Near Infrared Spectrometer
Filter
Showing 61–90 of 158 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 1000–2500 nm |
| Scan Speed | 0.2 s per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SupNIR-1000 |
| Instrument Type | Portable |
| Operating Principle | Grating Scanning |
| Wavelength Range | 600–1100 nm & 1000–1800 nm |
| Analysis Time | <30 s |
| Wavelength Repeatability | ±0.05 nm |
| Sampling Modes | Diffuse Reflectance & Transmission |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | SupNIR-1200 |
| Instrument Type | Portable |
| Operating Principle | Grating Scanning |
| Wavelength Range | 1000–1800 nm |
| Scan Speed | <1 second per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Compliance | CE, RoHS (as per manufacturer documentation) |
| Power Supply | Integrated rechargeable lithium-ion battery |
| Connectivity | Bluetooth 4.2 + Android mobile application |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | SupNIR-1500 |
| Instrument Type | Portable |
| Optical Principle | Holographic Grating Scanning |
| Wavelength Range | 1000–1800 nm |
| Scan Speed | >1 spectrum/sec |
| Spectral Resolution | 1 nm sampling interval |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Detector | TE-Cooled InGaAs |
| Chemometrics Software | RIMP |
| Power Supply | Integrated Rechargeable Battery |
| Display | Built-in LCD |
| Data Storage | Onboard Memory |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SupNIR-1520TM |
| Instrument Type | Portable |
| Optical Principle | Holographic Gold-Coated Concave Grating Scanning |
| Detection Mode | Diffuse Reflectance |
| Software | RIMP Chemometrics Platform |
| Compliance | Designed for ISO 17025-aligned textile testing workflows |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Design | Holographic Scanning Grating with TEC-Cooled InGaAs Detector |
| Wavelength Range | 1000–1800 nm |
| Spectral Resolution | ≤ 8 nm (FWHM) |
| Wavelength Accuracy | ±0.2 nm |
| Data Sampling Interval | 1 nm |
| Scan Speed | Full-spectrum acquisition in < 60 s |
| Measurement Mode | Transmission |
| Chemometrics Software | RIMP v4.x (with PLS, PCR, SVM, and model validation modules) |
| Temperature Control | Integrated Peltier-based sample compartment (±0.1 °C stability) |
| Compliance | Meets ISO 12099:2017 for NIR instrument performance verification |
| Connectivity | Ethernet (RJ45), USB 2.0, optional Wi-Fi module |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 1000–2500 nm |
| Scan Speed | 0.2 s per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Principle | Holographic Grating Scanning |
| Wavelength Range | 1000–2500 nm |
| Spectral Acquisition Speed | 0.2 s per spectrum |
| Spectral Resolution | 1 nm data sampling interval |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Detector | Thermoelectrically Cooled (TEC) InGaAs Array |
| Sample Handling | Motorized Rotating Sample Tray |
| Built-in Reference Standards | Yes |
| Network Connectivity | Ethernet & USB |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | SupNIR-3000 |
| Instrument Type | Laboratory |
| Operating Principle | Grating Scanning |
| Wavelength Range | 1000–1800 nm |
| Scan Speed | >1 scan/s |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Design | Holographic Digital Grating + TEC-Cooled InGaAs Detector |
| Wavelength Range | 1000–1800 nm (expandable to 1000–2500 nm) |
| Scanning Mechanism | Grating-Based Wavelength Scanning |
| Software Platform | RIMP Chemometrics Suite (Chinese UI) |
| Connectivity | Ethernet, USB, Remote Management via Web-Based Instrument Control Platform |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail (via RIMP logging) |
| Brand | GreenSpectrum NIR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Design | Grating Scanning System |
| Wavelength Range | 700–2500 nm |
| Sampling Mode | Integrating Sphere Diffuse Reflectance Unit |
| Data Output Modes | Absorbance (A), Reflectance (R), Spectral Radiant Energy (E) |
| Calibration Traceability | NIST-traceable standard materials with uniform wavelength calibration points across full spectral range |
| Model Transfer Capability | Verified inter-instrument model portability under ASTM E1655 and ISO 12099 protocols |
| Software Compliance | SmartScan (local control), SmartNet (networked LIMS/ERP integration) supporting audit trail, user access control, and 21 CFR Part 11–ready data integrity features |
| Regulatory Alignment | Designed for GLP/GMP-aligned workflows |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Type | Online & Portable NIR Spectrometer |
| Model | TruProcess |
| Measurement Principle | Diffuse Reflectance NIR Spectroscopy (900–2500 nm) |
| Optical Architecture | MEMS-based Scanning Grating |
| Scan Speed | ≤5 µs per spectrum |
| Sampling Interface | Non-contact, Programmable Triggered Acquisition |
| Process Integration | DIN-rail mountable, 4–20 mA / Modbus TCP / OPC UA ready |
| Compliance | Designed for GMP/GLP environments |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N110 |
| Instrument Type | Portable NIR Spectrometer |
| Principle | MEMS-based Micro-Grating Monochromator with Array Detector |
| Wavelength Range | 640–1050 nm (Reflectance), 340–750 nm (Transmittance) |
| Optical Resolution | ≤20 nm (Reflectance), ≤14 nm (Transmittance) |
| Wavelength Repeatability | ±0.5 nm |
| Noise Level | ≤60 µAU |
| Signal-to-Noise Ratio | ≥7500 |
| Operating Temperature | 5–40 °C |
| Relative Humidity | <85% RH (recommended <75% RH) |
| Dimensions (L×W×H) | 179 × 126.5 × 52.6 mm |
| Weight | 215 g |
| Power Supply | DC 5 V / 1000 mA |
| Tungsten Lamp Current | 400 mA × 2 |
| Sampling Modes | Reflectance Ratio, Transmittance |
| Data Acquisition Interval | Configurable via Hanir Software |
| Scan Speed | Up to 10 spectra/sec (typical, dependent on integration time) |
| Software Platform | Android-based Hanir v3.x with GLP-compliant audit trail logging |
| Chemometrics Engine | Integrated MEMS-optimized PLS and PCA algorithms |
| Compliance | Supports ASTM E1655, ISO 12099, and USP <857> spectral data handling conventions |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N500 |
| Instrument Type | Portable |
| Principle | Micro-Electro-Mechanical Systems (MEMS)-based Fabry–Pérot Interferometer (FPI) |
| Wavelength Range | 1750–2150 nm (extendable to 2450 nm) |
| Detector | InGaAs |
| Wavelength Resolution (FWHM) | ≤20 nm (≤1% of operating wavelength) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio (SNR) | ≥3000 |
| Sample Measurement Time | <30 s |
| Light Source Lifetime | 5000 h |
| Measurement Mode | Diffuse Reflectance |
| Dimensions (L×W×H) | 395 × 280 × 215 mm |
| Weight | 5.5 kg |
| Included Computing Platform | Microsoft Surface tablet |
| Software | MEMS Chemometrics Suite |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N500 |
| Instrument Type | Portable |
| Measurement Principle | MEMS-based Micro-FPI (Fabry–Pérot Interferometer) |
| Wavelength Range | 1750–2150 nm |
| Sampling Mode | Diffuse Reflectance |
| Detector Type | InGaAs |
| Spectral Resolution (FWHM) | ≤20 nm (≤1% of center wavelength) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio (SNR) | ≥3000 |
| Measurement Time per Sample | <30 s |
| Light Source Lifetime | 5000 h |
| Dimensions (L×W×H) | 395 × 280 × 215 mm |
| Weight | 5.5 kg |
| Integrated Computing Platform | Microsoft Surface Tablet |
| Software Suite | MEMS Chemometrics Platform (Model Management, Quantitative Analysis, Audit Trail, User Permissions) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N550 |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | MEMS Micro-Electro-Mechanical Systems Spectral Modulation |
| Wavelength Range | 900–1700 nm |
| Detector | Thermoelectrically Cooled InGaAs Array (256 pixels) |
| Slit Width | 50 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Signal-to-Noise Ratio | ≥3000 |
| Measurement Time per Sample | <30 s |
| Sampling Mode | Diffuse Reflectance |
| Sample Holders | 10 cm wide-mouth cup & 3 cm powder cup |
| Dimensions (L×W×H) | 450 × 280 × 228 mm |
| Weight | 15 kg |
| Compliance | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready software architecture |
| Chemometrics Software | MEMS Quantitative Analysis Suite |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N70 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Interferometry |
| Wavenumber Range | 3750–12500 cm⁻¹ |
| Scan Speed | <1 s (at 8 cm⁻¹ resolution) |
| Data Sampling Intervals | 2, 4, 8, or 16 cm⁻¹ |
| Measurement Modes | Integrating Sphere Diffuse Reflectance / Transflectance |
| Chemometrics Software | PLSQ — Partial Least Squares Spectral Modeling System |
| Detector | TEC-cooled InGaAs (2-stage thermoelectric cooling) |
| Resolution | <2 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Accuracy | <0.1 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Reproducibility | <0.04 cm⁻¹ @ 7306.74 cm⁻¹ |
| Inter-instrument Wavenumber Reproducibility | <0.05 cm⁻¹ @ 7306.74 cm⁻¹ |
| Absorbance Precision | ±0.1% T |
| Sample Measurement Time | <30 s |
| Dimensions | 445 × 237 × 320 mm |
| Weight | 20 kg |
| Power Consumption | 60 W |
| Brand | Hiperscan |
|---|---|
| Origin | Germany |
| Model | Apo-Ident |
| Wavelength Range | 1000–1900 nm |
| Wavelength Resolution | 10 nm |
| Wavelength Stability | ±1 nm |
| Measurement Time | <15 s |
| Operating Temperature | 15–35 °C |
| Dimensions | 203 × 279 × 219 mm |
| Weight | 5.2 kg |
| Power Supply | 230 V~, 50/60 Hz, 60 W |
| Interface | USB Type-B |
| Software | QuickStep Apo-Ident |
| OS Compatibility | Windows Vista/7/8/10 (excluding Starter editions), Linux, macOS |
| Minimum System Requirements | 1 GB RAM, Pentium 1.6 GHz CPU, 0.5 GB disk space |
| Brand | HiperScan |
|---|---|
| Origin | Germany |
| Model | Finder SD |
| Spectral Range | 1000–1900 nm |
| Spectral Resolution | 10 nm |
| Stray Light | ≤0.20% |
| Measurement Time | <5 s (average of ≥500 scans), configurable from 1–15 s |
| Detector | Single-element uncooled InGaAs |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Photometric Reproducibility | ±0.1% |
| SNR | >2000:1 (≥2000 scans), >1000:1 (≥500 scans) |
| Photometric Linearity (max/RMS) | ≤1% / <1% |
| Light Source | Tungsten-halogen lamp |
| Sampling Interface | Diffuse reflectance probe (23 mm aperture) |
| Thermal Stability | Yes |
| Dimensions (W×D×H) | 225 × 235 × 385 mm |
| Weight | 9 kg |
| Interface | USB Type-B (with optional auxiliary I/O for motor control or sensor input) |
| Operating Temperature | 15–35 °C (Type 55) or 5–30 °C (Type 50) |
| Storage Temperature | −20 to +60 °C (non-condensing) |
| IP Rating | IP65 |
| Power Supply | 100–240 VAC ±10%, 50–60 Hz |
| Power Consumption | 78 W (warm-up), 36 W (operation), 5 W (standby) |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop Laboratory Spectrometer |
| Optical Principle | Fixed Grating with Linear InGaAs Array Detector (Non-scanning) |
| Wavelength Range | 1000–1700 nm |
| Measurement Modes | Transmission, Reflection, Absorbance |
| Chemometrics Software | FLA Suite |
| Detector | InGaAs (256-pixel linear array) |
| Pixel Resolution | 256 pixels |
| Slit Width | 200 µm (standard, optional) |
| Optical Resolution (FWHM) | ≤3.2 nm |
| Stray Light | <0.1% |
| SNR | 1200:1 (full signal, 1 s integration) |
| Linearity | >99.8% |
| Dynamic Range | 900,000 (typical, 16-bit digitization) |
| A/D Converter | 16-bit high-speed |
| FIFO Buffer | 4 KB |
| Interface | USB 2.0 |
| Dimensions | 182 × 110 × 50 mm |
| Weight | 1500 g |
| Power Supply | Bus-powered via USB 2.0 (no external power required) |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory-grade |
| Model | FLA6800 |
| Spectral Range | 1000–2500 nm |
| Optical Resolution | ≤3.20 nm (FWHM) |
| Stray Light | <0.1% |
| Detector | InGaAs linear array (512 pixels) |
| Slit Width | 200 µm (standard, optional) |
| SNR | 1200:1 |
| Linearity | >99.8% |
| Dynamic Range | 900,000 |
| Data Acquisition Interval | 12 ms + integration time |
| Sampling Mode | Reflectance / Transmittance |
| A/D Converter | 16-bit |
| FIFO Depth | 4K |
| Interface | USB 2.0 |
| Dimensions | 182 × 110 × 50 mm |
| Weight | 1500 g |
| Brand | KPM PSC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QuikCheck |
| Application | Laboratory & At-Line Analysis |
| Instrument Principle | Filter-Based NIR |
| Wavelength Channels | 1400 nm, 1820 nm, 1940 nm, 2200 nm |
| Scan Speed | Real-Time |
| Data Sampling Interval | User-Configurable |
| Sample Presentation | Diffuse Reflectance |
| Chemometrics Software | Onboard Embedded Suite |
| Brand | KPM Sensortech |
|---|---|
| Origin | USA |
| Model | NIR-6000 |
| Instrument Type | Online Near-Infrared Spectrometer |
| Principle | Filter-Based NIR Reflectance |
| Wavelength Range | 550–2500 nm |
| Measurement Interval | User-Configurable (as low as 4 ms) |
| Sampling Mode | Diffuse Reflectance |
| Scan Speed | Real-Time |
| Chemometrics Software | Embedded KPM NIR Analysis Suite |
| Operating Temperature | −20°C to +85°C (with optional thermal management) |
| Ingress Protection | IP65 |
| Calibration | Pre-Loaded Application-Specific Models |
| Brand | KPM Unity |
|---|---|
| Origin | USA |
| Model | SpectraStar XT Series |
| Wavelength Range | 680–2600 nm |
| Scan Speed | 10–60 s (20 scans) |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Detector | Cooled Dual InGaAs |
| Calibration Standard | NIST-traceable |
| Software | uScan & UCAL |
| Power Consumption | <5 W |
| Operating Temperature | 1–40 °C |
| Compliance | ISO 12099, LIMS-compatible, IP52-rated enclosure |
| Sample Mass Range | 1–300 g |
| Optical System | Holographic Scanning Grating, Sealed All-Reflective Path with Fused Silica Window |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Model | S430 |
| Optical Design | Grating Scanning Monochromator |
| Wavelength Range | 900–2500 nm |
| Wavelength Accuracy | ≤0.2 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Spectral Bandwidth | 8 nm |
| Stray Light | ≤0.1% |
| Absorbance Noise | ≤0.0005 Abs |
| Measurement Mode | Transmission (Cuvette-Based) |
| Scan Speed | 1 spectrum per minute |
| Data Sampling Interval | 5 s |
| Data Interface | USB 2.0 |
| Dimensions | 360 × 460 × 240 mm |
| Weight | 12 kg |
| Chemometrics Software | CAUNIRS (developed in collaboration with China Agricultural University) |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | S450 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Academic & Research Laboratories (Universities, Public Research Institutes) |
| Operating Principle | Grating Scanning Monochromator |
| Wavelength Range | 900–2500 nm |
| Scan Speed | Low / Medium / High Adjustable |
| Spectral Sampling Interval | 0.1–5 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | CAUNIR |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Model | InfraLUM FT-12 |
| Wavelength Range | 760–1150 nm |
| Spectral Resolution | 8 / 16 / 32 / 64 cm⁻¹ |
| Sampling Mode | Diffuse Reflectance / Transmission |
| Data Acquisition Interval | 1 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Sample Volume | 50 mL |
| Analysis Time | ≤90 s |
| Dimensions | 530 × 450 × 380 mm |
| Weight | 32 kg |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 110 W |
| Chemometrics Software | RIM (with PARCLE integration) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | InfraLUM FT-12 Industrial |
| Instrument Type | Laboratory |
| Principle | Fourier Transform (FT) NIR |
| Wavelength Range | 760–1150 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Parcel |
| Sample Compatibility | Liquid, semi-solid, and homogeneous solid samples in transmission cells |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TerraSpec HALO |
| Instrument Type | Portable |
| Operating Principle | Grating-based Scanning NIR Spectrometer |
| Wavelength Range | 350–2500 nm |
| Scan Rate | 100 spectra per second |
| Spectral Sampling Interval | 1 nm |
| Measurement Modes | Diffuse Reflectance, Specular Reflectance, Transmission |
| Chemometrics Software | Indico Pro |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Ir100-AC |
| Type | Online NIR Analyzer |
| Wavelength Range | 4-channel NIR |
| Scan Speed | 30 ms |
| Moisture Range | 0.1–70% w/w |
| Resolution | 0.01% |
| Accuracy | ±0.2% (matrix-dependent) |
| Housing Material | SS316L |
| IP Rating | IP65 |
| Operating Temperature | −10 to 50 °C |
| Humidity Range | 10–90% RH |
| Power Supply | DC 24 V, 2 A |
| Output Interfaces | TCP/IP, RS485/RS232, Digital Alarm Outputs (2 channels) |
| Probe Cable Length | Standard 5 m (extendable to 100 m) |
| Installation Distance | 250 ± 100 mm (non-contact transmission mode) |
| Weight | ≈9.8 kg |
| Dimensions | 130 × 360 × 160 mm |