Other Common Laboratory Equipment
Filter
Showing 361–390 of 1883 results
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-53B-SYS |
| Price | Upon Request |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EF-4-63B-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 63 mm |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA, ANSI Z9.5, and EPA waste handling best practices |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Laboratory Safety Equipment |
| Model | EF-4-63BY-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 63 mm |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA, ANSI Z9.5, and NFPA 30 laboratory ventilation & flammable liquid handling guidelines |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EF-4-63C-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4" (101.6 mm) |
| Neck Length | 11" (279 mm) |
| Top Dimensions | 5" × 7" (127 mm × 178 mm) |
| Neck Thread | 63 mm |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA 29 CFR 1910.1200 & ANSI Z9.5 Ventilation Standards |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EF-4-63CY-SYS |
| Capacity | 450 mL |
| Funnel Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Neck Thread | 63 mm |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA, ANSI Z9.5, and EPA waste handling best practices |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Model | EF-4-83B-SYS |
| Funnel Diameter | 4 in (101.6 mm) |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Capacity | 450 mL |
| Neck Thread | 83 mm |
| Material | High-Density Polyethylene (HDPE) |
| Filter Included | Yes |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA, NFPA 30, and EPA waste handling guidelines |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-83C-SYS |
| Pricing | Available Upon Request |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Laboratory Safety Equipment |
| Model | EF-4-FS70-SYSB |
| Capacity | 450 mL |
| Funnel Diameter | 4" (101.6 mm) |
| Neck Length | 11" (279 mm) |
| Top Dimensions | 5" × 7" (127 mm × 178 mm) |
| Neck Thread | 38–430, 38–400, 53 mm, 63 mm, 70 mm, 83 mm, 100 mm, or Justrite-compatible |
| Material | High-Density Polyethylene (HDPE) |
| Filter | Integrated particulate filter |
| Max HPLC Fitting Ports | 6 |
| Compatibility | 5-gallon (18.9 L) poly drums, narrow-mouth PP/LDPE bottles, safety cans, and custom containers |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-FS70C-SYSN |
| Price | Upon Request |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EF-4-Justrite B2-SYS |
| Pricing | Available Upon Request |
| Funnel Diameter | 4" (101.6 mm) |
| Neck Length | 11" (279 mm) |
| Top Dimensions | 5" × 7" (127 mm × 178 mm) |
| Capacity | 450 mL |
| Material | High-Density Polyethylene (HDPE) |
| Neck Thread | 38–430 Standard |
| Filter Included | Yes, particle-retaining |
| Max HPLC Fittings | 6 |
| Compliance | OSHA 1910.1200, NFPA 30, ANSI Z9.5, UL 1317 |
| Brand | CP Lab Safety |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EF-4-Justrite-B5-SYS |
| Price | Upon Request |
| Funnel Diameter | 4 in (101.6 mm) |
| Capacity | 450 mL |
| Neck Length | 11 in (279 mm) |
| Top Dimensions | 5 in × 7 in (127 mm × 178 mm) |
| Material | High-Density Polyethylene (HDPE) |
| Thread Specification | 38–430, 38–400, 53 mm, 63 mm, 70 mm, 83 mm, 100 mm |
| Filter Included | Yes, particulate-retaining |
| Max HPLC Fittings | 6 |
| Compliance | Meets OSHA, NFPA 30, and ANSI Z9.5 laboratory ventilation standards |
| Brand | Cressington |
|---|---|
| Origin | United Kingdom |
| Model | 108Auto+108C |
| Vacuum System | Integrated dual-chamber configuration (sputter + carbon evaporation) |
| Power Supply | Fully automated DC sputtering with adjustable current (0–100 mA), high-stability carbon filament evaporation |
| Chamber Material | Stainless steel with quartz viewport |
| Base Pressure | ≤5 × 10⁻² mbar (standard turbomolecular pump option) |
| Sample Stage | Motorized, height-adjustable, tilt-capable (0–90°), cooled or ambient operation |
| Dimensions (W×D×H) | 420 × 460 × 380 mm |
| Weight | 32 kg |
| Brand | Cresta |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | SD-20 |
| Price | USD 170 (FOB Shanghai) |
| Brand | HENGYU |
|---|---|
| Origin | Tianjin, China |
| Model | HY-789-1 |
| Power Supply | AC 220 V, 50 Hz, 500 W |
| Operating Environment | 20 ± 2 °C, 65 ± 4 % RH |
| Dimensions (L×W×H) | 60 × 40 × 40 cm |
| Weight | 80 kg |
| Compliant Standards | ASTM D2097, GM 9226P / 9216P, Ford FLTM BN 102-02, MF-MH BN2-2, TSL5101G Section 3.14.1 B |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WRL |
| Pricing | Available Upon Request |
| Brand | Nanjing Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Classification | Domestic (PRC) |
| Model | Cupid-B |
| Price Range | USD 0.15 – 195 |
| Brand | CAVI (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Custom Catalyst Evaluation System |
| Pricing | Available Upon Technical Consultation |
| Brand | Huiyan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Series | BJ-26 / BJ-22 / BJ-9 |
| Pricing | Available Upon Request |
| Material Options | Aluminum, Copper, Stainless Steel |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Costom |
| Price Range | USD 270,000 – 405,000 (FOB UK) |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Capacity | Customizable 5L |
| Pricing | Upon Request |
| Brand | KJ GROUP (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | CBR-2000 Integrated R&D System for Cylindrical Li-ion Cells |
| Pricing | Available Upon Technical Consultation |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Pack of 12 SU Allegro Needles – 0.8 mm Luer |
| Sterilization | Gamma Irradiation (≤50 kGy) or Steam Autoclaving (130°C, 75 min) |
| Material | PEEK shaft with stainless steel reinforcement, polypropylene hub, silicone O-ring |
| Fluid Path | USP Class VI compliant |
| Cleanroom Manufacturing | ISO Class 8 |
| Quality System | ISO 9001 certified |
| Regulatory Compliance | USP <788>, <85>, <661.1>, <1031>, FDA 21 CFR Part 11–ready documentation support |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | EPS |
| Application | Dedicated Power Supply for Electrophoresis Systems |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Compliance | CE, UL 61010-1, IEC 61010-2-040 |
| Safety Features | Overload Protection, Short-Circuit Protection, Auto-Restart After Power Interruption |
| Power Range | EPS 301 (1–80 W) |
| Voltage Range | EPS 301 (5–300 V DC) |
| Current Range | EPS 301 (10–400 mA) |
| Time Programming | EPS 301 (00.01–23.59 h or OFF) |
| EPS 3501XL (00 | 01–500 h) |
| Resolution | Voltage (1 V), Current (EPS 301: 1 mA |
| EPS 3501XL | 1 µA to 1 mA depending on range), Time (1 min) |
| Accuracy | Voltage (±4% ±2 V for EPS 301 |
| Timer Accuracy | ±0.1% ±1 min (EPS 301) |
| ±0.1% ±1 min (≤99 | 59 h) / ±0.1% ±10 min (100–500 h) for EPS 3501XL |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RTP XL 100 L, Polypropylene Construction |
| Capacity Options | 100 L, 200 L, 500 L, 1000 L |
| Wheel Configuration | Full-rotation locking casters |
| Bag Integration | Compatible with ReadyCircuit single-use bag assemblies |
| Drain Plate | Removable, accommodates capsule filters up to 72.6 cm (30 in) |
| Ergonomic Features | Hinged access door (500/1000 L models), low-profile fill/drain ports, integrated volume scale indicators |
| Material Compliance | USP Class VI polypropylene, ISO 10993-compliant contact surfaces |
| Sterility Assurance | Designed for gamma-irradiated single-use bag integration under aseptic conditions |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xcellerex APS |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Xcellerex™ |
| Pricing | Available Upon Request |
| Brand | DC-Energies |
|---|---|
| Model | DC-4 |
| Origin | Hubei, China |
| Construction Material Options | Graphite, Aerospace-Grade Titanium, Pt-Coated Titanium, Nickel Plate |
| Active Area Customization | 1–100 cm² (e.g., 1, 4, 5, 16, 25, 50, 100 cm²) |
| Flow Field Configurations | Single-, 3-, or 10-channel layouts |
| Flow Field Patterns | Serpentine, Parallel, or Rectangular (customizable) |
| Heating Integration | Cartridge Heater or Flexible Heated Foil (optional) |
| Interface Compatibility | Gas Inlet/Outlet Ports, Thermocouple Terminals (e.g., K-type), Current Collector Busbars (gold-plated copper or titanium) |
| Key | Brand: DDS |
|---|---|
| Origin | South Africa |
| Model | 2370/SEM |
| Compliance | ASTM D240, D5865, D4809, D5468, E144, E711 |
| BS 4791 | 1985 |
| Sample Throughput | Up to 8 CV determinations per hour |
| Measurement Time | 2–4 min per test |
| Memory Capacity | 1000 test records with operator metadata and test conditions |
| Smart Bomb Count | 255 uniquely identified intelligent oxygen bomb vessels |
| Calibration Modes | Automatic correction for fuse wire, cotton, ignition energy |
| Integrated Calibration Sensors | Embedded in each bomb vessel |
| Mass Input Options | Manual keypad, analytical balance interface, or PC-based data import |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ALTR-5000 |
| Voltage | 220 V AC |
| Power Consumption | 1200 W |
| Net Weight | 145 kg |
| External Dimensions | 118 × 66 × 110 cm |
| Test Speed | 360 ± 40 mm/min |
| Temperature Range | –40 °C (adjustable in 1 °C increments) |
| Specimen Capacity | 10 or 20 specimens per cycle |
| Specimen Size | 150 × 25 mm |
| Timing Range | 0–99 min 59 sec (programmable) |
| Mandrel Diameters | Φ20 mm, Φ30 mm, Φ50 mm |
| Cooling System | Dual-compressor refrigeration unit |
| Control Interface | 7-inch capacitive touchscreen with embedded PLC logic |
| Compliance | GB/T 328.14–2007 (Method 14: Low-Temperature Flexibility of Bituminous Waterproofing Membranes) |
| [Brand | Deleite |
|---|---|
| Origin | Shanghai, China |
| Model | RTF-8500 |
| Voltage | 220 V AC, 50 Hz |
| Total Power | 3 kW |
| Air Flow Rate | 4000 mL/min |
| Turntable Speed | 15 rpm |
| Sample Capacity | 8 x asphalt sample bottles |
| Temperature Control Range | 163 °C ± 0.5 °C |
| Chamber Dimensions | 485 × 445 × 380 mm (W × D × H) |
| Construction | Dual-layer stainless steel chamber with forced-air circulation system |
| Integrated Miniature Air Compressor | Yes] |
