Other Common Laboratory Equipment
Filter
Showing 331–360 of 1883 results
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 7490005 |
| Flow Rate Range | 0.2 µL/hr to 500 mL/hr |
| Syringe Compatibility | 10 µL – 60 mL |
| Accuracy | ±0.5% |
| Repeatability | ±0.2% |
| Bidirectional Operation | Yes |
| Communication Interfaces | RS232, TTL, Analog Voltage/Current Output |
| Sterilizable Components | 316 Stainless Steel Syringe Body |
| Pulse Mode | Supported |
| Footswitch Compatible | Yes |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 75211-17 |
| Max Speed | 5000 rpm |
| Min Speed | 50 rpm |
| Speed Control Range | 100:1 |
| Max Flow Rate (with A-mount pump head) | 5850 mL/min |
| Min Flow Rate (with A-mount pump head) | 0.85 mL/min |
| Input Voltage | 230 VAC, 50/60 Hz |
| IP Rating | IP22 |
| Dimensions (W×L×H) | 7.2 × 9.1 × 5.3 in (18.3 × 23 × 13.4 cm) |
| Remote Control Interface | DB9 connector |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | RS-200D |
| Temperature Range | −30 °C to 150 °C |
| Stirring Speed | 350–1200 rpm |
| Vessel Capacity | 2–25 mL |
| Control Interface | Touchscreen with microprocessor-based automation |
| Gas Environment Compatibility | Vacuum and inert gas (N₂, Ar) via PTFE tubing |
| Optional Accessories | Reflux condensers, Clarity™ Solubility & Crystallization Monitoring System, Multi-channel IR probes |
| Brand | HISTO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CE310-LSP |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Dimensions (L×W×H) | 440 × 220 × 380 mm |
| Weight | 25 kg |
| Operating Temperature | −5 to 40 °C |
| Power Consumption | 120 W |
| Maximum Load Capacity | 150 slides |
| Collection Capacity | 100 slides per tray |
| Printing Speed | >15 slides/min |
| Laser Resolution | 0.01 mm |
| Character Size Support | 1 mm × 1 mm Chinese characters |
| Air Handling | Vacuum-based dual-stage adsorption (liquid + solid phase), integrated duct cleaning function |
| Brand | HISTO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CE320-LSP |
| Price | USD 22,500 (FOB Zhejiang) |
| Dimensions (L×W×H) | 440 × 220 × 380 mm |
| Weight | 25 kg |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Operating Temperature | −5 °C to 40 °C |
| Power Consumption | 120 W |
| Max. Loading Capacity | 150 slides |
| Max. Collection Capacity | 100 slides |
| Print Speed | >15 slides/min |
| Resolution | 0.01 mm |
| Minimum Printable Character Size | 1 mm × 1 mm (Chinese character) |
| Display | 8-inch capacitive touchscreen |
| Integrated Barcode Scanner | Yes |
| Air Handling | Vacuum-based dual-stage adsorption (liquid + solid phase), with automatic duct cleaning function |
| Slide Ejection | Front-facing, bi-lateral access |
| Cassette Design | Interchangeable collection trays (compatible with standard slide transport workflows) |
| Brand | HISTO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CE6100H-LCP |
| Price Range | USD 19,800–22,700 |
| Dimensions (L×W×H) | 440 × 290 × 350 mm |
| Weight | 25 kg |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Operating Temperature | −5 °C to 40 °C |
| Power Consumption | 120 W |
| Cassette Capacity (Load) | 100 pcs |
| Throughput | >25 cassettes/min |
| Minimum Feature Size | 0.01 mm |
| Character Size | 1 mm × 1 mm (Chinese glyphs) |
| Air Handling | Vacuum-based dual-stage adsorption (liquid + solid phase) |
| Brand | HISTO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Model | CE6330H-LCP |
| Dimensions (L×W×H) | 54 cm × 44 cm × 49 cm |
| Weight | 40 kg |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Operating Temperature | −5 °C to 40 °C |
| Power Consumption | 120 W |
| Maximum Loading Capacity | 600 cassettes |
| Collection Capacity | ≥330 marked cassettes |
| Throughput | >20 cassettes/min |
| Cassette Feed | 6 independent loading racks |
| Collection Tray Capacity | ≥33 cassettes per tray |
| Air Handling | Vacuum-based dual-stage (liquid + solid) adsorption with automated duct cleaning |
| Cassette Orientation During Collection | Lateral forward advancement (prevents stacking/overlapping) |
| Template Editing | In-situ GUI-based template editor — no software switching required |
| Consumables | None (laser marking, no ribbons or ink) |
| Brand | KJ GROUP (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Cu Foil (Graphene-Grade) |
| Thickness | 25 µm |
| Dimensions | 150 mm × 150 mm |
| Electrical Conductivity | 97% IACS @ 20 °C |
| Particle Size (Surface Roughness Ra) | 0.02 mm |
| Density | 8.94 g/cm³ |
| Vickers Hardness | 80 HV |
| Tensile Strength (Longitudinal) | 28 kgf/mm² |
| Elongation | 3–8% min |
| Resistivity | ≤0.017165 Ω·mm/m |
| Net Weight | 5 kg |
| Brand | Corning |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | LFR |
| Pricing | Upon Request |
| Translation Stage | Contact Manufacturer |
| Brand | Corning |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Nebula™ Teaching Platform System |
| Pricing | Available Upon Request |
| Brand | Corning |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Zaiput SEP-10 |
| Pricing | Available Upon Request |
| Brand | Huiyan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | General Distributor |
| Origin Category | Domestic |
| Model | BJ22, BJ26 |
| Pricing | Upon Request |
| Waveguide Standard | BJ22, BJ26 |
| Flange Standard | FDP22, FDP26 |
| Coupling Factor | C = 50 ± 2 dB |
| Directivity | D > 20 dB |
| Voltage Standing Wave Ratio (VSWR) | ≤ 1.1 |
| Brand | Covesion |
|---|---|
| Origin | United Kingdom |
| Product Type | Periodically Poled Lithium Niobate (MgO-doped) Waveguide Device |
| Model | WG-1540 / WG-1550 / WG-1560 |
| Configuration Options | Bare Chip, Fiber-Pigtailed (APC), Thermally Tunable Package with Integrated Heater |
| Wavelength Support | 1540 nm, 1550 nm, 1560 nm (SHG-ready) |
| Operating Principle | Quasi-Phase-Matched Second Harmonic Generation (QPM-SHG) in MgO:PPLN Ridge Waveguide |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-30020-SYS |
| Price | Upon Request |
| Funnel Diameter | 4 in (101.6 mm) |
| Capacity | 450 mL |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 38–430, 38–400, 53 mm, 63 mm, 70 mm, 83 mm, 100 mm, or custom |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes, particulate-retaining |
| Max HPLC Fittings | 6 |
| Compatible Vessel Sizes | 2 L to 20 L, including narrow-mouth PP, LDPE, and Justrite safety cans |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-30020C-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4" (101.6 mm) |
| Neck Length | 11" (279 mm) |
| Top Dimensions | 5" × 7" (127 mm × 178 mm) |
| Neck Thread | 38–430 |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compatible Container Sizes | 20 L rectangular solvent carboy |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-3009-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 38–430, 38–400, 53 mm, 63 mm, 70 mm, 83 mm, 100 mm, or custom |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes, particulate retention |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA 29 CFR 1910.1200 (HCS), ANSI Z9.5–2022 (Laboratory Ventilation), and EPA 40 CFR Part 262 waste containment guidelines |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-3009C-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 38–430, 38–400, 53 mm, 63 mm, 70 mm, 83 mm, 100 mm, or custom |
| Material | High-Density Polyethylene (HDPE) |
| Filter | Integrated particulate filter |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA 29 CFR 1910.1200 (HCS), NFPA 30, and EPA 40 CFR Part 262 for lab-scale hazardous waste containment |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-38 |
| Capacity | 450 mL |
| Funnel Top Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 38-430 |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Compatible Bottle Sizes | 2 L & 4 L LDPE/PP reagent bottles |
| Max HPLC Fitting Ports | 6 |
| Compliance | Meets OSHA, ANSI Z9.5, and EPA waste handling best practices |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-38 |
| Capacity | 450 mL |
| Funnel Top Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 38-430 |
| Material | High-Density Polyethylene (HDPE) |
| Solid Particle Filtration | Integrated Filter Screen |
| Max HPLC Fitting Ports | 6 |
| Compliance | Compatible with OSHA, NFPA 30, and EPA waste containment guidelines |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Laboratory Safety Equipment |
| Model | EF-4-38-400 |
| Capacity | 450 mL |
| Funnel Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 38-400 |
| Material | High-Density Polyethylene (HDPE) |
| Solid Particle Filtration | Integrated Filter Disc |
| Max HPLC Fitting Ports | 6 |
| Compliance | Meets OSHA, ANSI Z9.5, and EPA Waste Handling Guidelines |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EF-4-38-4004-SYS |
| Pricing | Upon Request |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EF-4-38-62-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 38-430 |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA, ANSI Z9.5, and EPA waste handling best practices |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EF-4-38-62-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4" (101.6 mm) |
| Neck Length | 11" (279 mm) |
| Top Dimensions | 5" × 7" (127 mm × 178 mm) |
| Neck Thread | 38-430 |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA, ANSI Z9.5, and EPA waste handling best practices |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EF-4-38-62-SYS |
| Funnel Diameter | 4 in (101.6 mm) |
| Capacity | 450 mL |
| Neck Length | 11 in (279 mm) |
| Neck Thread | 38-430 |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA, ANSI Z9.5, and EPA waste containment best practices |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EF-4-38-65-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4" (101.6 mm) |
| Neck Length | 11" (279 mm) |
| Top Dimensions | 5" × 7" (127 mm × 178 mm) |
| Neck Thread | 38-430 |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA 29 CFR 1910.1200 (HCS), NFPA 30, and EPA 40 CFR Part 262 requirements |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-38-82-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 38-430 |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA 29 CFR 1910.1200 (HCS), NFPA 30, and EPA 40 CFR Part 262 requirements |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-38-85-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4" (101.6 mm) |
| Neck Length | 11" (279 mm) |
| Top Dimensions | 5" × 7" (127 mm × 178 mm) |
| Neck Thread | 38-430 |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA, ANSI Z9.5, and EPA waste handling best practices |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Model | EF-4-38B-SYS |
| Funnel Diameter | 4" (101.6 mm) |
| Neck Length | 11" (279 mm) |
| Top Dimensions | 5" × 7" (127 mm × 178 mm) |
| Capacity | 450 mL |
| Material | High-Density Polyethylene (HDPE) |
| Neck Thread | 38-430 Standard |
| Solid Particle Filtration | Integrated Sintered Polyethylene Filter |
| Max HPLC Fitting Ports | 6 |
| Compliance | Meets OSHA, NFPA 30, and ANSI Z9.5 Laboratory Ventilation Standards |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-38GL-SYS |
| Pricing | Upon Request |
| Funnel Diameter | 4 in (101.6 mm) |
| Funnel Capacity | 450 mL |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 38-430 |
| Material | High-Density Polyethylene (HDPE) |
| Solid Particle Filtration | Integrated polypropylene filter disc |
| Max HPLC Fitting Ports | 6 |
| Compatible Bottles | 2 L and 4 L LDPE/PP narrow-mouth containers |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-38Y |
| Capacity | 450 mL |
| Funnel Top Diameter | 4 in (10.16 cm) |
| Neck Length | 11 in (27.9 cm) |
| Top Dimensions | 5 in × 7 in (12.7 cm × 17.8 cm) |
| Neck Thread | 38-430 |
| Material | High-Density Polyethylene (HDPE) |
| Solid Particle Filtration | Integrated Filter Disc |
| Max HPLC Fitting Ports | 6 |
| Color | Yellow Cap |