Packaging Industry Specialized Instruments
Filter
Showing 151–180 of 188 results
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CJY-03 Glass Bottle Impact Tester |
| Price | Upon Request |
| Sample Diameter Range | φ20–160 mm |
| Sample Height Adjustment | 20–190 mm |
| Impact Energy Range | 0–2.5 N·m |
| Impact Energy Resolution | 0.01 N·m |
| Dimensions (L×W×H) | 420 × 330 × 500 mm |
| Weight | 28 kg |
| Operating Temperature | 15–50 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | AC 220 V, 50 Hz |
| Compliant Standards | GB/T 6552–1986, GB/T 6552–2015 |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | CJY-03 |
| Quotation | Upon Request |
| Sample Diameter Range | φ20–160 mm |
| Specimen Height Adjustment | 20–190 mm |
| Impact Energy Range | 0–2.5 N·m |
| Impact Energy Resolution | 0.01 N·m |
| Dimensions (L×W×H) | 420 × 330 × 500 mm |
| Weight | 28 kg |
| Operating Temperature | 15–50 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | AC 220 V, 50 Hz |
| Compliant Standards | GB/T 6552–1986, GB/T 6652–2015 |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CJY-03 |
| Quotation | Upon Request |
| Sample Diameter Range | φ20–160 mm |
| Sample Height Adjustment | 20–190 mm |
| Impact Energy Range | 0–2.5 N·m |
| Impact Energy Resolution | 0.01 N·m |
| Dimensions (L×W×H) | 420 × 330 × 500 mm |
| Weight | 28 kg |
| Operating Temperature | 15–50 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | AC 220 V, 50 Hz |
| Compliant Standards | GB/T 6552–1986, GB/T 6552–2015 |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MCJ-03 |
| Pricing | Available Upon Request |
| Standard Compliance | GB/T 7706–2008 |
| Applied Scope | Flexographic printed paper-based decorative packaging |
| Friction Load | 20 ± 0.2 N (customizable) |
| Stroke Frequency | 0–60 cycles per minute (cpm), default 43 cpm |
| Friction Area | 155 mm (L) × 50 mm (B) |
| Stroke Length | 60 mm |
| Cycle Count Range | 0–999,999 |
| Specimen Size | 230 mm (L) × 50 mm (B) |
| Dimensions (L×W×H) | 490 × 320 × 200 mm |
| Weight | 23 kg |
| Operating Temperature | 15–35 °C |
| Relative Humidity | ≤70% RH, non-condensing |
| Power Supply | 220 V AC, 50 Hz |
| Control System | Microprocessor-based with PVC membrane keypad and LCD display |
| Memory Function | Power-loss retention of test parameters |
| Friction Platform | Integrated precision-machined stainless steel stage ensuring uniform contact pressure and silent operation |
| Adjustable Speed & Cycle Count | Yes |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NPD-1000S |
| Price | Upon Request |
| Measurement Range | 40–1600 kPa |
| Resolution | 0.01 kPa |
| Accuracy | ±0.5% FS |
| Hydraulic Fluid Displacement Rate | 95 ± 5 mL/min |
| Diaphragm Resistance | 25–35 kPa |
| Diaphragm Bulge Height | 9 mm |
| Clamping Force | >430 kPa (adjustable) |
| System Seal Integrity | <10% pressure drop within 1 min at Pmax |
| Pressure Gauge Set Point | 2.5–3.0 kg/cm² |
| Dimensions (L×W×H) | 400 × 350 × 500 mm |
| Weight | 33 kg |
| Required Air Supply | 0.5–0.7 MPa (user-provided) |
| Operating Temperature | 15–50 °C |
| Relative Humidity | ≤80%, non-condensing |
| Power Supply | 220 V, 50 Hz |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YSD-03 |
| Price | Upon Request |
| Load Capacity | 0–3000 N |
| Accuracy | ±1% FS |
| Platen Diameter | φ120 mm |
| Resolution | 1/10000 |
| Compression Speed | 12.5 ± 2.5 mm/min |
| Dimensions (L×W×H) | 390 × 350 × 690 mm |
| Weight | 56 kg |
| Operating Temperature | 15–50 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | 220 V, 50 Hz |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZWHD-10A |
| Price | Upon Request |
| Measurement Range | 0–99999.9 s |
| Accuracy | ±0.1 s |
| Test Area | 10.0 ± 0.05 cm² |
| Applied Pressure | 100 kPa ± 2 kPa |
| Pre-compression Duration | 60 s (compliant with GB/T 456, ISO 8791-2, TAPPI T479) |
| Display | Chinese-character dot-matrix LCD |
| Interface | RS232 serial port |
| Dimensions (L×W×H) | 370 × 330 × 390 mm |
| Weight | 30 kg |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7101 |
| Pricing | Available Upon Request |
| Measurement Range | 0.002–70 g/(m²·d) (unmasked) |
| Temperature Control Range | 10–40 °C (50–104 °F) |
| Relative Humidity Control Range | 20–90 % RH |
| Sample Area | 50 cm² (adapters available for smaller specimens) |
| Sensor Technology | High-sensitivity Coulometric P₂O₅ sensor |
| Compliance | ASTM F3299–18 |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8101e |
| Test Gas | O₂ |
| RH Control Range | 0–90% ±2% |
| Temperature Control Range | 10–40°C ±0.1°C |
| Sensor Type | eMetric™ Coulometric Sensor |
| Sample Types | Flexible Films & Rigid Packaging |
| Maximum Configurable Stations | 32 |
| Operating System | Windows®-based Platform |
| Sealing Method | Q-Seal™ Chamberless Seal |
| Compliance | ASTM F2622, ASTM D3985, ISO 15105-2, ISO 1186 |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | Lyssy L80-6000 |
| WVTR Range | 0.03 – 10,000 g/m²/day (standard) |
| Test Temperature Range | 5 – 50°C |
| Relative Humidity Control Range | 5 – 60% RH |
| Ambient Humidity Tolerance | 10 – 90% RH (non-condensing) |
| Dimensions | 400 × 400 × 350 mm |
| Weight | 24 kg |
| Software | Permetrace™ |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | DIT-ASTM D1709 |
| Test Methods | ASTM D1709 (Method A & B), GB/T 9639, JIS K7124 |
| Mass Range | Method A: 50–2000 g |
| Method B | 300–2000 g |
| Resolution | 0.1 g (0.1 J) |
| Sample Clamping | Pneumatic, ≤1.1 MPa air supply required |
| Sample Size | >150 mm × 150 mm |
| Dimensions (A/B) | 450×450×1365 mm / 450×450×2160 mm |
| Power | AC 220 V, 50 Hz |
| Weight | 70 kg |
| Interface | Standard RS232/USB |
| Data Analysis | Built-in min/max/mean/SD calculation |
| Optional | Ball Impact Module, DSM Lab Data Management System, Safety Guard Kit |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GB 8809-1988 Pendulum Impact Tester |
| Impact Energy Options | 1 J, 2 J, 3 J, 5 J (selectable) |
| Resolution | 0.001 J |
| Impact Head Diameter | Ø25.4 mm, Ø19 mm, Ø12.7 mm |
| Clamp Aperture | Ø89 mm, Ø60 mm |
| Specimen Size | 100 mm × 100 mm or Ø100 mm |
| Pneumatic Pressure Range | 0.3–1.5 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 492 × 383 × 752 mm |
| Net Weight | 44 kg |
| Compliance | GB/T 8809–1988, ASTM D3420, NF T54-116 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GTR-7004 |
| Price Range | USD 14,000–21,500 |
| Test Range | 15–15,000 s/100 mL (standard) |
| Resolution | 0.1 s/100 mL |
| Sample Count | 1 |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Max Sample Thickness | ≤5 mm |
| Test Gas | Clean compressed air (user-supplied) |
| Air Supply Pressure | 0.3–1.0 MPa |
| Interface | Ø6 mm pneumatic fitting |
| Dimensions | 320 × 380 × 410 mm (L×D×H) |
| Power | AC 220 V, 50 Hz |
| Net Weight | 25 kg |
| Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTESTER GTR-1 |
| Price Range | USD 14,000 – 28,000 |
| Test Principle | Vacuum Pressure-Difference Method |
| Test Chamber | Single-cell |
| Temperature Control | Circulating medium thermostatic control (5 °C to 95 °C, optional) |
| Temperature Accuracy | ±0.1 °C |
| Vacuum Resolution | 0.1 Pa |
| Permeation Range | 0.01–170,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Thickness Limit | ≤3 mm |
| Effective Test Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas source, 0.3–1.0 MPa) |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Compliance Standards | GB/T 1038–2000, ISO 15105-1, ISO 2556, ASTM D1434, JIS K 7126-1, YBB 00082003 |
| Software Features | Audit trail, system logging, 5-level user permission management, DSM LIMS integration (optional) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Jinan SYSTESTER Heat Sealing Tester |
| Price Range | USD 4,200 – 7,000 |
| Touchscreen Interface | Industrial TFT LCD |
| UI Design | Zero-navigation-depth flat interface |
| Temperature Control | Dual independent sealing bars |
| Max Operating Temperature | 300 °C |
| Temp Range | RT + 6 °C to 300 °C |
| Temp Accuracy | ±0.2 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–1.1 MPa |
| Sealing Area | 265 mm × 12 mm (customizable) |
| Sealing Mode | Dual-bar independent control |
| Pneumatic Interface | Ø6 mm |
| Air Supply Requirement | 0.05–1.1 MPa (user-supplied) |
| Dimensions (L×W×H) | 410 × 396 × 416 mm |
| Weight | 33 kg |
| Power | AC 220 V, 50 Hz |
| Safety Features | Emergency stop button, anti-scald housing, fanless design |
| Noise Level | <35 dB(A) |
| Standard Compliance | QB/T 2358 (equivalent to ZBY 28004), ASTM F2029, YBB00212005-2015 |
| Data Output | Integrated thermal printer |
| Communication Interface | Standard RS232/USB |
| Optional Integration | DSM Laboratory Data Management System (sold separately) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | Membrane Separation Performance Evaluation System |
| Test Range | 0.01–2×10⁴ Barrer |
| Gas Flow Rate | 0–100 mL/min (200/300 mL/min optional) |
| Measurement Accuracy | ±0.01 Barrer |
| Vacuum Accuracy | ±0.1 Pa |
| Test Pressure Differential | 0–10 bar (system rated to 16 bar) |
| Temperature Control Range | 5–95 °C (±0.1 °C with optional chiller/heater) |
| Effective Test Area | Φ20 mm (3.14 cm²) |
| Sample Thickness Limit | ≤2 mm |
| Sample Capacity | 1 specimen per run |
| Detector Sensitivity | ≥5000 or 10000 mV·mL/mg (configurable) |
| Baseline Drift | ≤0.10 mV |
| Noise | ≤0.015 mV |
| Carrier Gas Pressure | 2 bar |
| Compatible Carrier Gases | N₂, H₂, He, Ar |
| Dimensions (Host) | 320 × 625 × 335 mm (W×D×H) |
| (GC Unit) | 590 × 480 × 500 mm (L×W×H) |
| Power Supply | AC 220 V, 50 Hz |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OX2/231 |
| Price Range | USD 28,000 – 42,500 |
| Measurement Principle | Coulometric Sensor (ISO 15105-2 Compliant) |
| Test Method | Isobaric Equal-Pressure Mode |
| Chambers | 3 Independent Testing Cells |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0%RH, 35–90%RH (±1%RH accuracy) |
| Film OTR Range | 0.01–6500 cm³/m²·d (standard), up to 63,000 cm³/m²·d (optional) |
| Container OTR Range | 0.0001–62 cm³/pkg·d |
| Film Resolution | 0.001 cm³/m²·d |
| Container Resolution | 0.00001 cm³/pkg·d |
| Test Area | 48 cm² |
| Sample Size (Film) | ≥150 mm × 94 mm or circular |
| Sample Size (Container) | ≤Φ120 mm × 400 mm (H) |
| Max. Thickness | 3 mm |
| Carrier Gas | 99.999% High-Purity N₂ |
| Flow Rate | 0–200 mL/min |
| Interface | 1/8″ Stainless Steel Tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 |
| Software | Embedded Win-based Control & Analysis Suite with Audit Trail, Multi-level User Access (5 tiers), Real-time Curve Logging (T, RH, Flow, OTR), Optional DSM Laboratory Data Management System Integration |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QBT 2411 |
| Price Range | USD 18,000 – 24,500 |
| Test Principle | Gravimetric Cup Method |
| Test Range | 0.001–220 µg/(m²·s) |
| Permeability Range | 1×10⁻³–40,000 ng/(m²·s·Pa) |
| Sample Capacity | 6 independent stations |
| Weight Resolution | 0.0001 g |
| WVTR Resolution | 0.00001 µg/(m²·s) |
| Temperature Range | 15–55 °C (±0.1 °C control accuracy) |
| Humidity Range | 10–95 %RH (±1 %RH control accuracy |
| Air Sweep Velocity | 0.5–2.5 m/s |
| Specimen Thickness Limit | ≤25 mm |
| Test Area | 33.17 cm² |
| Specimen Diameter | Φ81 mm |
| Chamber Volume | 36 L |
| Air Supply | Compressed air, 0.2–1.0 MPa, Φ8 quick-connect fitting |
| Power | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 650 × 550 × 475 mm |
| Net Weight | 67 kg |
| Compliance | GB/T 1037, QB/T 2411–1998 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | TSL-1002 |
| Load Capacity Options | 50 N, 100 N, 250 N, 500 N, 1000 N, 2000 N |
| Test Speed Range | 0.1–1000 mm/min (software-controlled, infinitely variable) |
| Stroke | 1000 mm |
| Displacement Resolution | 0.01 mm |
| Clamp Width (standard) | 30 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (L×W×H) | 380 × 450 × 1309 mm |
| Net Weight | 92 kg |
| Accuracy Class | Better than Grade 0.5 |
| Compliance Standards | GB/T 3923.1–2013, GB/T 17200, ISO 37, ASTM D882, ASTM D1938, ASTM F88, EN ISO 11600, JIS P8113 |
| Brand | T/A |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FP-2260 |
| Price Range | USD 14,000 – 70,000 |
| Standards Compliance | ASTM D1894, D4521, D3330, F88 |
| Load Cell Options | 0.5 kg, 1 kg, 2 kg, 10 kg |
| Resolution | 0.1 g |
| Accuracy | ±0.25% of full scale |
| Force Units | g, kg, oz, lb, N |
| Test Speed | Standard: 1–20 in/min |
| High-Speed | 10–110 in/min |
| Standard Sled Masses | 200 g, 500 g, 1000 g, 3 lb |
| Test Duration | 0.1–99 s |
| Travel Distance | 0.1–14.0 in |
| Display | 240 × 64 pixel LCD |
| Data Storage | 127 test records |
| Test Area | 225 mm × 350 mm |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 27 in × 12 in × 7 in |
| Weight | 20 kg |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | ProTear |
| Measurement Principle | Elmendorf Pendulum Tear Method |
| Compliance Standards | ASTM D1922, D1424, D295, D751 |
| Display | 4-line × 16-character LCD, multi-angle viewing |
| Accuracy | ±0.2% of pendulum capacity |
| Sample ID Input | 13-character alphanumeric |
| Data Storage | Up to 99 test results |
| Statistical Functions | Mean, Std. Deviation, Min/Max, Variance |
| Units | gf, lbf, mN, % of pendulum capacity |
| Fixture | Pneumatically actuated clamping |
| Pendulum Release | Pneumatic |
| Power Supply | 220–230 V ±10%, 50 Hz |
| Power Consumption | ≤10 W |
| Dimensions (L×W×D) | 578 × 483 × 398 mm |
| Operating Temp. | 10–50 °C |
| Storage Temp. | −25–70 °C |
| Sample Compatibility | Paper, board, film, foil, nonwovens, coated fabrics, packaging laminates |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-10 |
| Sealing Temperature Range | 20–400 °C (±0.15 °C accuracy) |
| Temperature Resolution | ±0.1 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 100 ms–99 s |
| Time Resolution | 10 ms |
| Time Accuracy | ±1 ms |
| Time Repeatability | ±2 ms |
| Dual Load Cells (Left/Right) | 362 kg (1000 lbf) total capacity, ±0.09 kg (±0.2 lbf) accuracy & repeatability |
| Peel Load Cell | 11.34 kg (25 lbf), 0.1% FS accuracy, ASTM E-4 calibrated |
| Seal Jaw Length Options | 50.8 mm (2 in) for hot tack or 127 mm (5 in) with auto-feed turntable |
| Jaw Width Range | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Configurations | Flat, Grooved, Custom, or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended 90 psi), integrated pressure switch |
| Dimensions (W×D×H) | 584.2 × 508 × 794.2 mm |
| Weight | 79.3 kg |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-2 |
| Sealing Temperature Range | Ambient to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 200 ms–99 s (with 10 ms resolution at low load |
| Time Accuracy | ±25 ms |
| Time Repeatability | ±50 ms |
| Jaw Length | Up to 304.8 mm (12 in) |
| Jaw Width | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Options | Flat, Grooved, Custom or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended: 90 psi) |
| Dimensions (W×D×H) | 584.2 × 400 × 620 mm |
| Weight | 72.5 kg |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Model | TY-CHY |
| Measurement Range | 0–5 mm (customizable fixtures available) |
| Measuring Pressure | 17.5 ± 1 kPa (for films), 50 ± 1 kPa (for paper) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Class of Accuracy | Grade 0.5 |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions | 450 × 340 × 390 mm |
| Weight | 30 kg |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 6672-2001, GB/T 451.3-2002, GB/T 6547-1998, ISO 4593:1993, ISO 534:2011, ISO 3034:2011, ASTM D374-1999, ASTM D1777-1996 (2007), JIS K6250-1997, JIS K6783-1994, JIS Z1702-1994, BS 3983-1989, BS 4817, TAPPI T411 |
| Interface | RS232 serial port |
| Optional Accessories | Auto-sampler unit, PC-based analysis software, calibration weights, communication cable |
| Brand | TME |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Solution |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Detection Principle | Differential Pressure Decay & Mass Flow Measurement |
| Channels | 1–4 Simultaneous or Sequential |
| Pressure Range | –13.5 to 300 psig (customizable) |
| Vacuum Range | –13.5 to 0.5 psig |
| Flow Range | 10–10,000 ccm (customizable) |
| Resolution | 0.0001 psig |
| Data Storage | 100 test configurations + 5,000 result records |
| Interface | RS-232 |
| Calibration | NIST-traceable |
| Compliance | Designed for ISO 9001, ASTM F2096, ASTM D3078, USP <1207>, and GMP-aligned validation protocols |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 83-20 |
| Measurement Principle | Pendulum-type Elmendorf method |
| Max Range | 64,000 mN |
| Range Steps | 4,000 / 8,000 / 16,000 / 32,000 / 64,000 mN |
| Accuracy | ±1% of reading or ±0.25% of selected range |
| Sample Cut | Automatic pre-notch |
| Clamping | Pneumatic-mechanical dual-action clamp |
| Display | Digital force readout |
| Data Interface | RS-232 serial output |
| Safety | Interlocked transparent guard |
| Reset Mechanism | Motorized pendulum repositioning |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 83-76 |
| Power Supply | 120/240 VAC, 50/60 Hz |
| Pneumatic Pressure Requirement | 600 kPa |
| Dimensions (W×D×H) | 305 × 305 × 508 mm |
| Weight | 10.4 kg |
| Display | 7-inch full-color touchscreen |
| Data Storage Capacity | up to 200 test records |
| Tear Force Units | gf, mN, lbf, % full scale |
| Clamping Pressure | adjustable in psi |
| Optional Pendulums | 200 g, 400 g, 800 g, 1600 g (83-11-08), 3200 g (83-11-06), 6400 g (83-11-07) |
| Interface Options | USB flash drive, USB ESC/POS printer, RS232, GraphMaster™ software port |
| Compliance | ASTM D1922, ASTM D1424, ISO 1974, TAPPI T414, GB/T 455 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WDDG |
| Pricing | Available Upon Request |
| Power Supply | 220 V AC, ~50 W |
| Carrier Gas | High-Purity Nitrogen, 5–10 L/h at ~0.5 bar inlet pressure |
| Measurement Range | 0–10 g/m²·day |
| Output | Direct digital readout across full scale (2.5-digit resolution) |
| Connected Meter | Triple-range analog meter (0–0.1 / 0–1.0 / 0–10 g/m²·day), 100 mV full-scale output |
| Accuracy | ±2% of reading or ±0.005 g/m²·day (whichever is greater) |
| Test Duration | 1–3 hours (sample-dependent) |
| Sample Diameter | 108 mm |
| Temperature Range | –20 °C to +60 °C |
| RH Gradient Generation | Compliant with DIN 53122 Part 2 |
| Dimensions (W×D×H) | 45 × 33 × 45 cm |
| Weight | 23 kg |
| Brand | WEISSTECH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WSPL-M |
| Price | ¥19,900 |
| Test Method | Semi-Automatic |
| Measurement Range | 200–5600 kPa |
| Unit Options | kPa, psi (lbf/in²), kgf/cm² |
| Accuracy | ±0.5% FS |
| Clamping Ring Diameter | Upper & Lower Rings: 31.5 mm |
| Hydraulic Oil Speed | 170 ± 15 mL/min |
| Display | LED Digital Display |
| Hydraulic Medium | Imported Silicone Oil |
| Power Supply | 220 V, 50 Hz |
| Safety Protection | Automatic pressure relief upon overpressure detection |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.305-YPL |
| Applicable Standards | JIS K6404-11, P8112, P8131, TAPPI T403, T807, T810, ISO 2758, ISO 2759 |
| Pressure Range | Low-pressure configuration (typically up to 1.6 MPa / 232 psi) |
| Test Principle | Hydraulic diaphragm burst method with clamped specimen |
| Display | Digital readout |
| Compliance | Designed for GLP-compliant lab environments with manual data recording capability |