| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK132 |
| Speed Options | 1400 rpm or 1800 rpm (customizable) |
| Drum Dimensions | Ø145 mm × 90 mm height |
| Overall Dimensions | Ø300 mm × 340 mm height |
| Power Supply | AC 220 V, 50 Hz |
| Application | Laboratory-scale pulp dewatering, consistency measurement, and pre-screening sample preparation in papermaking R&D |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DRK 133 |
| Price | USD 5,700 (FOB Qingdao) |
| Heat Seal Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Seal Time Range | 0.1–999.9 s |
| Seal Pressure Range | 0.05–0.7 MPa |
| Seal Area | 40 mm × 10 mm (five-point configuration, customizable) |
| Heating Method | Dual-zone independent resistive heating with aluminum-filled uniform-heating tubes |
| Pneumatic Supply Requirement | 0.5–0.7 MPa (user-supplied air source) |
| Air Inlet Fitting | Ø8 mm polyurethane tubing |
| Dimensions (L×W×H) | 550 mm × 340 mm × 470 mm |
| Power Supply | AC 220 V, 50 Hz |
| Interface | RS232 serial port |
| Safety Features | Anti-scald thermal shielding, dual-mode activation (manual button + foot switch), synchronized pneumatic cylinder actuation |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK133 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±1 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–0.7 MPa |
| Sealing Surface Dimensions | 180 mm × 10 mm (customizable) |
| Heating Method | Dual-zone resistive heating with aluminum-encapsulated heating elements |
| Pneumatic Supply Requirement | 0.5–0.7 MPa via Ø8 mm polyurethane tubing |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Dimensions (L×W×H) | 400 mm × 280 mm × 380 mm |
| Weight | Approx. 40 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK133 |
| Heat Seal Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±1 °C |
| Seal Time Range | 0.1–999.9 s |
| Seal Pressure Range | 0.05–0.7 MPa |
| Seal Jaw Dimensions | 180 mm × 10 mm (customizable) |
| Pneumatic Actuation (Air Supply Required | 0.5–0.7 MPa, Ø8 mm PU Tube) |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Dimensions | 400 × 280 × 380 mm (L×W×H) |
| Weight | ~40 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DRK 134 |
| Vacuum Range | 0 to –90 kPa |
| Vacuum Chamber Dimensions (Std.) | Φ270 mm × 210 mm (H) |
| Accuracy Class | Class 1 |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Net Weight | ~12 kg |
| Air Source Requirement | 0.7 MPa, Φ8 mm polyurethane tubing interface |
| Overall Dimensions | 300 mm (L) × 380 mm (B) × 450 mm (H) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | DRK134 |
| Price | USD 7,000 (FOB Qingdao) |
| Accuracy Class | Class 1 |
| Vacuum Range | 0 to –90 kPa |
| Vacuum Chamber Dimensions (Standard) | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Pressure | 0.7 MPa (user-provided) |
| Air Inlet Fitting | Φ6 mm polyurethane tubing |
| Overall Dimensions | 300 mm (L) × 380 mm (W) × 450 mm (H) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 12 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | DRK134 |
| Vacuum Range | 0 to –90 kPa |
| Vacuum Chamber Dimensions (Standard) | Φ270 mm × 210 mm (H) |
| Optional Chambers | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Pressure | 0.7 MPa (user-supplied) |
| Air Inlet Fitting | Φ8 mm Polyurethane Tubing |
| Overall Dimensions | 300 mm (L) × 380 mm (B) × 450 mm (H) |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Net Weight | ~12 kg |
| Accuracy Class | Class 1 |
| Compliant Standards | GB/T 15171, ASTM D3078 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK135 |
| Test Methods | ASTM D1709 A-Method, GB/T 9639-2008 A-Method, ISO 7765-1:1994 A-Method |
| Dart Head Diameter | 38.1 ± 0.13 mm (ASTM), 38 ± 1 mm (GB/ISO) |
| Dart Head Material | Polished aluminum or phenolic resin (low-density, hardness-matched) |
| Drop Height | 0.66 ± 0.01 m |
| Mass Range (A-Method) | 50–2000 g |
| Energy Resolution | 0.1 J |
| Mass Resolution | 0.1 g |
| Specimen Clamping | Pneumatic |
| Specimen Size | ≥150 mm × 150 mm |
| Power Supply | AC 220 V ± 5%, 50 Hz |
| Net Weight | ~65 kg |
| Compliance | ASTM D1709, GB/T 9639-2008, ISO 7765-1, JIS K7124 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK137 |
| Power Supply | AC 220 V, 50 Hz (Grounding Required) |
| Operating Temperature Range | 101–135 °C (Steam Mode), ≤100 °C (Water-Boiling Mode) |
| Retort Chamber Volume | 50 L (Standard |
| Steam Pressure Limit | 0.25 MPa (Auto-Relief at Threshold) |
| Cooling Method | Compressed Air + Water Quench (≤3 min to 30–40 °C) |
| Water Supply Pressure | 0.15–0.25 MPa |
| Air Supply Pressure | 0.25 MPa (Stable) |
| Timer Range | 0–99 min |
| Relative Humidity Limit | ≤80 % RH |
| Safety Features | Dual Safety Valves, Overtemperature Cutoff at 140 °C, Overpressure Relief, Low-Water Level Detection, Leakage Protection, Heater Overload Protection, Audible End-of-Cycle Alert |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK140 |
| Power Supply | 220/240 VAC @ 50 Hz or 110 VAC @ 60 Hz |
| Drop Height Range | Adjustable up to 2,500 mm (max) |
| Test Specimen Clamp Size | 270 mm × 270 mm |
| Base Plate | Solid Steel, 880 mm × 550 mm |
| Impact Sphere | 324 g ± 5.0 g, Ø 42.8 mm ± 0.2 mm |
| Release Mechanism | Electromagnetic Solenoid |
| Actuation | Foot Switch |
| Compliance | ISO 4586-2, EN 438-2:2005, AS/NZS 4266.27 (optional test module) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK150 |
| Price | USD 7,000 (Reference FOB Qingdao) |
| Key | Brand: Drick |
|---|---|
| Model | DRK155 |
| Type | Disposable & Refillable |
| Drying Time | <3 sec |
| Standard Dyne Levels | 38–50 mN/m (in 2 mN/m increments) |
| Ink Volume per Bottle | 100 mL |
| Compliance | ASTM D2578, ISO 8296, GB/T 14216 |
| Origin | Shandong, China |
| Manufacturer | Drick Instrument Co., Ltd. |
| Packaging Industry Application | Film Surface Energy Verification for Printing, Lamination & Metallization |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DRK162 |
| Price | USD 7,000 (FOB Qingdao) |
| Standard Compliance | ASTM F392 |
| Tumbling Frequency | 45 cycles/min |
| Tumbling Angle | 440° or 400° |
| Horizontal Stroke | 155 mm or 80 mm |
| Sample Thickness Limit | ≤2.5 mm (custom fixtures available for thicker specimens) |
| Sample Dimensions | 280 mm × 200 mm |
| Number of Stations | 4 |
| Sample Capacity | 1–4 specimens per test |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Net Weight | 110 kg |
| Host Dimensions | 800 mm (L) × 450 mm (W) × 605 mm (H) |
| Control System | Microprocessor-based with LCD interface and PVC membrane keypad |
| Safety Features | Dual hardware/software interlocks + automatic reset function |
| Optional Accessories | Sample cutter, stainless-steel hose clamps (91–114 mm) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | DRK162 |
| Price | Upon Request |
| Rub Frequency | 45 cycles/min |
| Max Sample Thickness | ≤2.5 mm (custom fixtures available for thicker specimens) |
| Rub Angle | 440° or 400° |
| Horizontal Stroke | 155 mm or 80 mm |
| Test Stations | 4 |
| Sample Quantity | 1–4 specimens per test |
| Sample Dimensions | 280 mm × 200 mm |
| Unit Dimensions | 800 mm (L) × 450 mm (W) × 605 mm (H) |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Net Weight | 110 kg |
| Compliance Standard | ASTM F392 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DRK166 |
| Price | ¥50,000 CNY |
| Force Range | 0.2–30 N |
| Force Accuracy | ±0.2% FS |
| Displacement Range | 0.125–45 mm |
| Displacement Accuracy | ±0.125 mm |
| Temperature Range | Ambient to 210 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Chamber Dimensions | 700 × 400 × 390 mm |
| Specimen Size | 150 mm × 15 mm |
| Test Stations | 1–3 simultaneous |
| Compliance | ISO 14616 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DRK182A |
| Impact Angle | 90° |
| Specimen Sets per Test | 5 |
| Energy Capacity | 0.25 / 0.5 kg·cm |
| Minimum Resolution | 0.005 kg·cm |
| Dimensions (W×D×H) | 70 × 34 × 60 cm |
| Weight | 91 kg |
| Compliance | GB/T 26203, TAPPI UM-403, TAPPI T 569 pm-00 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | DRK182B |
| Impact Angle | 90° |
| Sample Sets per Test | 5 |
| Energy Capacity | 0.25 / 0.5 kg·cm |
| Minimum Resolution | 0.005 kg·cm |
| Dimensions (W×D×H) | 70 × 34 × 60 cm |
| Weight | 91 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK203A |
| Measurement Range | 0–1 mm |
| Resolution | 0.001 mm |
| Measuring Force | 0.1–1.0 N (configurable per probe geometry) |
| Compliance | GB/T 6672–2001, ISO 4593:1993 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK203B |
| Measurement Range | 0–1 mm |
| Resolution | 0.001 mm |
| Measuring Force | 0.1–1.0 N (configurable per probe geometry) |
| Probe Configurations | Flat upper probe (Ø6 mm) + flat lower anvil |
| Compliance | GB/T 6672–2001 (equivalent to ISO 4593:1993) |
| Standard Accessories | Main unit, Certificate of Conformance |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK203C |
| Measurement Range | 0–3 mm |
| Resolution | 0.1 µm |
| Accuracy Class | Class 1 (per GB/T 6672) |
| Measurement Speed | 5 tests/min (adjustable) |
| Probe Traverse Speed | 3 mm/s (adjustable) |
| Contact Area | Ø6 mm (28.3 mm², standard) |
| Compliance Standards | GB/T 6672, GB/T 451.3, GB/T 6547, ASTM D645, ASTM D374, ASTM D1777 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | DRK219 |
| Standard Torque Range | 20 N·m (40 N·m and 50 N·m optional) |
| Accuracy Class | Class 1 |
| System Resolution | 0.001 N·m |
| Clamp Diameter Range | Φ5 mm – Φ170 mm |
| Dimensions (L×W×H) | 350 mm × 240 mm × 140 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 19 kg |
| Compliance Standards | GB/T 17876, BB/T 0025, BB/T 0034 (GB/T 14803), ASTM D 2063, ASTM D 3198, ASTM D 3474 |
| Standard Configuration | Main Unit + Thermal Mini-Printer |
| Optional Accessories | PC-based Data Management Software, RS-232 Communication Cable |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DRK219B |
| Price | USD 7,000 (FOB Qingdao) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DRK255 |
| Thermal Resistance Range | 0–2000 × 10⁻³ m²·K/W |
| Repeatability Error (Thermal) | < ±2.5% (factory-controlled to ±2.0%) |
| Resolution (Thermal) | 0.1 × 10⁻³ m²·K/W |
| Moisture Resistance Range | 0–700 m²·Pa/W |
| Repeatability Error (Moisture) | < ±2.5% (factory-controlled to ±2.0%) |
| Test Plate Temperature Range | 20–40 °C |
| Air Velocity over Specimen | 1 m/s (adjustable) |
| Platform Vertical Travel (Specimen Thickness) | 0–70 mm |
| Test Duration Setting | 0–9999 s |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Display Resolution | 0.1 °C |
| Preheating Cycle | 6–99 min |
| Specimen Size | 350 mm × 350 mm |
| Test Plate Size | 200 mm × 200 mm |
| Dimensions (L×W×H) | 1050 mm × 1950 mm × 850 mm |
| Power Supply | AC 220 V ±10%, 3300 W, 50 Hz |
| Environmental Operating Range | 10–30 °C, 30–80% RH |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DRK261 |
| Price | USD 7,000 (FOB Qingdao) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DRK268 |
| Price | Upon Request |
| Frequency | 45 cycles/min |
| Stroke Options | 155 mm / 80 mm |
| Twist Angles | 440° / 400° |
| Cycle Count Range | 20–2700 cycles |
| LCD Display Lifespan | ~100,000 hours |
| Touchscreen Durability | ~50,000 actuations |
| Compliance Standard | ASTM F392 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DRK310 |
| Price Range | USD 28,000 – 42,500 |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂, and other non-toxic gases |
| Measurement Range | 0.1–50,000 cm³/(m²·day·0.1 MPa) |
| Test Error | ±0.01 cm³/(m²·day·0.1 MPa) |
| Vacuum Accuracy | ±0.1 Pa |
| Vacuum Range | 0–1333.3 Pa |
| Ultimate Vacuum | <20 Pa |
| Vacuum Attainment Time | ≤20 min to <27 Pa |
| Temperature Control Range | 15–50 °C |
| Temperature Stability | ±0.1 °C |
| Sample Thickness Limit | ≤3 mm |
| Test Area | 45.34 cm² (circular) |
| Test Pressure Differential | 0.05–0.15 MPa |
| Gas Inlet Port | Ø6 mm |
| Supply Pressure | 0.5–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | <1500 W |
| Dimensions (L×W×H) | 680×380×270 mm |
| Weight | 50 kg |
| Calibration | Certified Standard Film |
| Compliance | YBB 00082003, GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DRK310 |
| Quotation | Upon Request |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DRK 310 |
| Pricing | Upon Request |
| Measurement Range | 0.005–10,000 cm³/m²·day·0.1 MPa |
| Measurement Uncertainty | ±0.005 cm³/m²·day·0.1 MPa |
| Specimen Quantity | 3 independent test chambers |
| Vacuum Sensor Count | 1 |
| Vacuum Accuracy | ±0.1 Pa |
| Vacuum Range | 0–1333 Pa |
| Ultimate Vacuum Level | <20 Pa |
| Vacuum Pumping Time | ≤10 min to <27 Pa |
| Max. Specimen Thickness | ≤3 mm |
| Test Area per Chamber | 45.34 cm² (circular) |
| Calibration Method | Certified Reference Film |
| Compatible Test Gases | O₂, N₂, CO₂, and other non-corrosive or low-toxicity gases |
| Test Pressure Range | 0.005–0.15 MPa |
| Gas Inlet Port | Ø6 mm |
| Supply Gas Pressure | 0.5–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | <1500 W |
| Dimensions (L×W×H) | 680 × 380 × 270 mm |
| Net Weight | 60 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DRK310 |
| Measurement Range | 0.01–55,000 cm³/m²·24h·0.1 MPa |
| Sample Capacity | 3 independent test chambers |
| Vacuum Resolution | 0.1 Pa |
| Vacuum Range | 0–1333 Pa |
| Ultimate Vacuum | <10 Pa |
| Test Gas | O₂, N₂, CO₂ |
| Test Pressure Differential | 0–0.15 MPa |
| Temperature Range | 15–50 °C |
| Temperature Control Accuracy | ±0.05 °C |
| Power Supply | AC 220 V, 50 Hz, <1500 W |
| Net Weight | 65 kg |
| Dimensions (L×W×H) | 680 × 380 × 280 mm |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | DRK311 |
| Price | USD 7,000 (FOB Qingdao) |
| Measurement Principle | Constant-Volume/Variable-Pressure (Manometric) Method |
| Standards Compliance | GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂ |
| Permeation Range | 0.01–55,000 cm³/(m²·24h·0.1 MPa) |
| Vacuum Resolution | 0.1 Pa |
| Base Vacuum | <10 Pa |
| Vacuum Capacity | 0–1333 Pa |
| Temperature Range | 15–50 °C |
| Temp. Control Accuracy | ±0.05 °C |
| Test Chambers | 3 independent |
| Sample Size | Standard 97 cm² (Ø111 mm) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | <1000 W |
| Dimensions (W×D×H) | 680 × 380 × 280 mm |
| Net Weight | 65 kg |
| Gas Supply Pressure | 0.4–0.6 MPa |
| Test Pressure Range | 0–0.15 MPa |