| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | Aode200-20108 |
| Price | USD 5,300 (approx.) |
| Brand | Aode |
|---|---|
| Model | Aode200B |
| Drive Type | Electromagnetic 3D Vibration |
| Sample Compatibility | Dry powders, granules, and fine/coarse aggregates |
| Software Integration | Embedded sieve analysis software with automatic mass upload, real-time distribution calculation, and ASTM/USP-compliant reporting |
| Compliance | Meets ISO 2591-1, ASTM E11, USP <786>, and Chinese Pharmacopoeia IV sieve requirements |
| Data Output | Automatic particle size distribution (%) per sieve mesh, cumulative/differential curves, PDF/CSV export, unlimited report storage |
| Power Supply | 220 VAC, 50 Hz |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Aode309 (211224) |
| Instrument Category | Powder Flowability Tester |
| Measurable Parameters | Flow Time, Discharged Mass, Angle of Repose (θ), Bulk Density, Heap Mass, Loose Bulk Density |
| Maximum Sample Vessel Capacity | 520 mL |
| Minimum Sample Requirement | 10 g |
| Power Supply | 5 V DC |
| Dimensions | 280 × 280 × 600 mm |
| Weight | 8 kg |
| Funnel Outlet Diameters | 4, 6, 8, 10, 13, 15, 18, 20 mm |
| Construction Materials | 304 Stainless Steel & Aluminum Alloy |
| Compliance | GB/T 21060–2007, ISO 4324 |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | Aode309 |
| Instrument Type | Flowability Tester |
| Measurable Parameters | Angle of Repose (Static), Angle of Rest, Flow Time |
| Maximum Sample Vessel Capacity | 500 mL |
| Minimum Sample Volume | 5 mL |
| Power Supply | 5 V DC |
| Dimensions (W×D×H) | 280 × 280 × 600 mm |
| Weight | 8 kg |
| Funnel Volume | 520 mL |
| Adjustable Orifice Diameters | 4, 6, 8, 10, 13, 15, 18, 20 mm |
| Construction Materials | 304 Stainless Steel & Aluminum Alloy |
| Compliance | GB/T 21060–2007, ISO 4324 |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Aode310 |
| Instrument Category | Flowability Tester |
| Measurable Powder Parameters | Flowability Index, Flow Time |
| Maximum Sample Cup Capacity | 500 mL |
| Minimum Sample Requirement | 5 mL |
| Brand | Aode |
|---|---|
| Model | Aode75 Type 20114 |
| Origin | Liaoning, China |
| Manufacturer | Direct Producer |
| Category | Domestic Laboratory Instrument |
| Price | USD 8,100 (FOB) |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Yes |
| Model | Aode75 |
| Power Supply | 220 V, 50 Hz |
| Dimensions (W×D×H) | 30 × 54 × 26 cm |
| Door Opening Height | 80 cm |
| Weight | 18 kg |
| Vibration Frequency | 3600 cycles/min (60 Hz base air column resonance) |
| Adjustable Frequency Range | 2–300 Hz |
| Sieving Time Range | 1.00–99.99 min |
| Max. Sieving Capacity | 10 g |
| Min. Sieving Capacity | 0.1 g |
| Particle Size Range | 5 µm – 4.75 mm |
| Max. Stackable Sieves | 6 |
| Vertical Tapping | Integrated intermittent impact mechanism |
| Standard Compliance | GB/T 13220 (China), ASTM E323, ASTM D161 |
| Sieve Certification | NMI-traceable aperture verification with individual calibration certificate per sieve set |
| Noise Level | <65 dB(A) |
| Control System | Microprocessor-based digital timer and frequency controller |
| Optional Software | Automated mass-based fraction quantification, cumulative/differential particle size distribution calculation, real-time curve plotting (D10/D50/D90), CSV export, audit trail support |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Category | Domestic |
| Model | DV-200R |
| Price | USD 3,100 (FOB) |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Aode-502 |
| Instrument Type | Powder Flowability Tester |
| Measurable Parameter | Bulk Density |
| Maximum Sample Cup Capacity | 25 mL |
| Minimum Sample Requirement | 10 mL |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Aode-502-1 |
| Instrument Type | Flowability Tester |
| Measurable Parameters | Apparent Density, Bulk Density |
| Maximum Sample Cup Capacity | 500 mL |
| Minimum Sample Requirement | 10 mL |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | WLP-216G |
| Product Type | Intelligent Fisher Sub-Sieve Analyzer |
| Porosity Range | 0.25–0.95 |
| Repeatability | ±3% |
| Measurement Range | 0.2–100 µm |
| Display Interface | PC-based Software Visualization |
| Inlet Gas Pressure | 5 kPa |
| Power Supply | 220 V / 50–60 Hz, 60 W |
| Host Weight | 17 kg |
| Dimensions (W×D×H) | 57 × 59 × 25 cm |
| Operating Environment | 15–35 °C, ≤80% RH, vibration-free, non-corrosive atmosphere |
| Compliance | ASTM B330, ISO 9277 (gas adsorption correlation), USP <429>, GLP-ready audit trail and user management |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | ASA |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–1200 µm |
| Repeatability | <1% |
| Measurement Duration | Unlimited |
| Analog Bandwidth | 10–160 MHz (standard), upgradable to 10–200 MHz |
| Max Sampling Rate | 320 MHz (standard), upgradable to 400 MHz |
| Signal Processing Architecture | Quadrature-based Fourier Transform (FT) with Phase Pulse Detection (PPD) and Adaptive Sampling |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | PDI-TK |
| Type | Laboratory Laser Diffraction Particle Analyzer |
| Dispersion Method | Dry & Wet |
| Measurement Range | 1–1200 µm |
| Repeatability | <1% |
| Measurement Duration | Unlimited |
| Laser Source | Diode-Pumped Solid-State (DPSSL) Laser |
| Wavelength | 532 nm |
| Optical Probe Weight | 2.63 kg (TK1), 2.86 kg (TK2) |
| IP Rating | IP66 |
| Calibration | NIST-Traceable, Single-Calibration-for-Life |
| Signal Processor | ASA2 Advanced Signal Analyzer |
| Software Platform | AIMS (Advanced Imaging & Measurement Suite) |
| Optional Accessories | Anti-Fog Window Shroud, Integrated Thermostatic Heating Module for Sub-Zero/Freezing Environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HIAC 9703+ |
| Instrument Type | Optical Liquid Particle Counter |
| Sample Volume Range | 1 mL to 1000 mL |
| Particle Size Detection Range | 0.5 µm to 600 µm |
| Regulatory Compliance | FDA 21 CFR Part 11, ISO 21501-4 |
| Preconfigured Pharmacopoeial Methods | USP <788>, USP <789>, EP 2.9.19, JP 6.07, KP 5.2.10 |
| Software | PharmSpec v5.x with Audit Trail, Electronic Signatures, and Automated Backup/Restore |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LS 13 320 XR |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 10 nm – 3500 µm |
| Repeatability | < ±0.5% |
| Measurement Time | 10 seconds |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MET ONE 3400+ |
| Instrument Type | Optical Particle Counter |
| Flow Rates | 28.3 L/min, 50 L/min, 100 L/min |
| Standard Sizing Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (model-dependent) |
| Laser Source | Long-life laser diode (MTBF ≥ 10 years) |
| Power | AC input 80–264 VAC |
| Dimensions | 26.7 × 26 × 21 cm (10.5" × 10.25" × 8.25") |
| Weight | 5.6 kg (no battery), 6.9 kg (with 2 cells) |
| Enclosure | 316 stainless steel |
| Operating Environment | 0–40°C, 10–90% RH (non-condensing) |
| Compliance | FDA 21 CFR Part 11 ready, ISO 21501-4, ISO 14644-1, EU GMP Annex 1 compatible |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MET ONE 6000 |
| Instrument Type | Optical Airborne Particle Counter |
| Particle Size Channels | Standard 2-channel (0.3 µm & 0.5 µm), optional 4-channel configuration |
| Light Source | Long-life laser diode |
| Dimensions | 17.15 × 11.43 × 31.75 cm (W × L × H) |
| Weight | 0.68 kg |
| Housing Material | 304 stainless steel |
| Power Supply | 9–28 VDC |
| Max. Power Consumption | 3.3 W (serial/pulse), 4.3 W (Ethernet) |
| Operating Temperature | 10–32 °C |
| Operating Humidity | 5–95% RH, non-condensing |
| Storage Temperature | −40–70 °C |
| Storage Humidity | 5–98% RH, non-condensing |
| Flow Control | Precision orifice-based |
| Flow Rate Options | 0.1 CFM (2.83 L/min) or 1.0 CFM (28.3 L/min) |
| Counting Efficiency | ≥50% at 0.3 µm |
| Coincidence Loss | ≤5% at 2×10⁶ particles/ft³ (7.06×10⁷ particles/m³) for 6002/6003 variants |
| False Count Rate | ≤1 particle per 5 minutes |
| Communication Interfaces | Pulse output, 4–20 mA analog, RS-232, RS-485 (Modbus RTU or FXB), Ethernet TCP/IP |
| Diagnostic Indicators | Multi-color LED status indicator (normal operation, count alarm, sensor fault, flow fault, comms fault) |
| Optional Sensors | Integrated temperature and relative humidity (RH/T) probe |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MET ONE 6000P |
| Instrument Type | Optical Airborne Particle Counter |
| Flow Rate Options | 0.1 cfm or 1.0 cfm |
| Sizing Thresholds | 0.3 µm and 0.5 µm |
| Channel Configurations | Standard 2-channel or optional 4-channel |
| Light Source | Long-life laser diode |
| Housing Material | Stainless steel |
| Dimensions | 17.15 × 11.43 × 31.75 cm (W × D × H) |
| Weight | 4.62 kg (10.2 lb) |
| Power Supply | 24 VDC ±10% or 100–230 VAC, 50/60 Hz |
| Max. Power Consumption | 50 W (DC), 7.9 W (AC) |
| Operating Temperature | 10–32 °C |
| Operating Humidity | 5–95% RH, non-condensing |
| Storage Temperature | −40–70 °C |
| Storage Humidity | 5–98% RH, non-condensing |
| Counting Efficiency Loss | ≤5% at 2×10⁶ particles/ft³ (7.1×10⁷ particles/m³) and at 4×10⁵ particles/ft³ (1.4×10⁷ particles/m³) |
| False Count Rate | ≤1 particle per 5 minutes |
| Flow Control | Microprocessor-based with differential pressure sensor |
| Pump Type | Integrated vacuum pump |
| Compliance | ISO 21501-4:2018, ISO 14644-1:2015, FDA 21 CFR Part 11 (data integrity support), EU GMP Annex 1 (2022) alignment |
| Output Interfaces | 4–20 mA analog, Ethernet TCP/IP, Modbus RTU (RS-485), pulse output, optional wireless modules |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | MET ONE 7000 |
| Instrument Type | Optical Airborne Particle Counter |
| Flow Rate Options | 0.1 CFM or 1.0 CFM |
| Particle Size Sensitivity | 0.5 µm |
| Channel Configurations | 2-channel or 4-channel selectable |
| Light Source | Long-life laser diode |
| Housing Material | Electropolished stainless steel, VHP-resistant optics |
| Compliance | ISO 21501-4, ISO 14644-1/2, IEST-RP-CC021.1, FDA 21 CFR Part 11 (with optional audit trail software), GMP-environment validated design |
| Operating Temperature | 10–32 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Power Supply | 24 VDC ±10% or 100–230 VAC, 50/60 Hz |
| Max Power Consumption | 6.9 W (Ethernet DC), 12.5 W (Wireless AC) |
| Vacuum Requirement | ≥40.6 cm Hg |
| Flow Control | Precision orifice-based |
| Counting Loss | ≤5% at 2×10⁶ particles/ft³ (7005 variant) or 4×10⁵ particles/ft³ (7015 variant) |
| False Count Rate | ≤1 particle per 5 minutes |
| Communication Interfaces | Ethernet TCP/IP, RS-485 Modbus RTU/FXB, 4–20 mA analog output, wireless (optional) |
| Enclosure Rating | NEMA 4X |
| Weight | 3.73 kg (AC), 3.67 kg (DC) |
| Dimensions | 22.9 W × 12.5 D × 16.0 H cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Imported |
| Model | MET ONE HHPC 2+ |
| Instrument Category | Optical Particle Counter |
| Particle Size Range | 0.5–5.0 µm |
| Channels | 2 |
| Flow Rate | 2.83 L/min |
| Counting Efficiency | 50% at 0.5 µm, 100% ≥0.75 µm (per ISO 21501-4) |
| Zero Count Level | ≤1 count / 5 min (per JIS B9921) |
| Maximum Concentration Limit | 4,000,000 particles/ft³ (10% coincidence loss, per ISO 21501-4) |
| Data Storage Capacity | 10,000 records |
| Display | 3.5″ color TFT, 320 × 240 pixels |
| Operating Temperature | 10–40 °C, ≤95% RH (non-condensing) |
| Battery Life | >10 h typical, ≥5.5 h continuous |
| Dimensions | 10.7″ × 3.9″ × 2.1″ |
| Weight | 1.5 lbs (0.68 kg) |
| Enclosure Material | Polycarbonate-ABS blend |
| Compliance | ISO 14644-1, ISO 21501-4, JIS B9921, FS 209E |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Imported |
| Model | MET ONE HHPC 6+ |
| Instrument Category | Optical Particle Counter |
| Particle Size Range | 0.3–10 µm (6 channels per ISO 14644-1 & ISO 21501) |
| Flow Rate | 2.83 L/min |
| Weight | 1.5 lbs (0.68 kg) |
| Display | 3.5" color LCD (320 × 240) |
| Data Storage | 10,000 records |
| Counting Efficiency | 50% at 0.3 µm |
| Zero Count Level | ≤1 count/5 min (JIS B9921) |
| Maximum Concentration Limit | 4,000,000 particles/ft³ with <10% coincidence loss (ISO 21501) |
| Operating Environment | 10–40 °C, ≤95% RH (non-condensing) |
| Battery Life | ≥10 h typical, ≥5.5 h minimum continuous |
| Charging Time | 3.5 h |
| Housing Material | Polycarbonate-ABS blend |
| Dimensions | 10.7" × 3.9" × 2.1" (272 × 99 × 53 mm) |
| Connectivity | USB 2.0, Ethernet (HTTP-based web interface), USB flash drive support |
| User Interface Languages | English, Japanese |
| Alarm Configuration | User-defined particle count thresholds |
| Security | Optional administrator password protection |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MET ONE R4800/R4900 |
| Instrument Type | Optical Particle Counter |
| Minimum Detectable Size | 0.3 µm (R4803/R4903) or 0.5 µm (R4805/R4815/R4905/R4915) |
| Flow Rate | 0.1 CFM (2.83 L/min) or 1.0 CFM (28.3 L/min) |
| Detection Principle | Laser Diode-Based Light Scattering |
| Channel Configuration | Dual-channel (e.g., 0.3/0.5 µm or 0.5/5.0 µm) |
| Counting Efficiency Loss | <5% at 2×10⁶ particles/ft³ |
| Operating Temperature | 12–41°C |
| Relative Humidity | 20–95% RH (non-condensing) |
| Power Interface | Open-collector FET output (max. 150 mA sink, 30 VDC off-state) |
| Communication | RS-485 (R4800 series) or 4–20 mA analog (R4900 series) |
| Housing Material | Stainless steel |
| Weight | 0.3 kg |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Multisizer 4e |
| Instrument Type | Electrical Sensing Zone (ESZ) Particle Analyzer |
| Measurement Principle | Coulter Principle (Electrical Sensing Zone) |
| Size Range | 0.4 µm – 1600 µm (diameter) |
| Volume Range | 0.033 fL – 2.145 × 10⁹ fL |
| Resolution | Up to 400 user-selectable channels |
| Compliance | ASTM D6913, ISO 13319, USP <788>, FDA 21 CFR Part 11, GLP/GMP-ready |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | DC |
| Instrument Type | Optical Particle Counter |
| Channel Diameter Options | 5 mm / 8 mm / 12 mm / 14 mm / 19 mm / 38 mm |
| Ferrous Particle Detection Ranges | 30–200 µm (micro), 200–300 µm (medium), >300 µm (large) |
| Non-Ferrous Particle Detection Ranges | 150–400 µm (micro), >400 µm (large) |
| Flow Rate Range | 1–10 L/min (DC-5) to 68–680 L/min (DC-38) |
| Operating Temperature | −40 °C to +75 °C (standard) |
| Max Oil Temperature | ≤85 °C (standard) |
| Max System Pressure | <2 MPa (standard) |
| Humidity | <95% RH |
| Power Supply | 18–36 V DC |
| Communication Protocols | CAN 2.0, RS-485, RS-422 |
| Communication Isolation Voltage | 2500 V DC |
| Electrical Isolation Voltage | 1500 V DC |
| Bus Node Capacity | 32 nodes |
| Standby Current | <0.25 A |
| Inrush Current | <1 A |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Model | KLD-T |
| Sample Compatibility | Hydraulic oil, lubricating oil, transformer oil (insulating oil), turbine oil (steam turbine oil), gear oil, engine oil, aviation kerosene, organic solvents, polymer solutions |
| Detection Principle | Light obscuration (optical blockage) with custom-designed flow cell and precision optical assembly |
| Sampling Method | Dual-mode pressure control (positive/negative pressure chamber for degassing and high-viscosity fluid handling) |
| User Interface | Built-in bilingual toggle (Chinese/English) |
| Data Storage | Onboard memory for traceable measurement records |
| Connectivity | RS-232 serial interface and Bluetooth 4.0 for host PC communication |
| Calibration & Standards | User-configurable particle size channels |
| Regulatory Context | Designed to support GLP-compliant workflows |
| Brand | BenChen |
|---|---|
| Diameter | 200 mm |
| Material | Dual-layer 304 stainless steel frame and mesh |
| Mesh Range | 10–500 mesh |
| Compliance | GB/T 6003.1–2012, ISO 3310-1:2016, USP <786>, EP 2.9.33 |
| Origin | Hebei, China |
| Manufacturer Type | Direct OEM/ODM Producer |
| Customization | Available for diameter, mesh count, and stack configuration |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PWA100 |
| Measurement Range | 0–90° |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Angular Accuracy | 0.1° |
| Angular Resolution | 0.01° |
| Sampling Frequency | 50 Hz |
| Surface/Interfacial Tension Range | 1–1000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Cell Dimensions | 20 mm diameter × 95 mm height |
| Instrument Dimensions | 250 × 420 × 800 mm (L×W×H) |
| Weight | 25 kg |
| Interface | USB 3.0 or higher |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instruments Co., Ltd. |
| Model | BeNano 180 |
| Particle Size Range | 0.3 nm – 10 μm |
| Size Measurement Reproducibility | ≤1% |
| Temperature Control Range | −15 °C to 120 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Measurement Time | ≤60 s |
| Detection Angle | 173° (backscattering) + optional 11.2° |
| Laser Wavelength | 671 nm (solid-state laser) |
| Correlator | Multi-speed mode, 25 ns minimum sampling interval, 4000 channels, 10¹¹ dynamic linear range |
| Detector | APD |
| Sample Volume | ≥40 μL (customizable) |
| Max. Sample Concentration | ≤40% w/v |
| Analysis Algorithms | Cumulants, General Purpose, CONTIN, NNLS |
| Supported Measurements | Hydrodynamic Diameter (D<sub>H</sub>), Polydispersity Index (PDI), Diffusion Coefficient (D), Interparticle Interaction Parameter (k<sub>D</sub>), Intensity/Volume/Area/Number Distributions, Molecular Weight (342 Da – 2 × 10⁷ Da), Solution Viscosity & Refractive Index, Microrheological Parameters (G*, G′, G″, η*, J) |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BeNano 180 Zeta Max |
| Price | Upon Request |
| Particle Size Range | 0.3 nm – 15 μm |
| Temperature Control Range | −15°C to 120°C |
| Temperature Stability | ±0.1°C |
| Sample Volume | 3 μL – 1 mL |
| Zeta Potential Measurement Range | No Practical Limit |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instruments Co., Ltd. |
| Model | BeNano 180 Zeta |
| Particle Size Range | 0.3 nm – 10 μm |
| Temperature Control Range | −15°C to 120°C |
| Temperature Stability | ±0.1°C |
| Zeta Potential Range | No practical limit |
| Minimum Sample Volume | 40 μL (customizable) |
| Detection Angles | 173° + 11.2° |
| Max. Sample Concentration | ≤40% w/v |
| Zeta Measurement Principle | Phase Analysis Light Scattering (PALS) |
| Electrophoretic Mobility Range | > ±20 μm·cm/V·s |
| Conductivity Range | 0 – ≥270 mS/cm |
| Molecular Weight Range | 342 Da – 2 × 10⁷ Da |
| Laser Wavelength | 671 nm (solid-state), optional wavelengths available |
| Correlator | Multi-speed mode, 25 ns minimum sampling interval, 4000 channels, 10¹¹ dynamic linear range |
| Detector | APD |
| Intensity Control | 0.0001% – 100%, auto/manual |