| Brand | Argolight |
|---|---|
| Origin | France |
| Model | Argo-LM Slide V2 |
| Substrate | AG03 borosilicate glass core in anodized aluminum carrier |
| Dimensions | 75 × 25 × 1.5 mm |
| Excitation Range | 250–650 nm (continuous) |
| Emission Range | λₑₓ + 15 nm to 800 nm (continuous) |
| Immersion Compatibility | Dry, oil (unrestricted), water |
| Objective Compatibility | ≤20× magnification |
| Photostability | Non-bleaching, lifetime-stable fluorescence patterns |
| Laser Damage Threshold | 50 GW/cm² (peak or average irradiance) |
| Pattern Precision | <10 µm in all three dimensions |
| Compliance | Aligns with ISO 21073:2019 (“Fluorescence confocal microscopes for biological imaging — Optical data”) and supports GLP/GMP-aligned quality documentation workflows |
| Brand | ARGOLIGHT (distributed by Auniontech) |
|---|---|
| Origin | Shanghai, China |
| Product Type | Fluorescence Microscope Calibration Slide & Integrated Power Sensor |
| Dimensions | 75 × 25 × 6 mm |
| Excitation Wavelength Range | 250–650 nm (CW) |
| Emission Wavelength Range | λₑₓ + 15 nm to 800 nm (broadband) |
| Power Measurement Range | 10 µW – 100 mW |
| Measurable Wavelength Range | 350–1100 nm |
| Immersion Compatibility | Dry, oil, and water immersion objectives |
| Recommended Imaging Duration per Session | < 20 min |
| Storage Conditions | 10–40 °C, 20–70 % RH |
| Damage Threshold | 50 GW/cm² (peak or average irradiance) |
| Pattern Stability | Photostable, non-bleaching embedded 2D/3D fluorescent nanostructures |
| Brand | ARGOLIGHT (distributed by Auniontech) |
|---|---|
| Origin | Shanghai, China |
| Product Type | Calibration Slide & Resolution Target |
| Dimensions | 75 × 25 × 6 mm |
| Excitation Wavelength Range | 250–650 nm (CW) |
| Emission Wavelength Range | λₑₓ + 15 nm to 800 nm (broadband) |
| Immersion Compatibility | Dry, Oil, and Water Objectives |
| Recommended Imaging Duration per Session | <20 min |
| Storage Conditions | 10–40 °C, 20–70% RH |
| Damage Threshold | 50 GW/cm² (peak or average irradiance) |
| Optical Power Measurement Range | 10 µW – 100 mW |
| Spectral Coverage for Power Detection | 350–1100 nm |
| Brand | Argolight |
|---|---|
| Model | Argo-SIM Slide V2 |
| Substrate | AG03 Glass Core in Anodized Aluminum Housing |
| Dimensions | 75 × 25 × 1.5 mm |
| Fluorescence Stability | Lifetime (Non-photobleaching) |
| Excitation Range | 250–650 nm (Continuous) |
| Emission Range | λₑₓ + 15 nm to 800 nm (Continuous) |
| Immersion Compatibility | Dry, Oil (Unrestricted), Water |
| Objective Exposure Limit | <20 min per objective |
| Storage Conditions | 10–40 °C, 20–70 % RH |
| Laser Damage Threshold | 50 GW/cm² (Peak or Average Irradiance) |
| Pattern Count per Slide | 27 Distinct Fluorescent Microstructures |
| Imaging Compatibility | All Fluorescence-Based Modalities Except STED and Multiphoton |
| Software | Argolight Daybook (Proprietary Image Analysis & QC Database Platform) |
| Brand | Auniontech (Distributor) |
|---|---|
| Origin | Shanghai, China |
| Model | Argo-WP Calibration Microplate |
| Application | QC/QA of fluorescence imaging systems (HCS/HTS/HCI) |
| Excitation Range | 350–650 nm |
| Emission Range | ~365–800 nm |
| Substrate | Patented photostable glass with embedded 3D fluorescent patterns |
| Format | 4-well aluminum plate, each well containing one 75 mm × 25 mm × 1.5 mm Argolight glass slide |
| Pattern Stability | Non-bleaching, reusable, traceable to NMIs (e.g., BAM) |
| Compliance Support | IQ/OQ/PQ protocols, ASTM E3085, ISO 17025-aligned validation workflows |
| Software | Argolight Daybook v3.x (FDA 21 CFR Part 11-ready audit trail, open-format export, documented algorithms) |
| Brand | Artec |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Structured Light 3D Scanner |
| Model | Artec Eva |
| Measurement Speed | 18 Mpts/sec |
| Accuracy | 0.1 mm |
| Maximum Scanning Range | 5 m |
| Operating System | Windows 11 |
| Weight | 0.9 kg |
| Brand | Artec |
|---|---|
| Origin | Imported (Non-Chinese) |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Structured Light 3D Scanner |
| Model | LEO |
| Measurement Speed | 35 Mpts/sec |
| Accuracy | 0.1 mm |
| Resolution | 0.2 mm |
| Max Scanning Range | 8 m |
| OS Compatibility | Windows 11 |
| Weight | 2.5 kg |
| Brand | Artec |
|---|---|
| Origin | Imported (Non-China) |
| Model | ARTEC LEO |
| Measurement Speed | 60 fps |
| Scan Accuracy | ≤ 0.1 mm |
| Resolution | 0.2 mm |
| Max Scanning Range | 8–10 m |
| Operating System Compatibility | Windows 10/11 |
| Weight | 2.5 kg |
| Onboard Processing | Yes |
| Light Source | Dual VCSEL + White LED Array |
| Texture Capture | Yes |
| Data Acquisition Rate | Up to 4 million points/sec |
| Real-time HD Display | Integrated 5.5" touchscreen |
| Power | Rechargeable internal battery (12 V DC) |
| Connectivity | Wi-Fi, Ethernet, microSD slot |
| Working Distance | 0.35–1.2 m |
| Near-Field FOV | 246 × 153 mm |
| Far-Field FOV | 843 × 527 mm |
| Calibration | Fully onboard, no external targets required |
| Brand | Artec |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Structured Light 3D Scanner |
| Model | Artec Leo |
| Measurement Speed | 60 fps |
| 3D Accuracy | ≤ 0.1 mm |
| 3D Resolution | 0.2 mm |
| Max Scanning Range | 8–10 m |
| Operating System Compatibility | Windows 10/11 (for Artec Studio) |
| Weight | 1.8 kg (scanner body only), 2.5 kg (fully configured with battery & handle) |
| Brand | ARTEC |
|---|---|
| Origin | Imported |
| Model | MICRO II |
| Measurement Speed | 1,000,000 points/sec |
| Accuracy | 5 µm |
| Resolution | 30 µm |
| Maximum Scan Volume | 200 mm (L × W × H) |
| Operating System | Windows 11 |
| Weight | 12 kg |
| Camera System | Four 13 MP RGB sensors |
| Lighting | Integrated RGB LED array |
| Targetless Scanning | Yes |
| Calibration Certificate | ISO 12836-compliant |
| Output Formats | STL, OBJ, PLY, AOP, XYZ, PDF (report), and others |
| Brand | Artec |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Laser-Based 3D Scanner |
| Measurement Speed | 2,000,000 points/sec |
| Point Accuracy | 1.9 mm @ 10 m, 2.9 mm @ 20 m, 5.3 mm @ 40 m |
| Angular Accuracy | 0.87 mm @ 10 m (18 arcsec) |
| Distance Accuracy | 1.0 mm + 10 ppm |
| Range Noise | 0.4 mm @ 10 m – 0.5 mm @ 20 m |
| Maximum Scan Range | 130 m |
| Field of View | 360° horizontal × 300° vertical |
| Texture Resolution | 36 MP triple-camera HDR system |
| Operating System | Windows 10 / 11 |
| Weight | 5.35 kg |
| Brand | Artec |
|---|---|
| Origin | Imported (EU-manufactured) |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Structured Light 3D Scanner |
| Model | ARTEC SPACE SPIDER |
| Measurement Speed | 1,000,000 points/sec |
| Accuracy | 0.05 mm |
| Maximum Scanning Volume (Single Pass) | 0.5 m³ (typical working distance: 0.18–0.3 m) |
| Operating System | Windows 11 (64-bit) |
| Weight | 0.85 kg |
| Calibration | NIST-traceable factory calibration |
| Compliance | CE, FCC, RoHS |
| Brand | Artec |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Structured Light 3D Scanner |
| Model | Artec Spider II |
| Measurement Speed | 35 Mpts/sec |
| Accuracy | 0.05 mm |
| Resolution | 0.05 mm |
| Max Scan Volume | 1 m³ |
| Operating System | Windows 10/11 x64 |
| Weight | 0.95 kg |
| Interface | Thunderbolt 3 (backward compatible with Thunderbolt 4) |
| Texture Resolution | 5 MP |
| Color Depth | 24 bpp |
| Light Source | 450 nm Blue LED (structured light), 4000 K White LED (CRI > 95) |
| FOV (Near) | 128 × 104 mm |
| FOV (Far) | 171 × 152 mm |
| Real-time Reconstruction Rate | 30 fps |
| Tracking | Markerless Geometric + Textured Surface Tracking |
| Output Formats | OBJ, PLY, STL, WRL, AOP, ASC, PTX, E57, XYZRGB, STEP, IGES, X_T, CSV, DXF, XML |
| Brand | Artec |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Structured Light 3D Scanner |
| Model | ARTEC SPIDER II |
| Measurement Speed | 30 fps |
| Accuracy | 0.05 mm |
| Resolution | 0.05 mm |
| Maximum Scanning Range | 1 m |
| Single-Frame Capture Time | 0.0002 s |
| Operating System | Windows 10/11 (64-bit) |
| Weight | 0.95 kg |
| Field of View (Near) | 128 × 104 mm |
| Field of View (Far) | 171 × 152 mm |
| 3D Distance Accuracy | 0.05 mm + 0.3 mm/m |
| Texture Resolution | 5 MP |
| Color Depth | 24 bpp |
| Light Source | 450 nm Blue LED (structured light), White LED (CRI > 95, 4000 K) |
| Interface | Thunderbolt 3 (backward compatible with Thunderbolt 4) |
| Power Supply | 24 V DC via AC/DC adapter |
| Dimensions (H×D×W) | 187 × 156 × 118 mm |
| Warranty | 2 years |
| Output Formats | OBJ, PLY, WRL, STL, AOP, ASC, PTX, E57, XYZRGB, STEP, IGES, X_T, CSV, DXF, XML |
| Brand | Artel |
|---|---|
| Origin | USA |
| Manufacturer | Artel, Inc. |
| Type | Imported Instrument |
| Model | Artel MVS |
| Pricing | Upon Request |
| Brand | Artinis |
|---|---|
| Origin | Netherlands |
| Model | CDMAM 4.0 |
| Phantom Dimensions | 240 × 162 × 3 mm (PMMA cover), 0.5 mm polished aluminum (99.5%) base |
| Gold Disc Array | 672 discs across 21 size steps (diameters: 0.08–2.0 mm), 16 thickness levels per diameter |
| Reference Discs | 43 additional calibration discs |
| PMMA Plates Included | 4 × 10 mm (surface polish, thickness tolerance ±0.1 mm) |
| Software | CDCOM-based CDMAM 4.0 Image Analysis Software (v4.x), DICOM-compatible, Windows 7/8/10, USB port required |
| Compliance | EU Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis (4th ed.), NHSBSP Equipment Report 0604 (3rd ed., Apr 2009), IEC 61223-3-2, EUREF CDCOM protocol |
| Brand | Artinis |
|---|---|
| Country of Origin | Netherlands |
| Model | CDRAD 2.0 |
| Phantom Type | Contrast-Detail Resolution Test Object for Diagnostic Radiology |
| Material | PMMA (Polymethyl Methacrylate) |
| Hole Depth Range | 0.3–8.0 mm ±0.03 mm (15 logarithmic steps) |
| Hole Diameter Range | 0.3–8.0 mm ±0.03 mm (15 logarithmic steps) |
| Application Scope | Fluoroscopy, Digital Subtraction Angiography (DSA), General Radiography, Mammography (with appropriate beam filtration and geometry) |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | PDI-X00MD |
| Measurement Principle | Laser-based phase Doppler anemometry (PDA) / Phase Doppler Particle Analysis (PDPA) |
| Velocity Range | −100 to +300 m/s |
| Droplet Size Range | 0.5–2000 µm |
| Size Accuracy | ±0.5 µm |
| Size Resolution | 0.5 µm |
| Velocity Accuracy | ±1% of reading |
| Volumetric Flow Rate Accuracy | ±15% |
| Signal Processor Bandwidth | 5–150 MHz |
| Minimum Transit Time | 100 ns |
| Maximum Sampling Rate | 320 MHz (integrated) |
| Minimum SNR | −6 dB |
| Max Data Throughput | 100,000 events/s |
| Operating Systems | Windows XP/2000, Linux 2.4 kernel |
| Software Architecture | Client-server over LAN/internet |
| Data Export Formats | MATLAB (.mat), Excel (.csv), ASCII |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-990SWIR-TEC |
| Spectral Range | 400–1700 nm |
| Sensor Type | InGaAs (Indium Gallium Arsenide) |
| Cooling | Thermoelectrically Cooled (TEC) |
| Category | SWIR Imaging Camera |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Model No. | 1-6393-01 |
| Measurement Range | 6.0 to 99,999.9 rpm |
| Resolution | 0.1 rpm |
| Accuracy | ±(0.01% of reading + 1 digit) |
| Sampling Interval | 1.0 to 10.0 seconds |
| Measurement Distance | 50–300 mm (with reflective tape) |
| Auto-ranging | Yes |
| Operating Temperature | 5–40 °C |
| Display | 6-digit LCD |
| Dimensions (W×H×D) | 58 × 28 × 122 mm |
| Weight | Approx. 140 g |
| Power Supply | Four AA batteries (included) |
| Accessories | Ten reflective tapes |
| Brand | AS ONE |
|---|---|
| Model | C6-4024-11 |
| Material | ABS Resin |
| Alarm Volume | ≥70 dB |
| Weight | ≈75 g |
| Power Supply | 1 × AAA battery (DC 1.5 V, included) |
| Dimensions | 82 × 23.2 × 76 mm |
| Max Timer Setting | 99 min 59 sec |
| Min Timer Setting | 1 sec |
| Repeat Function | Yes |
| Origin | China |
| Manufacturer | AS ONE Co., Ltd. |
| Brand | AS ONE |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Manufacturer |
| Country of Origin | China (Domestic) |
| Model No. | 1-5812-01 |
| Temperature Range | -50 to +1300 °C |
| Resolution | 0.1 °C / 1 °C (switchable) |
| Display | 3.5-digit LCD with backlight |
| Accuracy | ±0.3% rdg + 1 °C (-50 to +1000 °C) |
| Sampling Rate | 2.5 readings/sec |
| Power Supply | 1 × 006P (9 V) battery (included) |
| Dimensions | 155 × 65.5 × 35 mm |
| Weight | 177 g |
| Thermocouple Type | K-type |
| Functions | Data Hold, Max Value Storage & Recall, Auto-Hold Trigger |
| Brand | AS ONE |
|---|---|
| Model | 2-3799-01 |
| Type | Digital Thermometer (Waterproof) |
| Display | LED |
| Dimensions | 70 × 40 × 175 mm |
| Compliance | RoHS 2 (EU Directive 2015/863) |
| Origin | China |
| Manufacturer | AS ONE (AS ONE Co., Ltd.) |
| Instrument Category | Temperature Measuring Instrument |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | D2600 |
| Flow Control Accuracy | ±1% of reading (standard gas) |
| Standard Gas Flow Range | 0–10 sccm |
| Auxiliary Gas Flow Range | 0–4 SLPM |
| Dilution Gas Flow Range | 0–2000 sccm |
| Dilution Ratio Range | 1:10 to 1:2500 |
| Control Stability | <±0.1% FS |
| Repeatability | <0.2% |
| Operating Temperature | 0–45°C |
| Storage Temperature | −20–75°C |
| Dimensions | 150 × 120 × 170 mm |
| Weight | 1.5 kg |
| Power Supply | 24 VDC, 15 W |
| Battery | Integrated Li-ion |
| Communication | Ethernet ×1, RS232/RS485 |
| Display | 4.3″ touchscreen |
| Gas Interface | 1/8″ Swagelok |
| Wetted Materials | 316 stainless steel, FEP, FKM, Viton |
| Relative Humidity | 5–95% RH (non-condensing) |
| Brand | ASIDA |
|---|---|
| Model | 7060 |
| Measurement Range (X×Y×Z) | 700 mm × 600 mm × 200 mm |
| Granite Base Material | Grade 0 Natural Granite |
| Linear Accuracy (X/Y) | ≤ (3 + L/200) µm |
| Repeatability | ≤ ±0.003 mm |
| Optical Magnification | 0.75×–5× Objective + 1× Eyepiece → Total 30×–230× |
| Encoders Resolution | ≤ 0.001 mm |
| Light Source | Ring-shaped LED Cold Illumination |
| Drive System | Panasonic Servo Motors (XYZ) |
| Software | AISDA VMA 3.00.01 (Multi-language: Simplified Chinese, Traditional Chinese, English) |
| Output Formats | DXF, Excel, Word |
| Compliance | Designed for ISO 10360-2, ISO 14253-1, and GB/T 16857.2 metrological traceability frameworks |
| Environmental Requirements | 20 ± 2 °C, 45–75% RH, Vibration < 0.002 g (<15 Hz) |
| Brand | ASIDA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 7060 Series |
| Price Range | USD 14,000 – 72,000 (FOB Guangdong) |
| Measurement Range (X×Y×Z) | 700 mm × 600 mm × 200 mm |
| Granite Base Grade | ISO 8540 Grade 00 |
| Encoder Resolution | ≤1 µm |
| XY Axis Linear Accuracy | ±(3 + L/200) µm (L in mm) |
| Repeatability | ≤±3 µm |
| Optical Magnification | 0.75×–5× Objective + 1× Eyepiece → Total 30×–230× |
| Working Distance | 82 mm |
| Stage Load Capacity | 30 kg |
| Software | AISDA VMA 3.00.01 (Multilingual: EN/TC/SC) |
| Compliance | ISO 10360-7, GB/T 16857.7, JJF 1306–2011 |
| Optional Accessories | NAVITAR Telecentric Lens, Renishaw MCR20 Trigger Probe, KEYENCE LJ-V Series Laser Displacement Sensor |
| Brand | ASIDA |
|---|---|
| Model | 8070 |
| Measurement Range (X×Y×Z) | 800 mm × 700 mm × 200 mm |
| Granite Base & Column | Grade-0 Natural Granite |
| Motion System | Air-bearing Guideways (X/Y), Panasonic Servo Motors |
| Optical Magnification | 0.75×–5× Objective + 1× Eyepiece → Total 30×–230× |
| Encoders | ≤0.001 mm Resolution |
| Linear Accuracy | ≤(3 + L/200) µm (L in mm) |
| Repeatability | ≤±0.003 mm |
| Illumination | Ring-type LED Cold Light Source |
| Software | AISDA VMA 3.00.01 (Trilingual: Simplified Chinese, Traditional Chinese, English) |
| Output Formats | DXF, Excel, Word |
| Compliance | Designed for ISO 10360-2 & GB/T 16857.2 compliant geometric metrology workflows |
| Environmental Requirements | 20 ±2 °C, 45–75% RH, Vibration <0.002 g (<15 Hz) |
| Optional Accessories | NAVITAR Metrology Lens, Renishaw TP20 Trigger Probe Kit, KEYENCE LJ-V Series Laser Displacement Sensor |
| Brand | ASIDA |
|---|---|
| Model | Manual Vision Measuring Machine (2010/3020/4030/5040 Series) |
| Measurement Principle | Optical Coordinate Metrology with CCD Imaging |
| Base Material | Natural Granite |
| Motion System | Precision Linear Rolling Guides + Friction-Driven Stage |
| Illumination | Adjustable Ring LED Cold Light Source |
| Optics | Manual Zoom Objective (0.7×–4.5× or 0.7×–5.0×) + Interchangeable Eyepieces (0.5×, 1×, 2×) |
| Encoder Resolution | 1 µm |
| XY Axis Accuracy | (3 + L/200) µm (L in mm) |
| Repeatability | ≤ ±3 µm |
| Z-Axis Travel | 150–200 mm |
| XY Travel Range | 200×100 mm to 500×400 mm |
| Stage Load Capacity | 25 kg |
| Working Distance | 90 mm |
| Software | ASIDA VMM3.0D (Multilingual: English, Simplified Chinese, Traditional Chinese) |
| Compliance | Designed for ISO 10360-7 and GB/T 16857.7 alignment with geometric dimensioning and tolerancing (GD&T) workflows |
| Brand | ASIDA |
|---|---|
| Origin | Guangdong, China |
| Model | ASIDA6050A, ASIDA7060A, ASIDA8070A |
| Measurement Range (X×Y×Z) | 600×500×200 mm |
| Optical Magnification | 0.75×–5× Objective + Digital Zoom → Total Magnification: 30×–230× |
| Encoders Resolution | ≤0.001 mm |
| X/Y Linear Accuracy | (3 + L/200) µm (L in mm) |
| Repeatability | ≤±0.003 mm |
| Worktable Size | 650×550 mm / 750×650 mm / 850×750 mm |
| Max Load Capacity | 30 kg |
| Working Distance | 82 mm |
| Software | AISDA MEASURE VMA 3.00.01 (Trilingual: Simplified Chinese, Traditional Chinese, English) |
| Output Formats | DXF, Excel (.xlsx), Word (.docx) |
| OS Compatibility | Windows XP Pro, Windows 7 |
| Minimum PC Requirements | Dual-Core CPU, ≥2 GB RAM, ≥320 GB HDD |
| Power Supply | 220 V AC, 50 Hz |
| Environmental Conditions | Temp. 20 ±2 °C, Humidity 45–75 % RH, Vibration <0.002 g (<15 Hz) |
| Optional Accessories | NAVITAR Metrology Lens (USA), RENISHAW TP20 Trigger Probe (UK), KEYENCE LJ-V Series Laser Displacement Sensor (Japan) |