Other Common Laboratory Equipment
Filter
Showing 241–270 of 387 results
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Jianhu |
| Pricing | Available Upon Request |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JT-GHX-DC |
| Light Source Compatibility | Mercury, Xenon, and Metal Halide Lamps (0–1000 W for Hg/Xe |
| Reaction Vessel Options | Quartz tubes (30 mL, 50 mL) or custom sizes |
| Sample Capacity | 8-position magnetic stirring (configurable to 6 or 12) |
| Cooling System | Dual-layer quartz cold finger with external recirculating chiller (cooling capacity >1000 W |
| temp range | −5 °C to 100 °C) |
| Safety | Overtemperature cutoff, radiation-shielded dark chamber with observation window, high-voltage lamp housing, integrated power sockets for lamps and stirrers |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JTZL-6C |
| Heating Method | 6-channel Far-Infrared Ceramic Heater (≤800 W per channel) |
| Distillation Capacity | 6 samples simultaneously |
| Distillation Rate | 12 mL/min |
| Temperature Range | Ambient to 320 °C |
| Endpoint Control | Dual-mode (gravimetric ±2 mL accuracy or timer 0–999 min) |
| Cooling System | Built-in air-cooled recirculating water unit |
| Display | 7-inch capacitive touch LCD |
| Single-Channel Temperature Control | Yes |
| Anti-Suck-Back | Electromagnetic vacuum valve |
| Power Supply | 220 V / 50 Hz |
| Flask Compatibility | Six 500 mL or 250 mL round-bottom flasks |
| Warm-up Time | 5–20 min |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KAN-7600 |
| Quotation | Upon Request |
| Airflow Range | 100–500 m³/h |
| Max. Cabin Static Pressure | ±2500 Pa (adjustable) |
| Standard Nozzle Diameters | Φ41 mm & Φ39 mm |
| Pressure Measurement Port | Integrated static pressure tap on flange |
| Control Method | Inverter-driven variable-speed blower with real-time feedback loop |
| Compliance | JIS D 1622 (Automotive Ventilation Performance Test), JIS B 8330 (Blower Testing and Inspection) |
| Brand | Advantec (Distributor) |
|---|---|
| Origin | Japan |
| Model | PAN160-7A |
| Output | 0–160 V / 0–7 A |
| Max. Power | 1120 W |
| Line Regulation (CV) | ≤0.01% + 2 mV |
| Load Regulation (CV) | ≤0.02% + 5 mV |
| Ripple & Noise (rms) | <1 mV |
| Temperature Coefficient (CV) | 100 ppm/°C |
| Transient Response Time (20% load step) | ≤50 µs |
| OVP, OTP, Foldback Current Limiting, Front Terminal Cover, Isolation Voltage | ±500 Vdc to chassis |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), UL/cUL 61010-1 |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VTC-100PAX |
| Quotation | Upon Request |
| Motor Power | 100 W |
| Input Power | 220 V, 50 Hz |
| Max Speed | 10,000 rpm |
| Min Speed | 500 rpm |
| Acceleration Range | 100–2,000 rpm/s |
| Program Steps per Recipe | 9 |
| Time per Step | 0–999 s |
| Stored Recipes | 6 |
| Vacuum Requirement | 0.06–0.09 MPa |
| Vacuum Port OD | 6 mm |
| Dimensions (W×D×H) | 270 × 430 × 400 mm |
| Weight | 12 kg |
| Brand | Advantec |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | KDC2-D01 |
| Power Supply | Single-phase AC 100 V, 50/60 Hz |
| Dimensions (W×D×H) | 250 × 280 × 260 mm |
| Weight | 9 kg |
| Airflow Capacity | 1.3 m³/min |
| Maximum Static Pressure | 9.0 kPa |
| Hose Diameter | Φ50 mm (Φ38 mm optional) |
| Packaging Dimensions | 400 × 390 × 310 mm |
| Gross Weight | 10 kg |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SBC-2 |
| Vacuum System | Mechanical Pump + Turbo Molecular Pump |
| Ultimate Vacuum | ≤2 × 10⁻³ Pa |
| Sputtering Voltage | 3 kV |
| Sample Stage Motion | Planar Rotation + Tilt Rotation |
| Carbon Evaporation Target Diameter | Φ38 mm |
| Sample Holder Diameter | Φ40 mm |
| Bell Jar Dimensions | Φ250 mm × H340 mm |
| Evaporation Glass Dome | Φ88 mm × H140 mm |
| Sputtering Glass Dome | Φ88 mm × H57 mm |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | CDS 5200 |
| Pyrolysis Temperature Range | Ambient to 1400 °C (±0.1 °C accuracy) |
| Maximum Pressure Resistance | 500 PSI (3400 kPa) |
| Heating Rates | 10–20,000 °C/sec (pulse), 0.01–999.9 °C/sec or 0.01–999.9 °C/min (programmed) |
| Transfer Line Max Temp | 350 °C |
| Interface Temp | ≥350 °C |
| Reactor | 3″ × 1/4″ OD 316 stainless steel, catalyst-compatible up to 800 °C |
| Atmosphere Options | N₂, air, or custom gas |
| Integrated Cold Trap | Yes, with thermal desorption capability |
| Sample Path Materials | Inert (e.g., quartz, deactivated metal) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MAX-L |
| Pricing | Upon Request |
| Translation Stage | Contact Manufacturer |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MiniLab3000 |
| Pricing | Available Upon Request |
| XYZ Stage | Custom-configurable precision linear motor-driven stage with ±0.1 mm positional repeatability |
| Liquid Handling Accuracy | ≤±0.5% CV at 10 µL–1000 µL |
| Dispense Precision | ≤±0.3% CV |
| Needle Wash | Dual-stage internal/external rinse with active waste evacuation pump |
| Sample Capacity | Up to 288 × 2 mL vials (standard configuration) |
| Vial Compatibility | 2 mL–100 mL screw-cap or crimp-top vials |
| Mixing Method | Contactless orbital vortexing (programmable speed/duration) |
| Temperature Control Option | Integrated Peltier-based sample deck heating/cooling module (–10 °C to +80 °C, ±0.5 °C stability) |
| Compliance | Designed for GLP/GMP environments |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | PT2000 |
| Sample Capacity | 110 positions (water & soil) |
| Purge Temperature Range | Ambient to 95 °C |
| Trap Desorption Temperature | Up to 350 °C |
| Internal Standard Delivery | Electronic pressure-controlled, ≤1 s precision dispensing |
| Cleaning Protocol | Dual-mode (methanol + hot water) |
| Soil Penetration | Pneumatically assisted needle with back-pressure compensation and reverse purge |
| Software | Integrated method editor with emergency sample insertion, bake-in-method embedding, and automated calibration curve generation |
| Compliance | Designed for ASTM D6866, EPA Methods 502.2, 524.2, 624, 8260D, and ISO 15681-2 workflows |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | REVO |
| Pricing | Upon Request |
| Translation Stage | Available upon consultation |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | SH150-3000 |
| Cooling Capacity | 3.0 kW @ 20°C |
| Temperature Range | –10°C to +40°C |
| Temperature Stability | ±0.1°C |
| Refrigerant | R-134a (ODP = 0) |
| Flow Rate | Adjustable up to 30 L/min |
| Pressure Display Resolution | 0.01 bar |
| Touchscreen Interface | 7-inch capacitive LCD with real-time data logging |
| Remote Monitoring | Ethernet & Wi-Fi enabled, compatible with LabTech CloudConnect™ mobile app |
| Safety Alarms | High/Low temperature, low flow, low level, high return temperature, pressure deviation |
| Compliance | CE, RoHS, ISO 9001 certified |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Silent Enclosure |
| Price | Upon Request |
| Translation Stage | Not Applicable |
| Displacement Platform | Not Integrated — Custom Mounting Available per Pump Configuration |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZDY-502 |
| Pricing | Upon Request |
| Translation Stage | Contact Manufacturer |
| Measurement Range | 0.1–250 mg H₂O |
| Resolution | 0.1 mg |
| Polarization Current Accuracy | 1 μA ± 0.2 μA |
| Repeatability | ±0.5% RSD |
| Power Supply | (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Data Storage Capacity | 200 methods/results |
| Interface | USB + RS232 |
| GLP Compliance | Yes |
| Safety Features | Anti-spill, anti-siphon waste bottle, KF reagent isolation, auto-cleaning, overflow protection |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-11 |
| Output Channels | 4 independent parallel outputs |
| Voltage Range | 4–1000 V (1 V resolution) |
| Current Range | 4–500 mA (1 mA resolution) |
| Power Range | 4–300 W (1 W resolution) |
| Dimensions (W×D×H) | 303 × 364 × 137 mm |
| Weight | 7.5 kg |
| Display | Large LCD with real-time parameter monitoring |
| Control Modes | Constant Voltage / Constant Current / Constant Power |
| Programming | 10 stored protocols, up to 9 steps per protocol |
| Protection Features | Over-voltage, over-current, over-load, load variation, and no-load detection with automatic shutdown |
| Memory | Non-volatile program storage |
| Cooling | Integrated forced-air cooling system |
| Compliance | Designed for laboratory electrophoresis applications per IEC 61010-1 safety standards |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-15D |
| Output Channels | 4 parallel independent outputs |
| Voltage Range | 20–5000 V (2 V resolution) |
| Current Range | 3–300 mA (1 mA resolution) |
| Power Range | 5–300 W (1 W resolution) |
| Display | Large LCD showing real-time voltage, current, power, and timer |
| Programming | 10 stored protocols, each with up to 9 programmable steps |
| Operating Modes | Constant Voltage, Constant Current, Constant Power, Timer Mode, Volt-Hour Mode, Stepwise Program Mode |
| Safety Features | Overload protection, short-circuit auto-shutdown, over-temperature monitoring, low-current maintenance mode, power-fail recovery |
| Dimensions (W×D×H) | 278 × 349 × 110 mm |
| Weight | 4.0 kg |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Model | DYY-2C |
| Output Modes | Constant Voltage & Constant Current |
| Voltage Range | 0–600 V (1 V resolution) |
| Current Range | 0–100 mA (1 mA resolution) |
| Max Power | 60 W |
| Dimensions (W × D × H) | 235 × 295 × 95 mm |
| Weight | 2.5 kg |
| Display | Digital LCD showing real-time V, I, and timer |
| Protection | Overvoltage, overcurrent, overload, variable-load, and no-load detection with auto-shutdown |
| Cooling | Passive convection |
| Output | 4 parallel DC output terminals |
| Control | Microprocessor-based digital regulation with memory recall |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Model | DYY-6D |
| Output Channels | 4 independent parallel outputs |
| Voltage Range | 6–600 V (1 V resolution) |
| Current Range | 4–600 mA (1 mA resolution) |
| Power Range | 1–300 W (1 W resolution) |
| Display | Large LCD showing real-time V, I, P, and timer |
| Memory | 10 user-programmable 3-step protocols |
| Control | Microprocessor-based with continuous parameter adjustment |
| Safety | Overload, short-circuit, over-temperature, and automatic shutdown protection |
| Dimensions (W×D×H) | 246 × 360 × 80 mm |
| Weight | 3.2 kg |
| Compliance | Designed for GLP-compliant electrophoresis workflows in molecular biology labs |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Origin | Beijing, China |
| Model No. | 112-0730 |
| Output Voltage Range | 2–300 V (1 V resolution) |
| Output Current Range | 5–2000 mA (2 mA resolution) |
| Max. Power Output | 300 W |
| Dimensions (W × D × H) | 315 × 290 × 128 mm |
| Weight | 5 kg |
| Output Channels | 4 independent parallel outputs |
| Protection Features | Over-voltage, over-current, over-load, and load-mismatch detection |
| Control System | Microprocessor-based with real-time parameter adjustment |
| Display | LCD showing simultaneous voltage, current, and timer values |
| Memory Function | Parameter storage for repeat protocols |
| Power Architecture | High-efficiency switching-mode power supply |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-8C |
| Output Modes | Constant Voltage & Constant Current |
| Voltage Range | 5–600 V (1 V resolution) |
| Current Range | 2–200 mA (1 mA resolution) |
| Max Power | 120 W |
| Output Channels | 4 parallel DC outputs |
| Dimensions (W×D×H) | 235 × 295 × 95 mm |
| Weight | 2.5 kg |
| Display | LCD showing real-time voltage, current, and timer |
| Protection Features | Over-voltage, over-current, over-load, load variation, and no-load detection |
| Control System | Microprocessor-based with memory recall function |
| Cooling | Integrated forced-air cooling system |
| Compliance | Designed for laboratory electrophoresis applications per standard molecular biology protocols (e.g., SDS-PAGE, agarose gel electrophoresis) |
| Brand | Meiyingpu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 316L |
| Pricing | Available Upon Request |
| Custom Height Adjustment | Yes |
| Material | ASTM A240 UNS S31603 316L Stainless Steel |
| Standard Diameters (cm) | Φ25, Φ30, Φ35, Φ40, Φ45, Φ50, Φ55, Φ60, Φ70 |
| Standard Heights (cm) | 25, 30, 35, 40, 45, 50, 60, 70, 80 |
| Surface Finish | Electro-polished (Ra ≤ 0.4 µm) |
| Compliance | Meets ASTM A240, ISO 8502-3, and FDA 21 CFR Part 110 for food contact surfaces |
| Brand | Nano-Master |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Equipment |
| Model | NTE-3500 (M) |
| Price Range | USD 110,000 – 140,000 |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-152 |
| Coarse Travel (X/Y/Z) | 25 mm / 20 mm / 25 mm |
| Fine Adjustment Resolution | Sub-micrometer (via optional single-axis micrometer drive) |
| Dimensions (W×D×H) | 95 × 36 × 135 mm |
| Weight | 320 g |
| Standard Accessory | B-8B Spherical Joint |
| Optional Upgrade | Uniaxial Micrometer Drive (pipette-aligned axis) |
| Brand | NAYO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A96 |
| Pricing | Available Upon Request |
| Brand | ADVANTEC (Yan Hua Dong Yang) |
|---|---|
| Origin | Japan |
| Model | 10-905 |
| Type | Manual Date/Number Embossing Punch |
| Max. Sheet Capacity | 10 sheets (64 g/m² paper, 8-digit imprint) |
| Cycle Time | 1.5 s/cycle (50 Hz) / 1.2 s/cycle (60 Hz) |
| Dimensions | 214 × 295 × 485 mm |
| Weight | 12.7 kg |
| Die Block Compatibility | MOLE 905-208 |
| Power Supply | None (Manual Operation) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Dispet Ex |
| Dispensing Range | 0.2–10 mL (DP-10), 0.4–20 mL (DP-20), 1–5 mL (DP-5), 2–10 mL (DP-10) |
| Minimum Increment | 0.05–0.25 mL |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤0.2% |
| Bottle Compatibility | Ø22 mm (for DP-5/DP-10), up to Ø45 mm (with optional adapters) |
| Adapter Options | DP-1118 (18 mm), DP-1119 (19 mm), DP-1122 (22 mm), DP-1124 (24 mm), DP-1125 (25 mm), DP-1128 (28 mm), DP-1133 (33 mm), DP-1138 (38 mm), DP-1145 (45 mm) |
| Included Accessories | One 220 mm flexible PTFE-lined tubing (user-cuttable) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET EX II |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28, GL-32, GL-45 (bottles sold separately) |
| Liquid Contact Materials | Chemically resistant PTFE, FEP, and ETFE components |
| Design | Handheld, portable, ergonomic manual dispenser |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET Mini |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28 standard thread |
| Liquid Contact Materials | Chemically resistant PTFE, ETFE, and FEP components |
| Regulatory Compliance | Designed for ISO 8655-compliant volumetric dispensing procedures |