 mL/min |
| Regulatory Design Basis | Engineered for CLIA-equivalent laboratory use and ISO 15189-aligned workflows |
| Brand | China Innovation Instrument (CII) |
|---|---|
| Model | DBDI-200 |
| Ionization Principle | Dielectric Barrier Discharge (DBD) Coupled with SPME |
| Compatibility | Universal MS Interfaces (ESI, APCI, and Atmospheric Pressure Inlet Ports) |
| Origin | Zhejiang, China |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Pricing | Available upon technical consultation |
| Brand | Digena |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | TOF Mass Spectrometer |
| Model | DP-TOF 96A |
| Resolution | Mass resolution >700 (FWHM at m/z 500) |
| Sensitivity | ≤0.012 µmol (for oligonucleotide standards) |
| Mass Accuracy | ≤5×10⁻⁴ relative error (m/z) |
| Mass Stability | Relative m/z drift ≤±3×10⁻⁴ over 8 h |
| Sampling Rate | 1 GHz digitizer |
| Regulatory Status | Registered with Zhejiang Medical Device Administration (Registration No.: Zhejiang MD Registration No. 20232221555) |
| Intended Use | In vitro diagnostic (IVD) applications in clinical molecular laboratories, supporting nucleic acid-based assays including SNP genotyping, methylation analysis, and pathogen identification |
| Brand | Digena |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DP-TOF |
| Instrument Type | MALDI-TOF |
| Application Domain | Clinical Molecular Diagnostics |
| Mass Range | 4,000–10,000 Da |
| Sensitivity | ≥10:1 (S/N) |
| Resolution | ≥750 (FWHM at m/z 5,000) |
| Mass Stability | ≤±2×10⁻⁵ (over 24 h) |
| Acquisition Speed | 10 s per well |
| Laser Repetition Rate | 30 Hz |
| Mass Accuracy | <3×10⁻⁴ (relative error) |
| Brand | Dongxi Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Mass Range | Not Specified (Typical for Single Quadrupole: 10–1000 u) |
| Resolution | Unit Mass Resolution |
| Sensitivity | Not Specified (Typical: <10 fg OFN in Full Scan, S/N ≥ 50:1) |
| Scan Speed | Not Specified (Typical: Up to 10,000 Da/sec) |
| Carrier Gas Control | Electronic Pressure Control (EPC) |
| Vacuum System | Configurable Dual-Stage Pumping (Turbo + Roughing Pump Options) |
| Library Compatibility | NIST, Wiley, and Custom User Libraries |
| Interface Options | Purge & Trap, Thermal Desorption Unit (TDU), Headspace Sampler, Direct Insertion Probe (DIP) |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometer |
| Model | Ebio Reader 3700 Plus |
| Regulatory Status | Class II Medical Device (Registration No.: Tianjin NMPA Approval No. 20222220402) |
| Intended Use | Clinical Microbiology Identification, Biomarker Profiling, SNP Genotyping, Viral Peptide Detection, Foodborne Pathogen Screening |
| Compliance | Meets GB/T 19001–2016 (ISO 9001:2015), YY/T 0287–2017 (ISO 13485:2016), and relevant Chinese NMPA medical device technical requirements |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region Classification | Domestic (PRC) |
| Model | Ebio Reader™ 3700M |
| Instrument Type | Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometer |
| Resolution | ≥2500 (FWHM) |
| Sensitivity | ≥250 amol/μL Febrinopeptide Human B (S/N ≥50:1) |
| Mass Stability | ≤300 ppm relative mass drift over 8 h |
| Sampling Rate | 2 GS/s |
| Mass Accuracy | ≤200 ppm (internal calibration) |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-MS3110 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC/MS Configuration | Conventional Benchtop GC-MS |
| Mass Range | 1.5–800 Da |
| Resolution | 2 M (10% valley definition) |
| Sensitivity | 30:1 (S/N for 1 pg octafluoronaphthalene, m/z 272, in full-scan mode) |
| Scan Speed | 6000 u/sec |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1–1000 amu |
| Mass Resolution | Unit Mass Resolution (UMR) |
| Sensitivity | 100:1 (Signal-to-Noise Ratio, S/N, for m/z 69 of perfluorotributylamine, PFTBA, at 1 pg on-column) |
| Scan Speed | Up to 10,000 amu/s |
| Ion Source | Dual-Mode Electron Ionization (EI) and Programmable Positive Chemical Ionization (PCI) |
| Ion Optics | DC Compensation Voltage Tuning |
| Filament Control | Adaptive Emission Current & Electron Energy Regulation |
| GC Oven Temperature Stability | ±0.01 °C |
| Pressure/Flow Control | Third-Generation Electronic Pneumatic Control (EPC) Module |
| Optional Accessory | In-House Designed Low-Noise Mechanical Pump Enclosure |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Time-of-Flight Mass Spectrometer |
| Mass Range | 1–260 amu |
| Argon Consumption | 12 L/min |
| Analysis Time for 20 Elements | 25 s |
| Application Environment | Laboratory-Based Quantitative Elemental & Isotopic Analysis |
| Collision Cell | Integrated Octopole Collision Cell (OCC) with Mass-Independent Reaction Kinetics |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PTR-QMS3500 |
| Pricing | Upon Request |
| Mass Range | 1.5–600 amu |
| Resolution | Unit Mass Resolution |
| Response Time | 100 ms |
| Detection Limit | 100 pptv (for benzene) |
| Linear Dynamic Range | 50 pptv – 10 ppmv |
| Adjustable Inlet Flow Rate | 80–800 sccm |
| Heated Capillary Inlet Length | 1.0 m (inert, temperature-controlled up to 150 °C) |
| Drift Tube/Reaction Chamber Temperature Range | 40–150 °C |
| Primary Reagent Ion | H₃O⁺ |
| Optional Reagent Ions | NH₄⁺, O₂⁺, NO⁺ |
| Power Supply | 220 V AC |
| Dimensions (W × H × D) | 48 × 54.5 × 63 cm |
| Weight | ~100 kg |
| Remote Interface | 4–20 mA output & MODBUS RTU protocol support |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1.5–1100 amu |
| Mass Resolution | Unit Mass Resolution |
| Sensitivity | ≥2000:1 S/N for 1 pg Octafluoronaphthalene (OFN) in Electron Ionization (EI) mode |
| Scan Speed | Up to 10,000 amu/s |
| Detector | Dual-Stage Electron Multiplier with High-Energy Dynode Post-Focusing Assembly |
| Pressure Control Accuracy | ±0.001 psi |
| Column Oven | Air-heated, accommodates up to two capillary columns and three detector modules |
| Ion Source | High-Temperature Inert EI Source with dual long-life inert filaments |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Time-of-Flight Mass Spectrometer |
| Chromatography Configuration | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) |
| Model | GCxGC TOF MS 3300 |
| Mass Range | Not specified |
| Resolution | Not specified |
| Sensitivity | Not specified |
| Scan Speed | 500 spectra/sec (≥15 kHz pusher frequency) |
| Brand | Easysensor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZG-SPAMS 1000 (01) |
| Price | Upon Request |
| Particle Size Range | 0.15–9 μm (selectable modes: 0.15–5 μm or 0.3–9 μm) |
| Sample Flow Rate | 0.1–0.5 L/min |
| Particle Throughput | Up to 20,000 particles/sec |
| Laser Wavelengths | 405 nm (dual-step aerodynamic sizing), 266 nm (laser ionization), 355 nm (LIF excitation) |
| Mass Analyzer | Bipolar Time-of-Flight (TOF-MS) |
| Mass Resolution | ≥1000 (at Pb⁺, m/z 208) |
| Mass Range | 1–900 amu |
| Detection Limit | 0.001 particles/cm³ |
| Fluorescence Module | Integrated Laser-Induced Fluorescence (LIF) for biological particle pre-screening |
| Dimensions | 1160 × 780 × 560 mm |
| Weight | 140 kg |
| Brand | Easysensor |
|---|---|
| Model | ZG-SPAMS 1000 (02) |
| Origin | Jiangsu, China |
| Particle Size Range | 0.15–9 µm (airborne aerodynamic diameter) |
| Detection Rate | up to 20,000 particles/sec |
| Mass Range | 1–900 amu |
| Mass Resolution | 1000 @ Pb⁺ |
| Laser Wavelengths | 405 nm (size), 266 nm (ionization), optional 355 nm (LIF) |
| Flow Rate Options | 0.1–0.5 L/min |
| Dimensions | 1160 × 780 × 560 mm |
| Weight | 140 kg |
| Minimum Detectable Concentration | 0.001 particles/cm³ |