| Brand | Paratronix |
|---|---|
| Model | PMT-CSP02 |
| Measurement Range | 1 kg / 5 kg / 25 kg / 50 kg (selectable) |
| Force Resolution | 0.001 N |
| Displacement Resolution | 0.001 mm |
| Test Speed | 1–500 mm/min (infinitely variable) |
| Speed Accuracy | ±1% (1–10 mm/min), ±0.5% (10–500 mm/min) |
| Temperature Control Range | −10 °C to +80 °C |
| Temp. Stability | ±0.1 °C |
| Clamp Force Adjustment | 0–10 N |
| Test Stroke | 1000 mm |
| Water Bath Flow Rate | 10 L/min |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Dimensions (L×W×H) | 480 × 560 × 1430 mm |
| Weight | ~90 kg |
| Compliance | YY/T 1536–2017, T/CAMDI 021–2019 |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PT-01 |
| Measurement Range | 0–99,999 folds |
| Folding Angle | 0°–142° continuously adjustable |
| Folding Speed | 10–200 folds/min, stepless adjustment |
| Spring Tension | 4.91–14.72 N (9.81 N preload compresses spring ≥17 mm) |
| Tension Stability | Imported tension assembly |
| Tension Variation Due to Eccentric Rotation | ≤0.343 N |
| Folding Jaw Width | 19 ±1 mm |
| Crease Radius | 0.38 ±0.02 mm |
| Specimen Length | ≥140 mm |
| Temperature Drift at Crease | ≤1 °C after 4 h |
| Jaw Spacing | 9.5 mm |
| Lower Jaw Clamping | Knurled cylindrical knob for ergonomic, high-grip clamping |
| Crease Gap Options | 0.25 / 0.5 / 0.75 / 1.00 mm (user-selectable) |
| HMI | 5-inch LCD display with real-time data visualization |
| Output | Integrated thermal printer module |
| Operating Environment | 0–35 °C, RH <85% |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PT-02 |
| Compliance | GB/T 451.3 |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | PTT-03A |
| Measurement Range | 0–2 mm (standard), optional 0–6 mm / 0–12 mm |
| Resolution | 0.1 µm (1 µm optional) |
| Test Speed | 1–25 tests/min |
| Measuring Head Parallelism | ±0.2 µm (mechanically adjustable, verified with gauge blocks) |
| Accuracy | ±<0.3 µm |
| Contact Pressure | 17.5 ± 1 kPa (for films), 50 ± 1 kPa (for paper), customizable for other materials |
| Contact Geometry | Spherical probe |
| Power Supply | AC 220 V, 50 Hz / AC 120 V, 60 Hz |
| Dimensions (L×W×H) | 300 × 400 × 435 mm |
| Net Weight | ~30 kg |
| Compliance Standards | GB/T 6672, GB/T 451.3, GB/T 6547, ASTM D645, ASTM D374, ASTM D1777, TAPPI T411, ISO 4593, ISO 534, ISO 3034, DIN 53105, DIN 53353, JIS K6250, JIS K6328, JIS K6783, JIS Z1702, BS 3983, BS 4817, ASTM D6988, ASTM F2251, BS 2782-6, DIN 53370, ISO 9073-2, ISO 12625-3, ISO 5084, ASTM D3652, GB/T 24218.2, FEFCO No. 3, EN 1942 |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCT-A6 |
| Test Stations | 6 |
| Pressure Range | 0.1–0.7 MPa |
| Test Duration | 1.0–999999.9 s |
| Touchscreen | 7-inch capacitive HMI |
| Air Supply Requirement | 0.7–0.8 MPa (user-provided) |
| Air Interface | Φ8 mm polyurethane tubing |
| Dimensions (L×W×H) | 660 × 200 × 372 mm |
| Standard Accessories | Main unit, 8 pcs tempered glass plates, 1 air hose, 1 power cord |
| Brand | Paratronix |
|---|---|
| Model | WVTR-C6 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Principle | Gravimetric Cup Method (Weight Change over Time) |
| Measurement Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 6 independent stations |
| Resolution | 0.0001 g |
| Accuracy | ±0.01 g/m²·24h |
| Temperature Control Range | 15–55°C (standard) |
| Temp. Stability | ±0.1°C |
| Humidity Control Range | 10–90% RH (standard 90% RH) |
| RH Stability | ±1% RH |
| Airflow Velocity | 0.5–2.5 m/s (customizable) |
| Max. Sample Thickness | ≤3 mm (customizable) |
| Test Area | 33 cm² |
| Sample Diameter | Φ74 mm |
| Test Modes | Desiccant Method (Standard), Moisture Gain Method (Optional), Dual-Mode (Optional) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 660 × 480 × 525 mm |
| Net Weight | 70 kg |
| Gas Supply Pressure | 0.6 MPa |
| Tubing Interface | Φ6 mm polyurethane tube |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | WVTR-C6 |
| Price | USD 9,500 (FOB) |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 620 (FOB) |
| Measurement Range | 0–100 kg/cm² (0.1 kg/cm² resolution) |
| Hydraulic Oil Displacement Rate | 170 ± 15 mL/min |
| Display Units | kg, N, lb |
| Dimensions (W×D×H) | 450 × 430 × 520 mm |
| Sensor Accuracy | ±1 kPa |
| Compliance | ASTM D774, ISO 2758, TAPPI T403, GB/T 454 |
| Brand | QINGTAO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | QT-KY01 |
| Max Test Load | 2000 kgf |
| Accuracy Class | Class 1 (per GB/T 16491 / ISO 7500-1) |
| Force Measurement Range | 0.4–100% FS |
| Force Accuracy | ±1% of reading |
| Force Resolution | 1/200,000 |
| Displacement Accuracy | ±1% of reading |
| Displacement Resolution | 0.05 mm |
| Test Speed Range | 10–300 mm/min |
| Speed Accuracy | ±1% of set value |
| Test Chamber Dimensions (optional) | 600×600×600 mm, 800×800×800 mm, 1000×1000×1000 mm, 1200×1200×1200 mm, or 1500×1500×1500 mm |
| Control System | Embedded microcomputer with optional industrial touchscreen interface |
| Drive System | Gearmotor + frequency inverter |
| Motor Power | 0.75 kW |
| Compliance Standards | ISO 2872, ISO 2874, TAPPI T 804, JIS Z 0212, NF H3 001, CNS 2236 / 3511, QB/T 1048 |
| Brand | QKTester |
|---|---|
| Model | COFT_02 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | GB 10006–1988, ISO 8295, ASTM D1894 |
| Test Modes | Static & Kinetic CoF |
| Load Range | 0–50 N (typical) |
| Speed Range | 10–300 mm/min |
| Force Resolution | ≤0.01 N |
| Sample Stage | Horizontal Dual-Surface Fixture |
| Data Output | Real-time force-time curve, CoF values (μs/μk), pass/fail flagging |
| Interface | 7″ TFT LCD touchscreen with embedded test protocol library |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HSPT-01 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–0.7 MPa |
| Sealing Jaw Dimensions | 150 mm × 10 mm (customizable) |
| Heating Mode | Single- or Dual-Side Heating |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Compliant Standards | QB/T 2358, ASTM F2029, YBB 00122003 |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | OGT-01 |
| Price | USD 145 (FOB) |
| Measured Gases | O₂, CO₂ |
| Measurement Principle | Electrochemical (O₂), Non-Dispersive Infrared (NDIR) Absorption (CO₂) |
| Sample Volume | O₂ < 3 mL |
| Resolution | 0.01% (v/v) |
| Accuracy | ±0.2% (v/v) |
| O₂ Range | 0.2–21.0% (v/v) |
| Standard Sampling Volume | ≥5 mL at 101.3 kPa |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 5.5 kg |
| Brand | QKTester |
|---|---|
| Model | OGT-01 |
| Origin | Shandong, China |
| Manufacturer | QKTester Instrument Co., Ltd. |
| Gas Measurement | O₂ (standard), CO₂ (optional) |
| Principle | Electrochemical sensor (O₂), NDIR (CO₂, optional) |
| Range | 0–100% O₂ |
| Resolution | 0.01% |
| Accuracy | ±0.2% O₂ |
| Sample Volume | <3 mL |
| Dimensions | 230 × 120 × 82 mm |
| Weight | 1 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Data Storage | 1500 records |
| Display | Backlit LCD, bilingual (English/Chinese) |
| Interface | Built-in thermal printer |
| Compliance | Designed for ISO 8573-1, USP <1207>, ASTM F2476, and GMP-aligned environmental monitoring workflows |
| Brand | QKTester |
|---|---|
| Model | OGT-02 |
| Measurement Principle | Electrochemical (O₂), NDIR Infrared Absorption (CO₂, optional) |
| Gas Types | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0–100% vol, Resolution: 0.01%, Accuracy: ±0.2% |
| CO₂ Range | 2–100% vol, Resolution: 0.01%, Accuracy: ±(0.03% + 5% of reading) |
| Sensor Lifetime | ~2 years (O₂), >15 years (CO₂) |
| Sample Volume | ≥6 mL (O₂), ≥20 mL (CO₂) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions | 350 × 310 × 220 mm |
| Weight | 3.2 kg |
| Compliance | Designed for GMP/GLP environments |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WVTR-C1 |
| Test Range | 0.1–10,000 g/m²·24h |
| Test Accuracy | 0.01 g/m²·24h |
| Temperature Range | 10°C–55°C (±0.1°C to ±0.5°C) |
| Humidity Range | 10%RH–90%RH (±1%RH to ±2%RH) |
| Air Velocity | 0.5–2.5 m/s |
| Test Area | 33.18 cm² |
| Specimen Diameter | Φ72–Φ74 mm |
| Test Stations | 1–3 |
| Dimensions | 450×500×550 mm to 850×890×520 mm |
| Power Supply | AC 220 V, 50 Hz |
| Standards Compliance | GB/T 1037, GB/T 16928, ISO 2528, ASTM E96, ASTM D1653, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003-2015 |
| Brand | QuankeRida / qktester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | OGT-01 |
| Price | USD 145 (converted from ¥999 at 1:6.9) |
| Measurement Range | 0–21% O₂ (typical) |
| Accuracy | ±0.2% O₂ (full scale) |
| Sample Volume | ≥5 mL (at standard atmospheric pressure) |
| Detection Principle | Fluorescence Quenching or Electrochemical Sensing (user-selectable/configurable per unit) |
| Operation Mode | Manual probe insertion with real-time sensor response |
| Data Storage | Internal non-volatile memory (≥1,000 test records) |
| Power Supply | AC 220 V ±10% or rechargeable Li-ion battery (field-deployable) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Net Weight | 5.5 kg |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MTA-2000C |
| Pricing | Available Upon Request |
| Brand | Regmed |
|---|---|
| Origin | Brazil |
| Model | REGMED-VB-21 |
| Refining Capacity | 360 g (oven-dry basis) |
| Beater Bowl Volume | 23 L |
| Roll-to-Plate Contact Force | 105 N ± 1 N |
| Roll Speed | 500 ± 10 rpm |
| Shear Velocity | ~5 m/s |
| Working Consistency | 1.57% |
| Power Supply | 220 VAC, 50/60 Hz, 2 kW |
| Dimensions (W×L×H) | 1200 × 850 × 1100 mm |
| Weight | 450 kg |
| Compressed Air Requirement | Clean, dry air, 1.5–6.0 kgf/cm² (set at 5 kgf/cm²) |
| Materials | AISI 410 hardened stainless steel (roll: 350–400 HB |
| plate | 325–375 HB) |
| Standards Compliance | TAPPI T 200, T 205 |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BMC-B1 |
| Compliance Standards | GB/T 9639.1–2008, ISO 7765-1:1988, ASTM D1709, JIS K7124-1 |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CHY-CA |
| Measurement Principle | Mechanical Contact-Based Thickness Measurement |
| Contact Area | Standardized 10 cm² (per ISO 534 & GB/T 451.3) |
| Applied Pressure | 20 ± 0.5 kPa (adjustable per standard requirements) |
| Resolution | 0.1 µm |
| Repeatability | ≤ ±0.5 µm (at 100 µm nominal thickness) |
| Sample Size Range | ≥ 50 mm × 50 mm |
| Max Sample Thickness | 2.0 mm |
| Display | 5.7" LCD with Onboard Microcontroller Interface |
| Data Output | USB 2.0 (CSV export compatible) |
| Calibration | Traceable to NIST-traceable stainless steel reference blocks (included) |
| Compliance Standards | ISO 4593, ISO 534, ISO 3034, GB/T 6672, GB/T 451.3, GB/T 6547, ASTM D374, ASTM D1777, TAPPI T411, JIS K6250, JIS K6783, JIS Z1702, BS 3983, BS 4817 |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FIT-01 |
| Compliance | ASTM D3420, GB 8809–1988, NF T54-116 |
| Impact Energy Range | 1 J, 2 J, 3 J (standard) |
| Resolution | 0.001 J |
| Indenter Diameter Options | Ø25.4 mm, Ø19 mm, Ø12.7 mm (customizable) |
| Clamp Aperture | Ø89 mm, Ø60 mm |
| Specimen Size | 100 mm × 100 mm or Ø100 mm |
| Pneumatic Supply | 0.6 MPa (user-supplied, Ø6 mm polyurethane tubing) |
| Dimensions (L×W×H) | 600 mm × 390 mm × 600 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 64 kg |
| Control System | Microprocessor-based with LCD interface, PVC membrane keypad |
| Data Output | Integrated thermal mini-printer, RS232 serial port |
| Software Compatibility | Optional dedicated PC software with audit trail and data export (CSV, PDF) |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HST-H3 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–0.7 MPa |
| Sealing Surface Dimensions | 330 mm × 10 mm (customizable) |
| Heating Configuration | Dual-zone independent heating (single-zone optional) |
| Pneumatic Supply Requirement | 0.05–0.7 MPa via Ø6 mm polyurethane tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 305 mm × 550 mm × 421 mm |
| Net Weight | 40 kg |
| Compliance Standards | QB/T 2358, ASTM F2029, YBB 00122003 |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MCJ-01 |
| Pricing | Upon Request |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XLW-H |
| Force Capacity Options | 30 N, 100 N, 500 N, 1000 N |
| Force Accuracy | Class 0.5 |
| Force Resolution | 0.001 N |
| Displacement Accuracy | Class 0.5 |
| Displacement Resolution | 0.1 mm |
| Test Speed Range | 1–800 mm/min (infinitely variable) |
| Maximum Travel | 800 mm (optional 1000 mm) |
| Power Supply | 220 V / 50 Hz / 60 W |
| Dimensions (W×D×H) | 520 × 380 × 1400 mm |
| Net Weight | 72 kg |
| Operating Environment | 10–40 °C, 20–80 % RH |
| Compliance Standards | GB 13022, GB 8808, GB 1040, GB 4850, GB 7753, GB 7754, GB 453, GB/T 17200, GB/T 16578, GB/T 7122, GB/T 2790–2792, ASTM E4, ASTM D828, D882, D1938, D3330, F88, F904, ISO 37, JIS P8113, QB/T 2358, QB/T 1130, YBB pharmaceutical packaging standards (2002–2015 series) |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZDY-02 |
| Load Range | 0–50 N |
| Accuracy Class | 0.5 |
| Loading Speed | 10 mm/min (standard test speed) |
| Pre-travel Speed | 1–500 mm/min (infinitely adjustable) |
| Pre-travel Distance | 200 mm |
| Jaw Spacing Options | 36 mm / 60 mm |
| Power Supply | 220 V / 50 Hz / 40 W |
| Dimensions (W×D×H) | 330 × 410 × 680 mm |
| Net Weight | 27 kg |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 20–80 % RH |
| Display | Large LCD screen |
| Control Interface | PVC membrane keypad |
| Data Output | USB-connected PC software + built-in thermal micro-printer |
| Safety Features | Mechanical limit protection, automatic return-to-start, intelligent overload cutoff |
| Sensor | Imported high-stability load cell |
| Compliance | ASTM D1321 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SL-2 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | SL10 |
| Pricing | Upon Request |
| Sealing Temperature Range | Ambient to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 100 ms to 99 s |
| Time Resolution | 10 ms |
| Time Accuracy | ±1 ms |
| Time Repeatability | ±2 ms |
| Dual Load Cells (Left/Right) | Combined Capacity 362 kg (1000 lbf), Accuracy ≤0.09 kg (0.2 lbf), Repeatability ≤0.09 kg (0.2 lbf), Calibrated per ASTM E4 |
| Peel Load Cell | 11.34 kg (25 lbf) capacity, 0.1% FS accuracy, ASTM E4 calibrated |
| Seal Jaw Length Options | 50.8 mm (2 in) for hot tack or 127 mm (5 in) with auto-feed turntable |
| Jaw Width Options | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Configurations | Flat, Grooved, Custom, or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended 90 psi), integrated pressure switch |
| Dimensions (W×D×H) | 584.2 × 508 × 794 mm |
| Weight | 79.3 kg |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SRT 5800 |
| Pricing | Upon Request |
| Brand | SumSpring |
|---|---|
| Model | BLC-05 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Maximum Test Force | 30 N |
| Force Range | 2–100% FS |
| Force Resolution | 0.001 N |
| Displacement Resolution | 0.01 mm |
| Accuracy Class | Class 1 (per ISO 7500-1) |
| Speed Range | 1–500 mm/min, infinitely variable |
| Gauge Length | 180 mm ±1 mm (adjustable) |
| Sample Width | ≤50 mm |
| Dimensions (L×W×H) | 550×370×240 mm |
| Weight | 30 kg |
| Operating Temperature | 15–50 °C |
| Relative Humidity | ≤80% RH, non-condensing |
| Power Supply | 220 V, 50 Hz |
| Compliant Standards | GB/T 20808, GB/T 12914, GB/T 465.2 |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BTY-10S |
| Price | Upon Request |
| Measurable Cup Diameter | 20–150 mm |
| Measurable Cup Height | 15–120 mm |
| Force Measurement Range | 0–20 N |
| Force Resolution | 0.01 N |
| Accuracy | ±1% of full scale |
| Dimensions (L×W×H) | 560 × 270 × 350 mm |
| Weight | ≤34 kg |
| Operating Temperature | 10–35 °C |
| Power Supply | 220 V, 50 Hz |