| Brand | A&D (AND) |
|---|---|
| Origin | Japan |
| Model | 913BA1 / 914BA1 / 916BA1 |
| Operating Pressure Range | Up to 1.5 MPa |
| Input Signal | 0–10 V DC, 4–20 mA (configurable) |
| Pilot Pressure | 0.3 MPa |
| Supply Voltage | 24 V DC |
| Port Size | 1/4", 3/8", 1/2" |
| Fluid Compatibility | Liquids and gases non-corrosive to PTFE, Viton®, and brass |
| Input Impedance | ≥1 kΩ (voltage), ≤300 Ω (current) |
| Control Principle | Force-Balance + PI Algorithm |
| Hysteresis | ≤±0.2% FS |
| Linearity | ≤±1% FS |
| Response Time | <0.5 s (no-load) |
| Flow Consumption | ≤1.5 L/min (standard), ≤5 L/min (high-speed) |
| Weight | 2.2 kg / 3.4 kg / 6.8 kg |
| Valve Body Material | Brass |
| Diaphragm | PTFE |
| Seal Material | Viton® |
| Insulation Resistance | >1 MΩ |
| Mounting Orientation | Omnidirectional (zero-point drift ≤±1% FS dependent on orientation) |
| Orifice Diameter | 6 mm / 10 mm / 14 mm |
| Brand | ASAHI Precision (A&D) |
|---|---|
| Origin | Japan |
| Model | 944BA1 |
| Operating Pressure Range | Up to 1.0 MPa |
| Input Signal Options | 0–5 V, 0–10 V, or 4–20 mA (configurable via model suffix) |
| Pilot Pressure Requirement | ≤ 2/3 × max. operating pressure + α |
| Power Supply | 24 VDC |
| Port Size | 1/2″ |
| Fluid Compatibility | Liquids and gases non-corrosive to PTFE, Viton®, and brass |
| Diaphragm Material | PTFE |
| Seal Material | Viton® |
| Valve Body Material | Brass |
| Full-Scale Orifice Diameter | Φ16 mm |
| Zero Drift | ±1% FS (orientation-dependent) |
| Control Principle | Force-balance + PI feedback control |
| Hysteresis | ≤ ±0.2% FS |
| Linearity | ≤ ±1% FS |
| Response Time (no-load) | < 0.5 s |
| Air Consumption | ≤ 5 L/min (high-speed variant) |
| Weight | 2.3 kg |
| Insulation Resistance | > 1 MΩ |
| Input Impedance | ≥ 1 kΩ (voltage), ≤ 300 Ω (current) |
| Brand | ASAHI Precision |
|---|---|
| Origin | Japan |
| Model | S650SML / S650SMH |
| Pressure Range (S650SML) | 3.5–700 kPa |
| Pressure Range (S650SMH) | 12.5–2500 kPa |
| Set Resolution | 0.01 kPa (S650SML), 0.1 kPa (S650SMH) |
| Input Signal | 0–10 V DC |
| Supply Pressure | 800 ± 20 kPa (S650SML), 3000 ± 200 kPa (S650SMH) |
| Accuracy | ±0.14% FS |
| Zero & Span Temp. Coefficient | ±0.018% FS/°C |
| Display | 5-digit LED (kPa) |
| Control Principle | Force-Balanced Electrostatic Capacitance Sensing with PI Feedback |
| Supply Voltage | 24 V DC |
| Power Input | 100 V AC |
| Warm-up Time | ≤30 min |
| Operating Temperature | 5–40 °C |
| Dimensions (W×D×H) | 280 × 210 × 133 mm |
| Weight | ~3 kg |
| Inlet/Outlet Port | Rc 1/4 (S650SML), Rc 3/8 (S650SMH) |
| Orifice Diameter | Φ4 mm (S650SML), Φ11 mm (S650SMH) |
| Max. Consumption Flow | ≤1.5 L/min |
| Insulation Resistance | ≥1 MΩ |
| Brand | ASAHI |
|---|---|
| Origin | Japan |
| Model | S670S0.3 / S670S1 |
| Input Voltage | DC 24 V |
| Supply Pressure Range (Primary) | 60–150 kPa (S670S0.3) / 140–200 kPa (S670S1) |
| Output Pressure Range (Secondary, Adjustable) | 0.15–30.00 kPa (S670S0.3) / 0.5–100.00 kPa (S670S1) |
| Max. Supply Pressure | 150 kPa / 200 kPa |
| Pressure Sensor Type | Piezoresistive Silicon |
| Display | 4-digit LED (character height 10 mm) |
| Accuracy | ±1% FS |
| Response Time | ≤5 s |
| Operating Temperature | 0–40 °C |
| Interface | Φ6 push-to-connect fittings |
| Remote Analog Input Options | 0–5 V, 0–10 V, or 4–20 mA (model-suffix coded) |
| Output Flow Rate | 0–50 nL/min |
| Dimensions (W×H×D) | 96×96×138.5 mm |
| Weight | ~1.2 kg |
| Fluid Compatibility | Dry air only |
| Compliance | CE-marked for industrial use (IEC 61000-6-2/6-4), RoHS compliant |
| Brand | Asida |
|---|---|
| Model | XG5130A |
| Origin | Guangdong, China |
| Type | Online, Fully Automated X-ray Inspection System |
| Application | In-line Quality Control of Prismatic Pouch Lithium-ion Battery Cells |
| X-ray Source | Microfocus Tube (90 kV, 89 µA, 5 µm focal spot) |
| Imaging System | Dual-FOV Image Intensifier (2″/4″), 75–110 lp/cm resolution, X-CCD sensor (752 × 480 px) |
| Throughput | ≥30 ppm (≥30,000 units/day) |
| Measurement Repeatability | ±60 µm |
| False Positive Rate | ≤2% |
| Miss Detection Rate | 0.0% |
| Overall Yield Accuracy | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61000-6-4 and IEC 62471) |
| Brand | Atmos |
|---|---|
| Origin | Germany |
| Model | ATMOS |
| Measurement Principle | Gravimetric Calibration (ISO 8655-compliant) |
| Display | 7-inch Full-Color Touchscreen |
| Data Export | CSV, PDF, XML |
| Compliance | ISO 8655-6, ASTM E2791, GLP/GMP Audit Trail Ready |
| Connectivity | USB, Ethernet, Optional Wi-Fi |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions | 320 × 280 × 210 mm |
| Weight | 4.8 kg |
| Environmental Operating Range | 15–30 °C, 30–70% RH (non-condensing) |
| Brand | -- |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | AT650T / AT-Ozone Generator / AT650P / AT200M |
| Pricing | Upon Request |
| Brand | ATR |
|---|---|
| Origin | USA |
| Model | SLE 350 |
| Cooling Technology | Semiconductor-based Condensation |
| Minimum Operating Temperature | −20 °C |
| Form Factor | Benchtop / Fume Hood Compatible |
| Automation Level | Fully Automatic (One-Touch Operation) |
| Integrated Liquid-Level Detection | Yes |
| Compatibility | Universal Interface for Rotary Evaporators, Nitrogen Blow-Down Concentrators, and Other Solvent-Generating Instruments |
| Brand | Autobio |
|---|---|
| Model | AutoMimo1200 |
| Origin | Henan, China |
| Instrument Type | Benchtop Automated Sample Dispensing System |
| Throughput | Up to 800 assay positions per hour |
| Compliant with ISO 13485 | 2016 Quality Management System |
| Brand | AWA |
|---|---|
| Model | AWA5000 |
| Compliance | GB/T 3785.1–2023 / IEC 61672-1:2013 Class 1 |
| Standard Conformance | HJ 907–2017 |
| Dynamic Range | 123 dB |
| Display | 4.3-inch capacitive touchscreen |
| Internal Storage | 16 GB (expandable to 64 GB via microSD) |
| Communication | Wi-Fi, 4G LTE, Bluetooth |
| Positioning | Integrated GPS + network-assisted positioning |
| Audio Recording | High-fidelity time-stamped PCM recording |
| Frequency Analysis | Real-time 1/1 and 1/3-octave band analysis |
| Power Supply | Integrated outdoor-rated power management system |
| Optional Modules | Meteorological sensor suite, traffic flow counter, PTZ camera, LED display panel, acoustic source localization unit |
| Brand | Hangzhou Aihua |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AWA2000 |
| Pricing | Available Upon Request |
| Translation Stage | Consult Manufacturer |
| Brand | AZZOTA |
|---|---|
| Origin | USA |
| Model | BHY-205002 |
| Die Inner Diameter | 13 mm |
| Maximum Applied Load | 12 tons |
| Die Outer Diameter | 44.5 mm |
| Height | 71 mm |
| Mass | 0.67 kg |
| Material | High-grade stainless steel |
| Includes | Polished die sleeve (mirror-finish), vacuum base with sealing O-ring, plunger with O-ring, two polished anvils, and ejection tool |
| Brand | AZZOTA |
|---|---|
| Origin | USA |
| Model | BHY-81A |
| Working Pressure | 60 MPa (20 tons) |
| Clamp Travel Range | 0–12 cm |
| Platen Stroke | 4.5 cm |
| Platen Diameter | 10 cm |
| Pressure Gauge Range | 0–100 MPa |
| Dimensions (W×D×H) | 35 × 25 × 40 cm |
| Net Weight | 48 kg |
| Die Diameter | 13 mm (customizable) |
| Brand | AZZOTA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | BHY-81B Laboratory Hydraulic Pellet Press |
| Working Pressure | 60 MPa (20 ton force) |
| Clamp Travel Range | 0–10 cm |
| Platen Stroke | 4.5 cm |
| Platen Diameter | 10 cm |
| Pressure Gauge Range | 0–100 MPa |
| Dimensions (W×D×H) | 30 × 25 × 35 cm |
| Net Weight | 30 kg |
| Die Diameter | 13 mm (customizable) |
| Construction | Stainless steel platens |
| Operation | Manual |
| Display | Analog pressure gauge with real-time reading |
| Brand | Bar Control |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Industrial Pressure Switch |
| Model | PDL Series (Pneumatic) |
| Operating Principle | Mechanical Diaphragm-Actuated Snap-Action Switch |
| Contact Material | Pure Silver |
| Sealing Material | PTFE-Coated Piston |
| Repeatability | ±2.0% FS |
| Hysteresis Adjustment | Continuously Adjustable via External Knob |
| Electrical Rating | 250 VAC / 6 A (resistive), 30 VDC / 2 A (inductive) |
| IP Rating | IP65 |
| Process Connection | G¼" BSP Male |
| Media Compatibility | Compressed Air, Inert Gases, Vacuum (down to -0.95 bar) |
| Temperature Range | -20 °C to +80 °C |
| Certifications | CE, RoHS, UL Recognized (E487617) |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-4C |
| Output Voltage Range | 5–1600 V (2 V resolution) |
| Output Current Range | 2–100 mA (1 mA resolution) |
| Max Power Output | 160 W |
| Dimensions (W × D × H) | 315 × 290 × 128 mm |
| Weight | 5 kg |
| Brand | Beijing Liuyi / LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 130-0610 |
| Viewing Area | 280 mm × 180 mm |
| Power Consumption | 54 W |
| Brightness | Continuously Adjustable |
| Dimensions (L×W×H) | 360 mm × 250 mm × 46 mm |
| Surface Finish | White Orange-Peel Textured Coating |
| Stage Travel | 280 mm × 180 mm |
| Brand | Beijing Liuyi / LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WD-9420 |
| Pricing | Available Upon Request |
| Brand | BRAND® |
|---|---|
| Origin | Germany |
| Model | 26300 |
| Weight | 190 g |
| Battery Life | Up to 8 h |
| Pipette Range | 0.1–200 mL |
| Motor Speed Control | Continuous, Dual-Button Interface |
| Charging Indicator | LED Warning (2 h Pre-Empty) |
| Filtration | Integrated 0.2 µm Hydrophobic Membrane |
| Discharge Modes | Gravity Drain / Motor-Assisted Blow-Out |
| Compliance | CE, ISO 8549, EN 61000-6-3 |
| Brand | BRAND® |
|---|---|
| Origin | Germany |
| Model | 705200 |
| Operation Mode | Electric |
| Channel Count | Single-Channel |
| Volume Range | 1 µL – 50 mL |
| Display | Touchscreen Interface |
| Languages | English, German, French, Spanish, Chinese |
| Charging Option | Inductive Charging Stand (Optional) |
| Compliance | ISO 8655-compliant design principles |
| Intended Use | Precision continuous dispensing in GLP/GMP and research laboratories |
| Brand | Brilliance |
|---|---|
| Model | Bri-AP |
| Max Operating Pressure | 350–2000 psi (model-dependent) |
| Control Range | 0–1700 psi |
| Wetted Materials | 316L Stainless Steel / Hastelloy C-276 |
| Control Accuracy | ±1% FS |
| Repeatability | ≤0.5% FS |
| Response Time | ≤2 s |
| Temperature Range | –26 to +80 °C (standard) |
| Interface | 1/8″ Swagelok®-compatible compression fitting |
| Display | 4.3″ capacitive touchscreen HMI |
| Actuation Resolution | 0.06° step angle |
| Compliance | Designed for GLP/GMP-aligned process control environments |
| Brand | ESI |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | brineFAST |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP Viscometer Oil Standards |
| Viscosity Range | 57–21,250 cP (mPa·s) |
| Temperature Range | 25 °C (low-temp) and 60 °C (high-temp) |
| Accuracy | ±1% of nominal value |
| Packaging | 150 mL (4 fl oz) per vial |
| Shear Rate Suitability | >500 s⁻¹ |
| Base Fluids | Mineral oil and polybutene (hydrocarbon-based) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DIN |
| Pricing | Contact for Quote |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Generic Oil-Based Viscosity Standards |
| Pricing | Available Upon Request |
| Certified Accuracy | ±1% of Nominal Value (NIST-Traceable) |
| Volume Options | 500 mL (1 pt) or 150 mL (4 oz) |
| Base Fluids | Mineral Oil & Polybutene (Hydrocarbon-Based) |
| Recommended Shear Rate | >500 s⁻¹ |
| Suitable For | Cone/Plate Viscometers, Rotational Rheometers, Krebs Stormer Instruments |
| Calibration Compliance | ASTM D1200, ISO 2555, USP <911>, FDA 21 CFR Part 11 (when used with compliant software systems) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Type | NIST-Traceable Newtonian Calibration Fluid |
| Viscosity Range | 5–100,000 cP (mPa·s) at 25 °C |
| Accuracy | ±1% of stated value |
| Temperature Stability | Low thermal sensitivity (dη/dT ≈ 0.5–0.7 %/°C) |
| Packaging | 500 mL for ≥30,000 cP |
| Certificate | Included (NIST-traceable calibration report) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | High-Temperature Silicone Oil Viscosity Standards |
| Certified Accuracy | ±1% of stated viscosity value |
| Available Temperatures | 25°C (77°F), 93.3°C (200°F), 149.0°C (300°F) |
| Packaging | 500 mL (1 US pint) bottle with NIST-traceable calibration certificate |
| Compliance | ASTM D2196, ISO 2555, USP <911> |
| Recommended Accessories | Brookfield Thermosel temperature-controlled bath system |
| Newtonian Behavior | Confirmed across full operational temperature range |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Krebs Unit Viscosity Standard Oil |
| Nominal Viscosity Values | 61, 73, 87, 99, 106 KU at 25°C |
| Accuracy | ±1% of stated value |
| Packaging | 500 mL (1 pint) per bottle |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Spiral Adapter |
| Viscosity Range (LV Series) | up to 100,000 cP |
| Viscosity Range (RV Series) | up to 1.1 MPa·s |
| Viscosity Range (HA Series) | up to 2.2 MPa·s |
| Viscosity Range (HB Series) | up to 9.0 MPa·s |
| Repeatability | ±2% |
| Compatibility | All Brookfield standard viscometers and rheometers (DVNext, DV2T, DV3T, CAP2000+, etc.) |
| Shear Sensitivity Analysis | Optional software-supported calculation |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | SSA Small Sample Adapter |
| Sample Volume Range | 2.1–16.1 mL |
| Compatible Spindles | SC4-14, SC4-15, SC4-16, SC4-18, SC4-21, SC4-25Z, SC4-27(D), SC4-28, SC4-29, SC4-31, SC4-34 |
| Shear Rate Range | 0.22–1.32 s⁻¹ (spindle-dependent) |
| Compatible Instruments | DVNext, DV2T, DV3T, DV1, DV2, DV3, LV/ RV/ HA/ HB series digital viscometers and rheometers |
| Compliance | Designed for ASTM D2196, ISO 2555, USP <911>, and GLP-compliant viscosity testing workflows |