Near Infrared Spectrometer
Filter
Showing 1–30 of 97 results
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AnalyzeIT Wet Process Analyzer |
| Price Range | USD 140,000 – 280,000 (based on CIF terms) |
| Instrument Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | FTPA2000-260 |
| Type | Online Analyzer |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Spectral Resolution | 1–128 cm⁻¹ (in 2× steps) |
| Optical Path Difference (OPD) Scan Speed | 1 cm/s |
| Wavenumber Repeatability | 0.002 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Wavenumber Reproducibility | 0.04 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Absorbance Linearity Error | ≤0.1% of peak response |
| SNR (1 scan, 16 cm⁻¹, room-temp InGaAs) | ≥15,000:1 (29 µabs @ 0 abs) |
| Sampling Modes | Transmission / Diffuse Reflectance / Transflectance |
| Detector Options | Thermoelectrically Cooled InAs or InGaAs |
| Channel Count | 8 independent optical channels (8-in/8-out) |
| Fiber Interface | SMA-905 |
| Fiber Types | Low-OH silica core (300–600 µm), multi-fiber bundle (650 µm, NA 0.22–0.28) |
| Max Fiber Length | 100 m (solids), 300 m (liquids) |
| Software | Horizon MB, FTSW100 |
| Compliance | FDA 21 CFR Part 11, GMP/GLP-ready, OPC, Modbus TCP |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | FTPA2000-PH40 |
| Instrument Type | Online |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Spectral Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | FTSW100, Horizon MB |
| Optical Path Difference (OPD) Scan Speed | 1 cm/s |
| Resolution Options | 1–128 cm⁻¹ (in powers of two) |
| Wavenumber Repeatability | 0.002 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Wavenumber Reproducibility | 0.04 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Absorbance Linearity | ±0.1% of peak response |
| SNR (1 scan, 16 cm⁻¹, room temp) | ≥15,000:1 (extended InGaAs detector) |
| Long-term Spectral Stability | ≤2%/°C drift (4000–10000 cm⁻¹) |
| Beam Splitter Material | BK7 optical glass |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-CH10 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Compliance | AOCS Cd 1e-01 (IV determination) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-CH20 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Compliance | Designed for GLP/GMP-aligned workflows, supports ASTM E1655 and ISO 12099 data handling conventions |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-CH80 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Sample Throughput | Non-destructive, sub-10-second analysis per PET container |
| Calibration Basis | Pre-installed quantitative models derived from >150 real-world PET bottle measurements |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MB3600-HP10 |
| Instrument Type | Laboratory |
| Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-PH |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform |
| Spectral Range | 3800–14000 cm⁻¹ |
| Spectral Resolution | Adjustable from 1 to 64 cm⁻¹ (step size: 2 cm⁻¹), nominal resolution < 0.7 cm⁻¹ |
| Signal Sampling | 24-bit ADC |
| SNR (60 s, 16 cm⁻¹, peak response) | >100,000:1 (DTGS), >600,000:1 (Extended InGaAs) |
| Frequency Accuracy (@ 7300 cm⁻¹) | < 0.06 cm⁻¹ |
| Frequency Reproducibility (@ 7300 cm⁻¹) | < 0.006 cm⁻¹ |
| Absorbance Reproducibility (methanol reference) | < 0.002 AU |
| Short-term Stability (@ 8000 cm⁻¹) | < 0.09 % |
| Temperature Stability (@ 8000 cm⁻¹) | < 1 %/°C |
| Sampling Modes | Transmission, Diffuse Reflectance, Fiber-Optic Probe |
| Software | Horizon MB Chemometrics Suite |
| Regulatory Compliance | 21 CFR Part 11, cGMP IQ/OQ Protocols Included |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | PIR3502, PFO3372, PUV3402 |
| Operating Principle | In-situ, Online & Portable |
| Spectral Ranges | UV (190–400 nm), VIS (400–700 nm), NIR (700–2500 nm), IR (2.5–25 µm) |
| Wavelength Channels | Up to 8 discrete optical bands |
| Integration | Compatible with VN2300 Analyzer Network |
| Sampling Interface | Direct path (PIR3502/PUV3402) and fiber-optic probe (PFO3372) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | TALYS ASP500-OH |
| Instrument Type | Online |
| Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Detector Options | InGaAs 2.1 (4550–10500 cm⁻¹), InGaAs 2.1 TE-cooled (4750–10500 cm⁻¹), InGaAs 2.6 (4000–10000 cm⁻¹) |
| Light Source | Quartz Halogen Lamp with Electronic Stabilization |
| Laser Reference | Solid-State Laser |
| Spectral Resolution (Adjustable) | 1–64 cm⁻¹ |
| Wavenumber Reproducibility (@7300 cm⁻¹) | <0.006 cm⁻¹ |
| Wavenumber Accuracy (@7300 cm⁻¹) | <0.06 cm⁻¹ |
| Sampling Modes | Transmission, Diffuse Reflectance, Transflectance |
| Data Sampling Interval | Better than 0.7 cm⁻¹ |
| Software Suite | Horizon MB, Quantify, PLSPlus, PLS-IQ, Unscrambler |
| Communication Protocols | Modbus TCP (Ethernet), RS232/RS485 (via converter), OPC DA (Ethernet), CANopen (via USB-to-CAN adapter) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | TALYS ASP500-Oleochemicals |
| Instrument Type | Online |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Detector Options | InGaAs 2.1 (4550–10500 cm⁻¹), InGaAs 2.1 TE-cooled (4750–10500 cm⁻¹), InGaAs 2.6 (4000–10000 cm⁻¹) |
| Light Source | Quartz Halogen Lamp with Electronic Stabilization |
| Interferometer | Solid-State Laser Referenced |
| Spectral Resolution (Adjustable) | 1–64 cm⁻¹ |
| Wavenumber Reproducibility (@7300 cm⁻¹) | <0.006 cm⁻¹ |
| Wavenumber Accuracy (@7300 cm⁻¹) | <0.06 cm⁻¹ |
| Sampling Modes | Transmission, Diffuse Reflectance, Transflectance |
| Data Sampling Interval | Better than 0.7 cm⁻¹ |
| Communication Protocols | Modbus TCP (Ethernet), RS232/RS485 (via converter), OPC DA (Ethernet), CANopen (via USB-to-CAN adapter) |
| Chemometrics Software | Horizon MB, Quantify, PLSPlus, PLSIQ, Unscrambler |
| Brand | Anasys |
|---|---|
| Origin | USA |
| Model | nanoIR2-FS |
| Instrument Type | Laboratory Benchtop System |
| Core Principle | Photothermal Induced Resonance (PTIR) Coupled with Atomic Force Microscopy (AFM-IR) |
| Spectral Range | 1000–4000 cm⁻¹ (Standard Tunable Quantum Cascade Laser Source) |
| Spatial Resolution | <10 nm |
| Spectral Acquisition Speed | <3 s per spectrum |
| Data Sampling Interval | Adjustable down to 0.25 cm⁻¹ (FT-based spectral reconstruction) |
| Sample Mode | Ambient or Controlled Environment (N₂-purged optional) |
| Compatible Chemometrics Software | Anasys IR-Spectra™ (with NIST-compatible spectral libraries, ASTM E1421-22 compliant preprocessing) |
| Brand | ASD |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FieldSpec HandHeld 2 |
| Instrument Type | Portable |
| Application Domain | Academic & Research (Universities, Earth Observation Labs, Environmental Monitoring) |
| Operating Principle | Fixed Grating with Linear CCD Array Detector (Non-scanning) |
| Wavelength Range | 325–1075 nm |
| Spectral Sampling Interval | 1.5 nm |
| Scan Speed | 10 spectra/sec |
| Measurement Mode | Reflectance (with optional irradiance calibration) |
| Calibration Software | RS3™ |
| Drift Compensation | DriftLock™ Baseline Stabilization Technology |
| Detector Type | Back-thinned Si CCD |
| FOV | 25° (Full Angle) |
| NEdL | 5×10⁻⁹ W/cm²/nm/sr @ 700 nm |
| Spectral Resolution | <3.0 nm FWHM @ 700 nm |
| Wavelength Accuracy | ±1 nm |
| Integration Time Range | 8.5 ms to 10 s (programmable) |
| Onboard Storage | Up to 2000 spectra |
| Display | 2.7-inch tilt-adjustable color LCD (6.8 cm diagonal) |
| Power Supply | 4× AA batteries (rechargeable NiMH or alkaline) or 5 V / 1.5 A AC/DC adapter |
| Battery Life | Up to 5 h (Li-ion), 2.5 h (NiMH), ~1.5 h (alkaline) |
| Dimensions (H×W×D) | 90 × 140 × 215 mm |
| Weight | 1.2 kg (incl. batteries) |
| Operating Temperature | 0–40 °C |
| Targeting Aid | Integrated Class 2 IR laser pointer (650 nm, visible alignment optional) |
| Connectivity | Mini-B USB, mini-TRS remote trigger port, dual Type-A USB expansion ports |
| Software Suite | RS3™ real-time acquisition & configuration, ViewSpecPro™ spectral analysis & chemometric modeling, HH2 Sync Interface for external GNSS/IMU synchronization |
| Brand | ASD |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Halo |
| Instrument Type | Portable |
| Application Field | General (Universities, Research Institutes) |
| Operating Principle | Grating-Based Array Detector (Non-Scanning) |
| Wavelength Range | 350–2500 nm |
| Scan Speed | 10 spectra/sec |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | ASD Halo Manager |
| Spectral Resolution | 3 nm @ 700 nm, 9.8 nm @ 1400 nm, 8.1 nm @ 2100 nm |
| Dimensions (L×W×H) | 775 × 250 × 750 mm |
| Weight (with battery) | 2.5 kg (5.5 lbs) |
| Weight (without battery) | 2.0 kg (4.3 lbs) |
| Supported Languages | English, Spanish, Chinese |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR256-1.7-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.53 ms/scan (USB 3.0) |
| Integration Time | 10 µs – 500 ms |
| Detector | 256-pixel InGaAs linear array (50 µm × 500 µm) |
| Optical Platform | Symmetrical Czerny-Turner, 50 mm focal length |
| Resolution (FWHM) | 2–50 nm (configurable via slit and grating) |
| Stray Light | <1% |
| Dynamic Range | 6000:1 (HS mode), 9000:1 (LN mode) |
| SNR | 1900:1 (HS), 5000:1 (LN) |
| Sensitivity | 8.2 × 10⁶ counts/µW·ms (HS, 1000–1750 nm) |
| ADC | 16-bit, 500 kHz |
| Interfaces | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 digital I/O |
| Power | USB-powered (600 mA) or external 12 VDC (320 mA) |
| Dimensions & Weight | 185 × 100 × 184 mm, 2.7 kg |
| Software | AvaSoft v8+ with chemometrics support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | NIR256-1.7-HSC-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.13 ms/scan |
| Data Sampling Interval | 0.4 ms/scan |
| Measurement Mode | Transmission/Reflection |
| Optical Design | Symmetrical Czerny-Turner, 100 mm focal length, 1-stage TE-cooled |
| Detector | TE-cooled InGaAs linear array (256 × 50 µm × 500 µm) |
| Interface | USB 3.0 (5 Gbps) and Gigabit Ethernet (1 Gbps) |
| AD Converter | 16-bit, 1.2 MHz |
| Integration Time (HS mode) | 20 µs – 500 ms |
| Integration Time (LN mode) | 20 µs – 20 s |
| Dynamic Range (HS/LN) | 4900:1 / 7600:1 |
| SNR (HS/LN) | 1900:1 / 5000:1 |
| Gain Modes | High Sensitivity (HS) and Low Noise (LN) |
| Grating Options | Four selectable, exchangeable gratings |
| Slit Options | Interchangeable slits (25–500 µm) |
| Digital I/O | HD-26 connector with 13 bidirectional digital I/O lines, 2 analog inputs/outputs, trigger/sync/gate/laser control |
| Operating Temperature | 0–40 °C |
| Cooling | ΔT = 24 °C below ambient |
| Dimensions & Weight | 185 × 160 × 184 mm, 3.6 kg |
| Software | AvaSoft suite with chemometrics support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR512-1.7-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.53 ms/scan |
| Data Sampling Interval | 0.53 ms/scan |
| Detector | 512-pixel InGaAs linear array (25 µm × 500 µm) |
| Optical Platform | Symmetrical Czerny-Turner, 50 mm focal length |
| Resolution (FWHM) | 2–50 nm (configurable via slit and grating) |
| Stray Light | <1% |
| AD Converter | 16-bit, 500 kHz |
| Interface | USB 3.0 (5 Gbps) and Gigabit Ethernet (1 Gbps) |
| Integration Time | 10 µs – 10 s |
| Dynamic Range | up to 9000:1 (LN mode) |
| SNR | up to 5000:1 (LN mode) |
| Trigger & I/O | HD-26 connector with 13 digital I/O lines, 2 analog in/out, TTL trigger, sync, strobe, laser control |
| Power | USB-powered (600 mA) or external 12 VDC (320 mA) |
| Dimensions & Weight | 185 × 100 × 184 mm, 2.7 kg |
| Software | AvaSoft suite with chemometrics support |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready (audit trail & user access control enabled) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Online Process Spectrometer |
| Model | BEAM |
| Design | Single-Channel FT-NIR |
| Sample Interface | In-line / At-line (pipeline, hopper, conveyor-mountable) |
| Optical Principle | Interferometric Fourier Transform Spectroscopy |
| Spectral Range | Typically 10,000–4,000 cm⁻¹ (1,000–2,500 nm) |
| Resolution | ≤4 cm⁻¹ (user-selectable) |
| Detector | Thermoelectrically Cooled InGaAs |
| Measurement Mode | Real-time, Continuous, Non-destructive |
| Compliance | Designed for GMP/GLP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MATRIX-F II |
| Instrument Type | Online FT-NIR Spectrometer |
| Measurement Principle | Fourier Transform (FT) Interferometry |
| Sampling Modes | Diffuse Reflectance, Transflectance, Liquid Transmission (with variable-pathlength fiber-optic probes) |
| Chemometrics Software | OPUS |
| Compliance | Designed for industrial process environments per IEC 61508 SIL2-ready architecture |
| Connectivity | Ethernet with support for OPC UA, Modbus TCP, and Profibus DP |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MOVE-T |
| Instrument Type | Laboratory |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Design | Benchtop, Flow-Through Configuration |
| Sample Form | Liquid dairy matrices only |
| Compliance Context | Designed for routine QC in dairy processing per ISO 9622:2013, IDF 141:2000, and AOAC Official Method 972.16 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MPA III |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared Spectroscopy |
| Wavelength Range | 12500–3600 cm⁻¹ |
| Scan Speed | 8 scans/sec at 8 cm⁻¹ resolution |
| Data Sampling Interval | 2 cm⁻¹ |
| Sampling Modes | Diffuse Reflectance, Transmission, Diffuse Transmission, Fiber-Optic Probe |
| Chemometrics Software | OPUS |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TANGO |
| Instrument Type | Laboratory |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 11,500–4,000 cm⁻¹ |
| Scan Speed | 8 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | OPUS |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1330 |
| Instrument Type | Portable |
| Detection Principle | Grating-scanning NIR spectroscopy with InGaAs detector |
| Measurement Time | ≤3 s per sample |
| Sample Forms | Granular, flake, and powdered materials |
| Connectivity | Wi-Fi, USB, Bluetooth (optional) |
| Power Supply | AC adapter or optional rechargeable Li-ion battery |
| Compliance | Supports ASTM E1655, ISO 12099, and GB/T 37878–2019 for NIR calibration transfer and performance validation |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 1340 |
| Instrument Type | Online NIR Spectrometer |
| Optical Design | Grating Scanning |
| Application Domain | Feed Production, Grain & Oil Processing, Brewing Industry |
| Measurement Principle | Diffuse Reflectance / Transmission NIR Spectroscopy |
| Sampling Interface | Customizable Process Probe |
| Connectivity | Ethernet, Fiber Optic, 4–20 mA Analog Output |
| Enclosure Rating | IP65 |
| Data Acquisition Rate | 5 Hz |
| Alarm Logic | Dual-level (Primary/Secondary) Thresholding |
| Software Integration | C# DLL for Custom SCADA/MES Integration |
| Built-in Reference Standard | Yes |
| Self-Diagnostic & Auto-Calibration | Yes |
| Compliance Context | Designed for GLP-aligned process analytical technology (PAT) deployment |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1350 |
| Instrument Type | Portable |
| Wavelength Range | 1000–1800 nm |
| Weight | 6 kg |
| Power Supply | DC 19 V or Built-in Rechargeable Lithium Battery |
| Display | Integrated Full-Color LCD with Chinese UI |
| Data Storage | Internal High-Capacity Flash Memory |
| Connectivity | USB 2.0 |
| Software | RIMP (Remote Instrument Management Platform) |
| Sample Interface | Interchangeable Probes for Solids, Powders, Pastes, Tablets, and Liquids |
| Diagnostic Function | Onboard Reference Material & Self-Diagnostic Routine |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 1360 |
| Instrument Type | Portable |
| Compliance | Meets GB/T and ASTM D7462/D8073 for fuel analysis |
| Operating Temperature Range | −5 °C to 50 °C |
| Temperature Control Range | 15–60 °C |
| Temperature Stability | ±0.2 °C |
| Measurement Time | ≤10 s per sample |
| Software Interface | Fully localized Chinese GUI with integrated modeling, calibration, and data management modules |
| Connectivity | Ethernet and Wi-Fi enabled for NIR network integration, remote diagnostics, model updates, and instrument health monitoring |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory-Based NIR Spectrometer |
| Model | EXPEC 1360A |
| Application Scope | Fuel Quality Analysis (Gasoline, Diesel, Biofuels), Onboard & At-Line Deployment |
| Optional Accessories | U-Tube Oscillating Density Meter (±0.0005 g/cm³), Rechargeable Battery Pack (8 h runtime) |
| Compliance Framework | Designed for ASTM D2887, D5292, D7467, ISO 20846, and GB/T 28768-2012 alignment |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EXPEC 1370 |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Detection Principle | Diffuse Reflectance NIR Spectroscopy |
| Typical Measurement Time | ≤10 s per sample |
| Detector | InGaAs Array |
| Optical System | Fixed Grating Monochromator |
| Wavelength Range | 900–1700 nm (standard configuration) |
| Compliance | Designed for GLP-compliant laboratory environments |
| Software | EXPEC NIR Analysis Suite with User Role Management (Admin/Operator/Reviewer) |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1380 |
| Pricing | Upon Request |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Detector | TEC-Cooled InGaAs |
| Optical System | Holographic Digital Grating |
| Sample Interface | Rotating Sample Carousel (Ø180 mm standard) |
| Measurement Principle | Diffuse Reflectance NIR Spectroscopy (900–1700 nm) |
| Data Acquisition Time | ≤10 s per sample |
| Built-in Computing | Integrated Industrial PC |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail capability |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | FoodScan 2 |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Design | Grating Scanning System |
| Wavelength Range | 400–1100 nm |
| Sample Throughput | 15–25 seconds per sample |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission and Reflectance |
| Chemometric Software Engine | Artificial Neural Network (ANN) Calibration |
| Regulatory Certification | AOAC Official Method of Analysis™ 983.18 |
| Application Scope | Raw and processed meat, poultry, and aquatic products (porcine, bovine, avian, etc.) |
| Key Analytes | Fat, Protein, Moisture, Collagen, Salt (Cl⁻ basis), Lean Meat Content |
| Optional Extensions | Saturated Fatty Acids, Ash, Sodium-based Salt, Water Activity, Color Parameters |