| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HP-BD48A |
| Price Range | USD 1,400 – 2,800 |
| Illuminant | Simulated D65 |
| Geometry | Diffuse/0° (d/0) |
| Sphere Diameter | 150 mm |
| Aperture | 25 mm |
| Repeatability | σ(Y₁₀) < 0.1, σ(x₁₀, y₁₀) < 0.001 |
| Accuracy | ΔY₁₀ < 1.0, Δx₁₀/Δy₁₀ < 0.01 |
| Sample Size | ≥Φ30 mm, ≤40 mm thickness |
| Power Supply | AC 220 V, 50 Hz, 0.3 A |
| Operating Environment | 10–30 °C, RH ≤85% |
| Dimensions | 364 × 264 × 400 mm |
| Weight | 17 kg |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | HP-CQYD |
| Cutting Width Options | 10 mm, 15 mm, 20 mm, 25 mm, 30 mm, 50 mm |
| Tolerance | ±0.1 mm |
| Blade Material | High-Carbon Steel |
| Handle Material | Ergonomic ABS + Stainless Steel Reinforcement |
| Custom Length | Unlimited (user-defined specimen length) |
| Price | USD 52 (FOB Shandong) |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP-DLT |
| Max. Test Load | 50 N |
| Load Resolution | 0.001 N |
| Force Accuracy | ±1% of reading |
| Displacement Resolution | 0.01 mm |
| Speed Range | 1–600 mm/min |
| Test Space (Compression) | 300 mm |
| Dimensions (W×D×H) | 540 × 280 × 1450 mm |
| Weight | ~70 kg |
| Power Supply | 200 V, 50 Hz |
| Operating Environment | 10–45 °C, 20–80% RH |
| Compliance | GB/T 5019.2–2009 |
| Display | Full Chinese LCD interface |
| Control Mode | Touch-key + optional PC-based software (USB/RS232) |
| Protection | Overload protection, mechanical limit switches |
| Accuracy Class | Class 1 (GB/T 228.1) |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HP-DLT |
| Price Range | USD 1,400 – 4,200 |
| Max Test Force | 50 N (optional ranges available) |
| Force Resolution | 0.001 N |
| Force Accuracy | ±1% of reading |
| Displacement Resolution | 0.01 mm |
| Displacement Accuracy | ±1% |
| Speed Range | 1–600 mm/min (digital DC motor control) |
| Test Space | 300 mm |
| Dimensions (W×D×H) | 540 × 280 × 1450 mm |
| Weight | ~70 kg |
| Power Supply | 200 V, 50 Hz |
| Operating Environment | 10–45 °C, 20–80% RH |
| Compliance | GB/T 5019.2–2009 |
| Display | Full Chinese LCD interface |
| Control Mode | Touch-key + optional PC software (USB/RS232) |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP-YSY3000 |
| Measurement Range | 60–3000 N |
| Accuracy | <1% (typical ≤0.3%) |
| Resolution | 0.1 N |
| Platen Speed | 12.5 ± 2.5 mm/min |
| Platen Diameter | 120 mm (customizable) |
| Max Platen Gap | 80 mm (customizable) |
| Power Supply | AC 220 V, 3 A, 50 Hz |
| Dimensions (W×D×H) | 360 × 330 × 510 mm |
| Weight | ~55 kg |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HP612H |
| Price Range | USD 1,400 – 4,200 |
| Load Capacity Options | 50 N (also available: 100 N, 500 N, 1000 N) |
| Resolution | 0.1 N |
| Accuracy | ±0.5% FS |
| Test Speed | 1–300 mm/min |
| Probe Diameter | 2 mm |
| Parallelism of Compression Plates | <0.025 mm |
| Lower Platen Diameter | 100 mm |
| Dimensions (W×D×H) | 430 × 350 × 710 mm |
| Weight | 65 kg |
| Power Supply | 220 V, 50 Hz |
| Compliance | ASTM D1321-10 |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP622 |
| Key Specifications | Load Range 0–50 N |
| Resolution | 0.1 N |
| Accuracy | ±1% FS |
| Test Speed | 25 mm/min (adjustable 0–300 mm/min) |
| Sample Size | 75 mm × 75 mm |
| Clamp Aperture | Ø35 mm |
| Probe | Hemispherical, compliant with YY/T 0681.13–2014 |
| Dimensions | 330 × 335 × 550 mm |
| Weight | ~55 kg |
| Power Supply | 220 V, 50 Hz |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP622 |
| Compliance | YY/T 0681.13–2014, ASTM F1306–2016 |
| Force Range | 0–50 N |
| Resolution | 0.1 N |
| Accuracy | ±1% FS |
| Test Speed | 25 mm/min (adjustable 0–300 mm/min) |
| Sample Size | 75 mm × 75 mm |
| Clamp Aperture | Ø35 mm |
| Probe | Hemispherical, compliant with YY/T 0681.13 |
| Dimensions | 330 × 335 × 550 mm |
| Weight | ~55 kg |
| Power Supply | 220 V, 50 Hz |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BNY-01 |
| Measurement Range | 3000 N (customizable) |
| Resolution | 0.1 N |
| Specimen Dimensions | 420 mm × 320 mm (customizable) |
| Specimen Height Capacity | 10–200 mm (customizable) |
| Overall Dimensions | 550 × 490 × 800 mm (L×W×H) |
| Weight | 36 kg |
| Operating Environment | 23 ± 2 °C, RH ≤ 80 % (non-condensing) |
| Power Supply | 220 V, 50 Hz |
| Compliance | GB/T 16491, GB 4857.16, ASTM D642, ASTM D4169, TAPPI T804, ISO 2872, ISO 12048, JIS Z0212, GB/T 10004 |
| Brand | Jinhuatester |
|---|---|
| Model | CHY-01 |
| Measurement Principle | Mechanical Contact with Controlled Load & Defined Foot Area |
| Measurement Range | 0–5 mm (customizable fixtures available) |
| Resolution | 0.1 µm |
| Accuracy | ±0.5 µm |
| Measuring Pressure | 17.5 ± 1 kPa (for films), 100 ± 1 kPa (for paper, requires optional paper-specific anvil) |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode) |
| Traverse Speed | 10 mm/min (adjustable) |
| Display | Color LCD with real-time values, statistics (mean, min, max, SD), and graphical trend view |
| Data Output | RS232 serial interface |
| Optional Accessories | Automated multi-point sample feeder, thermal printer module |
| Compliance | Designed per ISO 4593, ASTM D6988, ISO 534, TAPPI T411, and GB/T 451.3 |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 454 × 352 × 500 mm |
| Net Weight | 30 kg |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HST-01 |
| Sealing Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sealing Time Range | 0.1–999.9 s |
| Delay Time Range | 0.1–999.9 s |
| Sealing Pressure Range | 0.05–0.7 MPa |
| Sealing Area | 260 mm × 10 mm (customizable) |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 360 × 270 × 375 mm |
| Weight | 30 kg |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MXD-02 |
| Measuring Range | 5 N (standard), optional 10 N / 30 N |
| Accuracy | ±0.2% FS |
| Test Stroke | 330 mm |
| Slider Masses | 200 g, 500 g (standard) |
| Test Speed | 0–1000 mm/min (adjustable) |
| Specimen Height Capacity | 0–30 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 100 W |
| Dimensions (L×W×H) | 640 × 300 × 230 mm |
| Net Weight | 22 kg |
| Compliance | GB 10006–1998, ISO 8295–1995, ASTM D1894–01, TAPPI T816 |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NNY-01 |
| Price | USD 145 (approx. based on ¥1000) |
| Sensor Range | 0–6 MPa |
| Safety Overload | 7.2 MPa |
| Combined Accuracy | <0.5% FS |
| Display Resolution | 0.0001 MPa |
| Pressurization Rate | 0.4–0.58 ±0.1 MPa/s (adjustable, compliant with ISO 7458 and GB/T 4546-2008) |
| Test Medium | Deionized Water |
| Operating Temperature | 5–50 °C |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 0.6 kW (integrated RCD protection) |
| Dimensions | 600 × 400 × 1240 mm |
| Weight | 136 kg |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NNY-01 |
| Sensor Range | 0–6 MPa (7.2 MPa safe overload) |
| Combined Accuracy | <0.5% FS |
| Display Resolution | 0.0001 MPa |
| Pressure Ramp Rate | 0.4–0.58 ±0.1 MPa/s (adjustable, equivalent to 5.8 ±1 bar/s) |
| Test Medium | Deionized Water |
| Operating Temperature | 5–50 °C |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 0.6 kW (integrated RCD protection) |
| Dimensions | 600 × 400 × 1240 mm |
| Weight | 136 kg |
| Brand | Jinhuatester |
|---|---|
| Model | RCJ-01 |
| Application | Thermal shock resistance testing of glass pharmaceutical and beverage containers |
| Standards Compliance | GB/T 4547–2007, YBB 00182003–2015 |
| Temperature Range | 10–90 °C |
| Temperature Accuracy | ±0.5 °C |
| Hot/Cold Bath Capacity | 70 L each |
| Power Consumption | 6500 W |
| Lift Load Capacity | 30 kg |
| Basket Dimensions | Ø280 × 320 mm |
| Overall Dimensions | 1000 × 780 × 1600 mm |
| Weight | 185 kg |
| Control System | 7-inch color touchscreen with PID temperature control |
| Construction | Stainless steel hot/cold baths and motorized lifting basket |
| Safety | Integrated earth-leakage circuit breaker |
| Environmental Operating Conditions | 10–40 °C ambient, ≤50% RH |
| Brand | Jiubin |
|---|---|
| Model | JB-117A-F |
| Origin | Shanghai, China |
| Application | Packaging & Aerospace Composite Materials Testing |
| Max Load Capacity | 20 kN / 50 kN (selectable) |
| Effective Test Height | 1000 mm |
| Effective Test Width | 380 mm (customizable) |
| Force Accuracy | ±0.5% of full scale |
| Displacement Resolution | 0.001 mm |
| Speed Range | 0.001–500 mm/min |
| Force Resolution | 1/500,000 |
| Power Supply | AC 220 V, 50 Hz |
| Weight | ~350 kg |
| Operating Temperature | –20 ± 2 °C or 22 ± 5 °C (ambient) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SYJ-50QY |
| Pricing | Upon Request |
| Max Sample Diameter | Ø90 mm × 2 mm |
| Vacuum Source | Clean Compressed Air (0.2–0.6 MPa) |
| Spindle Speed | 300–6500 rpm (recommended: 5000 rpm) |
| Feed Motor Speed | 0.5–7.5 rpm |
| Feed Rate | 0.014–0.23 mm/s |
| Sample Thickness Range | 0.3–1 mm |
| Operating Environment | 25 °C ±15 °C, ≤85% RH (non-condensing), Altitude <1000 m |
| Cooling | Adjustable Water-Based Coolant Flow |
| Dimensions (W×D×H) | 470 mm × 700 mm × 1100 mm |
| Weight | 40 kg |
| Required Utilities | AC 220 V, 50 Hz |
| Water Connection | Inlet & Drain Required |
| Ventilation | Mandatory |
| Workbench Minimum | 600 mm × 850 mm × 700 mm |
| Brand | KRK |
|---|---|
| Origin | Japan |
| Model | KRK-2500Ⅱ |
| Type | Single-Disk Refiner |
| Liquid-Wetted Material | SUS-316 Stainless Steel |
| Disc Diameter | 305 mm |
| Rotor Speed | 3,000 rpm (standard) |
| Motor Power | 22 kW / 30 kW |
| Feed Screw Speed | 30–300 rpm |
| Gap Resolution | 0.01 mm |
| Overall Dimensions | 1030 × 1440 × 1270 mm |
| Weight | 800 kg |
| Electrical Supply | 200/220 V, 3-phase DC, 50/60 Hz, 107 A |
| Cooling Water Required | Yes |
| Brand | KRK |
|---|---|
| Origin | Japan |
| Model | KRK-2511 |
| Power Supply | 380 V, 3-phase, 50/60 Hz |
| Net Weight | 450 kg |
| Gross Weight | 500 kg |
| Dimensions (W×D×H) | 780 × 550 × 1100 mm |
| Roll-to-Plate Linear Speed Differential | 6 ± 0.2 m/s |
| Compliance | ISO 5264-2:1979, QB/T 1463–1992 |
| Brand | LABC |
|---|---|
| Origin | Germany |
| Model | DN120 |
| Cell Volume | ~200 mL |
| Single-Side Contact Area | ~1.00 dm² |
| Double-Side Contact Area | ~2.00 dm² |
| Construction | Stainless Steel Body |
| Cap Thread | GL14 |
| Cap Material | PBT Housing with PTFE/Silicone Seal |
| Sealing Elements | Two FEP/Silicone O-Rings (Top & Bottom Grooves) |
| Compliance | EU Regulation No. 10/2011, EN 13130, ISO 21768, GB 5009.156–2016 |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 060101 |
| Price | Upon Request |
| Energy Range Options | 0–6 J (0.003 J resolution) |
| Pendulum Angle | 90° arc |
| Impact Tip Geometry | Triangular pyramid (ISO 3036-compliant) |
| Display Accuracy | ±0.1 J |
| Adjustable Clamp Pressure | Yes |
| Data Interface | RS-232 |
| Power Supply | 230 V, 50 Hz |
| Dimensions (W×D×H) | 860 × 365 × 620 mm |
| Weight | 250 kg |
| Software Compatibility | REGISTRA III data acquisition and statistical analysis suite |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model Series | C130H, C230H, C330H, C390H, G2/131, VAC-V2, VAC-VBS, ET-01, MF-01, FT-F1, TS-01, RT-01, MCJ-01A, YGJ-02A, BLJ-02, GC-7800, C830, ERT-01, Migration Test Cells |
| Compliance Standards | ASTM D3985, ASTM F1249, ISO 15106-2, ISO 15106-3, GB 31604.1-2015, GB 5009.156-2016 |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Principle | Differential Pressure Method (ISO 15105-1, ASTM D1434) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Chamber Count | 6 independent cavities |
| Standard Test Area | 38.48 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Test Gases | O₂, N₂, CO₂ (H₂/CH₄ available on custom configuration) |
| Test Pressure | 10–150 kPa (adjustable, ΔP stability <0.2 kPa) |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C650H Headspace |
| Price Range | USD 1,400 – 7,000 |
| O₂ Measurement Range | 0.2–21% (v/v) |
| O₂ Accuracy | ±0.2% (v/v) |
| CO₂ Measurement Range (optional) | 2–100% (v/v) |
| CO₂ Accuracy (optional) | ±2% (v/v) |
| Sample Volume Required | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Weight | 5.5 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 |
| Display | LCD with bilingual (EN/CN) menu interface |
| Data Storage | Internal memory |
| Printer | Integrated thermal micro-printer |
| Brand | Labthink |
|---|---|
| Model | C670M |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Test Methods | ASTM D1709 (Method A & B), ISO 7765-1:1988, GB/T 9639.1–2008, JIS K7124-1 |
| Measurement Range | Method A: 50–2000 g |
| Method B | 300–2000 g |
| Mass Resolution | ±0.5% |
| Sample Clamping | Pneumatic (0.6 MPa required, Φ8 mm polyurethane tubing interface) |
| Sample Size | >150 mm × 150 mm |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 70 kg |
| Dimensions (A Method) | 500 × 450 × 1320 mm (L×W×H) |
| (B Method) | 500 × 450 × 2160 mm (L×W×H) |
| Standard Configuration | Method A setup, 7″ color touchscreen HMI, built-in thermal printer |
| Optional Accessories | Method B conversion kit, Labthink SmartTest™ software suite, RS232 communication cable |
| Brand | Labthink |
|---|---|
| Model | MXD-02 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Load Range | 0–5 N |
| Accuracy Class | 0.5 |
| Travel Distance | 70 mm / 150 mm |
| Standard Slider Mass | 200 g (customizable) |
| Test Speeds | 100 mm/min, 150 mm/min (adjustable) |
| Ambient Conditions | 23 ± 2 °C, 20–70 %RH |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 630 × 360 × 230 mm |
| Net Weight | 33 kg |
| Compliance | GB 10006, ISO 8295, ASTM D1894, TAPPI T816 |
| Brand | Lloyd Instruments |
|---|---|
| Origin | USA |
| Model | FT1 |
| Load Capacity | 1 kN |
| Crosshead Travel | 500 mm |
| Speed Range | 0.05–2032 mm/min |
| Speed Accuracy | <0.2% (steady-state) |
| Force Sensor Accuracy | <0.5% |
| Extension Resolution | <2 µm |
| Data Sampling Rate | 8 kHz |
| Sensor Options | YLC Series (10 N, 50 N, 100 N |
| Standards Compliance | ASTM D1894, ISO 8295, TAPPI T549 |
| Onboard Test Methods | 3 preconfigured (static/kinetic COF, peak/average force) + 7 user-defined |
| Data Storage | Up to 600 test records |
| Brand | Messmer Buchel |
|---|---|
| Origin | Netherlands |
| Model | 58-06 |
| Test Pressure Range | 490–5000 kPa (adjustable) |
| Standard Test Pressure | 1980 kPa |
| Measurement Range | 0.2–6.5 µm (normal mode) |
| Measuring Ring Width | 51 µm |
| Measuring Ring Circumference | 10.0 cm |
| Clamping Pressure Options | 500 / 1000 / 2000 kPa (100–5000 kPa fully adjustable) |
| Air Permeability Range (optional) | 0–10000 mL/min |
| Power Supply | 110 V/60 Hz or 220 V/50 Hz |
| Compressed Air Requirement | 600 kPa, clean and dry |
| Dimensions (L×W×H) | 558 × 430 × 380 mm |
| Weight | 39 kg |
| Data Output | RS-232 or thermal printer |
| Compliance | GB/T 2679, ISO 8791-4, TAPPI T555 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W 3/38 H |
| Application | PV Backsheet & Encapsulant Barrier Testing |
| Compliance | ASTM F1249 |
| Detection Range | 0.05–200 g/(m²·day) |
| Sensor Type | Patented Modulated Infrared Detector |
| Chamber Configuration | Dual removable test cells (4 samples per run) |
| Control System | Fully automated temperature, RH, and carrier gas flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Measurement Principle | Modulated IR detection of water vapor in carrier gas stream |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W® 3/38 H |
| Detection Limit | 0.05 g/(m²·day) |
| Measurement Range | 0.05–200 g/(m²·day) |
| Test Chambers | 4 independent horizontal dual-membrane chambers |
| Compliance | ASTM F1249 |
| Sensor Type | Modulated Infrared (Patented MOCON) |
| Environmental Control | Automated temperature, RH, and N₂ flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Software Interface | Local PC GUI or optional touchscreen HMI |
| Test Mode Options | QC pass/fail mode, reference film validation, triplicate testing |