Particle/Powder Analysis Instruments
Filter
Showing 301–330 of 969 results
| Brand | GuanCe |
|---|---|
| Model | GCFT-1000C |
| Origin | Beijing, China |
| Instrument Type | Powder Flowability Tester |
| Compliance Standards | GB/T 31057.2–2018, GB/T 31057.3–2018, ASTM D6393–2014, USP <616>, EP 20934 |
| Rated Power | 500 W |
| Supply Voltage/Frequency | 220 V / 50 Hz |
| Tap Density Vibration Frequency | 300 taps/min |
| Sample Chamber Capacity | Standardized for 100–250 mL bulk samples (per ISO 4762 and ASTM D6393 protocols) |
| Minimum Sample Requirement | 50 g (for reproducible Carr Index and compressibility ratio determination) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCFT-1000D |
| Instrument Type | Powder Flowability Tester |
| Measurable Powder Parameters | Rated Power 500 W |
| Maximum Sample Vessel Capacity | Not Specified |
| Minimum Sample Quantity | Not Specified |
| Tap Density Vibration Frequency | 300 taps/min |
| Operating Voltage/Frequency | 220 V / 50 Hz |
| Compliance Standards | GB/T 31057.2–2018, GB/T 31057.3–2018, ASTM D6393–2014, GB/T 1479.1–2011, GB/T 5162–2021, USP <616>, Ph. Eur. 20934 (EP 7.0) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YHL-660936 |
| Instrument Category | Powder Flowability Tester |
| Measurable Material | Powder |
| Maximum Sample Cup Capacity | 40 mL |
| Minimum Sample Mass | 10 g |
| Funnel Material | Stainless Steel |
| Funnel Top Outer Diameter | 138.5 mm |
| Funnel Top Inner Diameter | 123 mm |
| Orifice Diameter | 3.95–4.0 mm |
| Total Funnel Height | 190.5 mm |
| Upper Cone Angle | 60° |
| Lower Discharge Cone Angle | 15° |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZKFT-16003 |
| Application Focus | Metal Powders |
| Instrument Type | Dynamic Imaging System |
| Field of View | 5.70 mm (H) × 4.28 mm (V) |
| Lens Count | 1 |
| Sample Dispersion Method | Gravity-fed static/dynamic dispersion compatible with standard sample trays or vibratory feeders |
| Exposure Time Range | 0.21 ms – 2000 ms (ROI-adjustable) |
| Signal-to-Noise Ratio | 66.5 dB |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | ZKFT-1600A |
| Application Focus | Metal Powders |
| Instrument Type | Dynamic Imaging System |
| Field of View | 5.70 mm (H) × 4.28 mm (V) |
| Lens Count | 1 |
| Sample Dispersion Method | Gravity-fed static dispersion on glass slide (compatible with dry or liquid suspension protocols) |
| Exposure Time Range | 0.21 ms – 2000 ms (ROI-selectable) |
| Signal-to-Noise Ratio | 66.5 dB |
| Optical Configuration | Integrated high-resolution microscope + progressive-scan CCD camera + motorized stage (optional) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | ZKFT-1600b |
| Application Focus | Metal Powders |
| Instrument Type | Dynamic Imaging System |
| Field of View | 5.70 mm (H) × 4.28 mm (V) |
| Lens Count | 1 |
| Sample Dispersion Method | Static Field-of-View Imaging with Controlled Illumination |
| Exposure Time Range | 0.21 ms – 2000 ms (ROI-Adjustable) |
| Signal-to-Noise Ratio | 66.5 dB |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZKFT-1600C |
| Application | Metal Powders |
| Instrument Type | Dynamic Imaging System |
| Field of View | 5.70 mm (H) × 4.28 mm (V) |
| Lens Count | 1 |
| Sample Dispersion Method | Gravity-fed free-fall imaging chamber (field-of-view defined) |
| Exposure Time Range | 0.21 ms – 2000 ms (ROI-adjustable) |
| Signal-to-Noise Ratio | 66.5 dB |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | ZKFT1600 |
| Application Scope | Metal Powders |
| Instrument Type | Static Imaging System |
| Dynamic Range | 66.5 dB |
| Number of Lenses | 6 |
| Image Resolution Accuracy | 100 µm |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZKFT1600 |
| Application | Metal Powders |
| Instrument Type | Static Imaging Analyzer |
| Measurement Range | 66.5 dB (dynamic range for grayscale intensity resolution) |
| Number of Lenses | 6 |
| Image Resolution Precision | 100 µm (minimum resolvable feature size under standard optical configuration) |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | TZC-4 Particle Size Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 1–260 µm |
| Repeatability | <1% |
| Measurement Time | 10 minutes |
| Maximum Capacity | 100 g |
| Readability | 1 mg |
| Particle Analysis Outputs | Sedimentation curve, D50 (median diameter), mean particle size, specific surface area, distribution histogram, error estimation |
| Brand | Herolab |
|---|---|
| Origin | Germany |
| Model | PM-200 |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Particle Size Range | 1–200 µm or 2–400 µm |
| Particle Concentration Range | 0–70,000 particles/mL |
| Minimum Sample Volume | 100 µL |
| Measurement Accuracy | >95% |
| Data Interface | USB |
| Regulatory Compliance | USP <787>, <788>, <789>, <1787>, <1788> |
| Brand | HJ |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ZJSJ-010 |
| Instrument Type | Optical Particle Counter Accessory |
| Dilution Ratio | 60–700× @ 28.3 L/min |
| Flow Rate | 28.3 L/min (standard) / 2.83 L/min (low-flow mode) |
| Dilution Control Method | Precision Mass Flow Regulation |
| Compliance | Designed for ISO 14644-1/3, ISO 21501-4, and USP <788> compliant particle counting workflows |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | HMD-1 |
| Measurement Principle | Oscillating U-tube (Digital Density Determination) |
| Sample Volume | 2 mL |
| Display | Color LCD with backlighted viewing window |
| Power | Rechargeable battery (≥6 h continuous operation) |
| Accuracy | ±0.001 g/cm³ |
| Temperature Control | Peltier-assisted (±0.02 °C stability) |
| Compliance | ISO 12084, ASTM D4052, USP <841> |
| Brand | Huameike (LABULK) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HMK-200 (01081623) |
| Principle | Air Jet Sieving |
| Measurement Range | 3–5000 µm |
| Maximum Load | 2000 g |
| Sieve Stages | Single-stage |
| Brand | LABULK |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Intelligent |
| Display | Digital Readout Panel, Touchscreen, PC Interface |
| Measurement Principle | Fisher Air Permeability (HMK-22), Air Jet Sieving (HMK-200), Static Light Scattering / Mie Theory (AS-2011) |
| Size Range | 0.2–50 µm (HMK-22), 3–5000 µm (HMK-200), 0.1–500 µm (AS-2011) |
| Repeatability | ≤3% (HMK-22), ≤3% (HMK-200), <1% (AS-2011) |
| Porosity Range | 0.25–0.95 (HMK-22) |
| Air Pressure | 0–10 kPa (HMK-200), 5 kPa (HMK-22) |
| Power Supply | 220 V / 50 Hz (all models), 110 V / 60 Hz (HMK-22 optional) |
| Weight | 18 kg (HMK-22), 14.8 kg (HMK-200), N/A (AS-2011) |
| Dimensions | 41.8 × 24.6 × 73.7 cm (HMK-22), 58 × 35 × 35 cm (HMK-200), N/A (AS-2011) |
| Compliance | ISO 13320-1 (AS-2011), ASTM B330 (HMK-22), ISO 4497 (HMK-200) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-300 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–600 µm |
| Repeatability | <1% |
| Measurement Time | 20 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LA-350 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 100 nm – 1000 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-960 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01–5000 µm |
| Repeatability | < 0.1% |
| Measurement Time | < 10 s |
| Compliance | ISO 13320 |
| Accuracy | ±0.6% |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-960 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01–5000 µm |
| Repeatability | <0.1% |
| Measurement Time | <10 s |
| Compliance | ISO 13320 |
| Accuracy | ±0.6% |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-960 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5 mm |
| Repeatability | ≤0.06% |
| Measurement Time | <1 min |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LA-960 V2 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5000 µm |
| Repeatability | ±0.1% |
| Measurement Time | 10 seconds |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Partica CENTRIFUGE CN-300 |
| Measurement Principle | Centrifugal Sedimentation |
| Measured Range | 10 nm – 40 µm |
| Maximum Centrifugal Force | 30,000 × g |
| Temperature Control | Integrated Peltier Cooling for Sample Cell and Rotor |
| Measurement Modes | Density Gradient Mode & Homogeneous Mode |
| Sample Volume | As low as 2 µL (undiluted) or 10 µL (diluted) |
| Compliance | IEC 61010-1:2010 / IEC 61010-2-020:2016 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | SZ-100 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.3 nm – 8 µm |
| Repeatability | <2% |
| Measurement Time | 120 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | SZ-100 |
| Dispersion Method | Dry & Wet Dispersion |
| Particle Size Range | 0.3 nm – 8,000 nm |
| Molecular Weight Range | 1,000 – 2 × 10⁷ Da (Debye plot method) |
| Repeatability | <2% |
| Measurement Time | ~2 minutes (from start to size result display) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SZ-100 V2 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Characterization System |
| Size Range | 0.3 nm – 10 µm |
| Reproducibility | ±2% |
| Measurement Time | < 2 min |
| Zeta Potential Range | −500 mV to +500 mV |
| Molecular Weight Range | 1,000 – 2×10⁷ Da |
| Detection Angles | 90° and 173° (automatically or manually selectable) |
| Sample Volume | 12 µL – 1,000 µL |
| Measurement Principle for Size | Dynamic Light Scattering (DLS), also known as Photon Correlation Spectroscopy (PCS) |
| Zeta Potential Principle | Laser Doppler Electrophoresis |
| Molecular Weight Determination | Debye Plot Analysis |
| Second Virial Coefficient (A₂) | Yes |
| Integrated Auto-Titrator | Yes (for pH-controlled zeta potential studies) |
| Compliance | NIST-traceable calibration with 100 nm standard particles |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ViewSizer 3000 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory NTA System |
| Measurement Range | 10 nm – 15 µm |
| Concentration Range | 5 × 10⁶ – 2 × 10⁸ particles/mL |
| Sample Volume | 350 µL – 1.25 mL |
| Temperature Control Range | 10 °C – 50 °C (±0.1 °C) |
| Dimensions | 55 cm W × 66 cm D × 35 cm H |
| Weight | 27 kg |
| Operating Environment | 15 °C – 30 °C, < 85% RH |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ViewSizer 3000 |
| Particle Size Range | 10 nm – 15 µm |
| Size Measurement Reproducibility | ±1% |
| Temperature Control Range | 10°C – 50°C |
| Temperature Stability | ±0.1°C |
| Light Sources | Blue, Green, Red (visible spectrum) |
| Measurement Principle | Nanoparticle Tracking Analysis (NTA) via dynamic light scattering and single-particle trajectory tracking |
| Sample Volume | 350 µL – 1.25 mL |
| Particle Concentration Range | 5×10⁶ – 2×10⁸ particles/mL |
| Measurement Duration | ~2 minutes per acquisition |
| Fluorescence Capability | Multi-wavelength excitation & detection enabled |
| Zeta Potential Measurement | Not supported |
| Molecular Weight Determination | Not supported |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ViewSizer 3000 |
| Pricing | Upon Request |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 10 nm – 15 µm |
| Repeatability | Not Specified |
| Measurement Time | 6 min |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 |
| Minimum Detectable Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Inspection Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Output | ≥6000 lm |
| Illumination Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 |
| Minimum Detectable Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Inspection Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Output | ≥6000 lm |
| Illumination Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Sample Tray Size | 200 × 200 mm (net) |