Measurement Instruments
Filter
Showing 871–900 of 1342 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Max Capacity | 220 g / 121 g (dual-range) |
| Readability | 1 mg / 0.1 mg |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (U=1%, k=2, typ.) | 8.2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| Pan Dimensions (W×D) | 78 mm × 73 mm |
| External Dimensions (H×W×D) | 292 mm × 195 mm × 456 mm |
| User Management | Password-protected, unlimited users, role-based permissions |
| Software Compatibility | LabX™ (21 CFR Part 11 compliant) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg (certified: 1 mg) |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (U=1%, k=2, typ.) | 8.2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| Pan Dimensions (W×D) | 78 mm × 73 mm |
| External Dimensions (H×W×D) | 292 mm × 195 mm × 456 mm |
| User Management | Password-protected, unlimited users, role-based permissions |
| Compliance | 21 CFR Part 11–ready (with LabX), USP <41> compliant, GLP/GMP-supportive |
| Electrostatic Detection | Not supported |
| Series | XPR Essential |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g / 81 g (dual-range) |
| Readability | 0.1 mg / 0.01 mg |
| Repeatability (typ.) | 0.01 mg |
| Minimum Weight (U=1%, k=2, typ.) | 2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 20 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B, Ethernet, Bluetooth (optional) |
| Pan Dimensions (W×D) | 78 mm × 73 mm |
| Dimensions (H×W×D) | 292 mm × 195 mm × 456 mm |
| Certified Readability | 1 mg |
| Series | XPR Essential |
| Regulatory Compliance | 21 CFR Part 11–compatible (with LabX), USP <41>, ISO/IEC 17025 support |
| User Management | Password-protected, unlimited users, role-based permissions |
| Static Detection | Not integrated |
| Industry Applications | Pharmaceuticals, Chemicals, Food & Beverage, Quality Control Laboratories |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g / 121 g |
| Readability | 0.1 mg / 0.01 mg |
| Repeatability (typ.) | 0.01 mg |
| Minimum Weight (U=1%, k=2, typ.) | 2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 20 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, Fully Automatic (FACT) |
| Interfaces | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| Display | 7-inch color TFT touchscreen |
| User Management | Password-protected, unlimited users, configurable permissions |
| Pan Dimensions (W × D) | 78 mm × 73 mm |
| Dimensions (H × W × D) | 292 mm × 195 mm × 456 mm |
| Certified Readability | 1 mg |
| Electrostatic Detection | Not supported |
| Product Line | XPR Essential |
| Regulatory Compliance | 21 CFR Part 11–ready (with LabX software), USP <41> compliant, GLP/GMP traceable operation |
| Recommended Industries | Pharmaceuticals, Chemicals, Food & Beverage |
| Key | Brand: METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR226DRQ |
| Type | Analytical Balance |
| Max Capacity | 220 g |
| Readability | 2 µg |
| Accuracy | 5 µg |
| Repeatability | 0.01 mg |
| Calibration | Internal motorized calibration |
| Application | Automated gravimetric dispensing and quantitative sample preparation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR26/56 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg |
| Repeatability | 0.0003 mg |
| Calibration | Automatic (proFACT) |
| Compliance | USP Chapter <41> & <1251>, ISO/IEC 17025, GWP® Verified |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (U=1%, k=2, typ.) | 8.2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Weighing Pan Dimensions (W × D) | 78 mm × 73 mm |
| External Dimensions (H × W × D) | 292 mm × 195 mm × 456 mm |
| Certified Readability | 1 mg |
| Connectivity | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| User Management | Password-protected, unlimited users, configurable permissions |
| Compliance | 21 CFR Part 11–compatible (via LabX), USP <41> compliant, GLP/GMP-ready |
| Series | XPR Essential |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Ultra-Micro Balance |
| Model | XPR3DUE/AC |
| Maximum Capacity | 3.2 g / 1.2 g |
| Readability | 0.01 mg / 0.001 mg |
| Repeatability (typ.) | 0.0008 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 1.6 mg |
| Stabilization Time | 6 s |
| Pan Dimensions (W × D) | 32 mm × 32 mm |
| Dimensions (H × W × D) | 196 mm × 195 mm × 478 mm |
| Built-in Calibration | FACT (Fully Automatic Calibration Technology) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B, Ethernet, Bluetooth (optional) |
| 21 CFR Part 11 Compliance | Yes (with LabX software) |
| User Management | Unlimited users with role-based permissions |
| Leveling Guidance | Integrated digital level indicator |
| Static Detection | Not automated |
| Minimum Weight (U=1%, k=2, typ.) | 0.16 mg |
| Certified Readability | 1 mg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR603SN |
| Maximum Capacity | 610 g |
| Readability | 1 mg |
| Repeatability | 0.5 mg |
| Calibration | Internal |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible (via LabX), ISO/IEC 17025 support |
| Sample Pan Type | SmartPan™ |
| Leveling System | LevelMatic™ |
| Connectivity | Ethernet, USB, RS232 |
| Data Integrity | LabX-integrated, audit trail enabled, electronic signature support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS Micro Balance |
| Readability | 0.001 mg / 0.01 mg (dual range) |
| Max Capacity | 0.8 g / 3.1 g (dual range) |
| Repeatability (sd) | 0.0008 mg / 0.006 mg |
| Linearity Error | ±0.01 mg |
| Typical Stabilization Time | 6 s |
| Pan Diameter | Ø27 mm |
| Design | Separated weighing unit and display/control unit |
| Built-in Applications | Weighing, Statistics, Formulation, Counting, Percentage, Density, Dynamic Weighing |
| Compliance | GWP® Excellence integrated risk-based validation support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Precision Balance |
| Model Series | XS |
| Sensor Technology | MonoBloc HighSpeed single-module electromagnetic force compensation sensor |
| Readability | 0.1 mg to 1 g |
| Max Capacity | 210 g to 100 kg |
| Repeatability (sd) | 0.0008 mg to 0.6 g |
| Linearity Error | 0.002 mg to 0.3 g |
| Stabilization Time | 1.2 s to 1.5 s |
| Pan Dimensions (W×D) | 127×127 mm to 280×360 mm |
| Protection Class | IP54 |
| Construction | Full-metal monocoque frame with rounded edges and seamless, flat surfaces |
| Interface Options | RS232 (standard), plus modular slot for Bluetooth, Ethernet, PS/2, LocalCAN, or MiniMettler |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS Series |
| Instrument Type | Analytical Balance |
| Capacity Range | 41–220 g (dual-range and single-range variants) |
| Readability | 0.01 mg to 0.1 mg |
| Repeatability (sd) | 0.02 mg to 0.1 mg |
| Linearity Error | ≤ 0.2 mg |
| Typical Stabilization Time | 1.5–4 s |
| Pan Dimensions | 78 × 73 mm (standard) |
| Key | Brand: METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS203S |
| Maximum Capacity | 210 g |
| Readability | 0.001 g |
| Linearity (typ.) | ±0.002 g |
| Repeatability (at 200 g) | 0.5 mg |
| Minimum Weight (USP, typ.) | 1 g |
| Stabilization Time | 1.5 s |
| Pan Dimensions (D×W) | 127 mm × 127 mm |
| Overall Dimensions (H×W×D) | 276 mm × 198 mm × 305 mm |
| Weighing Chamber | None (open design with SmartPan™) |
| Calibration | Internal, FACT (Fully Automatic Calibration Technology) |
| Compliance | ISO/IEC 17025, USP <41> & <1251>, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS4001S |
| Instrument Type | Precision Balance |
| Maximum Capacity | 4.1 kg |
| Readability | 0.1 g |
| Linearity (typ.) | ±60 mg |
| Repeatability (typ.) | 40 mg |
| Repeatability (2 kg test weight) | 80 mg |
| Minimum Weight (USP, typ.) | 82 g |
| Stabilization Time | 0.8 s |
| Calibration | Internal / FACT |
| Pan Dimensions (D×W) | 190 mm × 223 mm |
| Housing Dimensions (H×W×D) | 96 mm × 195 mm × 257 mm |
| Display Height | 16 mm digits |
| Legal for Trade | No |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS8001S |
| Maximum Capacity | 8.1 kg |
| Readability | 0.1 g |
| Linearity (typ.) | ±0.1 g |
| Repeatability (typ.) | 40 mg |
| Repeatability (with 5 kg test weight) | 80 mg |
| Minimum Weight (USP, typ.) | 82 g |
| Stabilization Time | 1 s |
| Calibration | Internal / FACT |
| Pan Dimensions (D×W) | 190 mm × 223 mm |
| Housing Dimensions (H×W×D) | 96 mm × 194 mm × 257 mm |
| Display Digit Height | 16 mm |
| Legal for Trade | No |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Model | XSR |
| Compliance | ISO/IEC 17025, USP <41>, USP <1251>, ASTM E898, GLP/GMP-ready |
| Software | LabX®-compatible, FDA 21 CFR Part 11 compliant (with optional audit trail license) |
| Weighing Range | Up to 520 g (model-dependent) |
| Readability | 0.001 mg to 0.01 mg |
| Repeatability (sd) | ≤ 0.0006 mg (typical) |
| Calibration | Internal & external, fully traceable to SI units |
| Draft Shield | Motorized automatic draft shield with SmartDoor™ logic |
| Pan Design | SmartGrid™ perforated weighing pan |
| Connectivity | USB, RS232, Ethernet, Bluetooth (optional) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XSR Precision Balance |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025, USP <41>, ASTM E898, GLP/GMP-ready |
| Weighing Principle | Electromagnetic Force Compensation (EMFC) |
| Readability | Down to 0.1 mg–1 mg (model-dependent) |
| Repeatability | ≤ 0.0002 g (at full capacity) |
| Internal Calibration | FACT (Fully Automatic Calibration Technology) with motorized weights |
| Environmental Compensation | Built-in temperature and drift monitoring |
| Connectivity | 4× USB-A, 1× Ethernet (LAN), optional RS-232 |
| Data Security | User-level password protection, audit trail enabled, 21 CFR Part 11 compliant configuration available |
| SmartPan™ | Patented draft shield-free weighing pan design reducing air current interference |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Analytical Balance |
| Model Range | XSR105, XSR105DU, XSR205DU, XSR64, XSR104, XSR204, XSR204DR, XSR304, XSR225DU |
| Maximum Capacity | 61–320 g (full range) |
| Readability | 0.01 mg (high-resolution models) to 1 mg |
| Repeatability (sd, 5% load) | 0.008–0.04 mg |
| Stabilization Time | 1.5–3 s |
| Minimum Weight (USP <41> compliant) | 16–82 mg |
| Calibration | proFACT — fully automatic, time- and temperature-triggered internal calibration |
| Display | Full-color touchscreen with multilingual UI (including English) |
| Connectivity | 4 × USB ports, 1 × Ethernet (LAN) port |
| Environmental Control | Active Temperature Control (ATC™), LevelControl™ leveling system, SmartGrid™ draft shield grid |
| Compliance | USP <41>, GWP® Verified, GLP/GMP-ready audit trail support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XSR105 |
| Instrument Type | Precision Balance |
| Readability | 1 mg |
| Construction | Full-metal corrosion-resistant housing |
| Pan System | SmartPan™ with integrated spill containment tray |
| Draft Shield Operation | Optional — door can remain open during weighing in fume hoods or under laminar flow |
| Compliance | Designed for GLP/GMP environments |
| Brand | Micro-Hybrid |
|---|---|
| Origin | Germany |
| Model | INC5502D |
| Measurement Range | Longitudinal (Roll): ±180° (configurable to 0°–360°) |
| Lateral (Pitch) | ±85° (configurable to 95°–265°) |
| Resolution | 0.01° |
| Sampling Rate | 200 Hz |
| Supply Voltage | 9–32 V DC |
| Protection Rating | IP67 / IP69K |
| Weight | ~120 g |
| Output Interfaces | Analog (I/U), CANopen, SAE J1939 |
| Brand | Mitutoyo |
|---|---|
| Origin | Japan |
| Model | 513-405E |
| Graduation | 0.002 mm |
| Range | 0–10 mm |
| Full-Scale Deflection | 10 mm |
| Contact Force | ≤0.3 N |
| Accuracy | ±3 µm (per JIS B 7507 and ISO 10360-2) |
| Dial Face | Anti-glare crystal with scratch-resistant coating |
| Base | Synthetic sapphire jewel seat |
| Bearing System | Precision jewel bearings |
| Standard Probe Tip | Tungsten carbide |
| Brand | MPD / Micro Photon Devices |
|---|---|
| Origin | Italy |
| Model | PDM Series |
| Wavelength Range | 400–1000 nm |
| Active Area Diameters | 20 µm, 50 µm, 100 µm |
| Peak Detection Efficiency | 49% @ 550 nm |
| Dark Count Rate | <25 cps (20 µm), <50 cps (50 µm), <250 cps (100 µm) |
| Timing Resolution (FWHM) | <35 ps (typ.), <50 ps (max.) |
| Dead Time | <77 ns |
| Afterpulsing Probability | 0.1–3% |
| Cooling | Thermoelectric (Peltier) |
| Fiber Coupling Option | Yes, coupling efficiency >80% |
| Solar Radiation Tolerance | Designed for continuous ambient daylight exposure |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MS+ |
| Price | Upon Request |
| Temperature Range | -32 to 530 °C |
| Optical Resolution | 20:1 |
| Spot Size at 20 | 1: ≥13 mm |
| Emissivity Adjustment | 0.100–1.000 (0.001 step) |
| Response Time | 300 ms |
| Accuracy | ±1% or ±1 °C (0–530 °C) |
| Display Features | Max/Min Hold, Backlit LCD, High/Low Temperature Alarm |
| Safety Certification | Ex ia II C T4 (Intrinsically Safe) |
| Power Supply | 9 V Alkaline Battery |
| Brand | MSR |
|---|---|
| Origin | Switzerland |
| Model Variants | MSR63, MSR64, MSR83, MSR84 |
| Sensor Type | Integrated temperature and/or relative humidity |
| Temperature Range | –30 °C to +70 °C |
| Relative Humidity Range (MSR64/MSR84) | 0–98 %RH (at –30 °C to +70 °C) |
| Temperature Accuracy | ±0.5 °C |
| RH Accuracy | ±3 %RH |
| Resolution | 0.1 °C |
| Logging Interval | 1 min |
| Storage Capacity | 16,000 points (MSR63/MSR83), 32,000 points total (16,000 temp + 16,000 RH for MSR64/MSR84) |
| Battery | 3.0 V lithium cell |
| Battery Life | ~12 months |
| Enclosure Rating | IP54 |
| Dimensions (MSR63/MSR64) | 39 × 8 × 58 mm, 18 g |
| Dimensions (MSR83/MSR84) | 43 × 10 × 80 mm, 30 g |
| Interface | USB 2.0 |
| Compliance | DIN 12830, FDA 21 CFR Part 11 |
| Calibration | Factory-provided 6-point certificate included |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LFR MOD 4EC |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Type | Telescope-Style Laser Rangefinder |
| Operating Principle | Pulsed Time-of-Flight Laser Ranging |
| Measurement Range | 16 – 4000 m |
| Distance Accuracy | ±1 m |
| Telescope Magnification | 7× (fixed optical path, optimized for long-range target acquisition) |
| Integrated Sensor Outputs | Distance, Azimuth (0–6400 mils / 360°), Elevation Angle (±60°), and Velocity (derived via sequential ranging) |
| Environmental Rating | IP66/IP67 |
| Laser Class | Class 1 (IEC 60825-1:2014) |
| Wavelength | 905 nm |
| Beam Divergence | 1 mrad |
| Response Time | 0.5 s |
| Power Supply | 9 V DC (standard alkaline or rechargeable battery pack) |
| Shock & Vibration Resistance | MIL-STD-810G compliant |
| RF Immunity | EN 61326-1:2013 compliant |
| Operating Temperature | −30 °C to +60 °C |
| Dimensions | 230 × 210 × 95 mm |
| Weight | 2.6 kg |
| Interface | RS-232 (asynchronous, 9600 bps default, configurable) |
| Brand | NIREOS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GEMINI-2D |
| Pricing | Upon Request |
| Light Source Frequency | Dual-Frequency |
| Wavelength Range | 400 nm – 2300 nm |
| Brand | OGP |
|---|---|
| Origin | USA |
| Model | SmartScope ZIP 250 |
| Measurement Range (X×Y×Z) | 250 × 150 × 200 mm |
| Footprint (L×W×H) | 740 × 540 × 800 mm, 120 kg |
| Computer Dimensions (L×W×H) | 760 × 450 × 560 mm, 23 kg |
| Encoded Scale Resolution | 0.1 µm |
| Drive System | DC Servo Motors |
| Motion Speed | 150 mm/s (X/Y), 100 mm/s (Z) |
| Worktable Load Capacity | 25 kg |
| Zoom Lens | Patented 5:1 AccuCentric™ Auto-Calibrating Zoom with Up to 10 Calibration Positions |
| Objective Lens | 1.0× |
| Extension Tube | 1.0× |
| Illumination | Calibrated Green LED Backlight, Coaxial White LED Surface Light, SmartRing™ White LED Ring Light |
| Camera | 1/2″ High-Resolution Color CCD, 768 × 494 Pixel Array |
| Image Processing | 10:1 Sub-Pixel Edge Detection, 256 Gray Levels |
| Power Requirement | 115/230 VAC, 50/60 Hz, Single-Phase, 700 W |
| Environmental Specifications | Operating Temperature 15–30 °C, Controlled Measurement Environment: 18–22 °C ±1 °C/hour, Humidity 30–80 % RH (non-condensing), Vibration < 0.001 g below 15 Hz |
| Software | OGP MeasureMind® 3D Multisensor Metrology Software |
| Warranty | 1 Year |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | AX Series |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g to 8200 g |
| Readability | 0.1 mg to 0.1 g |
| Calibration | Internal (AutoCal™) or External |
| Repeatability | 0.1 mg to 0.1 g |
| Linearity Error | ±0.0002 g to ±0.2 g |
| Stabilization Time | ≤1.5 s to ≤3 s |
| Accuracy Class | ISO 9001-certified manufacturing |
| Operating Temperature | 10–30 °C |
| Humidity Range | ≤80% RH at ≤30 °C, linearly decreasing to 50% RH at 40 °C |
| Display | 4.3-inch WQVGA capacitive touchscreen (10.9 cm diagonal) |
| Interface | RS-232, dual USB (front-facing for USB flash drive, rear for PC connection) |
| GLP/GMP Compliance | Real-time clock, user-defined audit trail metadata (sample ID, project name, operator), time-stamped data export |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | i-D33P60B1R1ZH |
| Pricing | Upon Request |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | i-D33P300B1V3ZH |
| Pricing | Upon Request |