| Brand | CEA (China Education Goldsource) |
|---|---|
| Model | CEL-SPEC |
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (PRC) |
| Light Source | 500 W Osram Xe Lamp (Germany) |
| Spectrometer | 300 mm Focal Length, Dual-Output Imaging Spectrometer |
| Spectral Range | 200–1100 nm |
| QE/IPCE Calibration Standard | NIST-traceable UV-enhanced calibrated photodiode |
| Optical Configuration | Dual orthogonal beam paths (vertical SPS + horizontal PEC) |
| Positioning System | Motorized Precision Translation Stage (horizontal sample exchange) |
| Data Acquisition Mode | Synchronized lock-in detection (AC mode) |
| Chopping Frequency | 5–1000 Hz |
| Short-Circuit Current Repeatability | <0.3% (RSD) |
| Software Platform | Windows 7/8/10 compatible proprietary acquisition & analysis suite |
| Recommended Electrochemical Workstation | Admesy Admiral or Ivium Squidstat Plus (optional) |
| Brand | CEL (CNI) |
|---|---|
| Model | CEL-SPIP |
| Origin | Beijing, China |
| Manufacturer | Beijing CNI Co., Ltd. |
| Type | OEM Upgrade Module for SPS Systems |
| Light Source | 500 W Osram Xe Lamp |
| Spectrometer | 300 mm Focal Length, High-Resolution Imaging Spectrometer |
| Spectral Range | 200–1100 nm |
| Calibration Standard | NIST-traceable UV-enhanced reference detector |
| Measurement Modes | DC & AC (chopped, 5–1000 Hz) |
| Positioning | Motorized Horizontal Precision Translation Stage |
| Data Synchronization | Integrated hardware-triggered acquisition (light source, spectrometer, lock-in amplifier) |
| Repeatability | <0.3% (J<sub>sc</sub>) |
| Compliance | ASTM E1021, ISO 18746, IEC 60904-8 Ed.3 |
| Software | CEL-QEPro v3.x with GLP-compliant audit trail, 21 CFR Part 11 optional modules |
| Brand | CEAULIGHT |
|---|---|
| Model | CEL-TAS2000 |
| Origin | Beijing, China |
| Manufacturer Type | OEM Instrument Manufacturer |
| Product Category | Domestic Scientific Instrumentation |
| Pricing | Upon Request |
| Brand | CEAULIGHT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | CEL-TAS3000 |
| Pricing | Upon Request |
| Sensitivity | < 0.1 mOD |
| Time Resolution | ≤1.4 × laser pulse width |
| Delay Line Time Accuracy | 1 fs (2 ns time window) |
| Probe Spectral Range | 350–1100 nm |
| Time Window Options | 2 ns / 4 ns |
| Detector | 2048-pixel high-speed CMOS spectral array |
| Spectral Resolution | 2.5 nm (50 µm slit) |
| Acquisition Rate | 2.5 kHz |
| Pump Laser Compatibility | Integrated frequency-doubling optics |
| Sample Compatibility | Solid films, liquids, thin-film substrates |
| Upgradability | Microscopic pump-probe configuration via standardized optical interface |
| Brand | CME (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | CEL-WLAX500 |
| Pricing | Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | 112FR-NEPTUNE Plus |
| Vial/Tube Material | PFA or FEP |
| Vial Volume Options | 10 mL, 35 mL (customizable) |
| Part Number | NJ-ZH |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Distributor |
| Regional Origin | Domestic (China) |
| Model | CeTech GDS&GDL Series |
| Pricing | Upon Request |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Asia-Pacific |
| Model | CeTech GTI-Series Graphite Thermal Sheets |
| Pricing | Available Upon Request |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Distributor |
| Regional Category | Domestic (China Market) |
| Model | N-Series Carbon Paper |
| Pricing | Upon Request |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Asia-Pacific Sourced |
| Model | W-Series W0S1002 |
| Pricing | Available Upon Request |
| Sample Width | 24.4 mm |
| Effective Specimen Length | 45 mm |
| Grip Separation Rate | 6.35 mm/min |
| Air Permeability Test Condition | 300 cc/min at 0.1 in² orifice (CFY-030) |
| Through-Plane Electrical Resistivity | Measured via 4-probe method using circular 50-mm-diameter copper-plated electrodes under 200 psi compressive load |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CF121 |
| Pricing | Available Upon Request |
| Production Capacity | 25 L/h |
| Operating Pressure Range | 20–100 PSI |
| CO₂ Saturation Range | 5.0–10.0 g/L (adjustable in 0.5 g/L increments) |
| Cooling Temperature | 6 °C |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Dimensions | 520 × 580 × 950 mm |
| Net Weight | 90 kg |
| Integrated Refrigeration Unit | Yes |
| Number of Filling Heads | 5 (for LOOP variant) |
| CF121 | single-station semi-automated carbonation-filling unit |
| Bottle Compatibility | Up to 1.5 L PET/glass containers |
| Pre-purge & Pressurized Filling | Yes |
| CO₂ Purge Before Filling | Yes |
| Oxygen Exclusion During Filling | Yes |
| Startup Time (Cooling + Saturation) | <15 min |
| Compliance | CE, NSF/ANSI 169 (Beverage Equipment) |
| Brand | Zhongjiao Jinyuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CEQW-22 |
| Pricing | Upon Request |
| Cold Finger | CEQW-22, 60/40 standard taper, effective length 220 mm, fused quartz |
| Reactor Vessel | CNR-25 or CNR-50, borosilicate glass (PYREX® equivalent), flat-bottom or round-bottom configuration, 250 mL or 500 mL capacity |
| Cooling | Water-jacketed cold finger for lamp thermal management and IR filtration |
| Housing | Light-tight reaction chamber with structural support for integrated photoreactor assembly |
| Brand | Chemplex |
|---|---|
| Origin | USA |
| Product Type | Imported Mylar® Polyester Film |
| Model | 106 |
| Thickness | 6.0 µm (0.24 mil) |
| Format | Pre-cut Circular Discs, Ø63.5 mm (2.5"), 500 pcs/box |
| Compliance | ASTM D882, ISO 527-3, USP <661.1>, RoHS-compliant |
| Application | X-ray Fluorescence (XRF), Energy-Dispersive X-ray Spectroscopy (EDX), Elemental Analysis Sample Support |
| Brand | CHEMSPEED |
|---|---|
| Origin | Switzerland |
| Model | CRYSTAL POWDERDOSE |
| Weighing Resolution | 10 µg |
| Weighing Range | 1 mg – 20 g |
| Sample Vial Capacity | 7 × 30 mL storage vessels |
| Footprint | 45 cm × 54 cm × 92 cm |
| Dosing Modes | Single-to-Single, Multi-to-Single, Multi-to-Multi |
| Brand | CHEMSPEED |
|---|---|
| Origin | Switzerland |
| Model | CRYSTAL SWILE |
| Weighing Resolution | 10 µg |
| Weighing Range | 0.1 mg – 5 mg |
| Sample Vials | 5 integrated storage vessels |
| Dispensing Tip | Disposable SWIN glass capillary |
| Platform Dimensions | 45 cm × 54 cm × 92 cm |
| Brand | CHEMSPEED |
|---|---|
| Origin | Switzerland |
| Model | FLEX EP |
| Batch Capacity | 15 × 2 L (with optional 0.5 L and 1 L volumetric flasks) |
| Volumetric Accuracy | Automated final volume adjustment to flask neck |
| Solid Dispensing Accuracy | ±0.1 mg |
| Liquid Dispensing Accuracy | ±0.4 mL |
| pH Control Range | 1.0–13.0 |
| Regulatory Compliance | Fully compliant with GMP and FDA 21 CFR Part 11 requirements |
| Integration | Native LIMS connectivity via ASTM E1578-compliant interface |
| Brand | CHEMSPEED |
|---|---|
| Origin | Switzerland |
| Model | FLEX QuEChERS |
| Sample Capacity | Up to 120 samples in 10 hours |
| Vessel Compatibility | 15 mL and 50 mL Falcon tubes |
| Automation Scope | Gravimetric salt dispensing, volumetric liquid dispensing, automated centrifugation, orbital shaking |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software | Integrated Chemspeed SWING® platform with audit trail and method versioning |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | AS80, AS90 |
| Sample Capacity | AS80 — 18 or 36 samples |
| Sample Vial Options | PP vials (6–50 mL) or borosilicate glass vials (16–30 mL) |
| Dimensions (W×H×D) | 270 × 380 × 200 mm (base) |
| Weight | ~9 kg each |
| Interface | RS-232 serial control |
| Compatibility | Designed for integration with Krüss laboratory instruments and third-party analyzers via configurable serial protocol |
| Brand | JULABO-Chemtron |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lab 745 |
| Price | Upon Request |
| Measurement Range | 0–200 % saturation / 0–20 mg/L |
| Temperature Range | −10 to 100 °C |
| Resolution | 1 % / 0.01 mg/L / 0.1 °C |
| Temperature Compensation | Automatic NTC 30 kΩ or fixed-value compensation |
| Accuracy | ±1 digit, ±0.5 % of reading, ±0.1 °C (5–50 °C) |
| Electrode Interface | 8-pin polarographic or galvanic probe connector |
| Communication Interface | 4-pin USB |
| Calibration | Single-point, temperature-compensated |
| Data Logging Capacity | 4000 records (timestamp, DO value [mg/L and %], temperature) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TCSS |
| Control Accuracy | ±0.1 °C (Class 0.1) |
| Display | 5" TFT Touchscreen |
| Programmable Segments | 30-step |
| Sensor Compatibility | Pt100, Thermocouples (Type J/K/T/E/B/R/S/N), RTDs |
| Control Algorithm | AI-enhanced PID with Adaptive Learning |
| Communication Interfaces | RS232, RS485, Ethernet, USB-A |
| Safety Features | Over-temperature Cut-off, Alarm Output, 4 kV EFT Immunity |
| Power Architecture | Dual-CPU (ARM for HMI & Data Logging |
| Brand | Chu Ding |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HMP-01 |
| Quotation | Upon Request |
| Sterilization Temperature Range | 90–125 °C |
| Sterilization Time Range | 1–99 min |
| Vessel Capacity | 10 L |
| Heating Power | 2000 W |
| Stirring Speed | 1–80 rpm |
| Operating Pressure Range | 1.2–1.5 bar |
| Safety Valve Activation Pressure | 1.7 bar |
| Sample Loading Temperature Range | Ambient to 80 °C |
| Temperature Accuracy | ±1 °C |
| Dimensions (W×D×H) | 500 × 560 × 590 mm |
| Net Weight | 20 kg |
| Brand | Cilabs |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | In-Situ FTIR Characterization System with High-Vacuum Chamber and Transmission Quartz Cell |
| Pricing | Upon Request |
| Brand | Cilas |
|---|---|
| Power Rating | 500W / 350W / 150W |
| Lamp Type | Spherical Quartz Mercury Vapor Arc Lamp |
| Operating Voltage | 220–240 V AC, 50/60 Hz |
| Arc Gap | ≤ 2.5 mm |
| UV Output Spectrum | 254 nm (strong line), 365 nm (main UVA peak), 405 nm, 436 nm, 546 nm, 578 nm |
| Envelope Material | Fused Silica (UV-Grade Quartz) |
| Cooling Requirement | Forced-air or water-cooled (model-dependent) |
| Lifetime | ≥ 1,000 hours (at rated power, proper cooling) |
| Compliance | IEC 62471 (Photobiological Safety), RoHS 2011/65/EU |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | CK-1 |
| Dimensions | 60 × 60 × 8 mm (W × D × H) |
| Weight | 55 g |
| Material | Borosilicate Glass Base, Silicone Rubber Gasket, Stainless Steel Clamping Fixture |
| Accessories Included | 100 pcs Glass Coverslips, Silicone Grease, Silicone Rubber Gasket |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Cleanert M96 |
| Type | 96-Well Plate-Based Solid-Phase Extraction (SPE) and Protein Precipitation Platform |
| Configuration | Benchtop, Vacuum-Driven or Positive-Pressure Assisted |
| Intended Use | High-Throughput Biological Sample Cleanup Prior to LC-MS, HPLC, or ELISA Analysis |
| Brand | CME (China Education Goldsource) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (PRC) |
| Model Options | 10W, 20W, 120W |
| Pricing | Available Upon Request |
| Brand | CNI (China Education Goldsource) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | REF-SC-2x2-M |
| Calibration | NREL-traceable certificate included |
| Irradiance Range | 0–3.500 sun (1 sun = 1000 W/m², AM1.5G, 25 °C) |
| Irradiance Accuracy | ±0.1% at 1.0000 sun (23 °C), ±0.2% + 2 counts elsewhere |
| Temperature Range | 0–199.9 °C |
| Temp Accuracy | ±0.5 °C typical (24–26 °C), ±1.2 °C max (10–40 °C) |
| Analog Outputs | 1 V/sun (irradiance), 10 mV/°C (temperature) |
| Dimensions | 151 × 95 × 178 mm |
| Weight | 1.8 kg |
| Operating Environment | 10–40 °C, 0–90% RH non-condensing |
| Brand | Cnonline |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | ST-01 |
| Price Range | USD 56,000 – 70,000 (FOB) |
| Waste Category | Solid Hazardous Waste |
| Applicable Sectors | Academic & Industrial Laboratories, Healthcare Facilities, Chemical Manufacturing Plants |
| Storage Principle | Controlled Interim Containment |
| Total Storage Capacity | 1600 L |
| Regulatory Compliance | GB 18597–2023, GB 15562.2–1995, HJ 2025–2012 |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Flow Range | 0.05–5 LPM |
| Accuracy | ±0.8% of reading, ±0.2% of full scale |
| Repeatability | ±0.2% |
| Response Time | ≤50 ms |
| Operating Temperature | −10 to 50 °C |
| Pressure Drop | Low (LFE-based) |
| Wetted Materials | 302/303/410 SS, Viton®, silicone RTV, glass-filled nylon, aluminum, brass, silicon, borosilicate glass |
| Process Connection | 1/8" NPT(F) |
| Control Output | 0–5 VDC, 4–20 mA optional |
| Communication Interface | RS-232 |
| Display | 7-line × 4-digit LCD (0.25" digit height) |
| Gas Compatibility | 30 standard gases including N₂, O₂, CO₂, H₂, He, Ar, CH₄, C₃H₈, SF₆, and more |
| Turndown Ratio | 100:1 |
| Certifications | NIST-traceable calibration certificate included |
| Power Supply | 120/230 VAC adapter included |