| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3022Plus |
| Measurement Gases | O₂, CO₂ |
| Principle | O₂ — Zirconia Electrochemical Cell |
| Sample Volume | 5 mL |
| Resolution | 0.01% |
| Accuracy | O₂ — ±(0.25% FS + 2% of reading) |
| CO₂ — ≤20% | ±2.0% of reading, >20%: ±3.0% of reading |
| O₂ Range | 0–96% vol |
| CO₂ Range | 0–100% vol |
| Minimum Analysis Time | 7 s |
| Display | 5″ capacitive touchscreen (720 × 1280) |
| Battery | Rechargeable 7500 mAh Li-ion (3.7 V), ~4 h continuous operation |
| Data Storage | 100,000 records internal + SD card expansion |
| Connectivity | Wi-Fi, USB 2.0 |
| Operating Temp. | 0–40 °C |
| RH | 5–90% (non-condensing) |
| Certifications | RoHS, FCC |
| Dimensions (L×W×H) | 104 × 187.5 × 72 mm |
| Weight | ~0.85 kg |
| Languages | Multi-language UI support (English, Spanish, French, German, Chinese, etc.) |
| Brand | SCS |
|---|---|
| Origin | USA |
| Model | CURPOD SPACE SAVR |
| Construction | Stainless Steel, Airtight Sealed Enclosure |
| Chamber Capacity | 18 Standard RPCs (15.5" × 23.5" × 7.75" |
| Gas Control | Onboard N₂-driven O₂ depletion with programmable O₂/CO₂ setpoints |
| Environmental Monitoring | Integrated digital sensors for O₂, CO₂, RH, and temperature |
| Data Logging | Cloud-connected real-time dashboard with full audit trail |
| Compliance Support | Designed for GLP-aligned recordkeeping |
| Automation Level | Fully autonomous operation with valve-controlled gas modulation and scheduled environmental profiles |
| Storage Duration | Up to 12 months at stabilized low-O₂, high-N₂ conditions (≤1% O₂ typical) |
| Brand | Danilee |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Sutherland 2000 |
| Price | ¥80,000 |
| Speed Settings | 21, 42, 85, 106 cycles/min |
| Load Options | 0.9 kg (2 lb), 1.8 kg (4 lb), optional 20 N weight |
| Display | LCD showing preset/remaining cycles |
| Compliance | ASTM D5264–92, GB/T 7705–2008 |
| Dimensions | 381 × 381 × 305 mm |
| Power Supply | 220 V, 50/60 Hz, single-phase, 2 A |
| Net Weight | 42 lbs |
| Auto-shutdown | Yes |
| Pre-stored test count memory | Yes |
| Brand | Danilee |
|---|---|
| Origin | USA |
| Model | Sutherland 2000 |
| Speeds | 21, 42, 85, 106 cycles/min |
| Load Options | 0.9 kg (2 lb), 1.8 kg (4 lb), optional 20 N weight |
| Compliance | ASTM D5264–92, GB/T 7705–2008 |
| Display | LCD with preset cycle counter |
| Power | 220 V, 50/60 Hz, single-phase, 2 A |
| Dimensions | 15 × 15 × 12 in |
| Net Weight | 42 lb |
| Test Modes | Dry rub, wet rub, wet smudge/transfer, wet smear, functional abrasion |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckMate 4 SV |
| Origin | Denmark |
| Gas Measurement | O₂ or O₂ + CO₂ |
| Principle | Zirconia (O₂), Electrochemical (O₂), Dual-Beam Infrared (CO₂), Optical Fluorescence (O₂) |
| Sampling Method | Non-invasive optical probe or minimally invasive needle-penetration |
| Minimum Sample Volume | None |
| Resolution | 0.001% |
| Accuracy | ±0.02% |
| Compliance | Designed for ISO 8573-1, ASTM F2714, USP <1207>, FDA 21 CFR Part 11–ready software architecture |
| User Interface | Multi-language capacitive touchscreen (10 languages) |
| Data Management | On-device storage with timestamped audit trail, optional PC-based Dansensor Insight™ software for multi-line monitoring and GLP/GMP-compliant reporting |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckPoint 4 |
| Origin | Denmark |
| Detection Gases | O₂ and CO₂ (selectable single or dual) |
| Measurement Principle | Electrochemical (O₂), Infrared (CO₂) |
| Portability | Handheld, battery-powered |
| Interface | Capacitive touchscreen with 10 language options |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned quality control environments |
| Power | Rechargeable Li-ion battery with rugged charging port |
| Accessories | Standard low-cost hypodermic needle probe (22G), optional protective boot |
| Auto-shutdown | Yes, energy-saving mode |
| Gas flow alarm | Visual and audible alert |
| Certifications | CE, RoHS, FDA-compliant design (non-invasive testing per 21 CFR Part 11 data integrity guidelines) |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | Lippke 5000 |
| Test Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Volume Capacity | 0–90,000 mL |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Brand | DERUI TESTING |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DR-ZB206A |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Accuracy | ±0.1 s |
| Measurement Range | 0–9999 s (three ranges: 1–15 s, 15–300 s, 300–9999 s) |
| Test Area | 10.00 ±0.05 cm² |
| Timing Accuracy | ≤±1 s over 1000 s |
| Vacuum Chamber Volume | Large chamber: 380 ±1 mL |
| Small chamber | 38 ±1 mL |
| Vacuum Setpoint Range | Range I & II: 50.66–48.00 kPa |
| Range III | 50.66–29.33 kPa |
| Air Ingress Volume | 10.00 ±0.20 mL (large chamber), 1.00 ±0.05 mL (small chamber) for pressure drop from 50.66 kPa to 48.00 kPa |
| Applied Pressure | 100 kPa ±2 kPa |
| Display | 7-inch color TFT touch screen with bilingual (Chinese/English) menu interface |
| Operating Environment | 5–35 °C, RH ≤85% |
| Dimensions | 318 × 362 × 518 mm |
| Weight | 47 kg |
| Compliance | GB/T 456, ISO 8791-2, TAPPI T479, ASTM D5263 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | DRK 108 |
| Measurement Principle | Elmendorf pendulum tear method (ISO 1974, GB/T 455.1) |
| Standard Pendulum Range | (10–13,000) mN |
| Resolution | 10 mN |
| Accuracy | ±1% FS (20–80% of full scale), ±0.5% FS (outside range) |
| Repeatability | <1% FS (20–80% FS), <0.5% FS (outside range) |
| Tear Arm Length | (104 ± 1) mm |
| Initial Tear Angle | 27.5° ± 0.5° |
| Tear Distance | (43 ± 0.5) mm |
| Clamp Face Dimensions | 25 × 15 mm |
| Clamp Spacing | (2.8 ± 0.3) mm |
| Specimen Size | (63 ± 0.5) mm × (50 ± 2) mm |
| Operating Environment | 20 ± 10 °C, RH ≤ 80% |
| Power Supply | AC 220 V ± 5%, 50 Hz |
| Dimensions | 460 × 400 × 400 mm |
| Weight | 30 kg |
| Compliance | ISO 1974, GB/T 455.1, GB/T 450–2002, GB/T 10739–2002 |
| Data Acquisition | 24-bit high-precision ADC (1/10,000,000 resolution), integrated precision load cell |
| Output | Built-in thermal printer (bilingual Chinese/English interface), statistical reporting (mean, SD, CV) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK |
| Price | USD 7,000 (FOB) |
| Vacuum Range | 0–100 kPa |
| Detection Sensitivity | 1–3 µm |
| Test Duration | ~30 s per sample |
| Operating Pressure | Ambient |
| Vacuum Source | External Vacuum Pump |
| Compliance | ASTM F2338-09, USP <1207> |
| Sample Compatibility | Vials, Ampoules, Prefilled Syringes |
| Data Security | Four-Tier User Authentication |
| Data Export | Immutable PDF & Local SQL Database |
| Interface | RS-232, Firmware OTA Upgrade Capability |
| Dimensions (L×W×H) | 550 × 330 × 320 mm |
| Weight | 20 kg |
| Operating Temperature | 20–30 °C |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK-1000A |
| Price | USD 7,000 (approx.) |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 250 W |
| Test Specimen Size | 75 mm × 75 mm |
| Clamp Torque | 13.6 N·m |
| Pressurized Area | 28.27 cm² |
| Negative Pressure Range | −50 to −200 Pa |
| HEPA Filtration Efficiency | >99.99% |
| Cabinet Airflow Volume | ≥5 m³/min |
| Data Storage Capacity | 5,000 test records |
| Dimensions (Main Unit) | 1180 mm (L) × 650 mm (W) × 1300 mm (H) |
| Adjustable Stand Height Range | ±100 mm from 600 mm base |
| Net Weight | ~150 kg |
| Compliance | ASTM F1670-1995, ASTM F1671-1996, ISO 16603:2004, ISO 16604:2004 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK-104 |
| Price | USD 4,200 (FOB) |
| Standard Compliance | ISO 3036, GB/T 2679.7–2005 |
| Measurement Unit | Joules (J) |
| Display | LCD with Chinese GUI |
| Output | Thermal line printer |
| Control System | Microprocessor-based embedded control |
| Sample Clamping | Spring-loaded dual-plate pneumatic-free mechanical clamp |
| Safety Mechanism | Interlocked release handle with automatic reset |
| Energy Range | 0.1–10 J (typical for corrugated board testing) |
| Resolution | 0.01 J |
| Repeatability | ≤±1.5% RSD (per ISO 3036 verification protocol) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK-108 |
| Measurement Range | (10–13,000) mN |
| Resolution | 10 mN |
| Accuracy | ±1% FS (20–80% of full scale), ±0.5% FS (outside range) |
| Repeatability | <1% FS (20–80% FS), <0.5% FS (outside range) |
| Tear Arm Length | (104 ± 1) mm |
| Initial Tear Angle | 27.5° ± 0.5° |
| Tear Distance | (43 ± 0.5) mm |
| Clamp Face Dimensions | 25 × 15 mm |
| Clamp Spacing | (2.8 ± 0.3) mm |
| Specimen Size | (63 ± 0.5) mm × (50 ± 2) mm |
| Operating Temperature | 20 ± 10 °C |
| Relative Humidity | ≤80% RH |
| Dimensions | 460 × 400 × 400 mm |
| Weight | 30 kg |
| Power Supply | AC 220 V ± 5%, 50 Hz |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK-109C |
| Measurement Range | 50–6000 kPa |
| Clamp Force (Upper/Lower Platen) | >690 kPa |
| Hydraulic Oil Delivery Rate | 170 ± 15 mL/min |
| Diaphragm Resistance | 170–220 kPa at 10 mm dome height |
| Accuracy Class | Class 1 (Resolution: 0.1 kPa) |
| Indication Accuracy | ±0.5% F.S. |
| Hydraulic Seal Integrity | Pressure drop <10% of Pₘₐₓ after 1 min at maximum test pressure |
| Clamp Ring Diameter | φ31.5 ± 0.05 mm |
| Dimensions (L×W×H) | 530 × 360 × 550 mm |
| Motor Power | 90 W |
| Power Supply | AC 220 V ± 5%, 50 Hz |
| Weight | 75 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DRK-AS601 |
| Price | USD 7,000 (FOB Qingdao) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | DRK- |
| Price | USD 7,000 (FOB Qingdao) |
| Vacuum Range | 0–100 kPa |
| Detection Sensitivity | 1–3 µm equivalent leak rate |
| Test Duration | ≤30 s per sample |
| Operating Pressure | Ambient (atmospheric) during loading |
| Vacuum Source | External vacuum pump (required, not included) |
| Test Chamber | Custom-engineered per package geometry (e.g., vials, ampoules, pre-filled syringes) |
| Principle | Vacuum decay integrity testing per ASTM F2338-09 and USP <1207> |
| Compliance | Fully aligned with ASTM F2338-09, USP <1207>, ISO 15378:2017 (for pharmaceutical primary packaging), and FDA 21 CFR Part 11 data integrity requirements |
| Dimensions (L×W×H) | 550 × 330 × 320 mm |
| Weight | 20 kg |
| Ambient Operating Temperature | 20–30 °C |
| Data Output | Local database (immutable SQLite), PDF export, RS232 interface, thermal printer support |
| Security | Four-tier role-based access control (RBAC) with unique user credentials and audit trail logging |
| Software | Embedded real-time analysis engine with automatic pass/fail classification, statistical process reporting, and GLP/GMP-compliant electronic records |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DRK-L |
| Price | USD 35,000 (FOB) |
| Vacuum Range | 0–100 kPa |
| Detection Sensitivity | 1–3 µm |
| Test Duration | ≤30 s per sample |
| Operating Environment | 20–30 °C |
| Compliance | ASTM F2338-09, USP <1207> |
| Dimensions (L×W×H) | 550 × 330 × 320 mm |
| Weight | 20 kg |
| Control Interface | Touchscreen LCD with HMI |
| Vacuum Source | External vacuum pump |
| Data Output | Built-in thermal printer, RS232 port, non-erasable local database |
| Security | Four-tier user permission system with unique login credentials |
| Software Features | Audit trail, electronic signature support, CFR Part 11–compliant data handling, automatic statistical reporting, PDF export capability |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DRK-PFI11 |
| Drum Diameter | 250 mm |
| Rotor Outer Diameter | 200 mm |
| Rotor Height | 50 mm |
| Blade Thickness | 5 mm |
| Rotor Motor Power | 1.1 kW / 380 V |
| Beater Gap Adjustment Range | 0–25 mm |
| Slurry Tank Motor | 370 W / 380 V |
| Counter Range | 0–999,999 revolutions |
| Slurry Consistency | 5–50% (w/w) |
| Oven-Dry Fiber Mass per Run | 5–30 g (standard: 10 g) |
| Standard Beating Pressures | 3.33 ± 0.1 N/mm, 1.77 ± 0.1 N/mm, and 4.89 ± 0.1 N/mm (per mm blade length) |
| Dimensions (L×W×H) | 860 × 450 × 1100 mm |
| Net Weight | 251 kg |
| Gross Weight | 310 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | DRK-pHS-5 Series |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| Display | 7-inch TFT Color Touchscreen |
| Measurement Range | pH –2.000 to 20.000 |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Accuracy | ±0.002 pH / ±0.02 %FS mV / ±0.2 °C |
| Stability | (±0.002 pH ±1 digit)/3 h |
| Calibration | Auto 1–5-point with JJG 119 buffer recognition and custom buffer support |
| Temperature Compensation | Automatic or manual (–5.0 to 110.0 °C) |
| Electrode Interface | BNC + RCA + Terminal Block |
| Data Storage | 500 entries (user-isolated) |
| Connectivity | USB + RS232 |
| Compliance | GLP-compliant reporting with audit-ready print logs |
| Power | DC 12 V, 10 W |
| Dimensions | 210 × 210 × 100 mm |
| Weight | 2 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK-WL |
| Load Capacity | 500 N (customizable) |
| Force Accuracy | Better than Class 1 |
| Force Resolution | 0.1 N |
| Deformation Resolution | 0.001 mm |
| Test Speed | 1–500 mm/min (stepless adjustment) |
| Standard Specimen Width | 15 mm |
| Crosshead Travel | 500 mm (customizable) |
| Power Supply | AC 220 V ±5%, 50/60 Hz |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | DRK-WL101 |
| Max Load Capacity | 30 N (customizable) |
| Force Resolution | 0.1 N |
| Deformation Resolution | 0.001 mm |
| Test Speed Range | 1–500 mm/min (infinitely variable) |
| Standard Specimen Width | 15 mm |
| Gauge Length Travel | 300 mm (customizable) |
| Accuracy Class | Better than Grade 1 |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | GB 8808, GB/T 4850, ASTM D882, ISO 527-2, ASTM D3330, ASTM F88, QB/T 2358 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | DRK100 |
| Motor Power | 1.7 kW |
| Max Load Capacity | 100 kg |
| Table Surface Dimensions | 1100 × 1000 mm |
| Table Motion | Reciprocating (Rotary Oscillation) |
| Frequency Range | 1–300 rpm (≈0.017–5 Hz) |
| Peak-to-Peak Amplitude | 25.4 mm (Fixed) |
| Operating Time Range | 0–9999 h/min/sec |
| Control Modes | Sine, Sweep, Programmable, Logarithmic, Octave, Acceleration-Controlled, Amplitude-Controlled, Time-Controlled |
| Drive Motor | 1 HP (10-pole) |
| Input Voltage | 220 ±10% V AC |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | DRK 101 |
| Force Capacity Options | 100 N / 500 N / 1000 N / 5000 N |
| Accuracy Class | Better than 0.5 |
| Force Resolution | 0.1 N |
| Deformation Resolution | 0.001 mm |
| Test Speed Range | 1–1000 mm/min (infinitely variable) |
| Standard Grip Width | 30 mm |
| Optional Grip Width | 50 mm |
| Maximum Travel | 1000 mm (customizable) |
| Dimensions (L×W×H) | 500 × 300 × 1700 mm |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DRK101 |
| Power Supply | AC 220 V ±10%, 50 Hz, 5 A |
| Measurement Range | 0–30 N |
| Test Accuracy | ±0.01 N |
| Resolution | 0.01 N |
| Ball Diameter | φ16 mm |
| Inner Ring Diameter | φ50 mm (optional φ89 mm) |
| Clamp Width | ≥12.5 mm |
| Penetration Depth | 25 mm |
| Standard Test Speed | 125 ±5 mm/min |
| Adjustable Speed Range | 1–400 mm/min |
| Display | Color TFT Touchscreen LCD |
| Interface | RS232 Serial Port |
| Compliance | ISO/FDIS 12625-9:2015, GB/T 24328.7, GB/T 20810-2018 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK101A |
| Load Capacity Options | 100 N / 500 N / 1000 N / 5000 N |
| Accuracy Class | Better than 0.5 |
| Elongation Resolution | 0.001 mm |
| Test Speed Range | 1–500 mm/min (infinitely variable) |
| Standard Grip Width | 30 mm |
| Optional Grip Width | 50 mm |
| Maximum Travel | 400 mm (customizable) |
| Dimensions (L×W×H) | 500 × 300 × 1150 mm |
| Weight | 73 kg |
| Power Supply | AC 220 V, 50 Hz |
| Standard Configuration | Mainframe, Control Unit, Power Cable, Data Cable, 4 Rolls Thermal Paper |
| Optional | PC-Based Control System |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK101A |
| Load Capacity Options | 100 N / 200 N / 500 N / 1000 N / 5000 N |
| Accuracy | Better than Class 0.5 |
| Deformation Resolution | 0.001 mm |
| Test Speed Range | 1–500 mm/min (infinitely variable) |
| Standard Specimen Width | 30 mm (50 mm optional) |
| Gauge Length | 400 mm (customizable) |
| Dimensions (L×W×H) | 500 × 300 × 1150 mm |
| Weight | 73 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK103A |
| Price | USD 7,000 (FOB) |
| Illumination Geometry | d/0 (ISO 2469) |
| Integrating Sphere Diameter | φ150 mm |
| R₄₅₇ Optical System | Peak Wavelength 457 nm, FWHM 44 nm |
| RY Optical System | Compliant with GB/T 3979–1983 |
| Zero Drift | ≤0.1 |
| Indication Drift | ≤0.1 |
| Indication Error | ≤0.5 |
| Repeatability Error | ≤0.1 |
| Specular Reflection Error | ≤0.1 |
| Sample Aperture | ≥φ30 mm or ≥φ19 mm |
| Max Sample Thickness | 40 mm |
| Power Supply | 220 V ±10%, 50 Hz, 0.3 A |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions (L×W×H) | 345×260×425 mm |
| Net Weight | 11 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DRK104 |
| Price | Upon Request |
| Measurement Range | 0–48 J (4 ranges: A: 0–6 J, B: 0–12 J, C: 0–24 J, D: 0–48 J) |
| Accuracy (20–80% of full scale per range) | ±0.05 J (A), ±0.10 J (B), ±0.20 J (C), ±0.50 J (D) |
| Friction Loss | ≤0.25 J |
| Punching Probe Geometry | Equilateral triangular pyramid |
| Dimensions (L×W×H) | 800 × 470 × 840 mm |
| Net Weight | 145 kg |
| Operating Environment | 5–35 °C, RH ≤85% |
| Pendulum Swing Frequency | >120 cycles/min |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK104 |
| Measurement Range | 0–48 J (4 ranges: 0–6 J, 0–12 J, 0–24 J, 0–48 J) |
| Accuracy | ±0.05 J (A range), ±0.10 J (B), ±0.20 J (C), ±0.50 J (D) |
| Cone Geometry | Equilateral triangular pyramid |
| Friction Loss | ≤ 0.25 J |
| Swing Arm Frequency | >120 cycles/min |
| Dimensions (L×W×H) | 800 × 470 × 840 mm |
| Net Weight | 145 kg |
| Operating Environment | 5–35 °C, RH ≤ 85 % |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK104A |
| Price | USD 7,000 (FOB Qingdao) |
| Measurement Range | 0–48 J (4 ranges) |
| Accuracy | ±0.05 J to ±0.50 J per range |
| Friction Loss | ≤0.25 J |
| Pyramid Probe | Equilateral triangular base (60 mm × 60 mm × 60 mm), height (25 ± 0.7) mm, edge radius R (1.5 ± 0.1) mm |
| Dimensions (L×W×H) | 800 × 470 × 840 mm |
| Weight | 145 kg |
| Operating Environment | 5–35 °C, RH ≤85% |
| Standards Compliance | ISO 3036, GB/T 2679.7 |